Professional Documents
Culture Documents
ZJBENY Catalouge 2018 201811191535567238
ZJBENY Catalouge 2018 201811191535567238
ZJBENY Catalouge 2018 201811191535567238
for Photovoltaic
Email: benyi@zjbeny.com
Http: // www.zjbeny.com
If the models and specifications in this product catalogue is changed due to the change of products, we will not inform .
Scan it to website!
www.
zj
beny.
com
Leading Supplier for Solar Photovoltaic
Components
COMPANY
PROFILES
With each product is backed by the skills and service of dedicated team
of customer-focused specialists, we have been striving to provide high-
quality products for residential, commercial and utility-scale solar
projects, we strictly make the management as per the ISO9001:2008
Mission:
Making Solar PV Power System More Reliable and Safe
Value:
Honesty, Responsibility, Innovation
Faith:
People-oriented, creating value; Scientific management,
keeping developing
Quality policy:
Create the Best Products and Superb Service
Social Responsibility:
Devote us to improve the quality of life of the workforce and
BENY Electrical Production Base in Wenzhou their families as well as the local community and society at
large and to behave ethically in business and contribute to
economic development.
www.zjbeny.com
Making Superb Product ,Creating Top Brand MANUFACTURING
The Quality Management System, which includes this Policy, provides the
framework through which a formal and continuing program of review is adopted and fully
supported so that products, services and the effectiveness of systems, policies,
objectives and targets may be continually measured and improved as far as possible.
defines Quality as conformance to our Customers' needs, both internally and
externally, and as conformance to all defined quality system requirements.
Consequently, we recognise the value of our customers and the impact of our activities
upon them.
www.zjbeny.com
www.zjbeny.com
CONTENTS CERTIFICATE
BYH/BYT BR-30
Series DC Isolator Switches 02 PV DC Fuse Holder 41
BYT
Series DC Isolator Switches 05
BYS
Series DC Isolator Switches 12
BB1H-63
PV DC Isolator Switches 16
BH
Series PV DC Isolator Switches 19
BDH
Series PV DC Moulded Case Isolator Switch 22
DC Circuit Breakers 25
BB1-63
PV Mini Circuit Breakers 26
BB2-40
PV Mini Circuit Breakers 28
BD Series
PV DC Moulded Case Circuit Breaker 31
Safety
BD2 Series
PV DC Moulded Case Circuit Breaker 34
BUD-40/3
PV DC Surge Protection Device 42
www.zjbeny.com
www.zjbeny.com
BYH/BYT
Series DC Isolator Switches
BYH/BYT Series
DC Isolator Switches
Application
DC Isolator Switches
BYH/BYT Series DC Isolator Switch in plastic enclosure is applied to 1-
20kw residential and commercial PV systems,is installed between solar panels and
inverter.Arcing time less than 3ms is the key of the switch and safty.Top material
and highest PV test standard ensure high quality isolator switch and long working
Welcome to our website for more information:
life.
www.zjbeny.com
BYH-32 BYH-32MC4
BYT-32 BYT-32MC4
01 02
BYH/BYT Switching Configurations
DC Isolator Switches
PV DC Isolator Switches Type 2-pole 2-pole 4-pole 4-pole with Input 4-pole with Input 4-pole with Input
4 Paralleled on top and and
Poles Output bottom Output bottom Output on top
Parameter BYH-16/BYT-16 2 2H 4 4S 4B 4T
BYH-25/BYT-25 2 2H 4 4S 4B 4T
Electrical Characteristics
BYH-32/BYT-32 2 2H 4 4S 4B 4T
Type BYH-32 BYT-32
1 3 1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7
Function Isolator, Control
Contacts
Comply with IEC60947-3 Wiring graph
Pole 4P 2 4 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8
Max Rated Current 32A
Rated Working Voltage Ue 1000V DC 1200V DC
Switching
Rated Current In 32A example
Rated Insulated Voltage Ui 1000V DC 1200V DC
Rated Impulsed Voltage Uimp 8KV
Service Life/Cycle Operation
Mechanical 20000
Dimensions(mm)
Electrical 2000
Installation Environment BYH-32/BYT-32
Ingress Protection IP66
75.0
Storage Temperature -40°C~+85°C
Wiring Diagram
188.0
170.5
Contacts wiring Poles in Number of Type Number Weight
108.5
diagram 500V 600V 800V 1000V 1200V series Strings kg/PCS
100.0
178.5
78.5
1 3
16A 16A 16A 9A 7.5A 2 1 PE2 0.70
25A 25A 20A 11A 9A 2 1 PE2 0.70
32A 32A 23A 13A 13A 2 1 PE2 0.70 M25X1.
5
2 4 47.
0
188.0
242.0
170.5
100.0
178.5
108.5
25A 25A 25A 25A 25A 4 1 PEB 0.70
78.5
32A 32A 32A 32A 32A 4 1 PEB 0.70
2 4 6 8
99.0 Ø4.3
*Note: Recommend for MC4 Type
03 04
BYT
BYT Series
DC Isolator Switches
Application
Series DC Isolator Switches
DC Isolator Switches
BYT series DC Isolator Switches are applied to 1-20KW Inverter,
Controller, DC Combiner Box, used for Residential or Commercial PV solar power
system(on-grid/off-grid). Arcing time less than 3ms, that make PV solar system
effectively disconnected.
Welcome to our website for more information:
www.zjbeny.com
05 06
BYT Switching Configurations
DC Isolator Switches
Type 2-pole 2-pole 4-pole 4-pole with Input 4-pole with Input 4-pole with Input
PV DC Isolator Switches 4 Paralleled on top and and
Poles Output bottom Output bottom Output on top
BYT.1-16/ BYT.2-16 2 2H 4 4S 4B 4T
Parameter
BYT.1-25/ BYT.2-25 2 2H 4 4S 4B 4T
Electrical Characteristics BYT.1-32/ BYT.2-32 2 2H 4 4S 4B 4T
Function Isolator, Control
1 3 1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7
Comply with IEC60947-3, DC-21B
Contacts
Pole 4P Wiring graph
Max Rated Current 32A 2 4 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8
Rated Working Voltage Ue 1200V DC
Rated Current In 16A/25A/32A
Switching
Rated Insulated Voltage Ui 1200V DC example
Rated Impulsed Voltage Uimp 8KV
Service Life/Cycle Operation
Mechanical 20000
Electrical 500
Dimensions(mm)
Installation Environment
Size of Terminal Screw M4 BYT.1
48.6
Tightening Torque Nm 2.5
2
Maximum Cable Cross Sections mm 4-16
3(MAX:5mm)
Ingress Protection IP20
Storage Temperature -25°C~+85°C
121.2
Wiring Diagram
77.9
50.9
Contacts Poles in Number of Code Weight
Configuration 600V 800V 1000V 1200V series Strings kg/PCS
1 3 16A 16A 9A 2 1 DR2 0.23 60.5
25A 20A 11A 9A 2 1 DR2 0.23 77.9
32A 23A 13A 13A 2 1 DR2 0.23
2 4
221.5 95.4
58.4
78
60.6
95.4
07 08
PV DC Isolator Switches BYS Series
DC Isolator Switches
Application
DC Isolator Switches
S
BYS-63 DC isolator switch is applied to 1kw to 20kw PV systems.
The enclosure protection degree is IP66 for outdoor installation.
Feature
Compact structure
pre-wired DC Main Switch with MC4(optional)
UV resistant, IP66 enclosure
Arcing time < 3ms
"OFF" position Lockable
IEC60947-3 Standard
4P,6P
DC-21B
Ui:
1500V/
Uimp:
8kV
Appearance Introduction
1 Waterproof Plug 1
2 IP66 Ingress Protection 11
2
3 Sealed Plug
3
4 Type
5 Application Category 4
6 Rated Voltage 5
7 Rated Current 6
12
8 Knob 7
8
9 BE LOCKABLE
10 Electrical Diagram 9
11 Brand 10 13
12 ON
13 OFF
Parameter
BYS series isolator switch is new developed products ,which successfully Technical date Symbol Merit Unit
pass the IP66 inspection ,power frequency withstand voltage test, cycle Rated operational voltage(DC poles) Ue VDC
operation endurance etc.
Rated operational current(DC poles) Ie VDC
It successfully obtain certifications :UL ,TUV,CB,KEMA
Conventional free air thermal current Ith 63 A
Rated impulse withstand voltage Uimp 8 kV
Welcome to our website for more information:
Rated short-time withstand current(1s) Icw 8 kA
www.zjbeny.com
Rated short-circuit making capacity Icm 8 kA
Rated conditional short-circuit current 8 kA
Standard Short Circuit Rating 5 kA
High-Fault Short Circuit Rating 8 kA
Insulation voltage Ui 1500 V
Category DC DC-21B
Number of cycles of operation(With current) 3000times(6T Type is 2200 times only)
BYS-63
Number of cycles of operation(With current) 7000
Number of DC poles 4/6
Method of mounting Standard TH35-7.5 DIN rail mounting
Method of operating independent manual operation
Knob operation force max 1.4 Nm
Tightening torque terminal screws M4,-max.M4 1.2 1.8 Nm
Tightening torque panel mounting nut,min.-max. 2.5 3.0 Nm
Tightening torque M3 screw in the standard black knob,min.-max. 0.5 0.7 Nm
Ambient temperature allowed between -40to+70 ℃
Storage temperature allowed between -40to+85 ℃
Maximum relative humidity,without condensation at 20℃ 90 %
Pollution degree 2
Leading Manufacturer for IP rating terminals Ip66
PV Solution
09 10
BYS Series
Series DC Isolator Switches
BYS
PV DC Isolator Switches
Wiring Diagram
Contact DC-21B Rating Poles Number Type Weight
Configuration 600V 800V 900V 1000V 1200V 1500V in series of Strings Number kg/pcs
Welcome to our website for more information:
50A 2 1 BYS-63-2H 0.91 www.zjbeny.com
7 9 11
7 9 11
7 9 11
7 9 11
Switching Configurations
2-pole 2-pole 2-pole 2-pole 2-pole 4-pole
2-pole 2-pole
with Input with Input with Input with Input with Input with Input
Type 4Parlleled 4-pole 6-pole 6Parlleled
on top and and on top and and
poles poles
Output bottom Output bottom Output on top Output bottom Output bottom Output bottom
Part Number 2H 4 4S 4B 4T 6 3H 6S 6B 6T
1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11
Contacts
Wiring
diagram
2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 10 12 2 4 6 8 10 12 2 4 6 8 10 12 2 4 6 8 10 12 2 4 6 8 10 12
Switching
example
Dimensions(mm)
194.0
17.8
9.0
190.5
128.0
149
100.5
87.0
99.5
4 Poles 6 Poles
11 12
BYS Series
DC Isolator Switches
Application Wiring Diagram
DC Isolator Switches
BYS series DC isolator switch for PV system.Rated current is 5A to 63A, Contact DC-21B Rating UL Ratings UL508i Number Weight
S
Poles Type
Rated working voltage is 600V to 1500V. oudle design can match with many wire Configuration in series of Strings Number kg/pcs
600V 800V 900V 1000V 1200V 1500V 500V 600V 1000V
ways.Mounting:Standard Din Rail/Panel mounting/Fix installtion.
Appearance Introduction
1 Brand
2 Type 32A
3 OFF 30A 20A
8
Application Category 1
4
5 Insulation voltage 2 9
6 Rated impulse withstand voltage
10
7 Rated Current 3
8 ON 4
5 11
9 Certificate Symbol
6
10 Knob
7
11 Standard Code
BYS .1/.2 - 63 - 2H
.1:Panel 2
mounting 4/2H/4S/4T/4B
63A
.2:DIN rail 6/3H/6S/6T/6B
mounting 8
Parameter
Technical data Symbol Merit Unit
Rated operational voltage (DC poles) Ue
Rated operational current (DC poles) Ie
Conventional free air thermal current Ith 63 A 30A 20A
Rated impulse withstand voltage Uimp 8 kV
time withstand current (
Rated short- 1s) Icw 8 kA
Rated short-
circuit making capacity Icm 8 kA
Rated conditional short-circuit current 8 kA
Standard Short Circuit Rating 5 kA
High-Fault Short Circuit Rating 8 kA
Insulation voltage Ui 1500 V
Installation Environment
Utiizatin category DC DC-21B
Number of cycles of operation(With current) 3000 times (6T Type is 2200 times only)
Number of cycles of operation(Without current) 7000 times
Number of DC poles 1/2 / 3 / 4 / 6 / 8
Method of mountig Panel mounting Standard TH35-7.
5 DIN rail mounting
Method of operatin independent manual operation
Knob operation force max. 1.4 Nm
Tightening torque terminal screws M4 , min. - max.M4 1.2 1.8 Nm
Tightening torque panel mountig nut, min. - max. 2.5 3.0 Nm
Tightening torque M3 screw in the standard black knob, min. - max. 0.5 0.7 Nm
Ambient temperature allowed between -40 °C ~ +70°C °C
Storage temperature allowed between -40°C ~ +85°C °C
Maximum relative humidity, without condensation at 20°C 90 %
Pollution degree 2
IP rating terminals IP20
IP rating gland of the shaft in case of single hole panel mounting IP66
13 14
BB1H-63
PV DC Isolator Switches
Dimensions(mm)
37.5
M16.0X1.5
45.0
N is the number of layers in the switch
M16.0X1.5
19.5
16.0
60.0
Gasket 1.5
32.5+(Nx10.5)±1%
60.0
68.0
78.0
32+(Nx10.5)±1%
11.8
2.0
11.8
47.0
47.0
16±0.2
0
16±0.2
0
12±00.2 12±00.2
PANEL
PANEL
CUTOUT
CUTOUT
15 16
BB1H-63
PV DC Isolator Switches
Application Wiring Method
DC Isolator Switches
BB1 Series PV DC Isolator switches are mainly be used in PV solar power
Pole 1P 2P 3P 4P
system, which are applied for DC solar combiner box, controller etc. The Max
voltage up to 1200V DC, current up to 63A ,with the function of effective
disconnection and Anti-reflux protection. Scientific design of arc-extinguishing
S system keep PV system more safe.
Type
Appearance Introduction
1 Brand
2 Type
3 Rated Current
1 1 3 1 3 1 3 5 1 3 5 1 3 5 7
Rated Voltage -/+ 1 3 5 7
4 1 + -
Load Load -/+ Load
35.5
Type Instruction
17.8 53 71
Nonpolarity
BB1 H - 63 4P 25 1200V
Functions: Unfrequent operation and
Isolation
Rated Current: Up to 63A
Product Max Rated Rated Rated
81.2
111
Rated Voltage: 1200V DC Pole
Code Current Current Voltage
96.5
96.5
Flash Barrier Keep System More Safe
Comply with :IEC60947-3/GB14048-3
PV DC 1P 300V
25A
2P 600V
Isolator 63A 40A
3P 900V
Switches 63A
4P 1200V
45
Parameter
Electrical Characteristics
Type BB1H-63
Comply With IEC60947-3/GB14048.3
74
Pole 1P 2P 3P 4P
52
Rated Working Voltage Ue 300V DC 600V DC 900V DC 1200V DC
50
Max Rated Current 63A
Rated Current In 25A,40A,63A
Rated Insulated Voltage Ui 1200V DC 36.2
17 18
BH
BH Series
PV DC Isolator Switches
Application
Series PV DC Isolator Switches
DC Isolator Switches
BH series PV DC Isolator Switches are mainly used in large solar power
system, such like solar DC combiner box ,inverter and DC power distribution
cabinet. Rated voltage up to 1000V DC, Rated Current up to 250 A with the function
of effective disconnection.
Type Instruction
BH - 1000V 250 2P
PV DC 600V 2P
250
Isolator Switch 1000V 4P
Parameter
Bh Series Pv Dc Isolator Switches
Pole 2P 4P
Electrical Characteristics
Rated Working Voltage Ue 600V DC 1000V DC
Max Rated Current 250A 250A
Rated Current In 160A 200A 250A 160A 200A 250A
Rated Insulated Voltage Ui 600V DC 1000V DC
Rated Impulsed Voltage Uimp 8KV 12KV
Rated Short-time Withstand Current 1s 8KA 8KA
Rated Thermal Current Free Air 200A 200A 250A 200A 200A 250A
2P (Ambient Temperature:40℃)Enclosed Air 160A 200A 250A 160A 200A 250A
Service Life/cycle Operation
Mechanical 10000 10000
Weight(without Accessory) kg 0.8 1.5
19 20
BH
BDH
BDH Series PV DC Moulded Case Isolator Switch
Series PV DC Isolator Switches
Wiring Method
Contacts wiring graph Pole Rated insulation voltage Ui Max Rated Current A Welcome to our website for more information:
www.zjbeny.com
4P DC 1000V 250A
2P DC 600V 250A
Dimensions(mm)
110.5
20 180.5
68 20 35 68
25
34.5 34.5
Ø26.5 Ø26.5
6 6
100 100
60 63
Installation
Ø5...6mm
2,5mm 0,1 in
0.8 Nm 7Ib.in
M5
3/16
TORX T15 1.5NM/13.2in-Ibs
0.8Nm
360° 7 Ib.in
360°
21 22
BDH Series
PV DC Moulded Case
Isolator Switch Application
Type BDH-125 BDH-250 BDH-400 BDH-630
DC Isolator Switches
BDH series PV DC Moulded Case Isolator Switches are mainly used in
S large solar power system, such like solar DC combiner box ,inverter and DC power
distribution cabinet. Rated voltage up to 1200V DC, Rated Current up to 630A with
the function of effective isolator.
Picture
Appearance Introduction
1 Brand
2 Type
3 Rated Current
1
4 Rated Voltage
2
5 Rated Short-time Withstand Current Wiring Method
3 7
6 Standard Code 4 8
Type Y MCCB Type S MCCB
7 Certificate Symbol 5
8 Wiring Diagram 6
Contacts
Wiring graph
Type Instruction
114
92
85
110
89
Parameter
79
BDH series PV DC Moulded Case Isolator Switch 150.5
Type BDH-125 BDH-250 BDH-400 BDH-630 30
122 165 35 140
Pole 4P
Max Rated Current 125A 250A 400A 630A
Electrical Characteristics
Rated Working Voltage Ue 1200V DC
60/80 125/160 250/300/315
Rated Current In(A) 400/500/630
100/125 200/250 350/400 50
282
70
Rated Insulated Voltage Ui 1200V DC
Rated Impulsed Voltage Uimp 8KV
1 Min Power Frequency Withstand Voltage 3.8KV
Control And Indication
Direct (RHD) Optional
Control Manual Extended(ERH) Optional
Mode
153
Optional
160
MOD
107
115
105
Shunt Release (SHT) Optional
98
Auxiliary Release Optional
Terminal End Cover Yes
258
Interphase Barriers Yes 282
Service Life/Cycle Operation 198
23 24
BB1-63
BB1-63
PV Mini Circuit Breakers
Application
PV Mini Circuit Breakers S
DC Circuit Breakers
4 Rated Voltage
1
5 Ultimate Breaking Capacity
2
6 Certificate Symbol
3
7 Standard Code
8 Indicator 4 8
9 Wiring Diagram 5 9
6
7
Type Instruction
Parameter
Electrical Characteristics
Type BB1-63
Comply with IEC60947-2/GB14048.2
Pole 1P 2P 3P 4P
Rated Working Voltage Ue 300V DC 600V DC 900V DC 1200V DC
Max Rated Current 63A
Rated Current In 3A, 4A, 6A,10A,13A,16A,20A,25A,32A,40A,50A,63A
Rated Insulated Voltage Ui 1200V DC
Rated Impulsed Voltage Uimp 6KV
Ultimate Breaking Capacity Icu 6KA
Run Breaking Capacity Ics 100%
Tripping Type Thermal Magnetic Type
Service Life/cycle Operation
Actual Value 20000
Mechanical
Standard Value 8500
Actual Value 4000
Electrical
Standard Value 1500
Installation Environment
Ingress Protection All Sides IP40 ,Connection Terminal IP20
Terminal Cross Section 2.5-25mm 2
Working Temperature -25℃~+70℃
Storage Temperature -40℃~+85℃
Resistance to Humidity And Heat Ⅱ(when Humidity arrived to 55℃,
Relative Humidity95%)
Resistance to Shock 2.6 IEC60068
Resistance to Impack 2.27 IEC60068
25 26
BB1-63
BB2-40
PV Mini Circuit Breakers
PV Mini Circuit Breakers
Wiring Method
Pole 1P 2P 3P 4P Welcome to our website for more information:
www.zjbeny.com
Type
1 1 3 1 3 1 3 5 1 3 5 1 3 5 7
-/+ 1 3 5 7
+ - -/+ Load
Load Load
Contacts
Wiring graph
Load Load
+/- Load +/- -/+ +/- -/+ +/-
Load +/- -/+ +/- -/+
2 2 4 6 8 2 4 6 8
2 4 2 4 2 4 6 2 4 6
B curve : (
4.4-6.6)In
t(s)
10 000
5 000
2 000
1 000
500
200
100
50
20
10
5
2 204.0 196.0
1 110.0
.5
.2
.1
.05
.02
.01 99.5
.005
.002
.001
.5 .7 1 2 3 4 5 7 10 20 30 50 70 100 200 300 I/ln
Dimensions(mm)
35.5
45
17.8 53 71
74
81.2
111
52
50
96.5
96.5
36.2
27 28
BB2-40
PV Mini Circuit Breakers
Application Characteristic Curve
S
BB2-40 Series PV Mini Circuit Breakers are mainly applied to DC solar B curve : (
4.4-6.6)In
combiner box ,Controller etc. The main function include overload protection ,Anti- t(s)
reflux protection and short-circuit protection. Scientific design of arc-extinguishing 10 000
5 000
system keep solar system more safe. Max Voltage up to 1500V DC, current up to 40A. 2 000
1 000
500
Appearance Introduction 200
100
50
1 Brand 20
10
2 Type 5
DC Circuit Breakers
3 Rated Current 2
1
4 Rated Voltage 1 .5
.2
5 Standard Code 2
.1
6 Ultimate Breaking Capacity .05
3 .02
7 Indicator .01
7 .005
8 Wiring Diagram 4
8 .002
5 .001
.5 .7 1 2 3 4 5 7 10 20 30 50 70 100 200 300 I/ln
6
Contacts
Parameter Wiring graph
Electrical Characteristics Load Load
+/- Load +/- -/+ +/- -/+ +/-
Load +/- -/+ +/- -/+
BB2-40 2
Type 2 4 2 4 2 4 6 2 4 6 2 4 6 8 2 4 6 8
74
Installation Environment
81.2
111
Ingress Protection All Sides IP40 ,Connection Terminal IP20
52
50
96.5
96.5
Terminal Cross Section 2.5-25mm 2
Working Temperature -25℃~+70℃
Storage Temperature -40℃~+85℃ 36.2
29 30
BD
BD Series
PV DC Moulded Case
Circuit Breaker Application
Series PV DC Moulded Case Circuit Breaker
BD series PV DC Moulded Case Circuit Breaker (MCCB) are mainly used
S
in large solar power system, which are applied for solar DC combiner box ,inverter
and DC power distribution cabinet. Rated voltage up to 1000V DC, current up to
630A , with the function of overload protection and short-circuit protection.
1 Brand
DC Circuit Breakers
2 Type
3 Rated Current
1
4 Rated Voltage
2
5 Breaking Capacity 8
3
6 Operation Breaking Capacity 4 9
7 Standard Code 5 10
8 Certificate Symbol 6
9 Wiring Diagram 7
10 Characteristic Curve
Type Instruction
Parameter
BD series PV DC MCCB
Type BD-125 BD-250 BD-400 BD-630
Pole 4P 4P 4P 4P
Max Rated Current 125A 250A 400A 630A
Electrical Characteristics
Rated Working Voltage Ue 1000V DC 1000V DC 1000V DC 1000V DC
63/80 125/160 250/300/315
Rated Current In(A) 400/500/630
100/125 200/250 350/400
Rated Insulated Voltage Ui 1000V DC
Rated Impulsed Voltage Uimp 8KV
1 Min Power Frequency Withstand Voltage 3.8 KV 3.8 KV 3.8 KV 3.8 KV
Ultimate Breaking Capacity Icu 20 KA 20 KA 20 KA 20 KA
Run Breaking Capacity Ics 15 KA 15 KA 15 KA 15 KA
Protection
Tripping Type Thermal Magnetic Type
Control And Indication
Direct (RHD) Optional
Control Manual Extended(ERH) Optional
Mode
MOD Optional
Shunt Release (SHT) Optional
Auxiliary Release Optional
Terminal End Cover Yes
Interphase Barriers Yes
Service Life/Cycle Operation
Mechanical 14000 14000 5000 5000
Electrical 5000 5000 1500 1500
Size (L x W x H) 150x122x92 165x140x89 258x198x107 282x282x115
Ingress Protection All Sides IP40 ,Connection Terminal IP20
Installation Environment
Comply With IEC60947-2/GB14048.2
Storage Temperature -45°C~+70°C
31 32
BD Series
BD2
Series PV DC Moulded Case Circuit Breaker
PV DC Moulded Case Circuit Breaker
Characteristic Curve
S 10000
7200
3600 Welcome to our website for more information:
2000 www.zjbeny.com
1000
500
最大Max.
200
100
50
20
10
5
2
1
.5
.2 最小Min.
.1
.05
.02
.01
.005
.002
.001
.5.7 1 2 3 4 5 7 10 15 20 30 40 I/IR
Picture
Contacts
Wiring graph
Dimensions(mm)
35
30
114
132.5
126
92
85
110
89
79
150
44 50 282
70
194
153
160
107
98
115
105
258
198 282
33 34
BD2 Series
PV DC Moulded Case
Circuit Breaker Application Characteristic Curve
S 10000
S
BD2 series PV DC Moulded Case Circuit Breaker (MCCB) are mainly 7200
3600
used in large solar power system, which are applied for solar DC combiner box 2000
1000
,inverter and DC power distribution cabinet. Rated voltage up to 1500V DC, current 500
最大Max.
up to 400A , with the function of overload protection and short-circuit protection. 200
100
50
20
Appearance Introduction 10
5
2
1
1 Brand .5
2 Type .2 最小Min.
.1
3 Rated Current .
05
1
4 Rated Voltage .02
2 .01
5 Breaking Capacity 3 8 .005
.002
6 Operation Breaking Capacity 4 9 .001
7 5 10 .5.7 1 2 3 4 5 7 10 15 20 30 40 I/IR
Standard Code
8 Certificate Symbol 6
7 Type BD2-225T BD2-225S BD2-400
9 Wiring Diagram
10 Characteristic Curve
Dimensions(mm)
Parameter BD2-225T BD2-225S
BD2 series PV DC MCCB 120 92
136 121
95
Type BD2-225T BD2-225S BD2-400 44 95
87 87
Pole 2P 3P 3P
Max Rated Current 225A 225A 400A
Electrical Characteristics
Rated Working Voltage Ue 1000V DC 1500V DC 1500V DC
In(A) 80A/100A/125A/ 80A/100A/125A/ 250A/300A/
Rated Current 160A/200A/225A 160A/200A/225A 350A/400A
180 159 180 159
Rated Insulated Voltage Ui 1000V DC 1500V DC 1500V DC
Rated Impulsed Voltage Uimp 8KV
1 Min Power Frequency Withstand Voltage 3.8 KV
Ultimate Breaking Capacity Icu 20 KA
Run Breaking Capacity Ics 15 KA
Instantaneous action 8In
Protection
Tripping Type Thermal Magnetic Type BD2-400
Control And Indication
Direct (RHD) Optional 204 165
Control Manual Extended(ERH) Optional 70
119
Mode 106
MOD Optional
Shunt Release (SHT) Optional
Auxiliary Release Optional
Terminal End Cover Yes
Interphase Barriers Yes
Service Life/Cycle Operation
Mechanical 8500 8500 4000 258 194
Electrical 1500 1500 1000
Size (L x W x H) 180x92x87 180x135x87 258x204x119
Ingress Protection All Sides IP40 ,Connection Terminal IP20
Installation Environment
Comply With IEC60947-2/GB14048.2
Storage Temperature -45°C~+70°C
35 36
BUD-40/3
BUD-40/3
PV DC Surge
Protection Device
Application
PV DC Surge Protection Device DC Surge Arrester BUD-40/3 is a Type 2 DC Surge Protection Device for
DC side to protect the terminal devices in PV system from over voltage, like solar
panels or inverters. Available for 600Vdc ,1000Vdc,1500Vdc.
*The only RoHS compliant DC SPD in China
*EN 50539-11 PV standard
Welcome to our website for more information:
www.zjbeny.com Appearance Introduction
1 Brand
2 Type
3 Max. Discharge Current I max
1 7
4 Nominal Discharge Current I n
2
5 Voltage Protection Level U p
3
6 Max. Continuous Operating Voltage U cpv 4
7 Indicator 5 8
8 Standard Code 6 9
9 Certificate Symbol
BUD - 40 / 3 1000V RC
Parameter
PV DC Surge Protection Device
Modules 3 modules
Suitable For Use in All Photovoltaic Standard EN 50539-11 Type 2
Systems Electrical Characteristics
Prewired Modular Complete Unit, Open Voltage Uoc Max 1000V
Consisting of A Base Part and Plug-in Max Continuous Operational Voltage Uc 1000V
Protection Modules Nominal Discharge Current In(8/20)µs 20KA
Plug-in Protection Module, Easily Maximum Discharge Current Imax(8/20)µs 40KA
Installation and Maintainance Voltage Protection Level Up Up ≤3.8KV
High Energy Varistor, Response Time Response Time tA ≤25ns
Indication
Less Than 25 Nanosecond
Operating State/fault Indication Green/Red
Optional Remote Signalling
Plug-in Protection Module YES
Contact(FM) for Monitoring Device
Type of remote signalling contact changeover contact
(Floating Changeover Contact)
Remote Signalling Max Working Voltage 30V DC
Din Rail Mounting TH35-7.5/DIN35
Remote Signalling Max Working Current 1A
Comply with :EN 50539-11 Connection And Installation
Cross-sectional area min. 1.5 mm 2 solid / flexible
Cross-sectional area max. 35 mm 2 stranded / 25 mm 2 flexible
Connection mm 2 By screw terminal 4-25 mm 2
Main Circuit 2.5
Torque(Nm)
Remote Contact 0.25
For mounting on 35 mm DIN rails
Place of installation indoor installation
Degree of Protection IP20
Installation Environment
Operating Temperature Range TU -40℃~+80℃
Relative Humidity 30%~90%
Weight kg 0.36
37 38
BR-30
BUD-40/3
PV DC Surge
Protection Device
Principal Drawing
PV DC Fuse Holder
BU-40/3 Switch-station BU-40/3 Converter
F
L+ AC
Generator
F
L- DC Welcome to our website for more information:
www.zjbeny.com
Wiring Method
Dimensions(mm)
46.5
84
89
35
5.5 44
53.5
69.5
39 40
BR-30
PV DC Fuse Holder
Application
BR-30
S
PV DC BR-30 Fuse Holder was designed and manufactured , complying PV DC Fuse Holder
with the standard IEC60947-3. The Rated Current up to 30A,rated voltage up to
1000V DC. It applied for PV DC combiner box, inverter etc, with the main function of
over-current protection and effective disconnection. Installation
Appearance Introduction
1 Brand
2 Type
3 Rated Current
4 Rated Voltage
5 Fuse Size 1 咔嗒!
下拉
6 Electrical Diagram 2
7 Status Indicator 3 6
4 咔嗒!
5
7 插入
Replacement Fuse
Type Instruction
Photovoltaic Applications
BR - 30 1000V
Max Breaking Capacity up to
20KA,Effective Protection
The Innovation Replacing Fuse Link
Product Max Rated Rated
Touch-safe Code Current Voltage
DC Fuse Holder
Led Indicator, Reminding Fuse Link
Replacement
PV DC
Be Suit for 10x38mm Fuse Size 30A 1000V
Fuse Holder
Comply with :IEC6094-3
Parameter
PV DC BR-30 Fuse Holder
Pole 1P
According to IEC 60947-3
Electrical Characteristics
Rated Working Voltage Ue 1000V DC
Dimensions(mm)
Rated Current In 30 A
Breaking Capacity 20KA
Max Power Dissipation 3W
Contol and Indication
Operating State/Fault Indication Indicator Light OFF/Indicator Light ON
Connection and Installation
Wire 2.5mm 2~25 mm 2
83.5
45.5
35.5
89.7
Terminal Screws M5
Torque Nm 2.5
Degree of Protection IP20
Installation Environment
Fuse Size 10x38 mm
Operating Temperature Range TU -30℃~+70℃
For Mounting On TH35-7.5/DIN35
Pollution Degree 3 5.5 44.3 18.0
Relative Humidity +20 ℃ ≤95%,+40℃≤50% 74.5
Weight 0.07kg Per pole
Installation Class Ⅲ
41 42
Memorandum
43