Half-Open Pipe Nozzle

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 2

Instructions:

1. This excel file is applicable for Half-Open Pipe Nozzle.


2. Input your data (Yellow Cells).
3. Change IDs (Blue Cells) and compare momentum criterion and velocity (Green Cells) with limitation
(Red Table).
4. Values for GCAP reference are based on 7th edition and general but in 9th edition is updated and are
different for devices.

LIMITATION
Maximum Velocity Head (Momentum criterion)
Reference GPSA Shell
Feed Inlet, kg/m.s2 1500-3750 2100
Vapor Outlet, kg/m.s2 4500-5400 4500
Maximum Velocity
Liquid Outlet, m/s 0.9-1.5 1

DATA
Pressure, psia 23
Temperature, R 571
Z 0.98
Gas Density, kg/m3 1.7
Liquid Density, kg/m3 930.2
Gas Flow Rate, MMSCFD 2
Liquid Flow Rate, bbl/day 6000
Gas Flow Rate, m3/h 1623
Liquid Flow Rate, m3/h 40
Mixture Density, kg/m3 24
Inlet Nozzle ID, mm 300 11.81
Vapor Outlet Nozzle ID, mm 120 4.72
Liquid Outlet Nozzle ID, mm 130 5.12
RESULTS
Feed Inlet, kg/m.s 2
1020
Vapor Outlet, kg/m.s2 2702
Liquid Outlet, m/s 0.8
city (Green Cells) with limitation

t in 9th edition is updated and are

riterion)
GCAP IPS 850
3600 1500
5625 3750

1 1

inch
inch
inch