Professional Documents
Culture Documents
Dgtl-Brkopt-2007
Dgtl-Brkopt-2007
#CiscoLive
Agenda
• Introduction – meet Optical/IP Engineers
• DWDM Technology Overview
• Optical Fiber – its properties and effects
• DWDM Components
• Increasing Capacity, Flexibility and
Distances
• Why Build Private Fiber Optic Networks?
• Building a DWDM Network – Example
• Tools for Optical Engineers
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 3
Traditional IP Engineer’s view of Optical
Networking
• Grey optics connect buildings/floors
together, a mystery beyond
• Layer 1 demands a different skillset
from Ethernet
• Fiber optic technology has a steep
learning curve
• Traditional Engineers understand IP,
not Transport, hard to find both
skillsets
• Fiber optic networks are costly
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 4
What is DWDM
What is WDM – Wavelength Division Multiplexing
• Optical (light) signals of different wavelengths do not interfere with
each other on a fiber
• Each wavelength represents an independent optical channel
Channel 1
Channel 2
Channel 3
• Protocol Agnostic
• Any-Rate Ethernet, TDM, Fiber
Channel, etc.
• Bit-Rate Agnostic
• Each Wavelength can be different
bit-rates
• Allows Infrastructure Evolution to
meet your needs – i.e. Future
Rates
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 7
Attenuation Profile of Fiber
1st Window That Way (850 nm)
0.6
5th Window
3rd Window
2nd Window
4th Window
Attenuation (dB/km)
0.5
0.4
0.3
0.2
0.1
1200 1300 1400 1500 1600 1700
Wavelength (nm) C-Band
L-Band
S-Band
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 8
xWDM Channel Overview
WDM CWDM DWDM
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 9
ITU-T Grid
ITU wavelengths = lambdas = channels centered around 1550 nm (193 THz)
0.4 nm spacing
Wavelength
(nm)
1528.77 nm 1552.52 nm 1578.23 nm
(Center channel)
50 GHz spacing
Frequency
(THz)
196.2 THz 193.1 THz 190.1 THz
(Center channel)
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 10
Optical Fiber
Applications for Different Fiber Types
Fiber Type Application Notes
SMF (G.652) • Good for Single-Channel at 1310 nm
NDSF • OK for Single-Channel at 1550
• OK for DWDM (With Dispersion Mgmt.)
DSF (G.653) • OK for Single-Channel at 1310 nm
• Good for Single-Channel at 1550 nm
• Bad for DWDM (C-Band) (causes non-linear effects)
NZDSF +/- (G.655) • OK for Single-Channel at 1310 nm
• Good for Single-Channel at 1550 nm
• Good for DWDM (C + L Bands)
Extended Band (G.652.C) reduced • Good for Single-Channel at 1310 nm
water peak • OK for Single-Channel at 1550 nm
• OK for DWDM (With Dispersion Mgmt.)
• Good for CWDM (>8 wavelengths)
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 12
Transmission Impairments
Loss (dB/km)
2.0
L-band:1565–1625nm
C-band:1530–1565nm
S-band:1460–1530nm
• Attenuation
0.5
2.5Gb/s Fiber
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 13
Attenuation: Optical Budget
Basic Optical Budget = Tx Output Power – Rx Input Sensitivity
Pout = +2 dBm R = -18 dBm
Max Budget = 20 dB
Optical Budget is affected by:
• Fiber attenuation
• Splices
• Patch Panels/Connectors
• Optical components (filters, amplifiers, etc.)
• Micro and Macro Bends in fiber
• Contamination (dirt/oil on connectors)
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 14
Laser Output Power and
Receiver Sensitivity and dBm
• Fiber loss expressed in dB but transmitter/receiver power is expressed in
dBm
• This is why both the transmitter output power and the receiver sensitivity is
expressed in dBm:
PowerdBm=10log(PmW/1mW)
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 16
Solution: Dispersion Compensating Unit
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 18
Optical Signal Detection
• Across a fiber span, optical signals encounter attenuation, dispersion
and increased noise levels at amplifiers.
• Each of these factors causes bit detection errors at the receiver.
Transmitting Receiving
end Distance (km) end
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 19
OSNR Solution #1: Forward Error Correction
• FEC extends reach and design 0
flexibility, at “silicon cost” –1
–2 Raw Channel BER=1.5e-3
• G.709 (G.709 Annex A) standard –3
improves –4
OSNR tolerance by 6.2 dB (at 10–15 –5
–6
BER)
–7
(BER)
Log
• Offers intrinsic performance monitoring –8
–9
(error statistics) –10
G.709
RS(255,239)
Uncoded
• Higher gains (8.4dB) possible by –11
No FEC
–12
enhanced FEC (with same G.709 –13
overhead – G.975.1 I.4) –14
EFEC=8.4 dB
FEC=6.2 dB
–15
• New SD-FEC provides 2dB more 4 5 6 7 8 9 10 11 12 13 14 15
coding gain S/N (dB)
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 21
Final Solution: Regeneration
Regeneration involves the 3‘R’s:
e- Reshape Retime Reamplify
e-
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 22
DWDM Components
Typical Components of DWDM Systems
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 24
Optical Transmitter Block Diagram
Detects pulses of electrical charge Creates pulses of light
• Power measured in watts (W) • Power measured in
• Amplitude measured in decibel-milliwatts (dBm)
volts (V) • Relative amplitude
measured in decibels (dB)
Electrical-to-optical
+ 1 0 1 1 (E-O) conversion + 1 0 1 1
+ - V dB
- -
E-O
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 25
100G and Beyond – Coherent Detection
Direct Detection
• Must correct for impairments in the physical domain (insert DCU’s)
• Forced to live with non-correctable impairments via network design (limit distance,
regenerate, adjust channel spacing)
• Dumb detection (OOK), no Digital Signal Processing, only FEC
DCU DCU DCU
DD DD
• Moves impairment correction from the optical domain into the digital domain
• Allows for digital correction of impairments (powerful DSP) vs. physical correction
of impairments (DCU’s). Adds advanced FEC.
• Massive performance improvements over Direct Detection.
CD
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 26
Optical Receiver Block Diagram
Detects pulses of light Creates pulses of electrical charge
• Power measured in • Power measured in watts (W)
decibel-milliwatt (dBm) • Amplitude measured in volts (V)
• Relative amplitude
measured in decibels (dB)
Optical-to-electrical
(O-E) conversion
+ 1 0 1 1 + 1 0 1 1
dB V
- - + -
O-E
3 3
DWDM
fiber
N N
From N To N
transmitters Multiplexer Demultiplexer receivers
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 28
OADM Block Diagram
OADM
one/n signal/s
DWDM
fiber
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 29
Simple ROADM Architecture
Software Controlled Selectors – n Ch.
(Pass-through/Add/Block)
West Pass
Pass-Through Wavelengths
Splitter
DWDM
Add
Pass
Signal
Software
Controlled
Add block block drop
n Ch. Demux drop
Add
Transponder Drop
Wavelengths
Module Wavelengths
Drop Transponder
Add Module
Wavelengths
drop block drop block Software Wavelengths
Controlled Add
n Ch. Demux
DWDM Pass
Signal Pass-Through Wavelengths
East
Add
Splitter
Pass
Amplified output
Attenuated input composite signal
composite signal
DWDM
fiber OA
Powerin Powerout
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 31
Transponder Block Diagram
ITU-T
compliant wavelength
Non-ITU-T
compliant wavelength
O-E-O
wavelength conversion
Tx 15xx.xx nm
850, 1310, 1550 nm
Transponder
G.709 Enabled
Optical fiber Rx
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 32
Muxponder Block Diagram ITU-T
compliant wavelength
Multiple Non-ITU-T Multiplexing and O-E-O
Compliant Clients wavelength conversion
G.709 Enabled
Rx
Optical fibers
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 33
DWDM or Gray Pluggable Optics
1G/10G
SFP/SFP+
40G/100G/400G
10G/40G/100G/400G
QSFP56-DD CFP2, CFP, CPAK and CXP SFP+/QSFP+/QSFP28/QSFP56-DD
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 34
400ZR/ZR+ Target Reaches
Specification Framing Data Rate Modulation Target Reach
* CD limited
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 35
DWDM System
Transponder interface
Tx Rx
OEO OEO
Rx Tx
Client OA OADM OA Client
Tx Rx
Rx Tx
Rx Tx
Mux and Mux and
demux demux
To client devices
Direct interface
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 36
Increasing Network
Capacity and Reach
Traditionally DWDM capacity is limited by the
channel spacing imposed by the 50GHz ITU grid.
50 GHz ITU Grid “Gridless or FlexSpectrum”
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 38
ROADM brought flexibility to DWDM networks.
Any wavelength. Anywhere.
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 39
… because ROADM ports were
colored and directional.
Colored Add/Drop Directional Add/Drop
Fixed port frequency assignment Physical add/drop port is tied to a
One unique frequency per port ROADM “degree”
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 40
Colorless and Omni-directional add/drop bring
touchless flexibility, and hence programmability, to
ROADM networks.
Colorless Add/Drop Omni-Directional Add/Drop
No port-frequency assignment Add/Drop ports can be routed
Any frequency, any port to/from any ROADM degree
With Colorless plus Omni-Directional, the frequency and direction of the signal
can be changed, without requiring a change of ROADM add/drop port, therefore
no truckrolls, and hence…programmability!
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 41
But…Colorless and Omni-directional introduce
wavelength contention at the add/drop stage.
Need a Contentionless architecture.
Directional Add/Drop ROADMs Contentionless add/drop allows
form a Contentionless node by multiple instances of the same
definition. frequency to A/D from one unit.
Tunable lasers work with colorless add/drop to enable touchless changes in the
frequency of an optical signal. Coherent receivers simplify the construction of
colorless and omni-directional ROADM nodes, by eliminating the need to de-
multiplex a signal down to the individual wavelength.
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 43
animated slide
Dynamic Optical Restoration
ROADM Network
Client Client
Transponder Transponder
Shelf Shelf
Fiber Cut!
Embedded FLOW intelligence locates and verifies a new path and wavelength
Transponders re-tune to available wavelength
Colorless, Omni-Directional ROADM switches the path
Service is brought back up with the same Client and Optical interfaces, zero touches
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 44
To Conclude: why SSON/Cisco FLOW?
SSON: https://tools.ietf.org/html/rfc7698
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 45
Building a Real DWDM
Network
Value of building Private Fiber Optic Networks
• Control • Security and Encryption
• Almost unlimited capacity • Scalability – pay as you grow,
new service offerings
• Separate large number of
services over a single fiber • Predictable costs
• High System Availability during • Monitoring and additional
outages services
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 47
Today’s Challenge – Build a Private Fiber Optic
Network
• Large company has a subsidiary who needs a 10G capable network
• 5 industrial remote sites (some ~60 miles apart), expandable to 7
• 2 physically separate networks, deliver shared and discreet
services
• Some services are critical, minimum interruption required (99.999%
availability)
• Industrial Control System, Corporate Access, Telephony, CCTV,
Welfare Internet (future)
• Infrastructure to last 15 years
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 48
How would such a network look like w/o DWDM?
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 49
How would such a network look like w/o DWDM?
70km 10km
20km
80km
2km
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 50
How would such a network look like w/o DWDM?
Repeater?
70km 10km
Repeater?
20km
80km
2km
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 51
How would such a network look like w/o DWDM?
Repeater?
70km 10km
Repeater?
20km
80km
2km
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 52
How would such a network look like w/o DWDM?
Repeater?
70km 10km
20km
Repeater?
80km
2km
2km
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 53
Let us build a DWDM network..
• Maximize Fiber Efficiency Grey Optics
• Longer reach
• Increased Capacity
• Improved Visibility
Grey Optics Grey Optics
• Multiple Connections
• Management Grey Optics Grey Optics
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 54
Wavelength/Lambda/Frequency Services
COMPLIES WITH
J UNE 24, 2007
SF
FAIL
ACT
RX RX RX RX RX RX
LEVEL 1M
HAZARD
MX
MX
MX
MX
MX
MX
1-C
40-SMR
TX TX TX TX TX TX
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 56
NCS2006 Chassis
DC LCD DC
15454-M6-AC 15454-M6-AC
RET -48V RET RET -48V RET
A B
-48V -48V
CLEI CODE CLEI CODE
SLOT STATUS PORT CRIT MAJ MIN
AC MAINS INPUT -48V
CAUTION: AC MAINS INPUT -48V
CAUTION:
100-240 V~ DOUBLE POLE 100-240 V~ DOUBLE POLE
12-5 A, 50/60Hz
30A
NEUTRAL /FUSING 12-5 A, 50/60Hz
30A
NEUTRAL /FUSING
RX
RX
TX
TX
MIN REM
SYNC ACO
CRIT MAJ
LAMP TEST
EIA/TIA-232
TNCE
ACT/STBY
TCP/IP
COMPLIES WITH 21 CFR 1040.10
PWR
B
AND 1040.11 EXCEPT FOR
SFP1
SFP2
ACO
A
DEVIATIONS PURSUANT TO
FAIL
LASER NOTICE No.50.
LINK
DATED JUNE 24, 2007
ACT
8
LINK
LINK
ACT
ACT
7
6
FAN
5
4
3
2
CLEI CODE
RX
RX
TX
TX
MIN REM
SYNC ACO
CRIT MAJ
LAMP TEST
EIA/TIA-232
TNCE
ACT/STBY
TCP/IP
SFP1
SFP2
ACO
A
DEVIATIONS PURSUANT TO
FAIL
1
LINK
LINK
LINK
ACT
ACT
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 57
PN SN
PID/VID
CLEI CODE
AC 1533.4 nm 1532.6 nm 1531.9 nm 1531.1 nm 1530.3 nm
1
RET
RX TX RX TX RX TX RX TX RX TX
FAN
FTA
100-240 V~
12-5 A, 50/60Hz
-48V
B A B A B A B A B A
MAINS INPUT
RX TX RX TX RX TX RX TX RX TX
40-SMR
TNCE TNCE
30A
-48V
1-C B A B A B A B A B A
NEUTRAL /FUSING
DOUBLE POLE
CAUTION:
15454-M6-AC
RX TX RX TX RX TX RX TX RX TX
Cabling a Site…
CLEI CODE
DC
B A B A B A B A B A
RET
-48V
RX TX RX TX RX TX RX TX RX TX
CRIT MAJ CRIT MAJ
HAZARD
LEVEL 1M B A B A B A B A B A
MIN REM MIN REM
TX
1553.3 nm 1552.5 nm 1551.7 nm 1550.9 nm 1550.1 nm
RX
6
ACO MX ACO RX TX RX TX RX TX RX TX RX TX
MON
LAMP TEST LAMP TEST
B A B A B A B A B A
A
TX
RX
1557.3 nm 1556.5 nm 1555.7 nm 1554.9 nm 1554.1 nm
LINK MX LINK
7
RX TX RX TX RX TX RX TX RX TX
EXP
ACT ACT
B A B A B A B A B A
TCP/IP TCP/IP
TX
RX
MX
SLOT STATUS PORT
RX TX RX TX RX TX RX TX RX TX
DC
EIA/TIA-232 EIA/TIA-232 B A B A B A B A B A
TX
RX
MX
CRIT MAJ
LCD
#CiscoLive
OSC
MIN
B
TX
RX
MX
ADD & DROP
AC
SFP1 SFP1
TX
RX
TX TX
RET
LINK LINK
100-240 V~
MX
12-5 A, 50/60Hz
-48V
ACT ACT
LINE
RX RX
COM EMPTY MON AUX MON
MAINS INPUT
9
DGTL-BRKOPT-2007
DATED JUNE 24, 2007
DATED JUNE 24, 2007
DEVIATIONS PURSUANT TO
DEVIATIONS PURSUANT TO
-48V
15216-MD-40-ODD=
1 2 3 4 5 6 7 8
© 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public
58
PN SN
PID/VID
CLEI CODE
AC 1533.4 nm 1532.6 nm 1531.9 nm 1531.1 nm 1530.3 nm
1
RET
RX TX RX TX RX TX RX TX RX TX
FAN
FTA
100-240 V~
12-5 A, 50/60Hz
-48V
B A B A B A B A B A
MAINS INPUT
RX TX RX TX RX TX RX TX RX TX
40-SMR
TNCE TNCE
30A
-48V
1-C B A B A B A B A B A
NEUTRAL /FUSING
DOUBLE POLE
CAUTION:
15454-M6-AC
RX TX RX TX RX TX RX TX RX TX
Cabling a Site…
CLEI CODE
DC
B A B A B A B A B A
RET
-48V
RX TX RX TX RX TX RX TX RX TX
CRIT MAJ CRIT MAJ
HAZARD
LEVEL 1M B A B A B A B A B A
MIN REM MIN REM
TX
1553.3 nm 1552.5 nm 1551.7 nm 1550.9 nm 1550.1 nm
RX
6
ACO MX ACO RX TX RX TX RX TX RX TX RX TX
MON
LAMP TEST LAMP TEST
Mon B A B A B A B A B A
A
TX
RX
1557.3 nm 1556.5 nm 1555.7 nm 1554.9 nm 1554.1 nm
LINK MX LINK
7
RX TX RX TX RX TX RX TX RX TX
EXP
ACT ACT
Express
B A B A B A B A B A
TCP/IP TCP/IP
TX
RX
MX
SLOT STATUS PORT
RX TX RX TX RX TX RX TX RX TX
DC
DC
EIA/TIA-232 EIA/TIA-232 B A B A B A B A B A
TX
RX
MX
CRIT MAJ
LCD
#CiscoLive
OSC
MIN
OSC
B
TX
RX
MX
Add/Drop
ADD & DROP
AC
SFP1 SFP1
TX
RX
TX TX
RET
LINK LINK
100-240 V~
MX
12-5 A, 50/60Hz
-48V
ACT ACT
LINE
RX RX
COM EMPTY MON AUX MON
MAINS INPUT
9
COMPLIES WITH
INV
DGTL-BRKOPT-2007
DATED JUNE 24, 2007
DATED JUNE 24, 2007
DEVIATIONS PURSUANT TO
DEVIATIONS PURSUANT TO
-48V
15216-MD-40-ODD=
1 2 3 4 5 6 7 8
© 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public
59
PN SN
PID/VID
CLEI CODE
AC 1533.4 nm 1532.6 nm 1531.9 nm 1531.1 nm 1530.3 nm
1
RET
RX TX RX TX RX TX RX TX RX TX
FAN
FTA
100-240 V~
12-5 A, 50/60Hz
-48V
B A B A B A B A B A
MAINS INPUT
RX TX RX TX RX TX RX TX RX TX
40-SMR
TNCE TNCE
30A
-48V
1-C B A B A B A B A B A
NEUTRAL /FUSING
DOUBLE POLE
CAUTION:
15454-M6-AC
RX TX RX TX RX TX RX TX RX TX
Cabling a Site…
CLEI CODE
DC
B A B A B A B A B A
RET
-48V
RX TX RX TX RX TX RX TX RX TX
CRIT MAJ CRIT MAJ
HAZARD
LEVEL 1M B A B A B A B A B A
MIN REM MIN REM
TX
1553.3 nm 1552.5 nm 1551.7 nm 1550.9 nm 1550.1 nm
RX
6
ACO MX ACO RX TX RX TX RX TX RX TX RX TX
MON
LAMP TEST LAMP TEST
Mon B A B A B A B A B A
A
TX
RX
1557.3 nm 1556.5 nm 1555.7 nm 1554.9 nm 1554.1 nm
LINK MX LINK
7
RX TX RX TX RX TX RX TX RX TX
EXP
ACT ACT
Express
B A B A B A B A B A
TCP/IP TCP/IP
TX
RX
MX
SLOT STATUS PORT
RX TX RX TX RX TX RX TX RX TX
DC
DC
EIA/TIA-232 EIA/TIA-232 B A B A B A B A B A
TX
RX
MX
CRIT MAJ
LCD
#CiscoLive
OSC
MIN
OSC
B
TX
RX
MX
Add/Drop
ADD & DROP
AC
SFP1 SFP1
TX
RX
TX TX
RET
LINK LINK
100-240 V~
MX
12-5 A, 50/60Hz
-48V
ACT ACT
LINE
RX RX
COM EMPTY MON AUX MON
MAINS INPUT
9
COMPLIES WITH
INV
DGTL-BRKOPT-2007
DATED JUNE 24, 2007
DATED JUNE 24, 2007
DEVIATIONS PURSUANT TO
DEVIATIONS PURSUANT TO
-48V
15216-MD-40-ODD=
1 2 3 4 5 6 7 8
© 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public
60
Toward next site
PN SN
PID/VID
CLEI CODE
AC 1533.4 nm 1532.6 nm 1531.9 nm 1531.1 nm 1530.3 nm
1
RET
RX TX RX TX RX TX RX TX RX TX
FAN
FTA
100-240 V~
12-5 A, 50/60Hz
-48V
B A B A B A B A B A
MAINS INPUT
RX TX RX TX RX TX RX TX RX TX
40-SMR
TNCE TNCE
30A
-48V
1-C B A B A B A B A B A
NEUTRAL /FUSING
DOUBLE POLE
CAUTION:
15454-M6-AC
RX TX RX TX RX TX RX TX RX TX
Cabling a Site…
CLEI CODE
DC
B A B A B A B A B A
RET
-48V
RX TX RX TX RX TX RX TX RX TX
CRIT MAJ CRIT MAJ
HAZARD
LEVEL 1M B A B A B A B A B A
MIN REM MIN REM
TX
1553.3 nm 1552.5 nm 1551.7 nm 1550.9 nm 1550.1 nm
RX
6
ACO MX ACO RX TX RX TX RX TX RX TX RX TX
MON
LAMP TEST LAMP TEST
Mon B A B A B A B A B A
A
TX
RX
1557.3 nm 1556.5 nm 1555.7 nm 1554.9 nm 1554.1 nm
LINK MX LINK
7
RX TX RX TX RX TX RX TX RX TX
EXP
ACT ACT
Express
B A B A B A B A B A
TCP/IP TCP/IP
TX
RX
MX
SLOT STATUS PORT
RX TX RX TX RX TX RX TX RX TX
DC
DC
EIA/TIA-232 EIA/TIA-232 B A B A B A B A B A
TX
RX
MX
CRIT MAJ
LCD
#CiscoLive
OSC
MIN
OSC
B
TX
RX
MX
Add/Drop
ADD & DROP
AC
SFP1 SFP1
TX
RX
TX TX
RET
LINK LINK
100-240 V~
MX
12-5 A, 50/60Hz
-48V
ACT ACT
LINE
RX RX
COM EMPTY MON AUX MON
MAINS INPUT
9
COMPLIES WITH
INV
DGTL-BRKOPT-2007
DATED JUNE 24, 2007
DATED JUNE 24, 2007
DEVIATIONS PURSUANT TO
DEVIATIONS PURSUANT TO
-48V
15216-MD-40-ODD=
1 2 3 4 5 6 7 8
© 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public
61
Toward next site
PN SN
PID/VID
CLEI CODE
AC 1533.4 nm 1532.6 nm 1531.9 nm 1531.1 nm 1530.3 nm
1
RET
RX TX RX TX RX TX RX TX RX TX
FAN
FTA
100-240 V~
12-5 A, 50/60Hz
-48V
B A B A B A B A B A
MAINS INPUT
RX TX RX TX RX TX RX TX RX TX
40-SMR
TNCE TNCE
30A
-48V
1-C B A B A B A B A B A
NEUTRAL /FUSING
DOUBLE POLE
CAUTION:
15454-M6-AC
RX TX RX TX RX TX RX TX RX TX
Cabling a Site…
CLEI CODE
DC
B A B A B A B A B A
RET
-48V
RX TX RX TX RX TX RX TX RX TX
CRIT MAJ CRIT MAJ
HAZARD
LEVEL 1M B A B A B A B A B A
MIN REM MIN REM
TX
1553.3 nm 1552.5 nm 1551.7 nm 1550.9 nm 1550.1 nm
RX
6
ACO MX ACO RX TX RX TX RX TX RX TX RX TX
MON
LAMP TEST LAMP TEST
Mon B A B A B A B A B A
A
TX
RX
1557.3 nm 1556.5 nm 1555.7 nm 1554.9 nm 1554.1 nm
LINK MX LINK
7
RX TX RX TX RX TX RX TX RX TX
EXP
ACT ACT
Express
B A B A B A B A B A
TCP/IP TCP/IP
TX
RX
MX
SLOT STATUS PORT
RX TX RX TX RX TX RX TX RX TX
DC
DC
EIA/TIA-232 EIA/TIA-232 B A B A B A B A B A
TX
RX
MX
CRIT MAJ
LCD
#CiscoLive
OSC
MIN
OSC
B
TX
RX
MX
Add/Drop
ADD & DROP
AC
SFP1 SFP1
TX
RX
TX TX
RET
LINK LINK
100-240 V~
MX
12-5 A, 50/60Hz
-48V
ACT ACT
LINE
RX RX
COM EMPTY MON AUX MON
MAINS INPUT
9
COMPLIES WITH
INV
DGTL-BRKOPT-2007
DATED JUNE 24, 2007
DATED JUNE 24, 2007
DEVIATIONS PURSUANT TO
DEVIATIONS PURSUANT TO
-48V
15216-MD-40-ODD=
1 2 3 4 5 6 7 8
© 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public
62
Toward next site
Toward neighbor
PN SN
PID/VID
CLEI CODE
AC 1533.4 nm 1532.6 nm 1531.9 nm 1531.1 nm 1530.3 nm
1
RET
RX TX RX TX RX TX RX TX RX TX
FAN
FTA
100-240 V~
12-5 A, 50/60Hz
-48V
B A B A B A B A B A
MAINS INPUT
RX TX RX TX RX TX RX TX RX TX
40-SMR
TNCE TNCE
30A
-48V
1-C B A B A B A B A B A
NEUTRAL /FUSING
DOUBLE POLE
CAUTION:
15454-M6-AC
RX TX RX TX RX TX RX TX RX TX
Cabling a Site…
CLEI CODE
DC
B A B A B A B A B A
RET
-48V
RX TX RX TX RX TX RX TX RX TX
CRIT MAJ CRIT MAJ
HAZARD
LEVEL 1M B A B A B A B A B A
MIN REM MIN REM
TX
1553.3 nm 1552.5 nm 1551.7 nm 1550.9 nm 1550.1 nm
RX
6
ACO MX ACO RX TX RX TX RX TX RX TX RX TX
MON
LAMP TEST LAMP TEST
Mon B A B A B A B A B A
A
TX
RX
1557.3 nm 1556.5 nm 1555.7 nm 1554.9 nm 1554.1 nm
LINK MX LINK
7
RX TX RX TX RX TX RX TX RX TX
EXP
ACT ACT
Express
B A B A B A B A B A
TCP/IP TCP/IP
TX
RX
MX
SLOT STATUS PORT
RX TX RX TX RX TX RX TX RX TX
DC
DC
EIA/TIA-232 EIA/TIA-232 B A B A B A B A B A
TX
RX
MX
CRIT MAJ
LCD
#CiscoLive
OSC
MIN
OSC
B
TX
RX
MX
Add/Drop
ADD & DROP
AC
SFP1 SFP1
TX
RX
TX TX
RET
LINK LINK
100-240 V~
MX
12-5 A, 50/60Hz
-48V
ACT ACT
LINE
RX RX
COM EMPTY MON AUX MON
MAINS INPUT
9
COMPLIES WITH
INV
DGTL-BRKOPT-2007
DATED JUNE 24, 2007
DATED JUNE 24, 2007
DEVIATIONS PURSUANT TO
DEVIATIONS PURSUANT TO
-48V
15216-MD-40-ODD=
1 2 3 4 5 6 7 8
© 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public
63
Toward next site
Toward neighbor
PN SN
PID/VID
CLEI CODE
AC 1533.4 nm 1532.6 nm 1531.9 nm 1531.1 nm 1530.3 nm
1
RET
RX TX RX TX RX TX RX TX RX TX
FAN
FTA
100-240 V~
12-5 A, 50/60Hz
-48V
B A B A B A B A B A
MAINS INPUT
RX TX RX TX RX TX RX TX RX TX
40-SMR
TNCE TNCE
30A
-48V
1-C B A B A B A B A B A
NEUTRAL /FUSING
DOUBLE POLE
CAUTION:
15454-M6-AC
RX TX RX TX RX TX RX TX RX TX
Cabling a Site…
CLEI CODE
DC
B A B A B A B A B A
RET
-48V
RX TX RX TX RX TX RX TX RX TX
CRIT MAJ CRIT MAJ
HAZARD
LEVEL 1M B A B A B A B A B A
MIN REM MIN REM
TX
1553.3 nm 1552.5 nm 1551.7 nm 1550.9 nm 1550.1 nm
RX
6
ACO MX ACO RX TX RX TX RX TX RX TX RX TX
MON
LAMP TEST LAMP TEST
Mon B A B A B A B A B A
A
TX
RX
1557.3 nm 1556.5 nm 1555.7 nm 1554.9 nm 1554.1 nm
LINK MX LINK
7
RX TX RX TX RX TX RX TX RX TX
EXP
ACT ACT
Express
B A B A B A B A B A
TCP/IP TCP/IP
TX
RX
MX
SLOT STATUS PORT
RX TX RX TX RX TX RX TX RX TX
DC
DC
EIA/TIA-232 EIA/TIA-232 B A B A B A B A B A
TX
RX
MX
CRIT MAJ
LCD
#CiscoLive
OSC
MIN
OSC
B
TX
RX
MX
Add/Drop
ADD & DROP
AC
SFP1 SFP1
TX
RX
TX TX
RET
LINK LINK
100-240 V~
MX
12-5 A, 50/60Hz
-48V
ACT ACT
LINE
RX RX
COM EMPTY MON AUX MON
MAINS INPUT
9
COMPLIES WITH
INV
DGTL-BRKOPT-2007
DATED JUNE 24, 2007
DATED JUNE 24, 2007
DEVIATIONS PURSUANT TO
DEVIATIONS PURSUANT TO
-48V
15216-MD-40-ODD=
1 2 3 4 5 6 7 8
© 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public
64
Toward next site
Toward neighbor
PN SN
PID/VID
CLEI CODE
AC 1533.4 nm 1532.6 nm 1531.9 nm 1531.1 nm 1530.3 nm
1
RET
RX TX RX TX RX TX RX TX RX TX
FAN
FTA
100-240 V~
12-5 A, 50/60Hz
-48V
B A B A B A B A B A
MAINS INPUT
RX TX RX TX RX TX RX TX RX TX
40-SMR
TNCE TNCE
30A
-48V
100G-LC-C
1-C B A B A B A B A B A
NEUTRAL /FUSING
DOUBLE POLE
CAUTION:
15454-M6-AC
RX TX RX TX RX TX RX TX RX TX
Cabling a Site…
CLEI CODE
DC
B A B A B A B A B A
RET
-48V
ACT/STBY SF ACT/STBY B A B A B A B A B A
RX TX RX TX RX TX RX TX RX TX
CRIT MAJ CRIT MAJ
HAZARD
LEVEL 1M B A B A B A B A B A
MIN REM MIN REM
TX
1553.3 nm 1552.5 nm 1551.7 nm 1550.9 nm 1550.1 nm
RX
6
ACO MX ACO
AGGR
RX TX RX TX RX TX RX TX RX TX
MON
LAMP TEST LAMP TEST
Mon B A B A B A B A B A
TX
RX
A
TX
RX
TRUNK
RX TX RX TX RX TX RX TX RX TX
EXP
ACT ACT
Express
B A B A B A B A B A
TCP/IP TCP/IP
TX
RX
MX
SLOT STATUS PORT
RX TX RX TX RX TX RX TX RX TX
DC
DC
EIA/TIA-232 EIA/TIA-232 B A B A B A B A B A
TX
RX
MX
CRIT MAJ
LCD
#CiscoLive
OSC
MIN
OSC
B
TX
RX
MX
Add/Drop
ADD & DROP
LEVEL 1
HAZARD
AC
SFP1 SFP1
TX
RX
TX TX
RET
LINK LINK
100-240 V~
MX
12-5 A, 50/60Hz
-48V
ACT ACT
LINE
RX RX
COM EMPTY MON AUX MON
MAINS INPUT
9
COMPLIES WITH
DATED JUNE 24, 2007
LASER NOTICE No.50.
INV
A
COMPLIES WITH 21 CFR 1040.10
DGTL-BRKOPT-2007
DATED JUNE 24, 2007
DATED JUNE 24, 2007
DEVIATIONS PURSUANT TO
DEVIATIONS PURSUANT TO
-48V
15216-MD-40-ODD=
1 2 3 4 5 6 7 8
© 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public
65
Toward next site
Toward neighbor
PN SN
PID/VID
CLEI CODE
AC 1533.4 nm 1532.6 nm 1531.9 nm 1531.1 nm 1530.3 nm
1
RET
RX TX RX TX RX TX RX TX RX TX
FAN
FTA
100-240 V~
12-5 A, 50/60Hz
-48V
B A B A B A B A B A
MAINS INPUT
RX TX RX TX RX TX RX TX RX TX
40-SMR
TNCE TNCE
30A
-48V
100G-LC-C
100G-LC-C
1-C B A B A B A B A B A
NEUTRAL /FUSING
DOUBLE POLE
CAUTION:
15454-M6-AC
RX TX RX TX RX TX RX TX RX TX
Cabling a Site…
CLEI CODE
DC
B A B A B A B A B A
RET
-48V
SF
ACT/STBY SF ACT/STBY B A B A B A B A B A
RX TX RX TX RX TX RX TX RX TX
CRIT MAJ CRIT MAJ
HAZARD
LEVEL 1M B A B A B A B A B A
MIN REM MIN REM
TX
1553.3 nm 1552.5 nm 1551.7 nm 1550.9 nm 1550.1 nm
RX
6
ACO MX ACO
AGGR
AGGR
RX TX RX TX RX TX RX TX RX TX
MON
1
RX
A
TX
RX
TRUNK
LINK MX LINK
7
RX TX RX TX RX TX RX TX RX TX
EXP
ACT ACT
Express
3
B A B A B A B A B A
TCP/IP TCP/IP
TX
RX
MX
SLOT STATUS PORT
RX TX RX TX RX TX RX TX RX TX
DC
DC
EIA/TIA-232 EIA/TIA-232 B A B A B A B A B A
TX
RX
MX
CRIT MAJ
5
LCD
#CiscoLive
OSC
MIN
OSC
B
TX
RX
MX
7
Add/Drop
ADD & DROP
LEVEL 1
HAZARD
AC
SFP1 SFP1
TX
RX
8
TX TX
RET
LINK LINK
100-240 V~
MX
12-5 A, 50/60Hz
-48V
ACT ACT
LINE
RX RX
EMPTY
9
COMPLIES WITH
DATED JUNE 24, 2007
LASER NOTICE No.50.
INV
A
COMPLIES WITH 21 CFR 1040.10
RX RX
FOR DEVIATIONS
L-com B A B A B A
SFP2 PURSUANT TO LASER SFP2
NOTICE No.50,DATED
30A
-48V
DGTL-BRKOPT-2007
DATED JUNE 24, 2007
LASER NOTICE No.50.
DEVIATIONS PURSUANT TO
DEVIATIONS PURSUANT TO
-48V
15216-MD-40-ODD=
1 2 3 4 5 6 7 8
© 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public
66
Toward next site
Toward LAN
Toward neighbor
PN SN
PID/VID
CLEI CODE
AC 1533.4 nm 1532.6 nm 1531.9 nm 1531.1 nm 1530.3 nm
1
RET
RX TX RX TX RX TX RX TX RX TX
FAN
FTA
100-240 V~
12-5 A, 50/60Hz
-48V
B A B A B A B A B A
MAINS INPUT
RX TX RX TX RX TX RX TX RX TX
40-SMR
TNCE TNCE
30A
-48V
100G-LC-C
100G-LC-C
1-C B A B A B A B A B A
NEUTRAL /FUSING
DOUBLE POLE
CAUTION:
15454-M6-AC
RX TX RX TX RX TX RX TX RX TX
Cabling a Site…
CLEI CODE
DC
B A B A B A B A B A
RET
-48V
SF
ACT/STBY SF ACT/STBY B A B A B A B A B A
RX TX RX TX RX TX RX TX RX TX
CRIT MAJ CRIT MAJ
HAZARD
LEVEL 1M B A B A B A B A B A
MIN REM MIN REM
TX
1553.3 nm 1552.5 nm 1551.7 nm 1550.9 nm 1550.1 nm
RX
6
ACO MX ACO
AGGR
AGGR
RX TX RX TX RX TX RX TX RX TX
MON
1
RX
A
TX
RX
TRUNK
LINK MX LINK
7
RX TX RX TX RX TX RX TX RX TX
EXP
ACT ACT
Express
3
B A B A B A B A B A
TCP/IP TCP/IP
TX
RX
MX
SLOT STATUS PORT
RX TX RX TX RX TX RX TX RX TX
DC
DC
EIA/TIA-232 EIA/TIA-232 B A B A B A B A B A
TX
RX
MX
CRIT MAJ
5
LCD
#CiscoLive
OSC
MIN
OSC
B
TX
RX
MX
7
Add/Drop
ADD & DROP
LEVEL 1
HAZARD
AC
SFP1 SFP1
TX
RX
8
TX TX
RET
LINK LINK
100-240 V~
MX
12-5 A, 50/60Hz
-48V
ACT ACT
LINE
RX RX
EMPTY
9
COMPLIES WITH
DATED JUNE 24, 2007
LASER NOTICE No.50.
INV
A
COMPLIES WITH 21 CFR 1040.10
RX RX
FOR DEVIATIONS
L-com B A B A B A
SFP2 PURSUANT TO LASER SFP2
NOTICE No.50,DATED
30A
-48V
DGTL-BRKOPT-2007
DATED JUNE 24, 2007
LASER NOTICE No.50.
DEVIATIONS PURSUANT TO
DEVIATIONS PURSUANT TO
-48V
15216-MD-40-ODD=
1 2 3 4 5 6 7 8
© 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public
67
Toward next site
Toward LAN
Toward neighbor
PN SN
PID/VID
CLEI CODE
AC 1533.4 nm 1532.6 nm 1531.9 nm 1531.1 nm 1530.3 nm
1
RET
RX TX RX TX RX TX RX TX RX TX
FAN
FTA
100-240 V~
12-5 A, 50/60Hz
-48V
B A B A B A B A B A
MAINS INPUT
RX TX RX TX RX TX RX TX RX TX
40-SMR
TNCE TNCE
30A
-48V
100G-LC-C
100G-LC-C
1-C B A B A B A B A B A
NEUTRAL /FUSING
DOUBLE POLE
CAUTION:
15454-M6-AC
RX TX RX TX RX TX RX TX RX TX
Cabling a Site…
CLEI CODE
DC
B A B A B A B A B A
RET
-48V
SF
ACT/STBY SF ACT/STBY B A B A B A B A B A
RX TX RX TX RX TX RX TX RX TX
CRIT MAJ CRIT MAJ
HAZARD
LEVEL 1M B A B A B A B A B A
MIN REM MIN REM
TX
1553.3 nm 1552.5 nm 1551.7 nm 1550.9 nm 1550.1 nm
RX
6
ACO MX ACO
AGGR
AGGR
RX TX RX TX RX TX RX TX RX TX
MON
1
RX
A
TX
RX
TRUNK
LINK MX LINK
7
RX TX RX TX RX TX RX TX RX TX
EXP
ACT ACT
Express
3
B A B A B A B A B A
TCP/IP TCP/IP
TX
RX
MX
SLOT STATUS PORT
RX TX RX TX RX TX RX TX RX TX
DC
DC
EIA/TIA-232 EIA/TIA-232 B A B A B A B A B A
TX
RX
MX
CRIT MAJ
5
LCD
#CiscoLive
OSC
MIN
OCS
B
TX
RX
MX
7
Add/Drop
ADD & DROP
LEVEL 1
HAZARD
AC
SFP1 SFP1
TX
RX
8
TX TX
RET
LINK LINK
100-240 V~
MX
12-5 A, 50/60Hz
-48V
ACT ACT
LINE
RX RX
EMPTY
9
COMPLIES WITH
DATED JUNE 24, 2007
LASER NOTICE No.50.
INV
A
COMPLIES WITH 21 CFR 1040.10
RX RX
FOR DEVIATIONS
L-com B A B A B A
SFP2 PURSUANT TO LASER SFP2
NOTICE No.50,DATED
30A
-48V
DGTL-BRKOPT-2007
DATED JUNE 24, 2007
LASER NOTICE No.50.
DEVIATIONS PURSUANT TO
DEVIATIONS PURSUANT TO
-48V
15216-MD-40-ODD=
1 2 3 4 5 6 7 8
© 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public
68
Toward next site
Connecting Sites…
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 69
What a DWDM Engineer Sees…
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 70
What a DWDM Engineer Sees…
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 71
Wavelength/Lambda 1 – Corporate Network
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 72
Wavelength/Lambda 2 – CCTV
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 73
Wavelength/Lambda 3 – Industrial to Bravo
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 74
Wavelength/Lambda 4 – Industrial to Charlie
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 75
Wavelength/Lambda 5 – Industrial to Delta
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 76
Wavelength/Lambda 6 – Industrial to Echo
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 77
What a DWDM Engineer Sees…
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 78
The Complete Picture…
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 79
Type of Services…
A M
T X
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 80
Building Arbitrary and Redundant Topologies…
Alpha
• Single Span
Bravo • Linear
• Ring
Charlie Delta • Mesh=Multi-Ring
• Degrees
Indigo
Juliette Kilo
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 81
Redundancy for Cable Failures…
• Path Protection – end-to-end protection against failures
• Protected vs Unprotected
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 82
Worst…
• Client Signal Unprotected
Pluggable Pluggable
DWDM
Ring
• 1 client signal
• 1 laser trunk
• 1 path
• No optical protection
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 83
Worst…
• Client Signal Unprotected
Pluggable Pluggable
DWDM
Ring
• 1 client signal
• 1 laser trunk
• 1 path
• No optical protection
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 84
Best and Easiest (1+1)…
• Client-Protected (External to DWDM)
Pluggable Pluggable
DWDM
Pluggable Ring Pluggable
• 2 client signals
• 2 laser trunks
• 2 paths
• No optical protection
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 85
Best and Easiest (1+1)…
• Client-Protected (External to DWDM)
Pluggable Pluggable
DWDM
Pluggable Ring Pluggable
• 2 client signals
• 2 laser trunks
• 2 paths
• No optical protection
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 86
Also an Option…
• Client Unprotected
• 1 client signal
• 1 laser trunk
• 2 paths
• Optical protection
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 87
Also an Option…
• Client Unprotected
• 1 client signal
• 1 laser trunk
• 2 paths
• Optical protection
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 88
What is Cisco Network Planner (CNP)?
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 89
Conclusion
• DWDM is Agnostic and Flexible
• DWDM can reduce costs of fixed assets (i.e. OSP Fiber)
• DWDM is enabler of Network Capacity Expansion
• DWDM has involved to become easier to operate, smaller, and
provide increased Capacity
#CiscoLive DGTL-BRKOPT-2007 © 2020 Cisco and/or its affiliates. All rights reserved. Cisco Public 90
Thank you
#CiscoLive
#CiscoLive