CHEQUEO COLUMNA FUERTE - VIGA DEBIL

Según la NSR10
Elaborado por: Ing. Jairo Alberto Rangel Vera
MP 54202 - 108552 NTS

Clockwise Counter-Clockwise
Column Strength Minimum
Node LCB Remark
(kN*m) Beam Strength Beam Strength Ratio
Ratio Ratio
(kN*m) (kN*m)
Acceptance Limit for SCWB C/B Flexural Capacity Ratio: 1.2
Angle for Seismic Load Combination Result: 0 [Deg]
19 COMBO17 464.53 132.70 3.50 79.32 5.86 3.50 OK
20 COMBO17 492.41 215.63 2.28 108.76 4.53 2.28 OK
21 COMBO13 266.66 165.73 1.61 189.68 1.41 1.41 OK
25 COMBO17 501.93 212.03 2.37 212.03 2.37 2.37 OK
27 COMBO17 393.15 113.95 3.45 113.95 3.45 3.45 OK
28 COMBO17 364.06 108.76 3.35 115.06 3.16 3.16 OK
63 COMBO17 436.06 208.94 2.09 136.30 3.20 2.09 OK
64 COMBO17 454.01 278.65 1.63 172.04 2.64 1.63 OK
65 COMBO13 329.56 272.60 1.21 165.73 1.99 1.21 OK
69 COMBO17 463.38 278.70 1.66 322.32 1.44 1.44 OK
71 COMBO17 379.83 136.30 2.79 113.95 3.33 2.79 OK
72 COMBO17 358.77 132.70 2.70 148.19 2.42 2.42 OK
115 COMBO17 393.48 208.94 1.88 136.30 2.89 1.88 OK
116 COMBO17 401.34 278.65 1.44 172.04 2.33 1.44 OK
117 COMBO15 335.37 270.54 1.24 165.73 2.02 1.24 OK
121 COMBO17 404.42 256.95 1.57 292.89 1.38 1.38 OK
123 COMBO17 365.52 136.30 2.68 113.95 3.21 2.68 OK
124 COMBO17 354.74 165.73 2.14 136.30 2.60 2.14 OK
125 COMBO17 378.90 165.73 2.29 165.73 2.29 2.29 OK
154 COMBO17 184.99 116.28 1.59 97.40 1.90 1.59 OK
155 COMBO17 186.00 116.28 1.60 97.40 1.91 1.60 OK
156 COMBO13 168.15 97.40 1.73 116.28 1.45 1.45 OK
160 COMBO17 184.37 97.40 1.89 116.28 1.59 1.59 OK
162 COMBO17 178.14 97.40 1.83 97.40 1.83 1.83 OK
163 COMBO17 175.25 116.28 1.51 97.40 1.80 1.51 OK
164 COMBO17 182.07 97.40 1.87 97.40 1.87 1.87 OK