ZJBENY Catalouge 2018 201811191535567238

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 26

DC Electrical Components

for Photovoltaic

Leading Manufacturer Provides


ZHEJIANG BENYI ELECTRICAL Solar Power Safety
CO., LTD
Address: Wenzhou Bridge Industrial Zone,
Beibaixiang Town,Zhejiang China

TEL: +86-577-5717 7222


FAX: +86-577-5717 7007

Email: benyi@zjbeny.com
Http: // www.zjbeny.com

This catalogue has been printed on ecological paper.

Zhejiang Benyi Electrical Co., Ltd. all rights reserved.

If the models and specifications in this product catalogue is changed due to the change of products, we will not inform .
Scan it to website!

www.
zj
beny.
com
Leading Supplier for Solar Photovoltaic
Components
COMPANY
PROFILES

is one of pioneer in china in the development, production and


sales of photovoltaic (PV) DC string combiner box .We mainly
manufacturing DC isolator ,DC circuit breaker, DC fuse ,DC surge
protection device and smart monitoring device.

With more than 25 years experiences in traditional electrical area we


could provides powerful support for the renewable business.

With each product is backed by the skills and service of dedicated team
of customer-focused specialists, we have been striving to provide high-
quality products for residential, commercial and utility-scale solar
projects, we strictly make the management as per the ISO9001:2008

So far we have already obtained TUV / ROHS / CE / SAA /CB / SEMKO /


VDE / CCC / CQC certifications.

Enjoys a ready market in many countries and areas, our products


Leading Manufacturer for are widely exported to Australia, Japan, Germany, Malaysia, South
PV Solution Africa, Sri Lanka ,Indonesia, Middle East countries.

Our primary customers include Engineering Procurement Contractors


(EPCs), solar developers, Real Estate developers, Electrical
distributors and contractors, and Solar Financing companies with solar
installations .

is dedicated to make the solar power more reliable and safe.

Mission:
Making Solar PV Power System More Reliable and Safe
Value:
Honesty, Responsibility, Innovation
Faith:
People-oriented, creating value; Scientific management,
keeping developing
Quality policy:
Create the Best Products and Superb Service
Social Responsibility:
Devote us to improve the quality of life of the workforce and
BENY Electrical Production Base in Wenzhou their families as well as the local community and society at
large and to behave ethically in business and contribute to
economic development.

www.zjbeny.com
Making Superb Product ,Creating Top Brand MANUFACTURING
The Quality Management System, which includes this Policy, provides the
framework through which a formal and continuing program of review is adopted and fully
supported so that products, services and the effectiveness of systems, policies,
objectives and targets may be continually measured and improved as far as possible.
defines Quality as conformance to our Customers' needs, both internally and
externally, and as conformance to all defined quality system requirements.
Consequently, we recognise the value of our customers and the impact of our activities
upon them.

Photovoltaic DC components production workshop


Smart junction box production workshop

www.zjbeny.com
www.zjbeny.com
CONTENTS CERTIFICATE

DC Isolator Switches 01 DC Fuse Holder 40

BYH/BYT BR-30
Series DC Isolator Switches 02 PV DC Fuse Holder 41

BYT
Series DC Isolator Switches 05

BYS
Series DC Isolator Switches 12

BB1H-63
PV DC Isolator Switches 16

BH
Series PV DC Isolator Switches 19

BDH
Series PV DC Moulded Case Isolator Switch 22

DC Circuit Breakers 25

BB1-63
PV Mini Circuit Breakers 26

BB2-40
PV Mini Circuit Breakers 28

BD Series
PV DC Moulded Case Circuit Breaker 31
Safety
BD2 Series
PV DC Moulded Case Circuit Breaker 34

DC Surge Protection Device 41

BUD-40/3
PV DC Surge Protection Device 42

www.zjbeny.com
www.zjbeny.com
BYH/BYT
Series DC Isolator Switches
BYH/BYT Series
DC Isolator Switches
Application

DC Isolator Switches
BYH/BYT Series DC Isolator Switch in plastic enclosure is applied to 1-
20kw residential and commercial PV systems,is installed between solar panels and
inverter.Arcing time less than 3ms is the key of the switch and safty.Top material
and highest PV test standard ensure high quality isolator switch and long working
Welcome to our website for more information:
life.
www.zjbeny.com

BYH-32 DC Isolator Switches 1000V

Pre-wired DC Main Switch with


MC4(Optional)
IP66 , UV Resistance, Flame-
Retardant Enclosure
Arcing Time < 3ms
"OFF" Position Lockable
Earth Terminal
IEC/EN60947-3
2 Pole, 4 Poles Available(Single |
Double String)
DC-21B: 16A,25A,32A

BYH-32 BYH-32MC4

BYT-32 DC Isolator Switches 1200V

Pre-wired DC Main Switch with


MC4(Optional)
IP66 , UV Resistance, Flame-
Retardant Enclosure
Arcing Time < 3ms
"OFF" Position Lockable
Earth Terminal
IEC/EN60947-3
2 Pole, 4 Poles Available(Single |
Double String)
DC-21B: 16A,25A,32A

BYT-32 BYT-32MC4

01 02
BYH/BYT Switching Configurations

DC Isolator Switches
PV DC Isolator Switches Type 2-pole 2-pole 4-pole 4-pole with Input 4-pole with Input 4-pole with Input
4 Paralleled on top and and
Poles Output bottom Output bottom Output on top
Parameter BYH-16/BYT-16 2 2H 4 4S 4B 4T
BYH-25/BYT-25 2 2H 4 4S 4B 4T
Electrical Characteristics
BYH-32/BYT-32 2 2H 4 4S 4B 4T
Type BYH-32 BYT-32
1 3 1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7
Function Isolator, Control
Contacts
Comply with IEC60947-3 Wiring graph
Pole 4P 2 4 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8
Max Rated Current 32A
Rated Working Voltage Ue 1000V DC 1200V DC
Switching
Rated Current In 32A example
Rated Insulated Voltage Ui 1000V DC 1200V DC
Rated Impulsed Voltage Uimp 8KV
Service Life/Cycle Operation
Mechanical 20000
Dimensions(mm)
Electrical 2000
Installation Environment BYH-32/BYT-32
Ingress Protection IP66
75.0
Storage Temperature -40°C~+85°C

Wiring Diagram

188.0
170.5
Contacts wiring Poles in Number of Type Number Weight

108.5
diagram 500V 600V 800V 1000V 1200V series Strings kg/PCS

100.0
178.5

78.5
1 3
16A 16A 16A 9A 7.5A 2 1 PE2 0.70
25A 25A 20A 11A 9A 2 1 PE2 0.70
32A 32A 23A 13A 13A 2 1 PE2 0.70 M25X1.
5
2 4 47.
0

1 3 5 7 29A 29A 16A 9A 7.5A 2 1 PE2H 0.70


99.0 Ø4.3
45A 45A 20A 11A 9A 2 1 PE2H 0.70
50A 50A 23A 13A 13A 2 1 PE2H 0.70
2 4 6 8

16A 16A 16A 9A 7.5A 2 2 PE4 0.70


1 3 5 7
0.70 BYH-32MC4 / BYT-32MC4
25A 25A 20A 11A 9A 2 2 PE4
32A 32A 23A 13A 13A 2 2 PE4 0.70 75.0
2 4 6 8

16A 16A 16A 16A 16A 4 1 PE4S 0.70


1 3 5 7
25A 25A 25A 25A 25A 4 1 PE4S 0.70
32A 32A 32A 32A 32A 4 1 PE4S 0.70
2 4 6 8

* 16A 16A 16A 16A 16A 4 1 PEB 0.70


1 3 5 7

188.0
242.0
170.5

100.0
178.5

108.5
25A 25A 25A 25A 25A 4 1 PEB 0.70

78.5
32A 32A 32A 32A 32A 4 1 PEB 0.70
2 4 6 8

*1 16A 16A 16A 16A 16A 4 1 PE4T 0.70


3 5 7
47.
0
25A 25A 25A 25A 25A 4 1 PE4T 0.70
32A 32A 32A 32A 32A 4 1 PE4T 0.70
2 4 6 8

99.0 Ø4.3
*Note: Recommend for MC4 Type

03 04
BYT
BYT Series
DC Isolator Switches
Application
Series DC Isolator Switches

DC Isolator Switches
BYT series DC Isolator Switches are applied to 1-20KW Inverter,
Controller, DC Combiner Box, used for Residential or Commercial PV solar power
system(on-grid/off-grid). Arcing time less than 3ms, that make PV solar system
effectively disconnected.
Welcome to our website for more information:
www.zjbeny.com

BYT.1-32 DC Isolator Switches

BYT.1 -32 Rated Voltage 1200V DC


Single Hole Mounting Ø22mm
Flame-Retardant
Arcing Time < 3ms
IEC60947-3
4 poles(Single|Double Strings Available)
DC-21B: 16A,25A,32A up to 1200V DC

BYT.2-32 DC Isolator Switches

DIN Rail Mounting


BYT.2 -32 Rated Voltage 1200V DC
OFF LOCKABLE
Flame-Retardant
Arcing Time < 3ms
IEC60947-3
4Poles(Single|Double Strings Available)
DC-21B: 16A,25A,32A up to 1200V DC

BYT.2-32 DC Isolator Switches

DIN Rail Mounting Door Clutch


BYT.2-32 Rated Voltage 1200V DC
OFF LOCKABLE
Flame-Retardant
Arcing Time < 3ms
IEC60947-3
4 poles(Single|Double Strings Available)
DC-21B: 16A,25A,32A up to 1200V DC

05 06
BYT Switching Configurations

DC Isolator Switches
Type 2-pole 2-pole 4-pole 4-pole with Input 4-pole with Input 4-pole with Input
PV DC Isolator Switches 4 Paralleled on top and and
Poles Output bottom Output bottom Output on top
BYT.1-16/ BYT.2-16 2 2H 4 4S 4B 4T
Parameter
BYT.1-25/ BYT.2-25 2 2H 4 4S 4B 4T
Electrical Characteristics BYT.1-32/ BYT.2-32 2 2H 4 4S 4B 4T
Function Isolator, Control
1 3 1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7
Comply with IEC60947-3, DC-21B
Contacts
Pole 4P Wiring graph
Max Rated Current 32A 2 4 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8
Rated Working Voltage Ue 1200V DC
Rated Current In 16A/25A/32A
Switching
Rated Insulated Voltage Ui 1200V DC example
Rated Impulsed Voltage Uimp 8KV
Service Life/Cycle Operation
Mechanical 20000
Electrical 500
Dimensions(mm)
Installation Environment
Size of Terminal Screw M4 BYT.1
48.6
Tightening Torque Nm 2.5
2
Maximum Cable Cross Sections mm 4-16
3(MAX:5mm)
Ingress Protection IP20
Storage Temperature -25°C~+85°C

121.2

Wiring Diagram
77.9
50.9
Contacts Poles in Number of Code Weight
Configuration 600V 800V 1000V 1200V series Strings kg/PCS
1 3 16A 16A 9A 2 1 DR2 0.23 60.5
25A 20A 11A 9A 2 1 DR2 0.23 77.9
32A 23A 13A 13A 2 1 DR2 0.23
2 4

1 3 5 7 29A 16A 9A 2 1 DR2H 0.25 BYT.2-32


45A 20A 11A 9A 2 1 DR2H 0.25 DIN Rail Mounting
50A 23A 13A 13A 2 1 DR2H 0.25
2 4 6 8

1 3 5 7 16A 16A 9A 2 2 DR4 0.23


25A 20A 11A 9A 2 2 DR4 0.23
98
32A 23A 13A 13A 2 2 DR4 0.23 45.5
2 4 6 8
65.5
1 3 5 7 16A 16A 16A 16A 4 1 DR4S 0.24
25A 25A 25A 25A 4 1 DR4S 0.24
32A 32A 32A 32A 4 1 DR4S 0.24
2 4 6 8 95
61
1 3 5 7 16A 16A 16A 16A 4 1 DR4B 0.24
25A 25A 25A 25A 4 1 DR4B 0.24
32A 32A 32A 32A 4 1 DR4B 0.24
2 4 6 8 BYT.2-32
1 3 5 7 16A 16A 16A 16A 4 1 DR4T 0.24 DIN Rail Mounting
25A 25A 25A 25A 4 1 DR4T 0.24 Door Clutch
32A 32A 32A 32A 4 1 DR4T 0.24
2 4 6 8

221.5 95.4

58.4

78
60.6
95.4

07 08
PV DC Isolator Switches BYS Series
DC Isolator Switches
Application

DC Isolator Switches
S
BYS-63 DC isolator switch is applied to 1kw to 20kw PV systems.
The enclosure protection degree is IP66 for outdoor installation.

Feature
Compact structure
pre-wired DC Main Switch with MC4(optional)
UV resistant, IP66 enclosure
Arcing time < 3ms
"OFF" position Lockable
IEC60947-3 Standard
4P,6P
DC-21B
Ui:
1500V/
Uimp:
8kV

Appearance Introduction

1 Waterproof Plug 1
2 IP66 Ingress Protection 11
2
3 Sealed Plug
3
4 Type
5 Application Category 4
6 Rated Voltage 5
7 Rated Current 6
12
8 Knob 7
8
9 BE LOCKABLE
10 Electrical Diagram 9
11 Brand 10 13
12 ON
13 OFF

Parameter
BYS series isolator switch is new developed products ,which successfully Technical date Symbol Merit Unit
pass the IP66 inspection ,power frequency withstand voltage test, cycle Rated operational voltage(DC poles) Ue VDC
operation endurance etc.
Rated operational current(DC poles) Ie VDC
It successfully obtain certifications :UL ,TUV,CB,KEMA
Conventional free air thermal current Ith 63 A
Rated impulse withstand voltage Uimp 8 kV
Welcome to our website for more information:
Rated short-time withstand current(1s) Icw 8 kA
www.zjbeny.com
Rated short-circuit making capacity Icm 8 kA
Rated conditional short-circuit current 8 kA
Standard Short Circuit Rating 5 kA
High-Fault Short Circuit Rating 8 kA
Insulation voltage Ui 1500 V
Category DC DC-21B
Number of cycles of operation(With current) 3000times(6T Type is 2200 times only)
BYS-63
Number of cycles of operation(With current) 7000
Number of DC poles 4/6
Method of mounting Standard TH35-7.5 DIN rail mounting
Method of operating independent manual operation
Knob operation force max 1.4 Nm
Tightening torque terminal screws M4,-max.M4 1.2 1.8 Nm
Tightening torque panel mounting nut,min.-max. 2.5 3.0 Nm
Tightening torque M3 screw in the standard black knob,min.-max. 0.5 0.7 Nm
Ambient temperature allowed between -40to+70 ℃
Storage temperature allowed between -40to+85 ℃
Maximum relative humidity,without condensation at 20℃ 90 %
Pollution degree 2
Leading Manufacturer for IP rating terminals Ip66
PV Solution
09 10
BYS Series
Series DC Isolator Switches
BYS
PV DC Isolator Switches
Wiring Diagram
Contact DC-21B Rating Poles Number Type Weight
Configuration 600V 800V 900V 1000V 1200V 1500V in series of Strings Number kg/pcs
Welcome to our website for more information:
50A 2 1 BYS-63-2H 0.91 www.zjbeny.com

32A 23A 16A 10A 5A 2 2 BYS-63-4 0.91


30A 20A

40A 32A 16A 4 1 BYS-63-4S 0.91

40A 32A 16A 4 1 BYS-63-4B 0.91

32A 16A 4 1 BYS-63-4T 0.91

7 9 11

32A 23A 16A 10A 5A 2 3 BYS-63-6 1.05


8 10 12 30A 20A
7 9 11

63A 2 1 BYS-63-3H 1.05


8 10 12

7 9 11

32A 6 1 BYS-63-6S 1.05


8 10 12

7 9 11

32A 6 1 BYS-63-6B 1.05


8 10 12

7 9 11

40A 3 2 BYS-63-6T 1.05


8 10 12

Switching Configurations
2-pole 2-pole 2-pole 2-pole 2-pole 4-pole
2-pole 2-pole
with Input with Input with Input with Input with Input with Input
Type 4Parlleled 4-pole 6-pole 6Parlleled
on top and and on top and and
poles poles
Output bottom Output bottom Output on top Output bottom Output bottom Output bottom

Part Number 2H 4 4S 4B 4T 6 3H 6S 6B 6T

1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11
Contacts
Wiring
diagram
2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 10 12 2 4 6 8 10 12 2 4 6 8 10 12 2 4 6 8 10 12 2 4 6 8 10 12

Switching
example

Dimensions(mm)
194.0
17.8
9.0

190.5
128.0

149
100.5

87.0

99.5

47.0 M25.0X1.5 M12/20/25 M12/20/25


100.0 100.0

4 Poles 6 Poles

11 12
BYS Series
DC Isolator Switches
Application Wiring Diagram

DC Isolator Switches
BYS series DC isolator switch for PV system.Rated current is 5A to 63A, Contact DC-21B Rating UL Ratings UL508i Number Weight
S
Poles Type
Rated working voltage is 600V to 1500V. oudle design can match with many wire Configuration in series of Strings Number kg/pcs
600V 800V 900V 1000V 1200V 1500V 500V 600V 1000V
ways.Mounting:Standard Din Rail/Panel mounting/Fix installtion.

Appearance Introduction

1 Brand
2 Type 32A
3 OFF 30A 20A
8
Application Category 1
4
5 Insulation voltage 2 9
6 Rated impulse withstand voltage
10
7 Rated Current 3
8 ON 4
5 11
9 Certificate Symbol
6
10 Knob
7
11 Standard Code

Type Instruction 30A 20A

BYS .1/.2 - 63 - 2H

Basic Max Rated Polarity


Designation Accessories
Current Configuration

.1:Panel 2
mounting 4/2H/4S/4T/4B
63A
.2:DIN rail 6/3H/6S/6T/6B
mounting 8

Parameter
Technical data Symbol Merit Unit
Rated operational voltage (DC poles) Ue
Rated operational current (DC poles) Ie
Conventional free air thermal current Ith 63 A 30A 20A
Rated impulse withstand voltage Uimp 8 kV
time withstand current (
Rated short- 1s) Icw 8 kA
Rated short-
circuit making capacity Icm 8 kA
Rated conditional short-circuit current 8 kA
Standard Short Circuit Rating 5 kA
High-Fault Short Circuit Rating 8 kA
Insulation voltage Ui 1500 V
Installation Environment
Utiizatin category DC DC-21B
Number of cycles of operation(With current) 3000 times (6T Type is 2200 times only)
Number of cycles of operation(Without current) 7000 times
Number of DC poles 1/2 / 3 / 4 / 6 / 8
Method of mountig Panel mounting Standard TH35-7.
5 DIN rail mounting
Method of operatin independent manual operation
Knob operation force max. 1.4 Nm
Tightening torque terminal screws M4 , min. - max.M4 1.2 1.8 Nm
Tightening torque panel mountig nut, min. - max. 2.5 3.0 Nm
Tightening torque M3 screw in the standard black knob, min. - max. 0.5 0.7 Nm
Ambient temperature allowed between -40 °C ~ +70°C °C
Storage temperature allowed between -40°C ~ +85°C °C
Maximum relative humidity, without condensation at 20°C 90 %
Pollution degree 2
IP rating terminals IP20
IP rating gland of the shaft in case of single hole panel mounting IP66

13 14
BB1H-63
PV DC Isolator Switches

Welcome to our website for more information:


www.zjbeny.com

Bus-barwire A and Bus-barwire A for series and parallel switching of contacts

Dimensions(mm)

BYS.1 45.0 BYS.2


8.5

N is the number of layers in the switch

37.5
M16.0X1.5

45.0
N is the number of layers in the switch
M16.0X1.5

19.5

16.0
60.0

Gasket 1.5
32.5+(Nx10.5)±1%

60.0

68.0

78.0

32+(Nx10.5)±1%

11.8
2.0

11.8
47.0
47.0
16±0.2
0

16±0.2
0

12±00.2 12±00.2

PANEL
PANEL
CUTOUT
CUTOUT

15 16
BB1H-63
PV DC Isolator Switches
Application Wiring Method

DC Isolator Switches
BB1 Series PV DC Isolator switches are mainly be used in PV solar power
Pole 1P 2P 3P 4P
system, which are applied for DC solar combiner box, controller etc. The Max
voltage up to 1200V DC, current up to 63A ,with the function of effective
disconnection and Anti-reflux protection. Scientific design of arc-extinguishing
S system keep PV system more safe.
Type
Appearance Introduction

1 Brand
2 Type
3 Rated Current
1 1 3 1 3 1 3 5 1 3 5 1 3 5 7
Rated Voltage -/+ 1 3 5 7
4 1 + -
Load Load -/+ Load

5 Standard Code 2 Contacts


6 Certificate Symbol Wiring graph
7 Indicator 3 Load
Load +/- Load +/- Load -/+ +/- -/+
+/- +/- -/+ -/+ +/-
2
8 Wiring Diagram 7 2 4 2 4 2 4 6 2 4 6 2 4 6 8 2 4 6 8
4
5 8
6
Dimensions(mm)

35.5
Type Instruction
17.8 53 71

Nonpolarity
BB1 H - 63 4P 25 1200V
Functions: Unfrequent operation and
Isolation
Rated Current: Up to 63A
Product Max Rated Rated Rated

81.2

111
Rated Voltage: 1200V DC Pole
Code Current Current Voltage

96.5

96.5
Flash Barrier Keep System More Safe
Comply with :IEC60947-3/GB14048-3
PV DC 1P 300V
25A
2P 600V
Isolator 63A 40A
3P 900V
Switches 63A
4P 1200V

45
Parameter
Electrical Characteristics
Type BB1H-63
Comply With IEC60947-3/GB14048.3

74
Pole 1P 2P 3P 4P

52
Rated Working Voltage Ue 300V DC 600V DC 900V DC 1200V DC

50
Max Rated Current 63A
Rated Current In 25A,40A,63A
Rated Insulated Voltage Ui 1200V DC 36.2

Rated Impulsed Voltage Uimp 6KV


Service Life/cycle Operation
Actual Value 20000
Mechanical
Standard Value 8500
Actual Value 4000
Electrical
Standard Value 1500
Isolator Function Yes
Installation Environment
204.0 196.0
Ingress Protection All Sides IP40 ,Connection Terminal IP20 110.0
2
Terminal Cross Section 2.5-25mm
Working Temperature -25℃~+70℃
Storage Temperature -40℃~+85℃
Resistance to Humidity And Heat Ⅱ(when humidity arrived to 55℃,
relative humidity95%) 99.5
Resistance to Shock 2.6 IEC60068
Resistance to Impack 2.27 IEC60068

17 18
BH
BH Series
PV DC Isolator Switches
Application
Series PV DC Isolator Switches

DC Isolator Switches
BH series PV DC Isolator Switches are mainly used in large solar power
system, such like solar DC combiner box ,inverter and DC power distribution
cabinet. Rated voltage up to 1000V DC, Rated Current up to 250 A with the function
of effective disconnection.

Welcome to our website for more information:


www.zjbeny.com Appearance Introduction
Breaking Power Optimized Across
The Entire Current Range. 1 Brand
Visible Contacts 2 Knob
1
Simplicity in Installation
Padlockable in The "OFF" Position
and with Door Interlock in The "ON" 2
Position
Ajustable Shaft for a Depth of
Installation Ranges
DC21B:160A,200A,250A with
Operational Voltage of 1000V DC

Type Instruction

BH - 1000V 250 2P

Product Rated Max Rated


Pole
Code Voltage Current

PV DC 600V 2P
250
Isolator Switch 1000V 4P

Parameter
Bh Series Pv Dc Isolator Switches
Pole 2P 4P
Electrical Characteristics
Rated Working Voltage Ue 600V DC 1000V DC
Max Rated Current 250A 250A
Rated Current In 160A 200A 250A 160A 200A 250A
Rated Insulated Voltage Ui 600V DC 1000V DC
Rated Impulsed Voltage Uimp 8KV 12KV
Rated Short-time Withstand Current 1s 8KA 8KA
Rated Thermal Current Free Air 200A 200A 250A 200A 200A 250A
2P (Ambient Temperature:40℃)Enclosed Air 160A 200A 250A 160A 200A 250A
Service Life/cycle Operation
Mechanical 10000 10000
Weight(without Accessory) kg 0.8 1.5

Terminal Screw Specification mm M8X25 M8X25

Terminal Torque Force NM 15-22 15-22


Ingress Protection IP20 IP20
Installation Environment
Comply with IEC60947-3
Operating Temperature -45℃~+70℃
4P

19 20
BH
BDH
BDH Series PV DC Moulded Case Isolator Switch
Series PV DC Isolator Switches
Wiring Method
Contacts wiring graph Pole Rated insulation voltage Ui Max Rated Current A Welcome to our website for more information:
www.zjbeny.com

4P DC 1000V 250A

2+2P DC 600V 250A

2P DC 600V 250A

Dimensions(mm)

110.5
20 180.5
68 20 35 68

25
34.5 34.5
Ø26.5 Ø26.5
6 6
100 100
60 63

35 3 35.5 89~175 35 3 35.5 89~175


105 175
2P 4P

Installation

Ø5...6mm

2,5mm 0,1 in
0.8 Nm 7Ib.in

M5
3/16
TORX T15 1.5NM/13.2in-Ibs
0.8Nm
360° 7 Ib.in

360°

21 22
BDH Series
PV DC Moulded Case
Isolator Switch Application
Type BDH-125 BDH-250 BDH-400 BDH-630

DC Isolator Switches
BDH series PV DC Moulded Case Isolator Switches are mainly used in
S large solar power system, such like solar DC combiner box ,inverter and DC power
distribution cabinet. Rated voltage up to 1200V DC, Rated Current up to 630A with
the function of effective isolator.
Picture

Appearance Introduction

1 Brand
2 Type
3 Rated Current
1
4 Rated Voltage
2
5 Rated Short-time Withstand Current Wiring Method
3 7
6 Standard Code 4 8
Type Y MCCB Type S MCCB
7 Certificate Symbol 5
8 Wiring Diagram 6

Contacts
Wiring graph

Type Instruction

High Insulation Performance


Functions: Unfrequent Operation and BDH - 630 4P 1200V
Isolation
Rated Voltage up to 1200V Dimensions(mm)
Product Max Rated Rated
Rated Current 125A,250A,400A,630A Pole
Code Current Voltage
IEC60947-3, GB14048-3
PV DC
125A, 250A
Moulded Case 4P 1200V
400A, 630A
Isolator Switch

114
92
85

110
89
Parameter

79
BDH series PV DC Moulded Case Isolator Switch 150.5
Type BDH-125 BDH-250 BDH-400 BDH-630 30
122 165 35 140
Pole 4P
Max Rated Current 125A 250A 400A 630A
Electrical Characteristics
Rated Working Voltage Ue 1200V DC
60/80 125/160 250/300/315
Rated Current In(A) 400/500/630
100/125 200/250 350/400 50
282
70
Rated Insulated Voltage Ui 1200V DC
Rated Impulsed Voltage Uimp 8KV
1 Min Power Frequency Withstand Voltage 3.8KV
Control And Indication
Direct (RHD) Optional
Control Manual Extended(ERH) Optional
Mode

153
Optional

160
MOD

107

115
105
Shunt Release (SHT) Optional

98
Auxiliary Release Optional
Terminal End Cover Yes
258
Interphase Barriers Yes 282
Service Life/Cycle Operation 198

Mechanical 14000 14000 5000 5000


Electrical 5000 5000 1500 1500
Size (L x W x H) 150x122x92 165x140x89 258x198x107 282x282x115
Ingress Protection All Sides IP40 ,Connection Terminal IP20
Installation Environment
Comply with IEC60947-3/GB14048.3
Storage Temperature -45°C~+70°C

23 24
BB1-63
BB1-63
PV Mini Circuit Breakers
Application
PV Mini Circuit Breakers S

BB1 Series PV Mini Circuit Breakers are mainly applied to DC solar


combiner box ,Controller etc. The main function include overload protection ,Anti-
reflux protection and short-circuit protection. Scientific design of arc-extinguishing
system keep solar system more safe. Max Voltage up to 1200V DC, current up to 63A.
Welcome to our website for more information:
www.zjbeny.com Appearance Introduction
1 Brand
2 Type
3 Rated Current

DC Circuit Breakers
4 Rated Voltage
1
5 Ultimate Breaking Capacity
2
6 Certificate Symbol
3
7 Standard Code
8 Indicator 4 8

9 Wiring Diagram 5 9
6
7

Type Instruction

Nonpolarity BB1 - 63 4P 25 1200V


High Short-Circuit / Breaking Capacity
Functions: Overload, Short Circuit,
Unfrequent Operation and, Anti-reflux Product Max Rated Rated Rated
Pole
Code Current Current Voltage
Protection
Rated Voltage: 1200V, Ultimate
1P 3A,4A,6A 300V
Breaking Capacity : 6KA PV Mini
2P 10A,13A,16A 600V
Circuit 63A 20A,25A,32A
Rated Current: 63A 3P 900V
Breakers 4P 40A,50A,63A 1200V
Comply with : IEC60947-2/GB14048-2

Parameter
Electrical Characteristics
Type BB1-63
Comply with IEC60947-2/GB14048.2
Pole 1P 2P 3P 4P
Rated Working Voltage Ue 300V DC 600V DC 900V DC 1200V DC
Max Rated Current 63A
Rated Current In 3A, 4A, 6A,10A,13A,16A,20A,25A,32A,40A,50A,63A
Rated Insulated Voltage Ui 1200V DC
Rated Impulsed Voltage Uimp 6KV
Ultimate Breaking Capacity Icu 6KA
Run Breaking Capacity Ics 100%
Tripping Type Thermal Magnetic Type
Service Life/cycle Operation
Actual Value 20000
Mechanical
Standard Value 8500
Actual Value 4000
Electrical
Standard Value 1500
Installation Environment
Ingress Protection All Sides IP40 ,Connection Terminal IP20
Terminal Cross Section 2.5-25mm 2
Working Temperature -25℃~+70℃
Storage Temperature -40℃~+85℃
Resistance to Humidity And Heat Ⅱ(when Humidity arrived to 55℃,
Relative Humidity95%)
Resistance to Shock 2.6 IEC60068
Resistance to Impack 2.27 IEC60068

25 26
BB1-63
BB2-40
PV Mini Circuit Breakers
PV Mini Circuit Breakers
Wiring Method
Pole 1P 2P 3P 4P Welcome to our website for more information:
www.zjbeny.com

Type

1 1 3 1 3 1 3 5 1 3 5 1 3 5 7
-/+ 1 3 5 7
+ - -/+ Load
Load Load

Contacts
Wiring graph
Load Load
+/- Load +/- -/+ +/- -/+ +/-
Load +/- -/+ +/- -/+
2 2 4 6 8 2 4 6 8
2 4 2 4 2 4 6 2 4 6

Characteristic Curve Dimensions(mm)

B curve : (
4.4-6.6)In
t(s)
10 000
5 000
2 000
1 000
500
200
100
50
20
10
5
2 204.0 196.0
1 110.0
.5
.2
.1
.05
.02
.01 99.5
.005
.002
.001
.5 .7 1 2 3 4 5 7 10 20 30 50 70 100 200 300 I/ln

Dimensions(mm)

35.5

45
17.8 53 71
74
81.2

111

52
50
96.5

96.5

36.2

27 28
BB2-40
PV Mini Circuit Breakers
Application Characteristic Curve
S

BB2-40 Series PV Mini Circuit Breakers are mainly applied to DC solar B curve : (
4.4-6.6)In
combiner box ,Controller etc. The main function include overload protection ,Anti- t(s)
reflux protection and short-circuit protection. Scientific design of arc-extinguishing 10 000
5 000
system keep solar system more safe. Max Voltage up to 1500V DC, current up to 40A. 2 000
1 000
500
Appearance Introduction 200
100
50
1 Brand 20
10
2 Type 5

DC Circuit Breakers
3 Rated Current 2
1
4 Rated Voltage 1 .5
.2
5 Standard Code 2
.1
6 Ultimate Breaking Capacity .05

3 .02
7 Indicator .01
7 .005
8 Wiring Diagram 4
8 .002
5 .001
.5 .7 1 2 3 4 5 7 10 20 30 50 70 100 200 300 I/ln
6

Type Instruction Wiring Method

Nonpolarity BB2 - 40 4P 25 1200V Pole 1P 2P 3P 4P

High Short-Circuit / Breaking Capacity


Functions: Overload, Short Circuit,
Product Max Rated Rated Rated
Unfrequent Operation and, Anti-reflux Pole
Code Current Current Voltage
Protection Type

Rated Voltage: 1200V, Ultimate


Breaking Capacity : 6KA 1P 3A,4A,6A 500V
PV Mini
2P 10A,13A,16A 1000V
Rated Current: 40A Circuit 40A 3P 20A,25A, 1200V
Breakers 4P 32A ,40A, 1500V
Comply with : IEC60947-2/GB14048-2
1 1 3 1 3 1 3 5 1 3 5 1 3 5 7
-/+ 1 3 5 7
+ - -/+ Load
Load Load

Contacts
Parameter Wiring graph
Electrical Characteristics Load Load
+/- Load +/- -/+ +/- -/+ +/-
Load +/- -/+ +/- -/+
BB2-40 2
Type 2 4 2 4 2 4 6 2 4 6 2 4 6 8 2 4 6 8

Comply with IEC60947-2/GB14048.2


Pole 1P 2P 3P
Rated Working Voltage Ue 600V DC 1000V DC 1500V DC
Max Rated Current 40A
Rated Current In 2A,4A,6A,10A,13A,16A,20A,25A,32A,40A
Rated Insulated Voltage Ui 1500V DC
Rated Impulsed Voltage Uimp 8KV Dimensions(mm)
Ultimate Breaking Capacity Icu 3KA
Run Breaking Capacity Ics 100%
Tripping Type Thermal Magnetic Type 35.5
Service Life/cycle Operation 45
17.8 53 71
Actual Value 20000
Mechanical
Standard Value 8500
Actual Value 4000
Electrical
Standard Value 1500

74
Installation Environment
81.2

111
Ingress Protection All Sides IP40 ,Connection Terminal IP20

52
50
96.5

96.5
Terminal Cross Section 2.5-25mm 2
Working Temperature -25℃~+70℃
Storage Temperature -40℃~+85℃ 36.2

Resistance to Humidity And Heat Ⅱ(when Humidity arrived to 55℃,


Relative Humidity95%)
Resistance to Shock 2.6 IEC60068
Resistance to Impack 2.27 IEC60068

29 30
BD
BD Series
PV DC Moulded Case
Circuit Breaker Application
Series PV DC Moulded Case Circuit Breaker
BD series PV DC Moulded Case Circuit Breaker (MCCB) are mainly used
S
in large solar power system, which are applied for solar DC combiner box ,inverter
and DC power distribution cabinet. Rated voltage up to 1000V DC, current up to
630A , with the function of overload protection and short-circuit protection.

Welcome to our website for more information:


www.zjbeny.com Appearance Introduction

1 Brand

DC Circuit Breakers
2 Type
3 Rated Current
1
4 Rated Voltage
2
5 Breaking Capacity 8
3
6 Operation Breaking Capacity 4 9
7 Standard Code 5 10
8 Certificate Symbol 6
9 Wiring Diagram 7
10 Characteristic Curve

Type Instruction

High Short-Circuit/Breaking Capacity


Protection Functions: Overload, Short BD - 630 4P 1000V
circuit , Unfrequent Operation
Rated Voltage up to 1000V DC
Product Max Rated Rated
Rated Current 125A,250A,400A,630A Pole
Code Current Voltage
IEC60947-2, GB14048-2
Easy Installation PV DC
125A, 250A
Moulded Case 4P 1000V
400A, 630A
Circuit Breaker

Parameter
BD series PV DC MCCB
Type BD-125 BD-250 BD-400 BD-630
Pole 4P 4P 4P 4P
Max Rated Current 125A 250A 400A 630A
Electrical Characteristics
Rated Working Voltage Ue 1000V DC 1000V DC 1000V DC 1000V DC
63/80 125/160 250/300/315
Rated Current In(A) 400/500/630
100/125 200/250 350/400
Rated Insulated Voltage Ui 1000V DC
Rated Impulsed Voltage Uimp 8KV
1 Min Power Frequency Withstand Voltage 3.8 KV 3.8 KV 3.8 KV 3.8 KV
Ultimate Breaking Capacity Icu 20 KA 20 KA 20 KA 20 KA
Run Breaking Capacity Ics 15 KA 15 KA 15 KA 15 KA
Protection
Tripping Type Thermal Magnetic Type
Control And Indication
Direct (RHD) Optional
Control Manual Extended(ERH) Optional
Mode
MOD Optional
Shunt Release (SHT) Optional
Auxiliary Release Optional
Terminal End Cover Yes
Interphase Barriers Yes
Service Life/Cycle Operation
Mechanical 14000 14000 5000 5000
Electrical 5000 5000 1500 1500
Size (L x W x H) 150x122x92 165x140x89 258x198x107 282x282x115
Ingress Protection All Sides IP40 ,Connection Terminal IP20
Installation Environment
Comply With IEC60947-2/GB14048.2
Storage Temperature -45°C~+70°C

31 32
BD Series
BD2
Series PV DC Moulded Case Circuit Breaker
PV DC Moulded Case Circuit Breaker
Characteristic Curve
S 10000
7200
3600 Welcome to our website for more information:
2000 www.zjbeny.com
1000
500
最大Max.
200
100
50
20
10
5
2
1
.5
.2 最小Min.
.1
.05
.02
.01
.005
.002
.001
.5.7 1 2 3 4 5 7 10 15 20 30 40 I/IR

Type BD-125 BD-250 BD-400 BD-630

Picture

Type Type Y MCCB Type S MCCB

Contacts
Wiring graph

Dimensions(mm)

35
30
114

132.5

126
92
85

110
89
79

150

122 165 35 140

44 50 282
70
194
153

160
107

98

115
105

258
198 282

33 34
BD2 Series
PV DC Moulded Case
Circuit Breaker Application Characteristic Curve
S 10000
S
BD2 series PV DC Moulded Case Circuit Breaker (MCCB) are mainly 7200
3600
used in large solar power system, which are applied for solar DC combiner box 2000
1000
,inverter and DC power distribution cabinet. Rated voltage up to 1500V DC, current 500
最大Max.
up to 400A , with the function of overload protection and short-circuit protection. 200
100
50
20
Appearance Introduction 10
5
2
1
1 Brand .5
2 Type .2 最小Min.
.1
3 Rated Current .
05
1
4 Rated Voltage .02
2 .01
5 Breaking Capacity 3 8 .005
.002
6 Operation Breaking Capacity 4 9 .001

7 5 10 .5.7 1 2 3 4 5 7 10 15 20 30 40 I/IR
Standard Code
8 Certificate Symbol 6
7 Type BD2-225T BD2-225S BD2-400
9 Wiring Diagram
10 Characteristic Curve

Type Instruction Picture

High Short-Circuit/Breaking Capacity


BD2 - 400 3P 1000V
Protection Functions: Overload, Short
1 3 1 3
circuit , Unfrequent Operation
Rated Voltage up to 1000V DC Rated
Product Max Rated
Pole Contacts
Rated Current 225A, 400A Code Current Voltage
Wiring graph
IEC60947-2, GB14048-2
+ + + -
Easy Installation PV DC 2 4 2 4
225A 2P
Moulded Case 1500V
400A 3P
Circuit Breaker

Dimensions(mm)
Parameter BD2-225T BD2-225S
BD2 series PV DC MCCB 120 92
136 121
95
Type BD2-225T BD2-225S BD2-400 44 95
87 87
Pole 2P 3P 3P
Max Rated Current 225A 225A 400A
Electrical Characteristics
Rated Working Voltage Ue 1000V DC 1500V DC 1500V DC
In(A) 80A/100A/125A/ 80A/100A/125A/ 250A/300A/
Rated Current 160A/200A/225A 160A/200A/225A 350A/400A
180 159 180 159
Rated Insulated Voltage Ui 1000V DC 1500V DC 1500V DC
Rated Impulsed Voltage Uimp 8KV
1 Min Power Frequency Withstand Voltage 3.8 KV
Ultimate Breaking Capacity Icu 20 KA
Run Breaking Capacity Ics 15 KA
Instantaneous action 8In
Protection
Tripping Type Thermal Magnetic Type BD2-400
Control And Indication
Direct (RHD) Optional 204 165
Control Manual Extended(ERH) Optional 70
119
Mode 106
MOD Optional
Shunt Release (SHT) Optional
Auxiliary Release Optional
Terminal End Cover Yes
Interphase Barriers Yes
Service Life/Cycle Operation
Mechanical 8500 8500 4000 258 194
Electrical 1500 1500 1000
Size (L x W x H) 180x92x87 180x135x87 258x204x119
Ingress Protection All Sides IP40 ,Connection Terminal IP20
Installation Environment
Comply With IEC60947-2/GB14048.2
Storage Temperature -45°C~+70°C

35 36
BUD-40/3
BUD-40/3
PV DC Surge
Protection Device
Application
PV DC Surge Protection Device DC Surge Arrester BUD-40/3 is a Type 2 DC Surge Protection Device for
DC side to protect the terminal devices in PV system from over voltage, like solar
panels or inverters. Available for 600Vdc ,1000Vdc,1500Vdc.
*The only RoHS compliant DC SPD in China
*EN 50539-11 PV standard
Welcome to our website for more information:
www.zjbeny.com Appearance Introduction

1 Brand
2 Type
3 Max. Discharge Current I max
1 7
4 Nominal Discharge Current I n
2
5 Voltage Protection Level U p
3
6 Max. Continuous Operating Voltage U cpv 4
7 Indicator 5 8
8 Standard Code 6 9
9 Certificate Symbol

DC Surge Protection Device


Type Instruction

BUD - 40 / 3 1000V RC

Product Max. discharge Rated With


Pole Voltage Remote
code current signalling contact

PV DC Surge RC: With Remote


Protection 40KA 3P 1000V signalling contact
Device Non: Without contact

Parameter
PV DC Surge Protection Device
Modules 3 modules
Suitable For Use in All Photovoltaic Standard EN 50539-11 Type 2
Systems Electrical Characteristics
Prewired Modular Complete Unit, Open Voltage Uoc Max 1000V
Consisting of A Base Part and Plug-in Max Continuous Operational Voltage Uc 1000V
Protection Modules Nominal Discharge Current In(8/20)µs 20KA
Plug-in Protection Module, Easily Maximum Discharge Current Imax(8/20)µs 40KA
Installation and Maintainance Voltage Protection Level Up Up ≤3.8KV
High Energy Varistor, Response Time Response Time tA ≤25ns
Indication
Less Than 25 Nanosecond
Operating State/fault Indication Green/Red
Optional Remote Signalling
Plug-in Protection Module YES
Contact(FM) for Monitoring Device
Type of remote signalling contact changeover contact
(Floating Changeover Contact)
Remote Signalling Max Working Voltage 30V DC
Din Rail Mounting TH35-7.5/DIN35
Remote Signalling Max Working Current 1A
Comply with :EN 50539-11 Connection And Installation
Cross-sectional area min. 1.5 mm 2 solid / flexible
Cross-sectional area max. 35 mm 2 stranded / 25 mm 2 flexible
Connection mm 2 By screw terminal 4-25 mm 2
Main Circuit 2.5
Torque(Nm)
Remote Contact 0.25
For mounting on 35 mm DIN rails
Place of installation indoor installation
Degree of Protection IP20
Installation Environment
Operating Temperature Range TU -40℃~+80℃
Relative Humidity 30%~90%
Weight kg 0.36

37 38
BR-30
BUD-40/3
PV DC Surge
Protection Device
Principal Drawing
PV DC Fuse Holder
BU-40/3 Switch-station BU-40/3 Converter
F
L+ AC
Generator

F
L- DC Welcome to our website for more information:
www.zjbeny.com

Wiring Method

Dimensions(mm)
46.5

84
89
35

5.5 44
53.5
69.5

39 40
BR-30
PV DC Fuse Holder
Application
BR-30
S

PV DC BR-30 Fuse Holder was designed and manufactured , complying PV DC Fuse Holder
with the standard IEC60947-3. The Rated Current up to 30A,rated voltage up to
1000V DC. It applied for PV DC combiner box, inverter etc, with the main function of
over-current protection and effective disconnection. Installation

Appearance Introduction
1 Brand
2 Type
3 Rated Current
4 Rated Voltage
5 Fuse Size 1 咔嗒!
下拉
6 Electrical Diagram 2
7 Status Indicator 3 6
4 咔嗒!
5
7 插入

Replacement Fuse

Type Instruction

Photovoltaic Applications
BR - 30 1000V
Max Breaking Capacity up to
20KA,Effective Protection
The Innovation Replacing Fuse Link
Product Max Rated Rated
Touch-safe Code Current Voltage

DC Fuse Holder
Led Indicator, Reminding Fuse Link
Replacement
PV DC
Be Suit for 10x38mm Fuse Size 30A 1000V
Fuse Holder
Comply with :IEC6094-3

Parameter
PV DC BR-30 Fuse Holder
Pole 1P
According to IEC 60947-3
Electrical Characteristics
Rated Working Voltage Ue 1000V DC
Dimensions(mm)
Rated Current In 30 A
Breaking Capacity 20KA
Max Power Dissipation 3W
Contol and Indication
Operating State/Fault Indication Indicator Light OFF/Indicator Light ON
Connection and Installation
Wire 2.5mm 2~25 mm 2

83.5
45.5
35.5
89.7
Terminal Screws M5
Torque Nm 2.5
Degree of Protection IP20
Installation Environment
Fuse Size 10x38 mm
Operating Temperature Range TU -30℃~+70℃
For Mounting On TH35-7.5/DIN35
Pollution Degree 3 5.5 44.3 18.0
Relative Humidity +20 ℃ ≤95%,+40℃≤50% 74.5
Weight 0.07kg Per pole
Installation Class Ⅲ

41 42
Memorandum

43

You might also like