Remote Terminal Units - Data sheet

Communication unit 520CMD01


RTU520 product line

E1
CP1 CP2, CP3
10/100 MB LAN
RS232C RS485

Ethernet
UART UART
Controller

Processor bus

Serial line MPU RAM/Flash


interface ARM9 Memory

WRB I/O bus USB

Figure 1: Block diagram 520CMD01

Characteristics
On the applied ARM9 controller AT91SAM9260 a real-
time operating system is implemented. The 520CMD01
Application
is responsible for the interface management, the event
The 520CMD01 communication unit is the CMU module handling, the time base and the internal data base. The
of the RTU520 product line. controller acts as master for the serial I/O bus (WRB).
The essential tasks are:
System relevant configuration files are stored in the
• Managing and controlling of the RTU520 I/O
non-volatile flash memory card (removable SD-card™)
modules via the serial I/O bus
in order to guarantee a valid system configuration
• Reading Process events from the input modules.
after Power on Reset (PoR).
• Send commands to the output modules.
• Communicating with control systems and local HMI An optional battery buffered RTC is used to keep an
systems via the serial interfaces (RS232) and the exact time during power off state.
Ethernet 10/100BaseT interface.
• Communication with Sub-RTU’s, IED’s or The communication unit provides the following
multimeter devices via the interfaces (RS485) and interfaces:
the Ethernet interface. • Communication Port 1 (CP1): a serial interface
• Managing the time base for the RTU520 product according RS232C with RJ45 connector.
line station and synchronizing the I/O modules. • Communication Port 2 and 3 (CP2 & CP3): serial
• Handling the dialog between RTU520 product line interfaces according RS485 with RJ45 connector.
and Web-Browser via the LAN interfaces. • Ethernet interface (E1): 10/100BaseT with RJ45
The communication unit will be mounted on a DIN-rail, connector.
together with the power supply module and the I/O • Interface X1 for power supply to the power supply
modules. The communication unit is able to handle unit 520PSD01.
Ethernet- and UART character based communication • Interface X2 for communication unit with the
protocols. RTU520 I/O modules.
• USB 2.0 device interface for diagnosis and
The unit is available in 2 versions: maintenance purposes.
• R0001: without battery buffered real time clock • WRB I/O bus interface for local communication
(RTC) with the I/O-modules
• R0002: with battery buffered real time clock (RTC)
Technical data USB interface
In addition to the RTU500 series general technical
Type USB 2.0 device, low and
data, the following applies: full speed (max. 12 MBit/s)

Main Processing Unit MPU


Current consumption for power supplied via WRB
CPU ARM9, AT91SAM9260 @ bus
200 MHz
5 V DC max. 300 mA
RAM 64 MByte
±15 V DC --
NAND Flash 4 GByte
18/ 24 V DC --

SD card
Connector SD card slot (push push) Signaling by LEDs
Type SD 2.0, class 2 ERR (red) ON: RTU in error state
Capacity 4 GByte Flashing: RTU in warning
state
Real time clock RTC (Backup)
For more details see
Battery Lithium 3 V DC, CR2032 RTU500 series Function
Time resolution 1 sec, 1ms with timesync Description
Battery lifetime > 10 years RUN (green) Communication module in
operation
Free running ± 50 ppm
WRB (green) Transmission on to the I/
O bus
Real time clock RTC (R0002 only) Tx Transmit data on serial
communication ports CP
Battery Lithium 3 V DC, CR2032
Rx Receive data on serial
Time resolution 1 sec
communication ports CP
Battery live time > 10 years
SP Ethernet communication
speed:

Serial interface CP1 ON: 100 Mbit/s


Connector RJ45
OFF: 10 Mbit/s
Type RS232C
L/A Link up (ON) / Activity
Bit rate 100 bit/s - 38.4 kbit/s (Flashing) on Ethernet
Signal lines GND E2/102 interface E
TxD D1/103

RxD D2/104 Mechanical layout


RTS S2/105 Dimensions 35 mm x 98 mm x 117 mm
(Width x Height x Depth)
CTS M2/106
Housing type Plastic housing (V-0), IP20,
DTR S1.2/108 RAL 7035 light gray
Mounting DIN rail mounting
DCD M5/109
EN 50022 TS35: 35 mm x
Level typical: ± 6V 15 mm or 35 mm x 7.5 mm
Weight 0.17 kg
Serial interfaces CP2 and CP3
Connector RJ45
Immunity test
Type RS485
Electrostatic discharge 8 kV air / 6 kV contact
Bit rate 300 bit/s - 38.4 kbit/s
IEC 61000-4-2 (level 3)
Level ∆ = 3V (typical)
Performance criteria A
Ethernet interface E1 Radiated Radio-Frequency 10 V/m (level 3)
Electromagnetic Field
Connector RJ45 IEC 61000-4-3 Performance criteria A
Type IEEE 802.3, 10/100BaseT Electrical Fast Transient / 4 kV (level X)
Burst
IEC 61000-4-4 Performance criteria A
USB interface
Connector USB Type B (configuration
interface)
Immunity test
Surge 2 kV (level 3)
IEC 61000-4-5
Performance criteria A
Conducted Distur- 10 V (level 3)
bances, induced by Radio-
Frequency Fields Performance criteria A
IEC 61000-4-6
Damped oscillatory wave 2.5 / 1 kV (level 3)
IEC 61000-4-18
Performance criteria A

Environmental conditions - climatic


Operating temperature -25 °C ... 70 °C
EN 60068-2-14
Start up -40 °C
EN 60068-2-1
Max. operating temper- +85 °C
ature, max. 96h
EN 60068-2-2
Relative humidity 5 ... 95 %
EN 60068-2-30 (non condensing)

Ordering information
520CMD01 R0001 1KGT031900R0001

without battery buffered


RTC
520CMD01 R0002 1KGT031900R0002

with battery buffered RTC


ABB Power Grids Germany AG We reserve the right to make technical We reserve all rights in this document and in ABB is a registered trademark of ABB
changes or modify the contents of this the subject matter and illustrations contained Asea Brown Boveri Ltd. Manufactured
1KGT 150 882 V005 1

P.O. Box 10 03 51 document without prior notice. With therein. Any reproduction, disclosure to third by/for a Hitachi Power Grids company.
68128 Mannheim, Germany regard to purchase orders, the agreed parties or utilization of its contents – in whole
particulars shall prevail. ABB Power or in parts – is forbidden without prior written
Grids Germany AG does not accept any consent of ABB Power Grids Germany AG.
responsibility whatsoever for potential © 2020 Hitachi Power Grids
errors or possible lack of information in All rights reserved
hitachiabb-powergrids.com/rtu this document.

You might also like