ELASTOMERIC WALL COATING

WATERPROOFING ACRYLIC

PRODUCT SPECIFICATIONS
PRODUCT Premium quality modified acrylic latex paint especially formulated as
DESCRIPTION waterproofing coat to give excellent abrasion resistance and resistance to
blistering under wet condition. The highly touch and flexible film ensures
excellent adhesion to concrete and various substrates.

PRODUCT  Excellent weather durability


FEATURES  Good adhesion - “Cross Hatch Adhesion Test” -------------------- 98% retention
A test to check whether the adhesion of a coating to a substrate or to another
coating is at a generally adequate level using a cutter or knife and an adhesive tape.
 Highly flexible film to give good elastic properties
 Eliminates water seepage, cement plastering defects like hairline cracking,
cement chipping
 Good resistance to water and atmospheric moisture
 Non-flammable- easy to use
 Non-hazardous – easy to store
 Low VOC ( Volatile Organic Compound ) - Any organic compound which
participates in atmospheric photochemical reactions in the room, produces chemicals
that can have a rash of short- and long-term effects, including eye irritation;
respiratory problems; headaches; loss of coordination; nausea; and damage to the
liver, kidneys and central nervous system.
Theoretical computed VOC is 85g/L which is lower the standard specification of
100 g/L.

TYPICAL USES Recommended for use on interior and exterior concrete, masonry, plaster, bricks,
hollow blocks, asbestos, acoustic boards, gypsum and fiber cement boards.

PHYSICAL Volume Solids (theoretical) 40 ± 3%


DATA Theoretical Coverage 20 -25 m2 /4L /coat, depending on surface
condition
Color White
Can be made available in custom colors, if
desired.
Finish Low Sheen

1 KE TI COATINGS
Version No.1 Dated July 2010 120 Sauyo Road, Novaliches, Quezon City
Telefax # 9381015
ELASTOMERIC WALL COATING
WATERPROOFING ACRYLIC

APPLICATION Method of Application Brush/ Spray / Roller


DATA Applied Over Properly prepared concrete surfaces
Wet Film Thickness /Coat 75 microns or 3 mils
Number of Coats 1 – 2 coats
Drying Time @ 28 °C
Set to Touch 20- 30 minutes
Dry Hard 45 – 60 minutes
Cooler temperatures, higher film thickness and /or
higher humidity will require longer drying time.
Conv. Spray: 40 psi
Brush : 1800 –2400 psi
Equipment Roller : Polyester or Nylon
Pad : Standard

Clean Up Soap and water / Water

ADDITIONAL % Reduction Unnecessary, but if required to obtain desired properties, a


INFORMATION small amount of clean water up to 5% may be added.
Mix thoroughly before using.

Storage Keep container tightly closed. Protect from extreme heat.


Stored closed container under dry cool condition away from
sources of ignition.
Packaging 1L, 4L, 16L

The service life span and the service performance of the product are directly
SURFACE related to the degree of the surface preparation.
PREPARATION
A. FOR NEW SURFACES

 Allow new masonry to dry for 28 days under standard atmospheric


conditions.
 Free surface from dust, dirt, oil, grease, all loose grit & motor and other
contaminants.
 Apply primer or undercoat sealer.
 Repair minor surface imperfections with putty.
2 KE TI COATINGS
Version No.1 Dated July 2010 120 Sauyo Road, Novaliches, Quezon City
Telefax # 9381015
ELASTOMERIC WALL COATING
WATERPROOFING ACRYLIC

 Apply primer. (Optional)

B. OLD PREVIOUSLY PAINTED SURFACES

 Scrape off loose, scaling and peeling old paints. Sand the whole surface
including those where old paint still adheres very well.
 For areas with extreme chalking problems, steel brush, blow air from a
compressor, or wipe with rag with water. Let dry, and then apply one coat
of Concrete Sealer before applying subsequent coat.
 For areas, affect with molds and mildew, wipe the whole surface with
clean rag wet with Clorox (Bleaching Solution). Scrub using a stiff nylon
brush then rises with water. Apply Fungicidal – washing compound. To
ensure proper treatment, leave overnight. Let dry.
 For area with mapping problems, properly prepare the surface, and then
apply one full coat of Concrete Sealer. Dry at least (4) hours.

APPLICATION

APPLICATION Stir paint thoroughly prior and during usage. Apply at package
METHOD consistency or at 5% maximum reduction. Apply an even coat to properly
prepared substrate. Allow the paint to dry (2 – 4) hours prior to recoating.

PRODUCT
RESTRICTIONS
Do not apply directly over wood and metal.
Do not use abrasive cleaners.

Do not allow the paint to dry on the equipment. Use water as the cleaning
EQUIPMENT
CLEAN UP
solvent. Spray equipment should be given a final rinse with mineral spirit
to prevent rusting.

3 KE TI COATINGS
Version No.1 Dated July 2010 120 Sauyo Road, Novaliches, Quezon City
Telefax # 9381015
ELASTOMERIC WALL COATING
WATERPROOFING ACRYLIC

All specifications and suggestions concerning the use of this product are based upon tests and data believed to be reliable. Since actual use
by our clients is beyond our control, no guarantee, expressed or implied is made by Ke Ti Coatings as to the effects of such use or the results
to be obtained.

4 KE TI COATINGS
Version No.1 Dated July 2010 120 Sauyo Road, Novaliches, Quezon City
Telefax # 9381015