Professional Documents
Culture Documents
Airmaster Q Series ECO Ethernet Option Card Software Update Procedure
Airmaster Q Series ECO Ethernet Option Card Software Update Procedure
™
Airmaster , Q Series,
ECO card option, software update
Table of Contents
1. Software update through Micro SD card ..........................................................
................................ 2
1.1 Remove power ................................................................................................
................................ .................................. 2
1.2 Unlock the Micro SD card ................................................................
................................................. 2
1.3 Remove the Micro SD
D card by hand ................................................................
................................. 3
1.4 Put files onto the Micro SD card ................................................................
...................................... 3
1.4.1 Standard software update packet ................................................................
............................................................. 3
1.4.2 IP config ................................................................................................................................
................................ ...................................... 4
1.5 Reinsert the Micro SD card in the slot by hand................................
hand................................................ 4
1.6 Lock the Micro SD card.....................................................................................
................................ ..................... 5
1.7 Reapply power ................................................................................................
................................ .................................. 5
1.8 Check hardware OK indicators ................................................................
......................................... 5
1.9 Check web page operation ................................................................
............................................... 5
Revision history
W W W. CO N T RO L C O MP R ES SO RS. C O M
TE C HN I C AL D A T A
The following update process assumes the ECO card option is installed in a host Airmaster™Q1.
There is no requirement to remove the host Airmaster Q1 from its host device (e.g. an air
compressor), however it is important to assure that power has been removed
removed from the host
Airmaster™ Q1 during the update process and you will require access to the side wall of the
Airmaster™ Q1 during the update process.
W W W. CO N T RO L C O MP R ES SO RS. C O M
TE C HN I C AL D A T A
Put the Micro SD card into a proprietary Micro SD card reader (not supplied!). Once
inserted, use a proprietary PC (not supplied) to access the Micro SD cards file system.
Place the ECO card option, ‘software update packet’’ onto the Micro SD card’s file
system as shown below.
The ‘software
software update packet’
packet (QECMWEBS_EXX.zip) contains a number of files to put in
the root directory as indicated above. Just replace the existing
existing files in the root directory
of the SD card with the ones you find in the update packet on the root directory. These
are all the files required to operate the web pages. To update the actual ECO card
embedded software, a QECMWEBS.BIN file must be placed in the UPDATE sub directory.
W W W. CO N T RO L C O MP R ES SO RS. C O M
TE C HN I C AL D A T A
This file is also present in the update packet in the UPDATE directory. Upon power on
the ECO card will look for this file, use it, and delete it afterwards from the SD card.
1.4.2 IP config
The update packet comes with a setup forr a fixed dummy IP address. This can be
changed by editing the DEFNET.JS file with any standard text editor.
editor The content of this
file is shown below.
//.............................................NET
var SYS_HostName = "Q1_ECO_CARD";
var SYS_SMTPServerIp = "192.168.0.2";
var SYS_UseFixedIPAddress = 1;
var SYS_IPAddress = "192.168.0.97";
var SYS_SubnetMask = "255.255.255.0";
var SYS_DefaultGateway = "192.168.0.254";
var SYS_PrimaryDNSServer = "194.25.2.129";
var SYS_SecondaryDNSServer = "194.25.2.130";
To setup the ECO card for a fixed IP addres, set the variable SYS_UseFixedIPAddress = 1
and fill in the SYS_IPAddress, SYS_SubnetMask, SYS_DefaultGateway,
SYS_PrimaryDNSServer and SYS_SecondaryDNSServer values. You can access the
web pages by using the IP address
ad in your browser.
To setup the ECO card for a DHCP provided IP addres, set the variable
SYS_UseFixedIPAddress = 0 and fill in a desired URL name in the variable called
SYS_HostName = "Q1_ECO_CARD".
"Q1_ECO_CARD" You can access the web pages by using the URL in
your browser.
W W W. CO N T RO L C O MP R ES SO RS. C O M
TE C HN I C AL D A T A
W W W. CO N T RO L C O MP R ES SO RS. C O M