NEC 2OI7
Practice Exam
Based on the:
2017 National Electric Code
American Electrician's Handbook - 16tn Edition
9980 S. 300 W.
Suite 200
Sandy, UT 84070
866.720.77 68
www.provexam.com
Examination KeY: 987841 533 Booklet Number: 6298D000002
the NEC?
1. What is the MINIMUM calculated service demand for a sign circuit allowed by
A. 2400 watts
B. 1800 watts
C. 1500 waffs
D. 1200 watts
smallest size of
4. A radio or television receiving station is required to be grounded. What is the
aluminum conductor that is permitted?
A. #14 AWG
B. #12 AWG
C. #O AWG
D. #8 AWG
1
Examination Key: 987841 533 Booklet Number: 6298D000002
6. What is the MINIMUM drain hole size for electric signs located in a wet location?
A. Il4 inch
B. 3116 inch
C. 3/8 inch
D. ll2 inch
7. What is the MINIMUM backfill permitted for a direct burial cable that is protected by a20 amp
ground fault circuit intemrPter?
A. 12 inches
B. 18 inches
C. 24 inches
D. 30 inches
g. What is the MINIMUM size allowed for the bonding conductor used to connect the bonding grid on a
swimming pool?
B. A solid #8 AWG
C. A solid #6 AWG
D. A solid #4 AWG
2
Booklet Number: 6298D000002
Examination KeY: 987841 533
A. 3600 watts
B. 3450 watts
C. 2400 watts
D. 75 watts
l0.WhatistheMINIMUMsizeallowedforbondingconductorsusedinelectricsigns?
A. 14 AWG
B. 12 AWG
C. 10 AWG
D. 8 AWG
a
J
Examination Key: 987841533 Booklet Number: 6298D000002
13. A 240 volt,2 horsepower, single phase AC motor requires a branch circuit capable of carrying a
MINIMUM of:
A. 30 amps
B. 25 amps
C. 20 amps.
1
D. 15 amps
I
14. What would be the MINIMUM general lighting load for a 12' x 60' mobile home?
A. 2.16 KW
B. 2.1KW
c. 2160 KW
D. 2700 KW
A. 2 types. I
1
B. 3 types.
C. 5 types.
D. 6 types.
4
Examination Key: 987841 533 Booklet Number: 6298D000002
17. What is the MINIMUM size copper conductor that is permitted to be used as a grounding electrode
conductor for a service using 3/0 copper conductors?
A. #8 AWG
B. #6 AWG
C. #4 AWG
D. #2 AWG
19. What is the MAXIMUM operating temperature approved for a type SF-1 fixture wire?
A. 200 degrees F
B. 295 degrees F
C 392 degrees F
D 412 degrees F
20. A#10 conductor is required to have a MINIMUM of how many cubic inches of free air space when
installed in an outlet box?
A. 2.00
B. 2.25
c. 2.s0
D. 3.00
5
Examination Key: 987841 533 Booklet Number. 6298D000002
22. Which fuse rating is NOT considered to be a standard fuse size by the NEC?
A. 20 amps
B. 30 amps
C. 35 amps
D. 115 amps
23.Groundedconductorsthatare#-orsmallerarerequiredbytheNECtobeidentifiedbya
continuous white or gray outer finish or by three continuous white stripes on other than green
insulation along its entire length.
A. 2 AWG
B. 4AWG
C. 6 AWG
D. lOAWG
6
Booklet Number: 6298D000002
Examination KeY: 987841 533
supplied by #14
26. A230 volt, power single phase AC motor is connected to a branch circuit
1 % horse
permitted to protect this
THw conductors. what is the MAiIMUM inverse time delay breaker
circuit?
A. A 20 amP breaker
B. A 25 amP breaker
C. A 30 amP breaker
D. A 40 amP breaker
of type NM cable?
28. Which column of Table 310.15 shall be used for ampacity
A. 50 degrees Celsius
B. 60 degrees Celsius
C. 75 degrees Celsius
D. 90 degrees Celsius
7
Examination Key: 987841 533 Booklet Number: 6298D000002
30. The cord cap on a room air conditioner is permitted to serve as the required disconnect means if the
manual controls on the room air conditioner are located within:
A. 2.5 feet of the floor.
B. 3 feet of the floor.
C. 5 feet of the floor.
D. 6 feet of the floor.
31. What is the MINIMUM cubic inch capacity of a 1 ll4" deep 4" square metal box?
A. 2l cubic inches
B. 18 cubic inches
C. 15.5 cubic inches
D. 12.5 cubic inches
32. What is the MINIMUM number of branch circuits the NEC would require in a 2000 square foot
house using 15 amp circuits?
A.2
B.3
c.4
D.5
33. Light fixtures in a commercial garage with lanes where vehicle passage is common shall be either
enclosed or NOT less than:
A. 8 feet above the floor level.
B. 10 feet above the floor level.
C. 12 feet above the floor level.
D. 14 feet above the floor level.
34. Under what conditions are service entrance conductors considered outside a building?
A. If they are installed under a MINIMUM of 1 .5 inches of concrete beneath the building
B. If they are fused at less than 150 amps
C. If they are fused at less than 200 amps
D. If they are inside the building but encased in a MINIMUM 2.0 inches of brick
8
Examination Key: 987841 533 Booklet Number: 6298D000002
35. Flexible cord used to energize airwaft shall be of the type identified for:
A. dry locations.
B. hard usage.
C. extra hard usage.
D. explosion proof usage.
37. 410 conductorsare entering the top and bottom of a panelboard. The conductors are of compact
stranded AA-8000 aluminum alloy. Three conductors are intended to be connected to each terminal.
what is the MINIMUM wire bending space required at each terminal?
A. 4u
B. 7 ll2.
c. 10"
D. t2 U2"
38. How many square inches of 3l4" diameter electrical metallic tubing conduit that is 18" long can be
used for conductor fill?
A. 0.141
8.0.181
C. 0.320
D. 0.454
9
Examination Key: 987841 533 Booklet Number: 6298D000002
39. What is the lock rotor current for a I ll2 HP single phase 208 volt motor?
A. 11amps
B. 13.75 amps
C. 66 amps
D. 82.5 amps
41. What is the MAXIMUM overcurent protection for an electric heating appliance with resistance type
heating elements?
A. 30 amps
B. 48 amps
C. 50 amps
D. 60 amps
10
Examination Key: 987841 533 Booklet Number: 6298D000002
:i'
t SS'WsN $:1$t-$Wt
*sE$'s $uffi$s
tI
11
Examination Key: 98784'l 533 Booklet Number: 6298D000002
Ilrawing B
:
R1:20 chms, Rz 10 ohms, & :20 ohmsl
Voltage slrpplied * 60 Yolts DC
45. What is the total power consumed across R1, R2, and R3?
A. 1000 watts
B. 120 rvatts
C. 72 watts
D. 24 watts
t2
Generic Practice Exam
Answer Key
7 D 27. A
2 c 28. B
3 c 29.8
4 D 30. D
5 c 31. B
6 A 32. C
7 A 33. C
8 B 34. D
9 D 3s. c
10 A 36. D
71 B 37.8
12 A 38. C
13 D 39. C
14 A 40. c
15 c 4L.D
76 B 42. A
17 c 43. B
18 c 44.C
19 c 45. C
20 c
21, B
22 D
23 c
24 D
25 D
26 D