Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

BGAS PAINTING INSPECTOR

Tick the correct answer from the choice

1. Other name for rust


a. Sulphur reducing bacteria
b. Hydrous iron oxide
c. Mill scale
d. Wustite
2. is more electro negative in given list
a. Silver
b. Graphite
c. Magnesium
d. Titanium
3. The mill scale forms at
a. Upto 650c
b. Excess 5800c
c. Detect Millscale
d. Below 5800c

4. Atom aqquire electric charge by ______


a. Polarization
b. Salts
c. Acid
d. Temperature
5. Picture of

a. Cu slag
b. shots
c. garnets
d. metallic grit
6. Surface profile needle gauge calibrated by
a. Flat smooth plate
b. Permanent record
c. Curved surface
d. Using replica tape
7. Picture of micrometer with testex

a. b. .c. d.
BGAS PAINTING INSPECTION GRADE II 1
8. Picture of comparator

a. b. c. d.

9. Rust grades A,B,C,D

(Total 7 question from this)

10. Abrasive blast grades


a. Sa1
b. Sa2
c. Sa2.1/2 & Sa 3
d. All the above
11. abrasive blast pressure measured by
a. Banana gauge
b. Hegman gauge
c. Hypodermic needle gauge
d. Surface profile gauge
12. Footners duplex system pickling followed by passivation us
a. Good Opacity
b. Sulphuric acid & phosphoric/chromic acid
c. Cohesive Strength
d. Porous Film
13. Test used in marine environment
a. Millscale
b. Silver nitrate test
c. Ultra violet test
d. powder
14. Cause chemical reaction between paint & supstrate
a. Stripe coat
b. Hydrous iron oxide
c. Chloride
d. Passivation
15. Linear polymer need what element for polymorization
a. Carbon
b. High Solid Epoxy
c. Oxygen
d. Urethane

BGAS PAINTING INSPECTION GRADE II 2


16. Which is saturated oil
a. Safflower oil
b. Tung oil
c. Castor oil
d. Soya oil
17. Property of pigment
a. Dry film thickness
b. Cases impermeability
c. Matt Film
d. peak to trough height
18. Which is non toxic from list
a. Red lead
b. Coal tar
c. Titanium dioxide
d. Zinc phosphosilicate
19. MIO needs for moisture resistance
a. Oxide
b. Haematite
c. Mill scale
d. Wustite
20. Read the near CPVC
a. Critical pigment volume concentration
b. Giving good resistance to water permeation
c. Velocity of the particles
d. Low cohesive strength
21. paint if stirred change to normal liquid
a. Critical pigment volume concentration
b. Thixotropic
c. Density of the paint
d. Low cohesive strength
22. need heavy metal salts for oxidation
e. Zinc rich epoxy
f. Driers
g. Urethane
h. Methyl ethyl ketoxime
23. Aluminium primer contains
e. zinc
f. phosphoric acid
g. Natural resin
h. Pickling
24. The gas in pipes,is much cooler than ambient temp and forms on the pipes
e. Condensation
f. Profile roughness
g. Zinc silicate
h. Grease
25. Which material is used for above 1510 c
e. Chlorinated rubber
f. Zinc silicate
g. Phenolic resins
h. Oils

BGAS PAINTING INSPECTION GRADE II 3


26. Which can’t be used as moisture born
a. Sa1
b. Oils
c. Matt Film
d. Sa3
27. Direct charge mill’s
a. Ball mill & Attritor mill
b. Single roll mill & Triple roll mills
c. Ball mill & Sand mill
d. Pearl mill & Colloid mill
28. Picture of attritor mill

a. b. c. d.

29. Flash point determination need


a. Density
b. Indirect heating
c. Direct heating
d. Internal source
30. (e) Density =mass/?
e. volume/weight
f. volume/mass
g. Gravity/weight
h. mass/volume
31. Unit of density
a. poise
b. Gm/cc
c. stoke
d. centi poise
32. Other device for density measurment
e. Flow cup
f. Krebs stormer
g. Densito meter
h. Kinematic viscosity
33. Specific gravity (or) relative density has units
a. Gm/cc
b. No
c. Yes
d. Seconds
34. Device for fineness of grind
a. Eccentric wheel
b. Rotothinner
c. Conventional spray
d. Hegman grind gauge

BGAS PAINTING INSPECTION GRADE II 4


35. Picture of hegman grind gauge

a. b. c. d.

36. Device used for measuring the viscosity of thixotrophic paints


a. Flow viscometer
b. Comb gauge
c. Rotational viscometer
d. Eccentric wheel
37. Flow viscometer needs to measure
e. Poise
f. Seconds
g. Stoke
h. Density
38. The concentric outer rims of eccentric wheel rotated
a. Perpendicular
b. Circumference
c. Not rotated
d. Longitude
39. Picture of PIG gauge

a. b. c. d.

40. Plastic shim -banana gauge


a. Electrically insulated
b. Metel piece
c. Magnetically insulated
d. No use
41. Flexibility test picture

a. b. c. d.

BGAS PAINTING INSPECTION GRADE II 5


42. BK Drying recorders picture

a. b. c. d.

43. Black & white fused plate picture

a. b. c. d.

44. Device used for adhesion test


i. Flow cup
j. Cross cut test
k. Eccentric wheel
l. Hegman grind gauge
45. picture of dolly

a. b. c. d.

46. When will use hygrometer


a. Measure evaporation rate
b. Flash point
c. Air temperature
d. Adhesion
47. In whirling hygrometer, what will you note first Dry or wet bulb temperature
a. Humidity
b. Dry bulb temp
c. Wet bulb temp
d. Both measured
48. In impressed current system, national grit connected to
a. Positive
b. Ground
c. Direct charge
d. Indirect

BGAS PAINTING INSPECTION GRADE II 6


49. Must not be used in B-gas site
i. Brush
j. Roller
k. Airless spray
l. Spray
50. Makes shearing action
a. Conventional spray
b. Roller
c. Brush
d. Spray
51. Thickness of galvanising
m. 200 microns
n. 100 micron
o. 125 microns
p. 30-75 microns
52. Gold leaf test
a. Detect moisture
b. Residual tack
c. Covering power
d. Seconds
53. Flexibility
a. Ferromagnetic supstrate
b. Conical mandrel
c. Opacity
d. Accuracy
54. Foreman’s gauge accuracy
a. + 15%
b. + 1.5%
c. + 12%
d. + 5%
55. Dragger tube and bellow monitoring
a. Humidity
b. Toxicity
c. Opacity
d. Flexibility

BGAS PAINTING INSPECTION GRADE II 7


56. BS 1710
m. Method of test for paints
n. Prepration of steel supstrate
o. Specification for identification of pipelines
p. Code of practice for safety during blast cleaning operations.
57. Specification is
a. A specify way to perform an activity
b. A document providing binding legislative rules that is adopted
c. Document established by consensus
d. The document that prescribes the requirement with which the product
58. Harmful or irritant printed

a. b. c. d.

59. IGE SR 21
a. Schedule of paint colour’s for building purposes
b. Code of practice for safety during blast cleaning operations.
c. Prepration of steel supstrate
d. Specifications for test sieves
60. Lightness is identify by
a. Numbered
b. Blue
c. Capital letters
d. Codings
61. Component coating with zinc, thickness
a. Approximately 150 microns
b. 60 micons
c. Approximately 100 microns
d. Approximately 425 microns
62. Coating thickness above 0.5 mm used to
a. Conical mandrel
b. Wet sponge pinhole detector
c. Toxicity
d. High voltage holiday detector
63. DFT 300-500 microns, voltage setting is
a. 9 V
b. 300 V
c. 90 V or 67 ½ V
d. 60 V
64. Pinhole detection operates upto
a. Above 500 microns
b. Less than 600 microns
c. Less than 500 microns
d. Above 625 microns

BGAS PAINTING INSPECTION GRADE II 8


65. WFT would be needed, give 50 microns DFT using a paint with a VS% of 65% ?
a. 90 microns
b. 76.92 microns
c. 45.03 microns
d. 59 microns

COATING FAULTS

66. Picture is
a. Cissing
b. Bittiness
c. Cracking
d. Ropiness

67. .Picture is

a. Cissing
b. Cratering
c. Cracking
d. Orange peel

68. .Picture is

e. Cissing
f. Bittiness
g. Sagging
h. Flaking

69. .Picture is

i. Wrinkling
j. Flaking
k. Cissing
l. Sagging

BGAS PAINTING INSPECTION GRADE II 9


70. .Picture is

m. Ropiness
n. Flaking
o. Run & Sag
p. Cracking

71. .Picture is

q. Ropiness
r. Flaking
s. Cissing
t. Wrinkling

72. Picture is

u. Ropiness
v. Flaking
w. Run-Sag
x. Cracking

BGAS PAINTING INSPECTION GRADE II 10


PA 10
1. if you find contractor using re crushed cu slag
a. continue the work
b. report to client
c. stop the work and report to engineer
d. no problem

2. if you find dust in painting


a. continue the work
b. clean, reblast, recoat
c. measured dft
d. apply coatings

3.paint shall be normally applied when RH


a. above 180 %
b. above 89 %
c. below 180 %
d. below 89%

4.the paint must overlap minimum


a. 100 mm
b. 65 mm
c. 120 mm
d. 90 mm

5.alternate complient system


a. mid coat
b. water borne paints
c. damp surface
d. final coat

6.table spa 1e –i) solvent based microns (4 coat)


a. 260
b. 220
c. 265
d. 225

BGAS PAINTING INSPECTION GRADE II 11


7.table spa 1e –ii) water borne acrylic microns (4 coat)
a. 240
b. 225
c. 261
d. 255

8.surface finish need for damp surface (spa 4a)


a. sa 1
b. sa 2
c. sa 2 1/2
d. sa3

9.paint for damp surface


a. solvent
b. moisture cure polyurethane
c. vinyl
d. alkyds

REFER
1.Damp surface - definition
2.Etch primer – definition
3.Read 7.1 – 1’st two lines
4.Read 26.2

BGAS PAINTING INSPECTION GRADE II 12

You might also like