5F., NO.105, Jhongcheng Rd., Tucheng Dist.

,
MEASURE WITH PRECISION New Taipei City 23674, Taiwan (R.O.C.)
TEL: 886-2-22681528
www.sew.com.tw FAX: 886-2-22681529
e-mail: sales@sew.com.tw

Digital Multimeter
DC Current :
Ranges Resolution Accuracy Input protection
300.0μA 0.1μA
3000μA 1μA
±(1%rdg+5dgt) 500mA
30.00mA 0.01mA
300.0mA 0.1mA
10A 10mA ±(2%rdg+3dgt) 12.5A
●Overload Protection 0.5A/250V fast blow fuse for 300mA
12.5A/500V fast blow fuse for 10A
AC Current :
Ranges Resolution Accuracy Input protection
300.0μA 0.1μA
3000μA 1μA
30.00mA 0.01mA
±(1%rdg+5dgt) 500mA
300.0mA 0.1mA
10A 10mA ±(2%rdg+3dgt) 12.5A
●Overload Protection 0.5A/250V fast blow fuse for 300mA
12.5A/500V fast blow fuse for 10A
Resistance:
Max Max open
Ranges Resolution Accuracy test circuit
current voltage
6410 DM 300.0Ω
3000Ω
0.1Ω
1Ω
FEATURES
30.00kΩ 10Ω ±(1.5%rdg+3dgt)
●●3000 counts with a maximum display of 2999. 300.0kΩ 100Ω 0.51mA 0.39V
●●Angled display design helps the user to identify the 3.000MΩ 1kΩ
reading of value easier. 30.00MΩ 10kΩ ±(2%rdg+4dgt)
●●Auto scanning function for AC/DC voltage, and cur- ●Overload Protection 500V DC
rent. Frequence:
●●Auto ranging. Ranges Resolution Accuracy
●●Range change function. 3.000kHz 1Hz
●●Continuity check. 30.00kHz 10Hz ±(1.0%rdg+2dgt)
●●Diode & Capacitance measurement. 100.0kHz 100Hz
●●Data hold function.
Continuity:
●●Low battery indication.
●●Over range indication. Ranges Resolution Continuity beeper Test current
300Ω 0.1Ω < 30Ω 0.51mA
●●Fuse protection.
●●Special hook design used to hang the meter for ease Capacitance:
of use. Ranges Resolution Accuracy
SPECIFICATIONS 3000pF 1pF
30nF 10nF
DC Voltage : 300nF 100nF
Ranges Resolution Accuracy Input protection 3μF 1nF
±(3%rdg+10dgt)
300.0mV 100μV 30μF 10nF
3.000V 1mV 300μF 100nF
30.00V 10mV ±(0.5%rdg+3dgt) 1000V DC 3mF 1µF
300.0V 100mV 30mF 10µF
1000V 1V GENERAL
●Input impedance : 10MΩ Low battery indication “BATT”
AC Voltage : Operating temperature 0ºC ~ 40ºC, 80% Max.
Storage temperature
Ranges Resolution Accuracy Input protection -10ºC ~ 50ºC, 80% Max.
& humidity
300.0mV 100μV Dimensions 192(L) × 88.5(W) × 45(D)mm
3.000V 1mV Weight
Approx. 345g
30.00V 10mV ±(1%rdg+5dgt) 800V AC (battery included)
300.0V 100mV Power source 1.5V (AAA) × 2
750V 1V EN 61010-1 CAT III 600V
Safety standard
●Input impedance : 10MΩ EN 61326-1
Instruction manual Test leads
Accessories
Batteries Holster (optional)