WAG9x and WAP7x

Trouble shooting guide CCU

Owner: Responsible unit: Doc. kind: Reference designation:


MO RS LM EN CCI2 CCU Fault locating instructions -TS_RGC07 &EDC023
Prepared: Doc.-state: SMO RS LMC
Bhagyashri Narule in work
Satyam Kumar Trouble shooting guide WAG9x and
Checked: WAP7x CCU
Ashok Tripathy
Approved: File name:
Trouble shooting guide WAG9x Index: Date: Language: Pages:
Amod Dange and WAP7x CCU.docx B 2020-12-03 EN 1/590
Customer: Date: Approved: Issue: Date:
Ident-No.:
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Revision history
Version Date Sections changed Reason for change
A All First Issue Layout Concept (Release
WAG9_Upgrade)

Unresolved issues
No. Topic Chapter To be resolved no late than
by

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 2/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
List of Contents
0 Introduction ............................................................................................................................ 12
0.1 General information about this document........................................................................ 12
0.2 Other applicable documents ........................................................................................... 12
0.3 Safety instructions and notes .......................................................................................... 12
0.4 List of abbreviations ........................................................................................................ 13
1 How to use the trouble shooting guide ................................................................................... 15
1.1 Schematic example ........................................................................................................ 16
1.2 Using Circuit diagrams .................................................................................................... 17
1.3 How to check the status of I/Os ...................................................................................... 18
1.4 How to check, if a diagnostic message is still triggered ................................................... 19
2 Trouble shooting guide .......................................................................................................... 20
2.1 Locomotive Overview...................................................................................................... 20
2.1.1 VCU Layout ............................................................................................................. 25
2.1.2 IO Station................................................................................................................. 26
2.2 Structure of the troubleshooting guide ............................................................................ 28
2.3 Definitions ....................................................................................................................... 28
2.3.1 Typical reactions of the control unit (CCU/TCU)....................................................... 28
3 Trouble shooting guide .......................................................................................................... 29
3.1 Cross reference from crew messages to diagnostic messages ....................................... 29
3.2 Diagnostic messages ...................................................................................................... 31
3.2.1 CCU Fault Code 0004.............................................................................................. 31
3.2.2 CCU Fault Code 0005.............................................................................................. 32
3.2.3 CCU Fault Code 0006.............................................................................................. 33
3.2.4 CCU Fault Code 0007.............................................................................................. 34
3.2.5 CCU Fault Code 0008.............................................................................................. 35
3.2.6 CCU Fault Code 0009.............................................................................................. 36
3.2.7 CCU Fault Code 0049.............................................................................................. 37
3.2.8 CCU Fault Code 0060.............................................................................................. 38
3.2.9 CCU Fault Code 0061.............................................................................................. 41
3.2.10 CCU Fault Code 0062.............................................................................................. 44
3.2.11 CCU Fault Code 0063.............................................................................................. 46
3.2.12 CCU Fault Code 0064.............................................................................................. 48
3.2.13 CCU Fault Code 0065.............................................................................................. 50
3.2.14 CCU Fault Code 0066.............................................................................................. 51
3.2.15 CCU Fault Code 0067.............................................................................................. 52
3.2.16 CCU Fault Code 0239.............................................................................................. 54
3.2.17 CCU Fault Code 0240.............................................................................................. 55
3.2.18 CCU Fault Code 0243.............................................................................................. 58
3.2.19 CCU Fault Code 0244.............................................................................................. 61
3.2.20 CCU Fault Code 0255.............................................................................................. 63
3.2.21 CCU Fault Code 0256.............................................................................................. 66
3.2.22 CCU Fault Code 0280.............................................................................................. 68
3.2.23 CCU Fault Code 0281.............................................................................................. 71
3.2.24 CCU Fault Code 0282.............................................................................................. 74
3.2.25 CCU Fault Code 0287.............................................................................................. 77
3.2.26 CCU Fault Code 0295.............................................................................................. 79

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 3/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.27 CCU Fault Code 0340.............................................................................................. 80
3.2.28 CCU Fault Code 0341.............................................................................................. 81
3.2.29 CCU Fault Code 0342.............................................................................................. 82
3.2.30 CCU Fault Code 0343.............................................................................................. 84
3.2.31 CCU Fault Code 0344.............................................................................................. 85
3.2.32 CCU Fault Code 0345.............................................................................................. 86
3.2.33 CCU Fault Code 0346.............................................................................................. 87
3.2.34 CCU Fault Code 0348.............................................................................................. 88
3.2.35 CCU Fault Code 0349.............................................................................................. 89
3.2.36 CCU Fault Code 0364.............................................................................................. 90
3.2.37 CCU Fault Code 0367.............................................................................................. 90
3.2.38 CCU Fault Code 0375.............................................................................................. 93
3.2.39 CCU Fault Code 0384.............................................................................................. 94
3.2.40 CCU Fault Code 0399.............................................................................................. 96
3.2.41 CCU Fault Code 0400.............................................................................................. 97
3.2.42 CCU Fault Code 0403.............................................................................................. 98
3.2.43 CCU Fault Code 0404............................................................................................ 100
3.2.44 CCU Fault Code 0406............................................................................................ 102
3.2.45 CCU Fault Code 0407............................................................................................ 104
3.2.46 CCU Fault Code 0409............................................................................................ 106
3.2.47 CCU Fault Code 0410............................................................................................ 108
3.2.48 CCU Fault Code 0421............................................................................................ 110
3.2.49 CCU Fault Code 0422............................................................................................ 111
3.2.50 CCU Fault Code 0423............................................................................................ 112
3.2.51 CCU Fault Code 0430............................................................................................ 114
3.2.52 CCU Fault Code 0460............................................................................................ 115
3.2.53 CCU Fault Code 0461............................................................................................ 117
3.2.54 CCU Fault Code 0462............................................................................................ 119
3.2.55 CCU Fault Code 0491............................................................................................ 121
3.2.56 CCU Fault Code 0492............................................................................................ 123
3.2.57 CCU Fault Code 0493............................................................................................ 125
3.2.58 CCU Fault Code 0494............................................................................................ 127
3.2.59 CCU Fault Code 0495............................................................................................ 129
3.2.60 CCU Fault Code 0496............................................................................................ 131
3.2.61 CCU Fault Code 0500............................................................................................ 133
3.2.62 CCU Fault Code 0501............................................................................................ 136
3.2.63 CCU Fault Code 0505............................................................................................ 139
3.2.64 CCU Fault Code 0506............................................................................................ 140
3.2.65 CCU Fault Code 0516............................................................................................ 141
3.2.66 CCU Fault Code 0517............................................................................................ 142
3.2.67 CCU Fault Code 0520............................................................................................ 143
3.2.68 CCU Fault Code 0521............................................................................................ 146
3.2.69 CCU Fault Code 0530............................................................................................ 149
3.2.70 CCU Fault Code 0531............................................................................................ 151
3.2.71 CCU Fault Code 0532............................................................................................ 152
3.2.72 CCU Fault Code 0533............................................................................................ 155
3.2.73 CCU Fault Code 0534............................................................................................ 156
3.2.74 CCU Fault Code 0535............................................................................................ 157
3.2.75 CCU Fault Code 0536............................................................................................ 159
3.2.76 CCU Fault Code 0537............................................................................................ 160
3.2.77 CCU Fault Code 0538............................................................................................ 163
3.2.78 CCU Fault Code 0539............................................................................................ 165

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 4/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.79 CCU Fault Code 0540............................................................................................ 167
3.2.80 CCU Fault Code 0541............................................................................................ 168
3.2.81 CCU Fault Code 0542............................................................................................ 169
3.2.82 CCU Fault Code 0543............................................................................................ 171
3.2.83 CCU Fault Code 0545............................................................................................ 173
3.2.84 CCU Fault Code 0546............................................................................................ 175
3.2.85 CCU Fault Code 0550............................................................................................ 176
3.2.86 CCU Fault Code 0551............................................................................................ 178
3.2.87 CCU Fault Code 0553............................................................................................ 181
3.2.88 CCU Fault Code 0554............................................................................................ 183
3.2.89 CCU Fault Code 0556............................................................................................ 185
3.2.90 CCU Fault Code 0557............................................................................................ 187
3.2.91 CCU Fault Code 0560............................................................................................ 189
3.2.92 CCU Fault Code 0561............................................................................................ 191
3.2.93 CCU Fault Code 0570............................................................................................ 193
3.2.94 CCU Fault Code 0571............................................................................................ 195
3.2.95 CCU Fault Code 0572............................................................................................ 196
3.2.96 CCU Fault Code 0573............................................................................................ 197
3.2.97 CCU Fault Code 0574............................................................................................ 197
3.2.98 CCU Fault Code 0582............................................................................................ 198
3.2.99 CCU Fault Code 0583............................................................................................ 199
3.2.100 CCU Fault Code 0594 ........................................................................................ 201
3.2.101 CCU Fault Code 0595 ........................................................................................ 201
3.2.102 CCU Fault Code 0597 ........................................................................................ 203
3.2.103 CCU Fault Code 0598 ........................................................................................ 203
3.2.104 CCU Fault Code 0600 ........................................................................................ 205
3.2.105 CCU Fault Code 0603 ........................................................................................ 205
3.2.106 CCU Fault Code 0604 ........................................................................................ 206
3.2.107 CCU Fault Code 0606 ........................................................................................ 207
3.2.108 CCU Fault Code 0607 ........................................................................................ 209
3.2.109 CCU Fault Code 0610 ........................................................................................ 210
3.2.110 CCU Fault Code 0611 ........................................................................................ 211
3.2.111 CCU Fault Code 0621 ........................................................................................ 212
3.2.112 CCU Fault Code 0622 ........................................................................................ 213
3.2.113 CCU Fault Code 0631 ........................................................................................ 213
3.2.114 CCU Fault Code 0632 ........................................................................................ 214
3.2.115 CCU Fault Code 0633 ........................................................................................ 215
3.2.116 CCU Fault Code 0700 ........................................................................................ 217
3.2.117 CCU Fault Code 0701 ........................................................................................ 219
3.2.118 CCU Fault Code 0702 ........................................................................................ 223
3.2.119 CCU Fault Code 0703 ........................................................................................ 226
3.2.120 CCU Fault Code 0704 ........................................................................................ 228
3.2.121 CCU Fault Code 0705 ........................................................................................ 231
3.2.122 CCU Fault Code 0706 ........................................................................................ 233
3.2.123 CCU Fault Code 0707 ........................................................................................ 237
3.2.124 CCU Fault Code 0708 ........................................................................................ 240
3.2.125 CCU Fault Code 0709 ........................................................................................ 242
3.2.126 CCU Fault Code 0710 ........................................................................................ 245
3.2.127 CCU Fault Code 0711 ........................................................................................ 247
3.2.128 CCU Fault Code 0836 ........................................................................................ 250
3.2.129 CCU Fault Code 0837 ........................................................................................ 252
3.2.130 CCU Fault Code 0870 ........................................................................................ 254

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 5/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.131 CCU Fault Code 0871 ........................................................................................ 256
3.2.132 CCU Fault Code 0872 ........................................................................................ 257
3.2.133 CCU Fault Code 0873 ........................................................................................ 259
3.2.134 CCU Fault Code 0874 ........................................................................................ 261
3.2.135 CCU Fault Code 0875 ........................................................................................ 263
3.2.136 CCU Fault Code 0876 ........................................................................................ 265
3.2.137 CCU Fault Code 0877 ........................................................................................ 267
3.2.138 CCU Fault Code 0878 ........................................................................................ 268
3.2.139 CCU Fault Code 0910 ........................................................................................ 270
3.2.140 CCU Fault Code 0931 ........................................................................................ 272
3.2.141 CCU Fault Code 0933 ........................................................................................ 273
3.2.142 CCU Fault Code 0934 ........................................................................................ 275
3.2.143 CCU Fault Code 0936 ........................................................................................ 278
3.2.144 CCU Fault Code 0947 ........................................................................................ 280
3.2.145 CCU Fault Code 0951 ........................................................................................ 281
3.2.146 CCU Fault Code 0952 ........................................................................................ 283
3.2.147 CCU Fault Code 0953 ........................................................................................ 285
3.2.148 CCU Fault Code 0954 ........................................................................................ 287
3.2.149 CCU Fault Code 0955 ........................................................................................ 289
3.2.150 CCU Fault Code 0956 ........................................................................................ 291
3.2.151 CCU Fault Code 1002 ........................................................................................ 293
3.2.152 CCU Fault Code 1003 ........................................................................................ 295
3.2.153 CCU Fault Code 1158 ........................................................................................ 297
3.2.154 CCU Fault Code 1159 ........................................................................................ 299
3.2.155 CCU Fault Code 1162 ........................................................................................ 301
3.2.156 CCU Fault Code 1300 ........................................................................................ 303
3.2.157 CCU Fault Code 1301 ........................................................................................ 304
3.2.158 CCU Fault Code 1302 ........................................................................................ 305
3.2.159 CCU Fault Code 1303 ........................................................................................ 308
3.2.160 CCU Fault Code 1304 ........................................................................................ 310
3.2.161 CCU Fault Code 1305 ........................................................................................ 312
3.2.162 CCU Fault Code 1306 ........................................................................................ 314
3.2.163 CCU Fault Code 1307 ........................................................................................ 316
3.2.164 CCU Fault Code 1308 ........................................................................................ 318
3.2.165 CCU Fault Code 1310 ........................................................................................ 320
3.2.166 CCU Fault Code 1311 ........................................................................................ 322
3.2.167 CCU Fault Code 1312 ........................................................................................ 324
3.2.168 CCU Fault Code 1313 ........................................................................................ 326
3.2.169 CCU Fault Code 1314 ........................................................................................ 328
3.2.170 CCU Fault Code 1315 ........................................................................................ 330
3.2.171 CCU Fault Code 1316 ........................................................................................ 332
3.2.172 CCU Fault Code 1317 ........................................................................................ 334
3.2.173 CCU Fault Code 1318 ........................................................................................ 336
3.2.174 CCU Fault Code 1319 ........................................................................................ 338
3.2.175 CCU Fault Code 1320 ........................................................................................ 340
3.2.176 CCU Fault Code 1321 ........................................................................................ 342
3.2.177 CCU Fault Code 1322 ........................................................................................ 344
3.2.178 CCU Fault Code 1323 ........................................................................................ 346
3.2.179 CCU Fault Code 1324 ........................................................................................ 348
3.2.180 CCU Fault Code 1325 ........................................................................................ 349
3.2.181 CCU Fault Code 1326 ........................................................................................ 351
3.2.182 CCU Fault Code 1327 ........................................................................................ 353

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 6/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.183 CCU Fault Code 1328 ........................................................................................ 355
3.2.184 CCU Fault Code 1329 ........................................................................................ 357
3.2.185 CCU Fault Code 1330 ........................................................................................ 359
3.2.186 CCU Fault Code 1335 ........................................................................................ 361
3.2.187 CCU Fault Code 1331 ........................................................................................ 362
3.2.188 CCU Fault Code 1332 ........................................................................................ 363
3.2.189 CCU Fault Code 1333 ........................................................................................ 364
3.2.190 CCU Fault Code 1334 ........................................................................................ 365
3.2.191 CCU Fault Code 1336 ........................................................................................ 366
3.2.192 CCU Fault Code 1337 ........................................................................................ 367
3.2.193 CCU Fault Code 1338 ........................................................................................ 368
3.2.194 CCU Fault Code 1339 ........................................................................................ 369
3.2.195 CCU Fault Code 1340 ........................................................................................ 371
3.2.196 CCU Fault Code 1341 ........................................................................................ 373
3.2.197 CCU Fault Code 1342 ........................................................................................ 375
3.2.198 CCU Fault Code 1343 ........................................................................................ 377
3.2.199 CCU Fault Code 1344 ........................................................................................ 379
3.2.200 CCU Fault Code 1345 ........................................................................................ 381
3.2.201 CCU Fault Code 1346 ........................................................................................ 383
3.2.202 CCU Fault Code 1347 ........................................................................................ 385
3.2.203 CCU Fault Code 1348 ........................................................................................ 387
3.2.204 CCU Fault Code 1349 ........................................................................................ 389
3.2.205 CCU Fault Code 1350 ........................................................................................ 391
3.2.206 CCU Fault Code 1351 ........................................................................................ 393
3.2.207 CCU Fault Code 1352 ........................................................................................ 395
3.2.208 CCU Fault Code 1353 ........................................................................................ 397
3.2.209 CCU Fault Code 1354 ........................................................................................ 399
3.2.210 CCU Fault Code 1355 ........................................................................................ 401
3.2.211 CCU Fault Code 1356 ........................................................................................ 403
3.2.212 CCU Fault Code 1357 ........................................................................................ 405
3.2.213 CCU Fault Code 1358 ........................................................................................ 407
3.2.214 CCU Fault Code 1359 ........................................................................................ 409
3.2.215 CCU Fault Code 1360 ........................................................................................ 411
3.2.216 CCU Fault Code 1361 ........................................................................................ 413
3.2.217 CCU Fault Code 1362 ........................................................................................ 415
3.2.218 CCU Fault Code 1363 ........................................................................................ 417
3.2.219 CCU Fault Code 1364 ........................................................................................ 419
3.2.220 CCU Fault Code 1365 ........................................................................................ 421
3.2.221 CCU Fault Code 1366 ........................................................................................ 423
3.2.222 CCU Fault Code 1367 ........................................................................................ 425
3.2.223 CCU Fault Code 1368 ........................................................................................ 427
3.2.224 CCU Fault Code 1369 ........................................................................................ 429
3.2.225 CCU Fault Code 1370 ........................................................................................ 431
3.2.226 CCU Fault Code 1371 ........................................................................................ 433
3.2.227 CCU Fault Code 1372 ........................................................................................ 434
3.2.228 CCU Fault Code 1373 ........................................................................................ 435
3.2.229 CCU Fault Code 1374 ........................................................................................ 436
3.2.230 CCU Fault Code 1375 ........................................................................................ 437
3.2.231 CCU Fault Code 1376 ........................................................................................ 438
3.2.232 CCU Fault Code 1377 ........................................................................................ 439
3.2.233 CCU Fault Code 1378 ........................................................................................ 440
3.2.234 CCU Fault Code 1379 ........................................................................................ 441

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 7/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.235 CCU Fault Code 1380 ........................................................................................ 443
3.2.236 CCU Fault Code 1381 ........................................................................................ 445
3.2.237 CCU Fault Code 1382 ........................................................................................ 447
3.2.238 CCU Fault Code 1383 ........................................................................................ 449
3.2.239 CCU Fault Code 1384 ........................................................................................ 451
3.2.240 CCU Fault Code 1385 ........................................................................................ 453
3.2.241 CCU Fault Code 1386 ........................................................................................ 455
3.2.242 CCU Fault Code 1387 ........................................................................................ 457
3.2.243 CCU Fault Code 1388 ........................................................................................ 459
3.2.244 CCU Fault Code 1389 ........................................................................................ 461
3.2.245 CCU Fault Code 1390 ........................................................................................ 463
3.2.246 CCU Fault Code 1391 ........................................................................................ 465
3.2.247 CCU Fault Code 1392 ........................................................................................ 467
3.2.248 CCU Fault Code 1393 ........................................................................................ 469
3.2.249 CCU Fault Code 1394 ........................................................................................ 471
3.2.250 CCU Fault Code 1395 ........................................................................................ 473
3.2.251 CCU Fault Code 1396 ........................................................................................ 475
3.2.252 CCU Fault Code 1397 ........................................................................................ 477
3.2.253 CCU Fault Code 1398 ........................................................................................ 479
3.2.254 CCU Fault Code 1399 ........................................................................................ 481
3.2.255 CCU Fault Code 1400 ........................................................................................ 483
3.2.256 CCU Fault Code 1401 ........................................................................................ 485
3.2.257 CCU Fault Code 1402 ........................................................................................ 486
3.2.258 CCU Fault Code 1403 ........................................................................................ 488
3.2.259 CCU Fault Code 1404 ........................................................................................ 490
3.2.260 CCU Fault Code 1405 ........................................................................................ 492
3.2.261 CCU Fault Code 1406 ........................................................................................ 494
3.2.262 CCU Fault Code 1407 ........................................................................................ 496
3.2.263 CCU Fault Code 1408 ........................................................................................ 498
3.2.264 CCU Fault Code 1409 ........................................................................................ 500
3.2.265 CCU Fault Code 1410 ........................................................................................ 502
3.2.266 CCU Fault Code 1411 ........................................................................................ 505
3.2.267 CCU Fault Code 1412 ........................................................................................ 506
3.2.268 CCU Fault Code 1413 ........................................................................................ 507
3.2.269 CCU Fault Code 1414 ........................................................................................ 508
3.2.270 CCU Fault Code 1415 ........................................................................................ 509
3.2.271 CCU Fault Code 1416 ........................................................................................ 510
3.2.272 CCU Fault Code 1417 ........................................................................................ 511
3.2.273 CCU Fault Code 1418 ........................................................................................ 512
3.2.274 CCU Fault Code 1419 ........................................................................................ 513
3.2.275 CCU Fault Code 1420 ........................................................................................ 514
3.2.276 CCU Fault Code 1421 ........................................................................................ 515
3.2.277 CCU Fault Code 1422 ........................................................................................ 516
3.2.278 CCU Fault Code 1423 ........................................................................................ 517
3.2.279 CCU Fault Code 1424 ........................................................................................ 518
3.2.280 CCU Fault Code 1425 ........................................................................................ 519
3.2.281 CCU Fault Code 1426 ........................................................................................ 520
3.2.282 CCU Fault Code 1427 ........................................................................................ 521
3.2.283 CCU Fault Code 1428 ........................................................................................ 522
3.2.284 CCU Fault Code 1429 ........................................................................................ 523
3.2.285 CCU Fault Code 1430 ........................................................................................ 524
3.2.286 CCU Fault Code 1431 ........................................................................................ 525

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 8/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.287 CCU Fault Code 1432 ........................................................................................ 526
3.2.288 CCU Fault Code 1433 ........................................................................................ 527
3.2.289 CCU Fault Code 1434 ........................................................................................ 528
3.2.290 CCU Fault Code 1435 ........................................................................................ 529
3.2.291 CCU Fault Code 1436 ........................................................................................ 530
3.2.292 CCU Fault Code 1437 ........................................................................................ 531
3.2.293 CCU Fault Code 1438 ........................................................................................ 532
3.2.294 CCU Fault Code 1439 ........................................................................................ 533
3.2.295 CCU Fault Code 1440 ........................................................................................ 534
3.2.296 CCU Fault Code 1441 ........................................................................................ 535
3.2.297 CCU Fault Code 1442 ........................................................................................ 536
3.2.298 CCU Fault Code 1443 ........................................................................................ 537
3.2.299 CCU Fault Code 1444 ........................................................................................ 538
3.2.300 CCU Fault Code 1445 ........................................................................................ 539
3.2.301 CCU Fault Code 1446 ........................................................................................ 540
3.2.302 CCU Fault Code 1447 ........................................................................................ 541
3.2.303 CCU Fault Code 1449 ........................................................................................ 542
3.2.304 CCU Fault Code 1450 ........................................................................................ 543
3.2.305 CCU Fault Code 1451 ........................................................................................ 544
3.2.306 CCU Fault Code 1452 ........................................................................................ 545
3.2.307 CCU Fault Code 1453 ........................................................................................ 546
3.2.308 CCU Fault Code 1454 ........................................................................................ 547
3.2.309 CCU Fault Code 1455 ........................................................................................ 548
3.2.310 CCU Fault Code 1456 ........................................................................................ 549
3.2.311 CCU Fault Code 1457 ........................................................................................ 550
3.2.312 CCU Fault Code 1458 ........................................................................................ 552
3.2.313 CCU Fault Code 1459 ........................................................................................ 553
3.2.314 CCU Fault Code 1460 ........................................................................................ 555
3.2.315 CCU Fault Code 1940 ........................................................................................ 557
3.2.316 CCU Fault Code 1941 ........................................................................................ 557
3.2.317 CCU Fault Code 1942 ........................................................................................ 558
3.2.318 CCU Fault Code 1943 ........................................................................................ 559
3.2.319 CCU Fault Code 1944 ........................................................................................ 560
3.2.320 CCU Fault Code 1945 ........................................................................................ 562
3.2.321 CCU Fault Code 1946 ........................................................................................ 564
3.2.322 CCU Fault Code 1947 ........................................................................................ 566
3.2.323 CCU Fault Code 1948 ........................................................................................ 568
3.2.324 CCU Fault Code 1949 ........................................................................................ 569
3.2.325 CCU Fault Code 1950 ........................................................................................ 570
3.2.326 CCU Fault Code 2020 ........................................................................................ 571
3.2.327 CCU Fault Code 2021 ........................................................................................ 573
3.2.328 CCU Fault Code 2022 ........................................................................................ 575
3.2.329 CCU Fault Code 2050 ........................................................................................ 576
3.2.330 CCU Fault Code 2100 ........................................................................................ 577
3.2.331 CCU Fault Code 2101 ........................................................................................ 580
3.2.332 CCU Fault Code 2102 ........................................................................................ 582
3.2.333 CCU Fault Code 2103 ........................................................................................ 584
3.2.334 CCU Fault Code 2104 ........................................................................................ 587
3.2.335 CCU Fault Code 2105 ........................................................................................ 589

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 9/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
List of Figures
Figure 1 How to use the Trouble shooting guide ............................................................................................. 16
Figure 2 Example, overview I/O 12 ................................................................................................................. 18
Figure 3 Example, detailed view IO E121 ....................................................................................................... 18
Figure 4 List of triggered in Diagnostic messages .......................................................................................... 19
Figure 5 Locomotive control system overview of WAG9 ................................................................................. 22
Figure 6 Locomotive control system overview of WAG9_Upgrade and WAP7_Upgrade ............................... 23
Figure 7 Ethernet architecture and configuration ............................................................................................ 24
Figure 8 MVB architecture and configuration .................................................................................................. 25
Figure 9 Lutze Disposition ............................................................................................................................... 27

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 10/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
List of Tables
Table 1 Technical Data .................................................................................................................................... 21
Table 2 VCU Layout ........................................................................................................................................ 25
Table 3 VCU Architecture ................................................................................................................................ 26

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 11/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
0 Introduction
0.1 General information about this document
• This Trouble Shooting Guide (TSG) is for maintenance personnel, who are trained in
the general handling of the locomotive, traction equipment and locomotive control
equipment.
• The trouble shooting personnel should already be familiar with the specific safety
measures required on these locomotives due to the presence of the various high-
voltage capacitors. For a detailed description the personnel has to refer to the safety
precautions for the locomotive it is working on!
• This trouble shooting guide provides information about the diagnostic messages
(fault codes) in the Central Control Units diagnostic memory.

In order to understand the TSG, the user must be familiar with the documents listed below
in section 0.2.

Section 1 contains an overview, how to read the trouble shooting guide.


In addition to each individual diagnostic code in section 3, there is also a description of the possible
causes and corrective measures.

0.2 Other applicable documents


Reference Document Version Date
[SyArs] System architecture WAG9_WAP7_7MW
SAP : A6Z00042973571
[IO_assign] Revised-Lion-Assignment_EN2_2
[WAG9_Schem] WAG9_9K_UPGRADE SCHEMATIC_A2

0.3 Safety instructions and notes


All safety instructions in the maintenance manuals of the relevant components must be observed
when performing tasks described in this document, safety precautions are not explicitly stated in this
document.

As general, at least the following five safety regulations have to be considered:


- Disconnect mains!
- Prevent reconnection!
- Test for absence of harmful voltages!
- Ground and short circuits!
- Cover or close of nearby live parts!

When performing troubleshooting on the vehicle, the relevant sections of the running maintenance
manual for the affected component/system and especially their Safety Summary must be
observed.

Also following must be considered:


- Even if a converter container has been switched off for a prolonged period of time, residual
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 12/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
charge can pose enough of a danger to cause serious personal injury.
- Personnel will be exposed to the same risks when working on the traction components
connected to the converter container and their supply lines (e.g. pantograph, main circuit
breaker, and all connecting lines).
- It can take more than one hour for the capacitors to discharge. Therefore, even after a long
wait time has elapsed, personnel have to make sure that the capacitors are actually
discharged and de-energized.
- Capacitors which are not short-circuited appropriately will continue to absorb power even
when disconnected. Accordingly, when capacitors are replaced, their connectors must be
short-circuited appropriately (and this shorting must, of course, be reversed once the new
capacitors have been installed and connected).
- If the converter container has to be opened for the purpose of accessing the TCU, the
same safety regulations shall apply as when working on the converter.
- When wiring interfaces to external destinations “on the fly”, extreme caution must always be
taken when laying cables so that there is always sufficient safety clearance between them
and live parts.
- Connectors must be attached as appropriate for their design (snapped or screwed into
place).
- Personnel are required to comply with all safety information in this document, as well as
that appearing on devices and vehicles.
- Only manufacturer’s original spare parts or parts recommended by the manufacturer are to
be used.
- All maintenance operations or repairs must comply with the necessary maintenance
intervals and repair and replacement guidelines.

DANGER
Only tools and auxiliaries to be used that are approved for carrying out work on and in the con-
verter container. This requirement applies to all cables temporarily or permanently connected to
the DSP. Connecting cables between the DSP and the PC or measuring devices must meet
specific requirements; therefore, only tools approved by Siemens may be used.
Noncompliance with warning notices and failure to take safety precautions can lead to fatal injuries
and serious material damage.

0.4 List of abbreviations


Abbreviation Meaning

4QC Four-quadrant chopper


AC Alternating Current
AI Analog input
AO Analog output
Approx. Approximately
ATC Automatic Train Control
Aux. Auxilliary
BC Brake Cylinder
BCU Brake Control Unit
BP Break Pipe
BRAM Battery buffered random access memory (RAM) of the SIBAS 32 control
Units
BUR Auxiliary converter control
CAN Controller Area Network
CB Circuit Breaker
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 13/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
CCU Central Control Unit
Circ. Circuit
CPU Central Processing Unit
Ctrl Control
DC Diagnostic Code also called „Diagnostic Message“ or “Fault Code”
DI Digital input
Diag. Diagnostic
DO Digital output
DSP Digital Signal Processor
e.g. for example
GND Ground
HEP Head end power
HW Hardware
I/O Input/Output
ICU Inverter control unit
IN Signal Input
LED Light Emitting Diode
LION External Input/output=I/O
MCB Main circuit breaker
MR Main Reservoir
MVB Multifunction Vehicle Bus
No. Number
NSDB Node Supervisor database
OUT Signal Output
Panto Pantograph
Pos. Position
PR Program
PWI Pulse Width Inverter
RDA Remote Data Access
RS232 Standard for serial computer interfaces with ±12V signals (V.24)
SIBAS 32 Siemens Bahn Automatisierungs System – Siemens automation system
for railway applications
Sig Signal
SW Software
TC Traction converter
TCC Traction converter cubical
TCN Train Communication Network
TCU Traction Control Unit
TSG Trouble shooting guide
VCB Vacuum circuit breaker
VCU Vehicle control unit
WTB Wired train bus

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 14/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
1 How to use the trouble shooting guide
This document assumes, that service personnel has retrieved the necessary information from the
CCU diagnostic memory and is analyzing it either:
• offline via Sibas Diagnosis Viewer or
• online via SIBAS-Monitor

The list of all possible CCU diagnostic codes can be found in section 3.2. Typical reactions of the
control system, which are repeatedly used, are defined in section 2.3.1.

Further information about the desired behavior and the functionalities of each system can be found
in:
- Related System Architecture Specifications [SyArs] of each system included in the
technical documentation
- Technical documentation, WAG9 Schematic [WAG9_Schem].
Strategy:
If more than one Diagnostic message is triggered, start working on the messages that are related
to faults or the status of:
- Circuit Breakers
- Contactors / Relays
- I/O-Stations
Solving these diagnostic messages could lead to dissolve further messages.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 15/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
1.1 Schematic example

How to use the trouble shooting guide

Read diagnostics

Is a diagnostics code available? No

Yes No action required

Are there
any diagnostic codes that occur often? No
(more than twice)

Yes Check whether the message can be


ignored if it appears sporadically.
Otherwise, troubleshooting as per
Troubleshooting as per Chapter 3 Chapter 3

End

Figure 1 How to use the Trouble shooting guide

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 16/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
1.2 Using Circuit diagrams
The circuit diagrams are included in the technical documentation, section “WAG9 Schematic
[WAG9_Schem]”. Each electrical device on the loco and also each electrical Input/output of any
Lütze I/O module can be found in that circuit diagrams.

To find an electrical device its “Device Designation” has to be used. Device Designations are used
within the schematics in section 3 of this TSG.

A Device Designation is based on the standard 6k nomenclature and not on the SIEMENS
standards. Few examples have been stated below:

CCU1: 127.1/1
Auxiliary Compressor: 48.1
Battery: 111

This Device Designations can be used with the normal Search function of a PDF viewer software.
See also technical documentation, section WAG9 Schematic [WAG9_Schem]

To find a specific electrical Input or Output signal on a Lütze module, it is also possible to use the
search function of the PDF viewer software. Refer WAG9 IO assignment [IO_assign] for the IO
nomenclature e.g.:
- E111_03 Binary Input
- A113_03 Binary Output
- EA112_00 Analogue Input
- AA115_01 Analogue Output

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 17/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
1.3 How to check the status of I/Os
Status of each Lütze contact can be checked easily via Service screen TOD.
In menu “Service” / “I/O signals” all inputs and outputs are listed.

Figure 2 Example, overview I/O 12

Figure 3 Example, detailed view IO E121

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 18/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Also, each Lütze contact can be checked via Sibas Monitor. Therefore, Sibas Monitor has to be
started and connected to CCU. Then the command “Applic. Connect.” has to be used.

Examples:
To check binary input E111_00 Applic. -> Connect. -> EXT11_20.O00
To check binary output A116_00: Applic. -> Connect. -> PACKA116.I00
To check analogue input EA213_00: Applic. -> Connect. -> E213_00.OUT
To check analogue output AA217_00: Applic. -> Connect -> SA217_00.IN

1.4 How to check, if a diagnostic message is still triggered


Checking if a diagnostic message is still active can be done online, without again reading out
Expert2-files.

Possibility 1, via Sibas Monitor:


Therefore, Sibas Monitor has to be started and connected to CCU.
Via menu “Events” / “Statistics_D”, the list of triggered Diagnostic messages can be displayed.
Each code that was active when the list was called is marked with an asterisk “*”.

Figure 4 List of triggered in Diagnostic messages

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 19/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
2 Trouble shooting guide
2.1 Locomotive Overview
The purpose of this section is to provide several schematic diagrams to make the TSG easier to
understand. The following schematics and charts are included.
- WAG 9 Technical Data
- Locomotive control system overview
- Ethernet configuration
- MVB configuration
- Overview VCU
- Overview I/O Stations

WAG9 Technical Data

Axle arrangement Co-Co

Gear ratio 1:5.133


Gauge 1676 mm
Wheel diameter new 1092 mm
half worn 1054 mm
worn 1016 mm
Maximum permitted difference of wheel 8 mm
Diameters within one bogie
Maximum permitted difference of wheel 25 mm
diameters between bogies
Sharpest negotiable curve radius 174 m
Total weight (without ballst) 123 t
Catenary voltage Nominal 25 kV
Minimum 19 kV
Maximum 27.5 kV
Frequency 50 Hz +/- 8%
Static power supply to auxiliary circuits
Voltage 415 V +/- 10%
Frequency 0 … 50 Hz
Battery voltage 110 VDC
Regenerative brake Maximum braking force 260 kN
Automatic train brake Maximum braking force 242 kN
Coefficient of adhesion
35%
Parking brake Maximum braking force 37 kN
Continuous rating on wheel rim between 4500 kW
80 and 120 km/h
Traction force on wheel rim between 0
and 50 km/h
maximum 460 kN

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 20/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
continuous 325 kN
Maximum speed with half worn wheels 100 km/h
at constant speed 100 km/
Maximum ambient temperatures in the sun 75 °C
In the shade 55 °C
Minimum ambient temperature 0 °C
Table 1 Technical Data

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:

and WAP7x CCU B 2020-12-03 EN 21/590


Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Date: 25.09.2017 System Architecture WAG9
WTB Trainbus (via UIC)

Traction
Cab 2 Converter 1 Cab 1
TCN GW
Traction
Converter 2
CCU 2 CCU 1

Service Service
Interface Interface
TC2 TC1
TCU 2 TCU 1
HW HW
Display Cab Display Cab
2 1

Ethernet Ethernet
MVB

Aux.Conv. Aux.Conv.
Box 2 Box 1
VCU1 VCU2
Aux. Inv. Aux. Inv.
2 Control 1
I/O 11 Electronics I/O 21
Aux. Inv. pneumatic
3 manifold
I/O 12 I/O 22

Battery
Charger

Vigilance
Control
Equipment

Trafo

Auxiliary (incl.
Control elements
machine room) High Voltage
System
(Panto, VCB, ...)
Brake /
Pneumatic
TM 4/5/6 +110V TM 1/2/3

Brake Pipe

Figure 5 Locomotive control system overview of WAG9

Reference designation: Index: Date:2020-12-03 Language: Pages:


-TS_RGC07&EDC023
Trouble shooting guide WAG9x and WAP7x CCU B EN 22/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All
rights created by patent grant or registration of a utility model or design patent are reserved.
Date: 20.02.2018 System Architecture WAG9_Upgrade & WAP7_Upgrade
WTB Trainbus (via UIC)

Traction Traction
Cab 2 Converter 2 Converter 1 Cab 1
TCN GW

CCU 2 CCU 1
ACU2 ACU1
HW HW
Service Service
Interface Interface
TC2 TC1
TCU 2 TCU 1
HW HW
Display Cab Display Cab
2 1

Ethernet Ethernet
MVB

Aux/HEP
VCU1 VCU2 Cubicle
Battery
I/O 11 I/O 21
Control Charger
Electronics
I/O 12 pneumatic I/O 22
manifold

Event
RDS
Recorder

Vigilance
Control
Equipment

Trafo

Auxiliary (incl.
Control elements
machine room) High Voltage
System
(Panto, VCB, ...)
Brake /
Pneumatic
TM 4/5/6 +110V TM 1/2/3

Brake Pipe

Figure 6 Locomotive control system overview of WAG9_Upgrade and WAP7_Upgrade

Reference designation: Index: Date:2020-12-03 Language: Pages:


-TS_RGC07&EDC023
Trouble shooting guide WAG9x and WAP7x CCU B EN 23/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All
rights created by patent grant or registration of a utility model or design patent are reserved.
CCU1
Display1

Ethernet
Service TCU1
Switch 1
Interface

Cab1 ICUs
ICUs
ICUs
VCU1
ICUs
ICUs
Cabinet
Ethernet
Traction Converter 1
Switch 3

Display2 CCU2

Service Ethernet Ethernet


TCU2
Interface Switch 2

Cab2
ICUs
ICUs
ICUs
ICUs
ICUs

Aux Traction Converter 2

Inv2

Aux Aux
Inv3 Inv1

Auxiliary Converter 2 Auxiliary Converter 1

Figure 7 Ethernet architecture and configuration

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 24/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
To WTB

TCN
HW Signals
Inputs / Outputs GW
ACU1
CCU1
Aux.Conv. 1

HW Signals TCU1
Inputs / Outputs
IO 11 CAN
HW Signals
Inputs / Outputs
ICUs
IO 12
Traction Converter 1
VCU1 Cabinet
BCU
MVB
HW Signals
Inputs / Outputs ACU2
IO 21
HW Signals
Inputs / Outputs
ACU3
IO 22
Aux.Conv. 2
VCU2 Cabinet

CCU2
Display1

Cab1 TCU2

CAN
HW Signals
Inputs / Outputs
Display2 ICUs

Cab2 Traction Converter 2

Figure 8 MVB architecture and configuration

2.1.1 VCU Layout

VCU Device Location


CCU1 Traction Converter 1
TCN-GW Traction Converter 1
VCU1
IO11 VCU1 box
IO12 VCU1 box
CCU2 Traction Converter 2
VCU2 IO21 VCU2 box
IO22 VCU2 box
Table 2 VCU Layout

A detailed description of each module will be given in the technical documentation.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 25/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Power Supply 110V DC Switch for Switch for
MCU TCN Gateway
Ethernet MVB WTB Power Supply 110V DC
via CB 127.1/1 Power Supply 110V DC
via CB 127.11/1 MVB
Power Supply 110V DC via CB 127.9/2
via CB 127.9/1 - +
+
Traction Converter 1 Compartment VCU1
- 110V + Power Supply - Sibas 32C MCU2 #ZSG - 110V
110V / 24V
- 2x IO Stations
- Sibas 32 TCN GW - CB 127.9/1 Power Supply
Power Supply - Sibas 32C MCU2 #ASG 411.AJ/A1 - /A1 Power Supply
110V / 24V
411.JA/15 - /8
+
411.JD/15 - /8 - +
411.LA/15 - /8
24V 411.LD/15 - /8
-
- CB 127.9/2
Bus I/O I/O I/O Bus I/O I/O I/O
BPL04 TCN BPL05 BPL01 411.CJ/A1 - /A2
coupler module module module coupler module module module
8TE 8TE 64TE 411.OA/15 - /8
=> 5V / +- 15V 411.OD/15 - /8

CI - (Optional)
411.QA/15 - /8
Incl. SV 24V

MCU 2 MCU 2 ICU 1 ICU 1 ICU 1 ICU 1 ICU 1


TCN IO

411.QD/15 - /8

EXT 1
Spare TCN 6U Gateway
1xETH 6FH9415-3K 1xETH AUX PWI PWI PWI 4QC IO 11 IO 12
1xMVB 1xMVB (Optional)

#5 #4 #3 #2 #1
CCU-Rack, Width 84TE
(8TE Sibas 32C,
8TE Sibas 32 TCN Gateway
And 64TE TCU)
Incl. fan, therefore 84TE! Fan Subassembly 84TE (with Buffer Battery)

Power Supply 110V DC Switch for Ethernet MVB Power Supply 110V DC
via CB 127.1/2 MCU Power Supply 110V DC
via CB 127.11/2 MVB
Power Supply 110V DC via CB 127.9/4
via CB127.9/3 - +
+
Traction Converter 2 Compartment VCU2
- 110V + Power Supply - Sibas 32C MCU2 #ZSG - 110V
110V / 24V - Sibas 32C MCU2 #ASG - CB 127.9/3 - 2x IO Stations
412.AJ/A1 - /A1 Power Supply
Power Supply
412.JA/15 - /8 Power Supply
110V / 24V
412.JD/15 - /8
+ 412.LA/15 - /8 - +
412.LD/15 - /8
24V

-
- CB 127.9/4
Bus I/O I/O I/O Bus I/O I/O I/O
BPL04 TCN BPL05 BPL01 412.CJ/A1 - /A2
coupler module module module coupler module module module
8TE 8TE 64TE 412.OA/15 - /8
412.OD/15 - /8
CI – (Optional)

412.QA/15 - /8
(Empty Slot)

MCU 2 MCU 2 ICU 1 ICU 1 ICU 1 ICU 1 ICU 1


412.QD/15 - /8
EXT 1

Spare
1xETH (Empty Slot) 1xETH AUX PWI PWI PWI 4QC IO 21 IO 22
1xMVB 1xMVB (Optional)

#5 #4 #3 #2 #1
CCU-Rack, Width 84TE
(8TE Sibas 32C,
8TE Sibas 32 TCN Gateway
And 64TE TCU)
Incl. fan, therefore 84TE! Fan Subassembly 84TE (with Buffer Battery)

Table 3 VCU Architecture

2.1.2 IO Station

The four IO stations provide digital and analogue inputs and outputs for the CCUs. In each VCU
box there are two IO stations installed (see Figure 8). Communication between IOs and CCUs is
realized via MVB.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 26/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
LION Station 11
DE AE DA DA AA RA
16xDC110V 4x0..10V DC 8xDC24V 8xDC110V 4x±10V 8xDC110V

PS 11 BC 11

LION Station 12
DE DE DE DA DA RA
16xDC110V 16xDC110V 16xDC110V 8xDC24V 8xDC110V 8xDC110V

PS 12 BC 12

LION Station 21
DE DE AE DA DA RA AA
16xDC110V 16xDC110V 4x0..10V DC 8xDC24V 8xDC110V 8xDC110V 4x±10V

PS 21 BC 21

LION Station 22
DE DE DE DA RA DA
16xDC110V 16xDC110V 16xDC110V 8xDC24V 8xDC110V 8xDC110V

PS 22 BC 22

Figure 9 Lutze Disposition

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 27/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
2.2 Structure of the troubleshooting guide
Description of the structure of the troubleshooting instructions relating to the fault code.
• Fault code number
• Message text
• Applicable variants
o Checked – Applicable to the locomotive variant
o Unchecked – Not applicable to the locomotive variant
• Troubleshooting
o Steps to take for troubleshooting, specifically for the particular fault code.
• Device name (Device name) of the components concerned
o List of the components concerned. However, the list is only meant as an initial step.
There is no complete list of all possible components involved.
• Condition
o If the FC can only be entered under certain conditions, for example while booting
up, during voltage retention, while braking, etc.
• Criteria
o What is the cause for the fault code?
• Reaction
o Protective reaction
• Related messages
o Are there any messages that often occur at the same time or that might help in
troubleshooting?

2.3 Definitions
Cab activated:
The reverser in the active cab is in position Neutral, Forward or Reverse and no other cab in the train
was already activated.

2.3.1 Typical reactions of the control unit (CCU/TCU)

“Monitor-only” operation mode:


A mode of the SIBAS CPU units (mounting position C019 in CCU/TCU) in which the cyclical
processing of the application software is stopped. The control unit is brought to a safe state, all
outputs controlled by this control unit are opened. Only software functions for communication with
the Service-PC are still active.

That operation mode is visualized by a blank 7-segment-display on the CPU unit. Also, the red LED
directly below the 7-segment-display is not illuminated.

Once the reason is cleared the control unit can be put back into “Normal” operation mode via the
Service-PC or a hardware reset (battery off/on or reset button on SIBAS front panel).
`

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 28/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3 Trouble shooting guide
3.1 Cross reference from crew messages to diagnostic messages
CCU diagnostic
Crew message message
0012 Panto 1 - Lowering fault 0243
0013 Panto 2 - Lowering fault 0244
0016 Panto 1 - Raising fault 0239
0017 Panto 2 - Raising fault 0240
0020 Panto 1 lowered automatically 0255
0021 Panto 2 lowered automatically 0256
0023 VCB control loop test failed - VCB locked 0403,0404,0406,0407
0024 abort VCB loop test: conditions missing 0400
0030 VCB loop failure by TCU 1 0421
0031 VCB loop failure by TCU 2 0422
0032 CB for VCB loop is tripped (127.12) 0423
0048 VCB switch on fault 0280
0049 VCB switch off fault - VCB locked 0281
0054 VCB serious fault - VCB locked 0287
0080 Analog value acquisition fault TCU 1 or TCU 2 0348,0375
0081 Catenary voltage not stable - VCB lock for 1 min 0343
0083 Catenary overvoltage - VCB off 0340
0085 Catenary undervoltage - VCB off 0342
0086 Continued catenary overvoltage - VCB lock for 2min 0351
0090 Catenary current monitoring - VCB off 0367
0091 No-load current monit. - VCB off 0384
0092 Current monitoring - VCB locked 0364
0102 Transformer oil pressure - VCB off 1940
0105 Transformer overtemperature - VCB locked 1944,1942,1941
0158 Parking brake release failed 1158
0159 Parking brake apply failed 1159
0162 Fault in brake electronics 1162
262 TC1 water pressure fault 0532,0533
0263 TC 1 coolant level low (Warning) 0534
0264 TC1 coolant level low (Alarm) - Leakage 0535
266 TC1 inside air temperature sensor faulty 0536
0269 TC1 cooling blower failed 0530
0270 TC1 water pressure fault 0531
0271 BG 1 TM blower failed 0545
0280 Tractive effort without demand at bogie 1 0491,0492,0493
0310 TC 2 coolant level low (Warning) 0541
0311 TC2 coolant level low (Alarm) - Leakage 0542

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 29/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
CCU diagnostic
Crew message message
0313 TC2 inside air temperature sensor faulty 0543
0316 TC2 water pressure fault 0539,0540
0317 TC2 cooling blower failed 0537
0318 TC2 water pressure fault 0538
0319 BG 2 TM blower failed 0546
0328 Tractive effort without demand at bogie 2 0494,0495,0496
0368 Traction release fault (AGT) 0520,0521,0500
0369 Auxiliary fuse Open 0570
0377 Auxiliary converter over current detected 0631
0561 Harmonic Filter - Contact 8.2 stuck open 0870
0562 Harmonic Filter - Contact 8.2 stuck closed 0871
0563 Harmonic Filter: Contact 8.1 stuck open 0872
0564 Harmonic Filter: Contact 8.1 stuck closed 0873
0565 Harmonic Filter: Contact 8.41 stuck open 0874
0566 Harmonic Filter: Contact 8.41 stuck closed 0875
0567 Harmonic Filter: Inrush current too high 0876
0568 Harmonic Filter : Overcurrent 0877
0569 Harmonic filter contactor test failed 0878
0635 Comm. error with multiple Ext.IO modules. 2103
0687 Software version conflict, Traction block 0505
0688 Software version conflict, Traction block override 0506
0700 Safety Relay (126.6) failed 0430
0704 HW-configuration conflict 0049
0707 BRAM Error - Wheel diameter 0947
0710 Actual CDS speed invalid 0931
0712 Mileage invalid 0934
0714 Fault - Calculation wheel diameter 0933
0755 Smoke detected in machine room 2101
0756 Fire Detection Equipment (212) faulty 2100
0757 Fire detected in machine room 2102
0762 Fire Detected in Slave Loco 2105
0824 Gateway comm. error or gateway off 2020
0825 WTB communication error 2021,2022
0900 TCU 1 communication error 0060
0902 Communication error ACU 1 0062
0903 Communication error ACU 2 0063
0904 Communication error ACU 3 0064
0932 MEMOTEL device faulty 2104

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 30/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2 Diagnostic messages
3.2.1 CCU Fault Code 0004

PMEM: error write buffer


Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 0004

Replace Buffer

End

Components concerned:
Component Device name CCU1 Device name CCU2
- -

Condition:
-

Criteria:
- Write buffer is initialized.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 31/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.2 CCU Fault Code 0005

PMEM: error user data length (read buffer)


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 0005

Replace Buffer

End

Components concerned:
Component Device name CCU1 Device name CCU2
- -

Condition:
-

Criteria:
- Buffers are not empty.
- Service buffer initialization ok.
- Buffer length and size are not equal.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 32/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.3 CCU Fault Code 0006

PMEM: error checksum (read buffer)


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 0006

Replace Buffer or check CRC and


its length.

End

Components concerned:
Component Device name CCU1 Device name CCU2
- - -

Condition:
-

Criteria:
- Buffers are not empty.
- Service buffers initialization ok.
- CRC checksum not valid or CRC length and buffer length not equal.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 33/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.4 CCU Fault Code 0007

PMEM: error user data length (write buffer)


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 0007

Replace Buffer

End

Components concerned:
Component Device name CCU1 Device name CCU2
- - -

Condition:
-

Criteria:
- Service buffers initialization not ok.
- User data length and buffer size do not matches.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 34/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.5 CCU Fault Code 0008

PMEM: error checksum (write buffer)


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 0008

Replace Buffer

End

Components concerned:
Component Device name CCU1 Device name CCU2
- - -

Condition:
-

Criteria:
- Service buffers initialization not ok.
- CRC checksum not valid or CRC length and buffer length not equal.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 35/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.6 CCU Fault Code 0009
PMEM: service buffer initialization not ok
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 0009

Replace Buffer

End

Components concerned:
Component Device name CCU1 Device name CCU2
- - -

Condition:
-

Criteria:
- Initialization of Read buffer or write buffer or service buffer is not ok.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 36/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.7 CCU Fault Code 0049
Locomotive variant invalid, check variant settings.
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0049

Check connection of pins in IO


station 12(E123_12, E123_13,
E123_14, E123_15).
Set correct variant.

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O-Station 12 - -

Condition:
- MVB communication with I/O 12 is ok

Criteria:
- Hardware variant and software variant are equal.
- OR Hardwared variant changed from IO station 12(E123_12, E123_13, E123_14, E123_15)

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 37/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.8 CCU Fault Code 0060
Communication error TCU 1
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 38/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0060

Check / reload NSDB


in CCU and TCU1.

Diagnostic code
Yes
still active?

Further
codes regarding MVB
No
communication
triggered?
No
CCU:
Additional codes
No
regarding TCU1
triggered?
Yes
Any
codes triggered
in TCU1 regarding MVB
communication or internal
Yes components?
Follow instructions of
No
these additional codes.

Follow instructions Yes


of these additional
codes.

Follow instructions
of these additional
codes.

Exchange CPU
module

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU1 415/1 415/1

Condition:
- Loco variant is WAG9 H 7MW, WAP7 Upgrade so loco has internal AUX.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 39/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Criteria:
- Receiving port error.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 40/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.9 CCU Fault Code 0061
Communication error TCU 2

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 41/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0061

Check / reload NSDB


in CCU and TCU2.

Diagnostic code
Yes
still active?

Further
codes regarding MVB
No
communication
triggered?
No
CCU:
Additional codes
No
regarding TCU2
triggered?
Yes
Any
codes triggered
in TCU2 regarding MVB
communication or internal
Yes components?
Follow instructions of
No
these additional codes.

Follow instructions Yes


of these additional
codes.

Follow instructions
of these additional
codes.

Exchange CPU
module

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU2 415/2 415/2

Condition:
- Loco variant is WAG9 H 7MW, WAP7 Upgrade so loco has internal AUX.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 42/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Criteria:
- Receiving port error.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 43/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.10 CCU Fault Code 0062
Communication error ACU 1

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0062

Check connection of pins in IO


station 12(E123_12, E123_13,
E123_14, E123_15).
Set correct variant.

Fault gone? Yes

No

Check ACU1 module.

Module Ok? Replace the Module

Yes

Check CB 127.22/1 and wiring


connections between CB and
ACU. If necessary replace the CB
or wiring

End

Components concerned:
Component Device name CCU1 Device name CCU2
ACU1 426/1 426/1

Condition:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 44/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Criteria:
- Loco variant is other than WAG9 H 7MW, WAP7 Upgrade.
- ACU1 communication is not ok.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 45/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.11 CCU Fault Code 0063
Communication error ACU 2

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0063

Check connection of pins in IO


station 12(E123_12, E123_13,
E123_14, E123_15).
Set correct variant.

Fault gone? Yes

No

Check ACU2 module.

Module Ok? Replace the Module

Yes

Check CB 127.22/2 and wiring


connections between CB and
ACU. If necessary replace the CB
or wiring

End

Components concerned:
Component Device name CCU1 Device name CCU2
ACU2 426/2 426/2

Condition:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 46/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Criteria:
- Loco variant is other than WAG9 H 7MW, WAP7 Upgrade.
- ACU2 communication is not ok.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 47/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.12 CCU Fault Code 0064
Communication error ACU 3

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0064

Check connection of pins in IO


station 12(E123_12, E123_13,
E123_14, E123_15).
Set correct variant.

Fault gone? Yes

No

Check ACU3 module.

Module Ok? Replace the Module

Yes

Check CB 127.22/3 and wiring


connections between CB and
ACU. If necessary replace the CB
or wiring

End

Components concerned:
Component Device name CCU1 Device name CCU2
ACU3 426/3 426/3

Condition:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 48/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Criteria:
- Loco variant is other than WAG9 H 7MW, WAP7 Upgrade.
- ACU3 communication is not ok.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 49/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.13 CCU Fault Code 0065
Communication error Display 1

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 65

Check connections of display.

Connections OK? No

Yes

Repair/replace Adjust connections of


display. display.

End

Components concerned:
Component Device name CCU1 Device name CCU2
Display 435/1 435/1

Condition:
-

Criteria:
- Communication with display is not ok.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 50/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.14 CCU Fault Code 0066
Communication error Display 2

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 66

Check connections of display.

Connections OK? No

Yes

Repair/replace Adjust connections of


display. display.

End

Components concerned:
Component Device name CCU1 Device name CCU2
Display 435/2 435/2

Condition:
-

Criteria:
- Communication with display is not ok.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 51/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.15 CCU Fault Code 0067
Communication error CCUS

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0067

Check / reload NSDB


in CCU1 and CCU2.

Diagnostic code
Yes
still active?

Also codes for MVB


communication triggered No
in CCU Master?

Other
codes regarding MVB
No communication triggered No
in CCU Slave or
Yes Master?

Yes

Follow instructions of Follow instructions of


Exchange CPU
these additional these additional
module
codes. codes.

End

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 52/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Criteria:
- Communication with display is not ok.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 53/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.16 CCU Fault Code 0239
Panto 1: Raising fault (no pressure feedback)

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2
Front Pantograph 1/1 1/1
Pressure Switch 130.4/1 130.4/1
I/O-Station 22 E222 E222_00
E225 E225
I/O-Station 21 E212 E212

Condition:
- CB I/O station signals (127.9) is on.
- Pantograph not cut out by cock
- Auxiliary air supply ok

Criteria:
- Front pantograph was not lifted within 15s after EP coil was energized.

Reaction:
- Fault code triggered
- VCB off
- All pantographs of vehicle lowered
- Lifiting pantographs inhibited

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 54/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.17 CCU Fault Code 0240
Panto 2: Raising fault (no pressure feedback)

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 55/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0240

Try to lift front pantograph


by pushbutton.

Message still
triggered?

Yes

Was pantograph Did


lifted completely and No pantograph even Yes
lowered again? try to lift?

Yes No

Check auxiliary air


Check operation of panto1 EP supply for pantograph
Valve (Somewhere a
Check operation of 130/1 leakage?)
pressure switch Check associated wiring to IO
No
130.4/2 (see circuit module A216 pin 214
diagram 05A). (see circuit diagram 05A)
If necessary replace EP Valve.
f necessary replace
pressure switch or
whole panel.

End

Components concerned:
Component Device name CCU1 Device name CCU2
Rear Pantograph 1/2 1/2
Pressure Switch 130.4/2 130.4/2
I/O-Station 22 E211 E211
E222 E222
I/O-Station 21 E216 E216
E212 E212

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 56/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- CB I/O station signals (127.9) is on.
- Pantograph not cut out by cock
- Auxiliary air supply ok

Criteria:
Rear pantograph was not lifted within 15s after EP coil was energized.

Reaction:
- Fault code triggered
- VCB off
- All pantographs of vehicle lowered
- Lifiting pantographs inhibited

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 57/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.18 CCU Fault Code 0243

Panto 1: Lowering fault (error in active pressure feedback)


Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 58/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 0243

Try to lower front


pantograph by pushbutton.

Message still
triggered?

Yes

Pantograph
No
lowered?

Yes Check operation of Panto1 EP


Valve 130/1
Check associated wiring to IO
Check operation of
module A225
pressure switch
(see circuit diagram 05A)
130.4/1 (see circuit
If necessary replace EP Valve.
diagram 05A).

Contact
130.4/1.Q2 pin 2
must be at level 72V DC.
Yes Fault corrected?
If necessary replace
No pressure switch or whole No
panel.
Check operation of IO
module E225.
If necessary replace
Fault corrected? Yes IO module.

No

Check associated
wiring to IO module
E222_00 (see circuit
diagram 05A).

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 59/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
Front Pantograph 1/1 1/1
Pressure Switch 130.4/1 130.4/1
I/O-Station 22 E222 E222
E225 E225

I/O-Station 21 E216 E216

Condition:
- CB I/O station signals (127.9) is on.
- Pantograph not cut out by cock
- Auxiliary air supply ok

Criteria:
Front pantograph was not lowered within 15s after EP valve was deenergized.

Reaction:
- Fault code triggered
- VCB off
- All pantographs of vehicle lowered
- Lifiting pantographs inhibited

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 60/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.19 CCU Fault Code 0244

Panto 2: Lowering fault (error in active pressure feedback)


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 61/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0244

Try to lower rear


pantograph by pushbutton.

Message still
triggered?

Yes

Pantograph
No
lowered?

Yes Check operation of Panto2 EP


Valve 130/1
Check associated wiring to IO
Check operation of E216
pressure switch 130.1/2 (see circuit diagram 05A)
(see circuit diagram 05A). If necessary replace EP Valve.

Contact
130.4/2.Q2, pin 2
must be at level 72V DC.
Yes Fault corrected?
If necessary replace
pressure switch or whole
No No
panel.
Check operation of IO
module E216.
If necessary replace
Fault corrected? Yes IO module.

No

Check associated
wiring to IO module
E211.05(see circuit
diagram 05A).

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 62/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
Rear Pantograph 1/2 1/2
Pressure Switch 130.4/2 130.4/2
I/O-Station 22 E225 E225
I/O-Station 21 E216 E216

Condition:
- CB I/O station signals (127.9) is on.
- Pantograph not cut out by cock
- Auxiliary air supply ok

Criteria:
Rear pantograph was not lowered within 15s after EP valve was deenergized.

Reaction:
- Fault code triggered
- VCB off
- All pantographs of vehicle lowered
- Lifiting pantographs inhibited

Related messages:
-

3.2.20 CCU Fault Code 0255

Panto 1: Sudden pressure loss


Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 63/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 0255

Check auxiliary air supply


for pantograph
(Somewhere a leakage?).

Fault corrected? Yes

No

Check operation of pressure switch


130.4/1
(see circuit diagram 05A).

Contact 130.4/1.Q2, pin 2


must be at level 0V DC when
pantograph lifted.
If necessary replace pressure switch .

Fault corrected? Yes

No

Check operation of Panto1 EP


Valve
130/1
Check associated wiring to IO
module 225
(see circuit diagram 05A)
If necessary replace Ep Valve.

End

Components concerned:
Component Device name CCU1 Device name CCU2
Front Pantograph 1/1 1/1
Pressure Switch 130.4/1 130.4/1
I/O-Station 22 E222 E222

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 64/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- CB I/O station signals (127.9) is on
- Pantograph not cut out by cock
- Auxiliary air supply ok

Criteria:
Front pantograph lowered without command automatically as Pressure Present becomes zero.

Reaction:
- Fault code triggered
- VCB off
- All pantographs of vehicle lowered
- Lifiting pantographs inhibited

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 65/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.21 CCU Fault Code 0256

Panto 2: Sudden pressure loss


Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 0256

Check auxiliary air supply


for pantograph
(Somewhere a leakage?).

Fault corrected? Yes

No

Check operation of pressure switch


130.4/2
(see circuit diagram 05A).

Contact 130.4/2.Q2, pin 2


must be at level 0V DC when
pantograph lifted.
If necessary replace pressure switch.

Fault corrected? Yes

No

Check operation of Panto2 EP


Valve 130/1
Check associated wiring to IO
module A216
(see circuit diagram 05A)
If necessary replace EP Valve.

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 66/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
Rear Pantograph 1/2 1/2
Pressure Switch 130.4/2 130.4/2
I/O-Station 22 E211_05 (MprSwPan1), E211_05 (MprSwPan1),
E216(BEPPan2) E216(BEPPan2)

Condition:
- CB I/O station signals (127.9) is on
- Pantograph not cut out by cock
- Auxiliary air supply ok

Criteria:
Rear pantograph lowered without command automatically Pressure present becomes zero.

Reaction:
- Fault code triggered
- VCB off
- All pantographs of vehicle lowered
- Lifiting pantographs inhibited

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 67/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.22 CCU Fault Code 0280

VCB: Switch-on acknowledgement fault


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 68/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0280

Switch on CB.
CB MCB on? Check operation of CBs auxiliary contacts
No
127.12 and associated wiring to
clip-input.
Yes

Restart Loco and try


to switch on VCB.

VCB is on
and message no longer
triggered?

Yes No Check if 72V DC are


available at VCB (5),
pins 1/2 and 21/22
MCB (see circ. Diagram -
was closed and 05C)
No
immediately opened
again?

72V DC available? No
Yes
Yes
Check Power Supply at CB:
72V DC available between
Check/repair wiring from 127.12 pins
MCB
(VCB pin 18 and pin 16)
to associated clip-input
E111_04 and E122_09 resp.
72V DC available? No
(see circ. Diagram 05C ).

Check associated
Yes wiring of CB
Check/repair wiring from VCB Check/repair 127.12 pins.
(5: pin 19 and 17) associated wiring
To CB 127.12 pin 2 from VCB to IO
(see circ. Diagram 05C). station

Check wiring from VCB to CB:


5 to 127.12
(see circ. Diagram 05C)

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 69/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
I/O-Station 11 E111 E111
I/O-Station 12 E122 E122
CB VCB 127.12 127.12

Condition:
- CB VCB (127.12) is on
- CB I/O station signals (127.9) is on
- MVB communication with I/Os 11/12 is ok

Criteria:
Feedback "VCB on" (via I/O E111_04 and E122_09) not detected within 1s after switch on
command.

Reaction:
- Traction converter disabled
- VCB switched off
- VCB on inhibited
- Fault code triggered

Related messages:
FC 0280

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 70/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.23 CCU Fault Code 0281

VCB switch off fault - VCB locked


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 71/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0281

Check if VCB is open and if


this is detected by clip input
E111_04/E122_09.

Check if clip output A116_2/


72V DC A126_0 is closed/energized,
between pins Yes although it should be open/
1/2? deenergized to open VCB
(see circ. Diagram 05B)

No

Exchange clip-
A116_2/A126_0
Yes module
Check/repair wiring from VCB closed/energized?
E116 or E126
to associated clip-input
E111_04/E122_09
(see circ. Diagram 05C ). No

Check if 0V DC are
available at
to open MCB.

Check/repair associated
Check/repair wiring from VCB wiring from
0V DC between
To CB 127.12 No VCB, pin 1/2 to A116_2/
pins 1/2?
A126_0
(see circ. Diagram 05B).

Yes

End

Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
I/O-Station 11 E111 E111
I/O-Station 12 E122 E122
CB VCB 127.12 127.12

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 72/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- CB VCB (127.12) is on
- CB I/O station signals (127.9) is on
- MVB communication with I/Os 11/12 is ok

Criteria:
Feedback "VCB off" from TCU1 and TCU2 not detected within 0.6s after switch off command.

Reaction:
- Traction converter disabled
- VCB switched off
- Pantograph lowered
- VCB on inhibited
- Fault code triggered

Related messages:
FC 0280

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 73/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.24 CCU Fault Code 0282

VCB: loss of ON feedback


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 74/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0282

Switch on CB.
CB VCB on? Check operation of CBs auxiliary contacts
No
127.12 and associated wiring to
clip-input.
Yes

Restart Loco and try


to switch on VCB.

VCB is on
and message no longer
triggered?

Yes No Check if 72V DC are


available at VCB (5),
pins 1/2 and 21/22
MCB (see circ. Diagram -
was closed and 05C)
No
immediately opened
again?

Yes 72V DC available? No

Yes
Check Power Supply at CB:
Check/repair 72V DC available between
Check/repair wiring from associated wiring 127.12 pins
MCB from VCB to IO
(VCB pin 18 and pin 16) station
to associated clip-input
E111_04 and E122_09 resp.
(see circ. Diagram 05C ). 72V DC available? No

Check associated
wiring of CB
Check/repair wiring from VCB Yes
127.12 pins.
(5: pin 19 and 17)
To CB 127.12 pin 2
(see circ. Diagram 05C).

Check wiring from VCB to CB:


5 to 127.12
(see circ. Diagram 05C)

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 75/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
I/O-Station 11 E111 E111
I/O-Station 12 E122 E122
CB VCB 127.12 127.12

Condition:
- CB VCB (127.12) is on
- CB I/O station signals (127.9) is on
- MVB communication with I/Os 11/12 is ok

Criteria:
- Loss of "VCB on" feeedback.
- VCB hardware fault or failure in the activation circuit. In this case the activation of VCB wont be
reseted and this fault code generates.

Reaction:
- Traction converter disabled
- VCB switched off
- VCB on inhibited
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 76/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.25 CCU Fault Code 0287

VCB: Current detected with open VCB


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 77/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0287

Yes MCB open? No

Check functionality of MCB


including auxiliary contacts.

Use Sibas Monitor to check the


following signals CCU:
Sig1: $260068 Return cur. TCU1 Fault corrected? Yes
Sig2: $260368 Return cur. TCU2

No

Check/repair wiring from VCB

to associated clip-inputs
E116_1 / E126_2
(see circ. Diagram 05B ).

Check/repair/replace Line
Sig1 Yes Current Transducer 6.2/2
> 50A (Traction Converter 2).

No

Check/repair/replace Return
Sig2 Yes Current Transducer 6.2/1
> 50A (Traction Converter 1).

No

Check/replace module Check/replace module


415/2 Yes 415/1
(TCU2 / Traction Converter 2). (TCU1 / Traction Converter 1).

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 78/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
TCU1, Input module 415/1 415/1
TCU2, Input module 415/2 415/2
Line Current Transducer 6.2 6.2
I/O-Station 11/12 E116/E126 E116/E126

Condition:
- CB VCB (127.12) is on.
- CB I/O station signals (127.9) is on.
- MVB communication with I/Os 11/12 is ok.
- VCB I current fault is not disabled and BRAM is not reseted.

Criteria:
CCU detects status VCB off, while at least one TCU detects a line current > 50A.

Reaction:
- VCB switched off
- Pantograph lowered
- Fault code triggered

Related messages:
-

3.2.26 CCU Fault Code 0295


VCB: TCU requested help from CCU to open the VCB
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 79/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 0295

TCU called CCU for help


to open VCB. For further
Troubleshooting readout
Diagnostic memory of
TCUs and scan for
Diagnostic messages.

End

Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
TCU1 415/1 415/1
TCU2 415/2 415/2
CCU

Condition:
-

Criteria:
TCU is not able to open VCB.
CCU received call for help from TCU topen VCB

Reaction:
- VCB switched off
- Fault code triggered

Related messages:
-

3.2.27 CCU Fault Code 0340


VCB off: Catenary overvoltage
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 80/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0340

Voltage >31 kV Yes

Check Voltage sensors and


Meter reading. If required
relace sensor

No

End

Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
TCU1 415/1 415/1
TCU2 415/2 415/2
CCU

Condition:
- CCU must be master.

Criteria:
- AC line voltage detected by TCU is greater than 31KV
- Catenary voltage is not more than 33kV.

Reaction:
- VCB switched off
- Fault code triggered

Related messages:
-
3.2.28 CCU Fault Code 0341
VCB locked: Catenary thermal protection
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 81/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0341

Diagnostic message only


for information.
No remedy action
necessary.

End

Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
TCU1 415/1 415/1
TCU2 415/2 415/2
CCU
IO station 11 A116 A116
IO station 12 A126 A126

Condition:
- CCU must be master.
- MVB communication with IO station 11 & 12 is ok.
- VCB is ON.

Criteria:
- AC line voltage detected by TCU is greater than 29KV

Reaction:
- VCB is opened
- VCB is locked.
- Fault code triggered

Related messages:
-
3.2.29 CCU Fault Code 0342
VCB off: Catenary undervoltage
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 82/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0342

Voltage <16 kV Yes

Check Voltage sensors and


Meter reading. If required
relace sensor

Check Voltage sensors and


No Meter reading. If required
relace sensor

End

Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
TCU1 415/1 415/1
TCU2 415/2 415/2
CCU

Condition:
- CCU must be master.
- Atleast one panto is raised for min 6 sec.
- Communication with TCU is ok.
- Minimum catenary voltage (0.5KV)should be detected.
- Locomotive is not in phase break section.

Criteria:
- AC line voltage detected by TCU is less than 16KV.

Reaction:
- VCB switched off
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 83/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.30 CCU Fault Code 0343
VCB off: Line voltage 5th harmonic too high
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0343

Diagnostic message only


for information.
No remedy action
necessary.

End

Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
TCU1 415/1 415/1
TCU2 415/2 415/2
CCU

Condition:
- CCU must be master.
- One pantograph must raise for atleast

Criteria:
- Ac line harmonic voltage detected by TCU is greater than 9.2kV.

Reaction:
- VCB is opened
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 84/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.31 CCU Fault Code 0344
VCB off: Voltage instantaneous value too high
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0344

Diagnostic message only


for information.
No remedy action
necessary.

End

Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
TCU1 415/1 415/1
TCU2 415/2 415/2
CCU

Condition:
- CCU must be master.
- One pantograph must raise

Criteria:
- Ac line harmonic voltage detected by TCU is greater than 9.2kV.

Reaction:
- VCB is opened
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 85/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.32 CCU Fault Code 0345
Variance between TCU 1 and TCU 2: Catenary harmonic voltage
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0345

Check Voltage sensors


Yes
224.1/1 and 224.1/2 . OK?

Diagnostic message
only for information.
No
No remedy action
necessary.

If necessary replace
sensors

End

Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
TCU1 415/1 415/1
TCU2 415/2 415/2
CCU

Condition:
- CCU must be master.
- Communication with atleast one TCU is OK.

Criteria:
- Maximum difference between TCU1 and TCU2 catenary harmonic voltage is greater than 1 kV.

Reaction:
-

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 86/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.33 CCU Fault Code 0346
Variance between TCU 1 and TCU 2: Catenary instantaneous value
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0346

Check Voltage sensors


Yes
224.1/1 and 224.1/2 . OK?

Diagnostic message
only for information.
No
No remedy action
necessary.

If necessary replace
sensors

End

Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
TCU1 415/1 415/1
TCU2 415/2 415/2
CCU

Condition:
- CCU must be master.
- Communication with atleast one TCU is OK.

Criteria:
- Maximum difference between instataneous value of AC line voltage detected by TCU1 and
TCU2 is greater than 1 kV.

Reaction:
-

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 87/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.34 CCU Fault Code 0348
Variance between TCU 1 and TCU 2: Catenary voltage detection
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0348

Check Voltage sensors


Yes
224.1/1 and 224.1/2 . OK?

Diagnostic message
only for information.
No
No remedy action
necessary.

If necessary replace
sensors

End

Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
TCU1 415/1 415/1
TCU2 415/2 415/2
CCU

Condition:
- CCU must be master.
- Communication with atleast one TCU is OK.

Criteria:
- Maximum difference between AC line voltage detected by TCU1 and TCU2 is greater than 1 kV.

Reaction:
-

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 88/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.35 CCU Fault Code 0349
Variance between TCU 1 and TCU 2: Catenary frequency detection
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0349

Diagnostic message only


for information.
No remedy action
necessary.

End

Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
TCU1 415/1 415/1
TCU2 415/2 415/2
CCU

Condition:
- CCU must be master.
- Communication with atleast one TCU is OK.

Criteria:
- Maximum difference between AC frequency detected by TCU1 and TCU2 is greater than 5 Hz.

Reaction:
-

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 89/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.36 CCU Fault Code 0364
VCB locked: Current monitoring triggerd twice
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0364

Diagnostic message only


for information.
No remedy action
necessary.
Contact Siemens Service
engineer.

End

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
-

Criteria:
- Input current has exceeded the maximum value twice which could be dangerous and may lead to
another faults and damage of componenets hence VCB is locked and this message is triggered.

Reaction:
- VCB locked.
- Panto locked.

Related messages:
-

3.2.37 CCU Fault Code 0367


VCB off: Catenary overcurrent
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 90/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0367

Check for the following reasons:


1. Disturbance in measurement of primary
current. Check the primary current sensor
6.2/1.
2. Fault in converter.
3. Short circuit in transformer winding.
4. Check machine room for oil flash/smoke/
abnormal.
5. Check OCR.78 is normal.
If anything is not ok then shut the Loco.

End

Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
TCU1 415/1 415/1
TCU2 415/2 415/2
IO station 12 E123 E123
Maximum current relay 78 78

Condition:
- Communication with IO Module E123_07 is ok
- Communication with atleast one TCU is OK.
- Current monitoring is not disabled.
- CCU is master.

Criteria:
- AC line current detected by TCU is greater than 450A for atleast 2.5 sec
- AC overcurrent is detected in either TCU1 or TCU2.
- High primary current is detected by mximum current relay(78).

Reaction:
- Panto Locked.
- VCB off.
- TCU disabled.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 91/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 92/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.38 CCU Fault Code 0375
Variance between TCU 1 and TCU 2: Catenary current detection
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0375

Check Voltage sensors


Yes
6.2/1 and 6.2/2. OK?

Diagnostic message
only for information.
No
No remedy action
necessary.

If necessary replace
sensors

End

Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
TCU1 415/1 415/1
TCU2 415/2 415/2
CCU

Condition:
- CCU must be master.
- Communication with atleast one TCU is OK.

Criteria:
- Maximum difference between AC line current detected by TCU1 and TCU2 is greater than 40A.

Reaction:
- Fault code triggered.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 93/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.39 CCU Fault Code 0384
VCB off: Inrush current exceeding limit
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0384

Check wiring of for Short circuits. This includes the


following devices:
- Line current converter
- current sensor
- Main transformer
(see circ. Diagrams 01A,12B)

- Reset MCB lock in CCU BRAM


- Switch on MCB

Check wiring of following for Short circuits.


That includes:
- Traction converters
Problem solved? No
- Traction motors
- All auxiliary loads on the loco
Yes

- Reset MCB lock in CCU BRAM


- Switch on MCB

Internal defect in Main


No Problem solved?
Transformer.

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 94/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
VCB 5 5
TCU1 415/1 415/1
TCU2 415/2 415/2
IO station 11 A116 A116
IO station 12 A126 A126

Condition:
- Communication with output A116_1 and A126_2 is ok
- Communication with atleast one TCU is OK.
- Current monitoring is not disabled.
- CCU is master.

Criteria:
- Trafo no load inrush current after VCB ON is too high.

Reaction:
- Panto lock
- VCB off.
- Fault code triggered.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 95/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.40 CCU Fault Code 0399
Energy meter: Energy measurements stopped
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0399

Check energy meter is ok


Yes

No Check Communication with TCU


If required change TCU Module

Replace Energy Meter

End

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:

Criteria:
- Communication with TCU is not ok.

Reaction:
- Fault code triggered.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 96/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.41 CCU Fault Code 0400
VCB loop test: conditions missing
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 400

Check the following conditions for the VCB loop test:


- Cab activated, BL key in D position.
- Pantograph lowered
- VCB opened
- Reverser in center
- Throttle in idle
- Loco speed is zero

Start VCB loop


test again.

End

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
-

Criteria:
- VCB loop test couldn’t be started because of missing conditions.

Reaction:
- Fault code triggered.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 97/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.42 CCU Fault Code 0403
VCB loop test: TCU 1 4QC contact failed
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 403

Check LED status of Input


module pins E111_15 and
E123_00.
Check IO station CB is ON
and communication is OK

Check IO station CB is ON and


Feedback available,
No communication is OK. Check
LEDs ON?
wiring. If necessary change
Wiring or replace module

Yes

Check wiring of VCB loop


(see circ. Diagram 05B).

Start VCB loop test again.

Exchange TCU1
Fault triggered agai? Yes
4QC module.

No

End

Components concerned:
Component Device name CCU1 Device name CCU2
4QC TCU1

Condition:
- Communication with master CCU is ok.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 98/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Communication with IO station 11 and 12 is ok.

Criteria:
- TCU1 4QC module is faulty.

Reaction:
- Fault code triggered.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 99/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.43 CCU Fault Code 0404
VCB loop test: TCU1 one of the PWR contacts failed
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 404

Check LED status of Input


module pins E111_15 and
E123_00.
Check IO station CB is ON
and communication is OK

Check IO station CB is ON and


Feedback available,
No communication is OK. Check
LEDs ON?
wiring. If necessary change
Wiring or replace module

Yes

Check wiring of VCB loop


(see circ. Diagram 05B).

Start VCB loop test again.

Fault triggered Exchange TCU1 faulty


Yes
again? PWR module.

No

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 100/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
PWR TCU1 PWI-A/C TCU1 PWI-A/C TCU1

Condition:
- Communication with master CCU is ok.
- Communication with IO station 11 and 12 is ok.

Criteria:
- TCU1 one of the PWR module is faulty.

Reaction:
- Fault code triggered.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 101/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.44 CCU Fault Code 0406
VCB loop test: TCU 2 4QC contact failed
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 406

Check LED status of Input


module pins E111_15 and
E123_00.
Check IO station CB is ON
and communication is OK

Check IO station CB is ON and


Feedback available,
No communication is OK. Check
LEDs ON?
wiring. If necessary change
Wiring or replace module

Yes

Check wiring of VCB loop


(see circ. Diagram 05B).

Start VCB loop test again.

Exchange TCU2
Fault triggered agai? Yes
4QC module.

No

End

Components concerned:
Component Device name CCU1 Device name CCU2
4QC TCU2

Condition:
- Communication with master CCU is ok.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 102/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Communication with IO station 11 and 12 is ok.

Criteria:
- TCU2 4QC module is faulty.

Reaction:
- Fault code triggered.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 103/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.45 CCU Fault Code 0407
VCB loop test: TCU2 one of the PWR contacts failed
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 407

Check LED status of Input


module pins E111_15 and
E123_00.
Check IO station CB is ON
and communication is OK

Check IO station CB is ON and


Feedback available,
No communication is OK. Check
LEDs ON?
wiring. If necessary change
Wiring or replace module

Yes

Check wiring of VCB loop


(see circ. Diagram 05B).

Start VCB loop test again.

Exchange TCU2
Fault triggered
Yes faulty PWR
again?
module.

No

End

Components concerned:
Component Device name CCU1 Device name CCU2
PWR TCU2 PWI-A/C TCU2 PWI-A/C TCU2

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 104/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- Communication with master CCU is ok.
- Communication with IO station 11 and 12 is ok.

Criteria:
- TCU2 one of the PWR module is faulty.

Reaction:
- Fault code triggered.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 105/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.46 CCU Fault Code 0409
VCB loop test: ExtIO 11 contact failed
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 409

Switch off & On again CB of


IO station 11 (127.9/1).

Message active?

Yes

Check IO modules E116 and


E111_15. If module is faulty
replace or repair the module.

Check/repair/replace
Fault still triggered ? Yes wiring between IO and
CCU

No

End

Components concerned:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 106/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Component Device name CCU1 Device name CCU2
IO station 11 E111 E111
E116 E116

Condition:
- VCB loop test released.

Criteria:
- In contact testing even after resetting the contactor pins of relay module E116_0NO, E116_1NO
feedback is available on digital input E111_15 for more than 2sec. This means relay module of IO
station 11, E116 is faulty or there can be problem in connection between CCU to relay module and
DI E111_15 to CCU.

Reaction:
- Fault code triggered.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 107/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.47 CCU Fault Code 0410
VCB loop test: ExtIO 12 contact failed
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 410

Switch off & On again CB of


IO station 12 (127.9/2).

Message active?

Yes

Check IO modules E126 and


E123_00. If module is faulty
replace or repair the module.

Check/repair/replace
Fault still triggered ? Yes wiring between IO and
CCU

No

End

Components concerned:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 108/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Component Device name CCU1 Device name CCU2
IO station 12 E123 E123
E126 E126

Condition:
- VCB loop test released.

Criteria:
- In contact testing even after resetting the contactor pins of relay module E126_1NO, E126_2NO
feedback is available on digital input E123_00 for more than 2sec. This means relay module of IO
station 12, E126 is faulty or there can be problem in connection between CCU to relay module and
DI E123_00 to CCU.

Reaction:
- Fault code triggered.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 109/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.48 CCU Fault Code 0421
VCB loop: TCU 1 is switched off but VCB loop is opened
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 421

Check that CB TCU1


(127.11/1) is ON,
communication with
TCU1 is OK.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU1 415/1 415/1
VCB CB 127.12 127.12
IO station 12 E123 E123

Condition:
- CB 127.12 is ON.
- Communication with master CCU is ok.
- One cab occupied.
- Emergency stop is not activated.
- Communication with IO E123_07 is ok.
- Communication with TCU is ok.

Criteria:
- TCU1 not available.
- Feedback loop Voltage before and after TCU1 is not equal.

Reaction:
- Fault code triggered.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 110/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.49 CCU Fault Code 0422
VCB loop: TCU 2 is switched off but VCB loop is opened
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 422

Check that CB TCU2


(127.11/2) is ON,
communication with
TCU2 is OK.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU2 415/2 415/2
VCB CB 127.12 127.12
IO station 12 E123 E123

Condition:
- CB 127.12 is ON
- Communication with master CCU is ok.
- One cab occupied.
- Emergency stop is not activated.
- Communication with IO E123_07 is ok.
- Communication with TCU is ok.

Criteria:
- TCU2 not available.
- Feedback loop Voltage before and after TCU2 is not equal.

Reaction:
- Fault code triggered.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 111/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.50 CCU Fault Code 0423

CB 127.12 is tripped
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 423

Close circuit
breaker 127.12.

CB trips again? Yes

No Isolate connections to -
127.12.

Message gone? No

Check operation of auxiliary CB trips again? No


contacts of 127.12
Yes
Yes

Check circuits connected to


Replace circuit
CB contacts for short circuits
breaker 127.12.
(see circ. Diagram 04C.03
Check/repair wiring of auxiliary contacts 05A_04,05C.1,05H.2).

End

Components concerned:
Component Device name CCU1 Device name CCU2
CB Pantograph & VCB 127.12 127.12
I/O-Station 12 E123 E123

Condition:
- CCU is master.
- Atleast one cab is active/occupied
- Emergency stop switch is off

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 112/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Communication with either TCU 1 or TCU 2 is ok
-CB I/O station signals (127.9/2) is on
- MVB communication with I/O 12 is ok

Criteria:
- CB 127.12 is off
- Primary AC current is high.

Reaction:
- Fault code triggered
- MCB off
- All pantographs of vehicle lowered
- Lifiting pantographs inhibited

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 113/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.51 CCU Fault Code 0430

Safety Relay Control Electronics On 126.6 Failed


Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 0430

Check/repair wiring to Safety relay 126.6, E111_06 and


E122_11:
125/1.2 to 126.6.A1
125/2.2 to 126.6.A1
125/1.1 to 126.7/1.2
125/2.1 to 126.7/1.2
126.6.87 to 127.9/1
126.6.88 to E111_06 & E122_11 (411.LA/11)

(see circ. Diagram 08A)

Check relay 126.6


Message gone? No
If necessary replace it by a
trouble-free spare part

Yes Message gone?

No

Yes
Check digital input module E111
and E122

If necessary replace modules by


a trouble-free spare part

End

Components concerned:
Component Device name CCU1 Device name CCU2
Safety relay control electronics ON 126.6 126.6

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 114/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- Communication between CCU and I/O station 11 and 12 is ok.

Criteria:
- BL key in drive position.
- No feedback from safety relay.

Reaction:
- Fault code triggered

Related messages:

3.2.52 CCU Fault Code 0460

Angle transmitter: mismatch detected


Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 115/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 460

Check/repair wiring between IO module


E112 : CB station11& 127.9/1,
E121 :CB station12 & 127.9/2,
E112_00 : angle trasnmitter
E111_00, E121_12,
E121_02,E121_10,E121_11 to throttle
auxiliary contacts
(see circ. Diagram 08C)

Wiring OK? Yes

No

Change wiring

Check and exchange


Angle transmitter (150.1/
1)see circ. Diagram 08C).

End

Components concerned:

Component Device name CCU1 Device name CCU2


Angle transmitter 150.1/1 150.1/1

Condition:
- Particular cab is active.

Criteria:
- Mismatch between angle transmitter and throttle auxiliary contactor values either Cab.
- Angle transmitter faulty.

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 116/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Related messages:
-

3.2.53 CCU Fault Code 0461

Cab 1 Angle transmitter: Value implausible


Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 117/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 461

Check/repair wiring to IO module pin


EA112.00 and IO station CB 127.9/1 and to
the angle transmitter (see circ. Diagram
08C)

Wiring OK? Yes

Check and exchange


No
Angle transmitter (150.1/
1)see circ. Diagram 08C).

Change wiring

End

Components concerned:
Component Device name CCU1 Device name CCU2
Angle transmitter 150.1/1 150.1/1

Condition:
- Cab 1 is active
- Angle transmitter cab 1 is valid

Criteria:
- CB I/O station signals (127.9/1) is On
- Angle transistor cab 1 is implausible

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 118/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.54 CCU Fault Code 0462

Cab 2 Angle transmitter: Value implausible


Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 462

Check/repair wiring to IO module pin


EA213.00 and IO station CB 127.9/3 and to
the angle transmitter (see circ. Diagram
08C)

Wiring OK? Yes

No Check and exchange


Angle transmitter (150.1/
2)see circ. Diagram 08C).
Change wiring

End

Components concerned:
Component Device name CCU1 Device name CCU2
Angle transmitter 150.1/2 150.1/2

Condition:
- Cab 2 is active
- Angle transmitter cab 2 is valid

Criteria:
- CB I/O station signals (127.9/3) is On
- Angle transistor cab 2 is implausible

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 119/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 120/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.55 CCU Fault Code 0491

Tractive effort without demand at PWI 1A.


Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 0491

Check Angle
transmitter, Ok?

Yes

Message No
occurred more than 3 times
within the last
No
month?

Ignore it.
Yes

Inform Siemens
Maintenance Repair it.
Personnel.

End

Components concerned:
Component Device name CCU1 Device name CCU2
- - -

Condition:
- CCU is master

Criteria:
Traction effort on Traction motor 1 in bogie 1 without command.

Reaction:
- VCB switched off
- VCB on inhibited

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 121/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Traction Motor 1 cut out
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 122/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.56 CCU Fault Code 0492

Tractive effort without demand at PWI 1B.


Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0492

Check Angle
transmitter, Ok?

Yes

Message No
occurred more than 3 times
within the last
No
month?

Ignore it.
Yes

Inform Siemens
Maintenance Repair it.
Personnel.

End

Components concerned:
Component Device name CCU1 Device name CCU2
- - -

Condition:
- CCU is master

Criteria:
Traction effort on Traction motor 2 in bogie 1 without command.

Reaction:
- VCB switched off
- VCB on inhibited

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 123/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Traction Motor 2 cut out
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 124/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.57 CCU Fault Code 0493

Tractive effort without demand at PWI 1C.


Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0493

Check Angle
transmitter, Ok?

Yes

Message No
occurred more than 3 times
within the last
No
month?

Ignore it.
Yes

Inform Siemens
Maintenance Repair it.
Personnel.

End

Components concerned:
Component Device name CCU1 Device name CCU2
- - -

Condition:
- CCU is master

Criteria:
Traction effort on Traction motor 3 in bogie 1 without command.

Reaction:
- VCB switched off
- VCB on inhibited

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 125/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Traction Motor 3 cut out
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 126/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.58 CCU Fault Code 0494

Tractive effort without demand at PWI 2C.


Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0494

Check Angle
transmitter, Ok?

Yes

Message No
occurred more than 3 times
within the last
No
month?

Ignore it.
Yes

Inform Siemens
Maintenance Repair it.
Personnel.

End

Components concerned:
Component Device name CCU1 Device name CCU2
- - -

Condition:
- CCU is master

Criteria:
Traction effort on Traction motor 4 in bogie 2 without command.

Reaction:
- VCB switched off
- VCB on inhibited

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 127/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Traction Motor 4 cut out
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 128/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.59 CCU Fault Code 0495

Tractive effort without demand at PWI 2B.


Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0495

Check Angle
transmitter, Ok?

Yes

Message No
occurred more than 3 times
within the last
No
month?

Ignore it.
Yes

Inform Siemens
Maintenance Repair it.
Personnel.

End

Components concerned:
Component Device name CCU1 Device name CCU2
- - -

Condition:
- CCU is master

Criteria:
Traction effort on Traction motor 5 in bogie 2 without command.

Reaction:
- VCB switched off
- VCB on inhibited

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 129/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Traction Motor 5 cut out
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 130/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.60 CCU Fault Code 0496

Tractive effort without demand at PWI 2A.


Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0496

Check Angle
transmitter, Ok?

Yes

Message No
occurred more than 3 times
within the last
No
month?

Ignore it.
Yes

Inform Siemens
Maintenance Repair it.
Personnel.

End

Components concerned:
Component Device name CCU1 Device name CCU2
- - -

Condition:
- CCU is master

Criteria:
Traction effort on Traction motor 6 in bogie 2 without command.

Reaction:
- VCB switched off
- VCB on inhibited

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 131/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Traction Motor 6 cut out
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 132/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.61 CCU Fault Code 0500
AGT traction release fault TCU 1.
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 133/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0500

244/1 or 244/2 Deactivate Electrical emergency


Yes
activated? off 244/1 and 244/2.

No
Replace following modules
consecutively and check if
72V DC
problem solved:
218 active? Yes available at TCUs XK42A Yes
A3-PWMI A/TCC-1
pins 6/7
A4-PWMI B/TCC-1
No A5-PWMI C/TCC-1

No
Check operation of 218 auxiliary contacts
72V DC
available between No
218.A1/A2?

Check/repair wiring to TCU1 Inputs:


Yes 218 to 127.11/1.(72V DC)
218 to XK42A.6/
Replace XK42A.7 to 127.11/1.(GND)
218. (see circ. Diagram 04D, 09C)

Check/repair wiring:
218.A1 to 126.1 (72V DC)
218.A2 to 126.2 (GND)
(see circ. Diagram 04D)

Yes Problem solved?

No

Replace the following devices consecutively


and check if problem solved: 244/1/ 244/2 /
127.1/1 / CCU Input/output module

Check operation of
Yes Problem solved? No
126.

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 134/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
Control electronics contactor 218 218
CB Electronics Converter 127.11/1 127.11/1
CB CCU 127.1/1 127.1/1
Emergency stop pushbutton cab1 244/1 244/1
Emergency stop pushbutton cab2 244/2 244/2
TCU1 415/1 415/1
Inverter PWI 1A A3-PWMI A/TCC-1 A3-PWMI A/TCC-1
Inverter PWI 1B A4-PWMI B/TCC-1 A4-PWMI B/TCC-1
Inverter PWI 1C A5-PWMI C/TCC-1 A5-PWMI C/TCC-1
CONTACTOR CONTROL CIRCUIT 126 126
ON

Condition:
- TCU1 traction is locked.
- AGT1 TCU1 traction released.
- AGT2 TCU1 traction released.
- TCU1 Communication OK.
- CCU should be master.

Criteria:
- Traction is locked at PWI 1A or PWI 1B or PWI 1C or TCU1.
- Actual torque status input from TCU1 should be 0.
- AGT1 and AGT2 self test is not active.
- TE/BE demand is not zero.
- Emergency brake applied is not applied.
- Emergency stop button is not activated.
- No traction interlock on train and locomotive.
Reaction:
-Concerned PWI inverter in TCU1 is disabled.
- TCU1 interlock won’t be released.
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 135/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.62 CCU Fault Code 0501
AGT traction interlock fault TCU 1.
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 136/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0501

72V DC
No available at TCUs XK42A No
218 active?
pins 6/7
Yes

Yes
72V DC
available between Yes Replace following modules
218.A1/A2? consecutively and check if
Replace the following devices problem solved:
consecutively and check if A3-PWMI A/TCC-1
No problem solved: A4-PWMI B/TCC-1
127.1/1 / CCU Input/output A5-PWMI C/TCC-1
module
Check operation of 218 auxiliary
contacts

Replace
218

Check/repair wiring to TCU1 Inputs:


218 to 127.11/1.(72V DC)
218 to XK42A.6/
Yes Problem solved? XK42A.7 to 127.11/1.(GND)
(see circ. Diagram 04D, 09C)
No

Check/repair wiring:
218.A1 to 126.1 (72V DC)
218.A2 to 126.2 (GND)
(see circ. Diagram 04D)

End

Components concerned:
Component Device name CCU1 Device name CCU2
Control Electronics Contactor 218 218
CB Electronics Converter 127.11/1 127.11/1
CB CCU 127.1/1 127.1/1
TCU1 415/1 415/1
Inverter PWI 1A A3-PWMI A/TCC-1 A3-PWMI A/TCC-1
Inverter PWI 1B A4-PWMI B/TCC-1 A4-PWMI B/TCC-1
Inverter PWI 1C A5-PWMI C/TCC-1 A5-PWMI C/TCC-1
CONTACTOR CONTROL CIRCUIT ON 126 126

Condition:
- TCU1 traction is not locked.
- AGT1 TCU1 traction not released.
- AGT2 TCU1 traction not released.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 137/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- TCU1 Communication OK.
- CCU should be master.

Criteria:
- No traction lock at PWI 1A or PWI 1B or PWI 1C or TCU1.
- Actual torque status input from TCU1 is not 0.
- AGT1 or AGT2 self-test is active.
- TE/BE demand is zero (or between 0kN – 1kN).
- Emergency brake applied is applied.
- Emergency stop button is activated.
- Traction interlock on train or locomotive.
Reaction:
- Fault code triggered
- VCB open.
- TCU1 interlock is not possible.
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 138/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.63 CCU Fault Code 0505

SW version conflict, Traction block


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0506

Check software version of:


• Display Software
• CCU software
• CCU NSDB version
• LION software
• TCU software
• TCN software
• Battery charger software
Software Version should be latest one.

End

Components concerned:
Component Device name CCU Device name CCU
- -

Condition:
- Workshop mode should not be active.

Criteria:
Software version conflict is present

Reaction:
- Fault code triggered
- Traction lock active

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 139/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.64 CCU Fault Code 0506

SW version conflict, Traction block


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0506

Check software version of:


• Display Software
• CCU software
• CCU NSDB version
• LION software
• TCU software
• TCN software
• Battery charger software
Software Version should be latest one.

End

Components concerned:
Component Device name CCU Device name CCU
- -

Condition:
- Workshop mode active.

Criteria:
Software version conflict is present

Reaction:
- Fault code triggered
- Software version conflict overwritten.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 140/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.65 CCU Fault Code 0516
TCU 1 fault Self OFF req
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 0516

Try to activate TCU1 to


readout diagnostic memory.
If it is not possible to activate
it permanently to read out the
data, remove CPU module
from TCU1 and plug in other
TCU to access diagnostic
data.

Check Diagnostic memory of TCU1


for entries regarding:
- Wrong SW loaded on CPU /
4QC / PWI / HEP
- TC switch gear
- HEP switch gear

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU1 415/1 415/1

Condition:
-
Criteria:
TCU1 send self off request to CCU, because of internal faults.

Reaction:
- TCU1 is off
- Main Inverter 1 off
- MCB off
- MCB inhibited
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 141/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.66 CCU Fault Code 0517
TCU 2 fault Self OFF req
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 0517

Try to activate TCU2 to


readout diagnostic memory.
If it is not possible to activate
it permanently to read out the
data, remove CPU module
from TCU2 and plug in other
TCU to access diagnostic
data.

Check Diagnostic memory of TCU2


for entries regarding:
- Wrong SW loaded on CPU /
4QC / PWI / HEP
- TC switch gear
- HEP switch gear

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU2 415/2 415/2

Condition:
-

Criteria:
TCU2 send self off request to CCU, because of internal faults.

Reaction:
- TCU2 is off
- Main Inverter 2 off
- MCB off
- MCB inhibited
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 142/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.67 CCU Fault Code 0520
AGT traction release fault TCU 2.

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 143/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0520

244/1 or 244/2 Deactivate Electrical emergency


Yes
activated? off 244/1 and 244/2.

No
Replace following modules
consecutively and check if
72V DC
problem solved:
218 active? Yes available at TCUs XK57A Yes
A3-PWMI A/TCC-2
pins 6/7
A4-PWMI B/TCC-2
No A5-PWMI C/TCC-2

No
72V DC
available between No
218.A1/A2?

Check operation of 218 auxiliary contacts


Yes

Check/repair wiring:
Replace 218.A1 to 126.1 (72V DC)
218. 218.A2 to 126.2 (GND)
(see circ. Diagram 04D)

Check/repair wiring to TCU2 Inputs:


218 to 127.11/2.(72V DC)
Yes Problem solved? 218 to XK57A.6/
XK57A.7 to 127.11/2.(GND)
(see circ. Diagram 04D, 09C)
No

Replace the following devices consecutively


and check if problem solved: 244/1/ 244/2 /
127.1/2 / CCU Input/output module

Check operation of
Yes Problem solved? No
126.

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 144/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
Control electronics contactor 218 218
CB Electronics Converter 127.11/2 127.11/2
CB CCU 127.1/2 127.1/2
Emergency stop pushbutton cab1 244/1 244/1
Emergency stop pushbutton cab2 244/2 244/2
TCU2 415/2 415/2
Inverter PWI 2A A3-PWMI A/TCC-2 A3-PWMI A/TCC-2
Inverter PWI 2B A4-PWMI B/TCC-2 A4-PWMI B/TCC-2
Inverter PWI 2C A5-PWMI C/TCC-2 A5-PWMI C/TCC-2
CONTACTOR CONTROL CIRCUIT ON 126 126

Condition:
- TCU2 traction is locked.
- AGT1 TCU2 traction released.
- AGT2 TCU2 traction released.
- TCU2 Communication OK.
- CCU should be master.

Criteria:
- Traction is locked at PWI 2A or PWI 2B or PWI 2C or TCU2.
- Actual torque status input from TCU2 should be 0.
- AGT1 and AGT2 self test is not active.
- TE/BE demand is not zero.
- Emergency brake applied is not applied.
- Emergency stop button is not activated.
- No traction interlock on train and locomotive.
Reaction:
-Concerned PWI inverter in TCU2 is disabled.
- TCU2 interlock won’t be released.
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 145/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.68 CCU Fault Code 0521
AGT traction interlock fault TCU 2.
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 146/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0521
Replace following modules
consecutively and check if
72V DC
problem solved:
218 active? No available at TCUs XK57A No
A3-PWMI A/TCC-2
pins 6/7
A4-PWMI B/TCC-2
Yes A5-PWMI C/TCC-2

Yes
72V DC
available between Yes
218.A1/A2?

Replace the following devices consecutively


and check if problem solved: Check operation of 218 auxiliary contacts
No 127.1/2 / CCU Input/output module

Replace
218 Check/repair wiring to TCU1 Inputs:
218 to 127.11/2.(72V DC)
218 to XK57A.6/
Yes Problem solved? XK57A.7 to 127.11/2.(GND)
(see circ. Diagram 04D, 09C)
No

Check/repair wiring:
218.A1 to 126.1 (72V DC)
218.A2 to 126.2 (GND)
(see circ. Diagram 04D)

End

Components concerned:
Component Device name CCU1 Device name CCU2
Control Electronics Contactor 218 218
CB Electronics Converter 127.11/2 127.11/2
CB CCU 127.1/2 127.1/2
TCU2 415/2 415/2
Inverter PWI 2A A3-PWMI A/TCC-2 A3-PWMI A/TCC-2
Inverter PWI 2B A4-PWMI B/TCC-2 A4-PWMI B/TCC-2
Inverter PWI 2C A5-PWMI C/TCC-2 A5-PWMI C/TCC-2
CONTACTOR CONTROL CIRCUIT 126 126
ON

Condition:
- TCU2 traction is not locked.
- AGT1 TCU2 traction not released.
- AGT2 TCU2 traction not released.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 147/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- TCU2 Communication OK.
- CCU should be master.

Criteria:
- No traction lock at PWI 2A or PWI 2B or PWI 2C or TCU2.
- Actual torque status input from TCU2 is not 0.
- AGT1 or AGT2 self-test is active.
- TE/BE demand is zero (or between 0kN – 1kN).
- Emergency brake applied is applied.
- Emergency stop button is activated.
- Traction interlock on train or locomotive.
Reaction:
- Fault code triggered
- VCB open.
- TCU2 interlock is not possible.
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 148/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.69 CCU Fault Code 0530
TC1: CoolBlower Failed

Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 00530

Close circuit breaker


59.1/1

CB trips again? Yes

Isolate connections to
No
59.1/1

Message gone? No

Check operation of 59.1/1 CB trips again? No


auxiliary contacts

Yes
Check/repair wiring between IO module Check circuits connected to
Yes E122_04 and 59.1/1 Replace circuit CB contacts for short circuits
(see circ. Diagram 05G) breaker (see circ. Diagram 05G).
59.1/1

End

Components concerned:

Component Device name CCU1 Device name CCU2


CB to oil cooling blower 59.1/1 59.1/1
IO station 12 E122 E122
CB monitoring1 127.1/1 127.1/1

Condition:
- Atleast one aux converter is running and supplying to the loads.
- CB monitoring1 ok.
- CB to oil cooling blower ok

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 149/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- IO station 12 or module E122 is ok.

Criteria:
- CB of TC1 blower is opened.
- No signal from E122_04.

Reaction:
- Fault code triggered
- TC1 blower is inoperative
- TC1 cooling failed.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 150/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.70 CCU Fault Code 0531
TC1: WaterCirculatin fault

Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 00531

Close circuit breaker


63.1/1

CB trips again? Yes

Isolate connections to
No
63.1/1

Message gone? No

Check operation of 59.1/1 CB trips again? No


auxiliary contacts

Yes
Check/repair wiring between IO module Check circuits connected to
Yes E122_02 and 63.1/1 Replace circuit CB contacts for short circuits
(see circ. Diagram 05G) breaker (see circ. Diagram 05G).
63.1/1

End

Components concerned:

Component Device name CCU1 Device name CCU2


CB OIL PUMP1 CONVERTER 63.1/1 63.1/1
IO station 12 E122 E122
CB monitoring1 127.1/1 127.1/1

Condition:
- Atleast one aux converter is running and supplying to the loads.
- CB monitoring1 ok.
- CB to oil pump1 converter ok
- IO station 12 or module E122 is ok.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 151/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Criteria:
- CB of TC1 water pump is opened.
- No signal from E122_02.

Reaction:
- Fault code triggered
- TC1 water pump is inoperative
- TC1 cooling failed.

Related messages:
-

3.2.71 CCU Fault Code 0532

TC1: Coolant Pressure High


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 152/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 532

Check/repair pressure senosr

Check/repair wiring from 218 to 127.2/1


(72V DC)(see circ. Diagram 05G)

Message still active? No

Yes

Check/repair wiring from Klip E122_02:


411.QA/3 to 63.1/1.24
63.1/1.23 to 127.2/1
(see circ. Diagram 05G)

End

Components concerned:
Component Device name CCU1 Device name CCU2
Traction converter 1 415/1 415/1

Condition:
- At least one Aux converter is running
- MVB communication with TCU is ok
- Control electronics contactor (218) is on
- CB monitoring1 (127.2/1) is on
- CB converter pump1 (63.1/1) is on

Criteria:
- pressure sensor of traction converter 1 is broken
- coolant pressure of traction converter 1 is too high and has to be adjusted

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 153/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Reaction:
- Fault code triggered
- VCB opened
- Locomotive not operational

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 154/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.72 CCU Fault Code 0533

TC1: Coolant Pressure Low


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 533

Check/repair pressure senor

Check/repair wiring from 218 to 127.2/1


(72V DC)(see circ. Diagram 05G)

Message still active? No

Yes

Check/repair wiring from Klip E122_02:


411.QA/3 to 63.1/1
63.1/1 to 127.2/1
(see circ. Diagram 05G)

End

Components concerned:
Component Device name CCU1 Device name CCU2
Traction converter 1 415/1 415/1

Condition:
- At least one Aux converter is running
- MVB communication with TCU is ok
- Control electronics contactor (218) is on
- CB monitoring1 (127.2/1) is on
- CB converter pump1 (63.1/1) is on
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 155/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Criteria:
- pressure sensor of traction converter 1 is broken
- coolant pressure of traction converter 1 is low and has to be adjusted

Reaction:
- Fault code triggered
- VCB opened
- Locomotive not operational

Related messages:
-

3.2.73 CCU Fault Code 0534


TC1: Coolant level Warning
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 156/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 0534

Diagnostic message only


for information.
Take Locomotive to the
shed for maintenance

End

Components concerned:
Component Device name CCU1 Device name CCU2
- - -

Condition:
- CCU must be master.

Criteria:
- coolant level drops to the considerably lower level.(Loco needs to be taken to the shed for
maintenance)

Reaction:
- Fault code triggered
- TC1 cut out request is initiated

Related messages:
-

3.2.74 CCU Fault Code 0535


TC1: Coolant level Alarm
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 157/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 535

Check coolant level at


(Coolant expansion tank)

Check the cooling water pipe for leakage


Yes
inside and outside of the converter 1
Coolant expansion
tank empty

No
Leakage found? No

Yes
Check/repair wiring to Expansion tank
sensor contact and CCU

Refill cooling water by using coolant


expansion tank.
Check/repair cooling water pipe.Refill
cooling water by using the coolant
expansion tank

Unground the high


voltage circuit and
close the MCB

End

Components concerned:
Component Device name CCU1 Device name CCU2
- - -

Condition:
- CCU must be master.

Criteria:
- coolant expansion tank is almost empty.(Loco needs to be taken to the shed for maintenance)

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 158/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Reaction:
- Fault code triggered
- VCB locked.
- Locomotive not operational.
- TC1 cut out request is initiated

Related messages:
-

3.2.75 CCU Fault Code 0536


TC1: Temp sensor Faulty
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 159/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 536

Check traction converter1


temperature sensors.

End

Components concerned:
Component Device name CCU1 Device name CCU2
Traction Converter 1 415/1 415/1

Condition:

Criteria:
- Communication to atleast on TCU is ok.
- Traction converter 1 temperation sensor is faulty.

Reaction:
- Fault code triggered

Related messages:
-

3.2.76 CCU Fault Code 0537


TC2: CoolBlower Failed

Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 160/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 00537

Close circuit breaker


59.1/2

CB trips again? Yes

Isolate connections to
No
59.1/2, pins

Message gone? No

Check operation of 59.1/1 CB trips again? No


auxiliary contacts

Yes
Check circuits connected to
Replace circuit CB contacts for short circuits
Check/repair wiring between IO module
Yes breaker (see circ. Diagram 05G).
E223_04 and 59.1/2
59.1/2
(see circ. Diagram 05G)

End

Components concerned:

Component Device name CCU1 Device name CCU2


CB to oil cooling blower 59.1/2 59.1/2
IO station 22 E223 E223
CB monitoring1 127.2/2 127.2/2

Condition:
- Atleast one aux converter is running and supplying to the loads.
- CB monitoring1 ok.
- CB to TC2 blower ok
- IO station 22 or module E223 is ok.

Criteria:
- CB of TC1 blower is opened.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 161/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- No signal from E223_04.

Reaction:
- Fault code triggered
- TC2 blower is inoperative
- TC2 cooling failed.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 162/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.77 CCU Fault Code 0538
TC2: WaterCirculation fault

Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 00538

Close circuit breaker


63.1/2

CB trips again? Yes

Isolate connections to
No
63.1/2, pins

Message gone? No

Check operation of 63.1/2 CB trips again? No


auxiliary contacts

Yes
Check circuits connected to
CB contacts for short circuits
(see circ. Diagram 05G).
Replace circuit
Yes Check/repair wiring between IO module breaker
E223_09 and 63.1/2 63.1/2
(see circ. Diagram 05G)

End

Components concerned:

Component Device name CCU1 Device name CCU2


CB OIL PUMP2 CONVERTER 63.1/2 63.1/2
IO station 12 E223 E223
CB monitoring1 127.2/2 127.2/2

Condition:
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 163/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Atleast one aux converter is running and supplying to the loads.
- CB monitoring1 ok.
- CB to oil pump2 converter ok
- IO station 22 or module E223 is ok.

Criteria:
- CB of TC2 water pump2 is opened.
- No signal from E223_09.

Reaction:
- Fault code triggered
- TC2 water pump2 is inoperative
- TC2 cooling failed.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 164/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.78 CCU Fault Code 0539

TC2: Coolant Pressure High


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 539

Check/repair Pressure sensor

Check/repair wiring from 218 to 127.2/2


(72V DC)(see circ. Diagram 05G)

Message still active? No

Yes

Check/repair wiring from Klip E223_09:


412.LA/10 to 63.1/2
63.1/2 to 127.2/2
(see circ. Diagram 05G)

End

Components concerned:
Component Device name CCU1 Device name CCU2
Traction converter 2 415/2 415/2

Condition:
- At least one Aux converter is running
- MVB communication with TCU is ok
- Control electronics contactor (218) is on
- CB monitoring1 (127.2/2) is on
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 165/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- CB converter pump1 (63.1/2) is on

Criteria:
- pressure sensor of traction converter 2 is broken
- coolant pressure of traction converter 2 is too high and has to be adjusted

Reaction:
- Fault code triggered
- VCB opened
- Locomotive not operational

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 166/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.79 CCU Fault Code 0540

TC2: Coolant Pressure Low


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 540

Check/repair pressure sensor

Check/repair wiring from 218 to 127.2/2


(72V DC)(see circ. Diagram 05G)

Message still active? No

Yes

Check/repair wiring from Klip E223_09:


412.LA/10 to 63.1/2
63.1/2 to 127.2/2
(see circ. Diagram 05G)

End

Components concerned:
Component Device name CCU1 Device name CCU2
Traction converter 2 415/2 415/2

Condition:
- At least one Aux converter is running
- MVB communication with TCU is ok
- Control electronics contactor (218) is on

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 167/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- CB monitoring1 (127.2/2) is on
- CB converter pump1 (63.1/2) is on

Criteria:
- Pressure sensor of traction converter 2 is broken or some fault is there.
- Coolant pressure of traction converter 2 is low and has to be adjusted

Reaction:
- Fault code triggered
- VCB opened
- Locomotive not operational

Related messages:
-

3.2.80 CCU Fault Code 0541


TC2: Coolant level Warning
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 0541

Diagnostic message only


for information.
Take Locomotive to the
shed for maintenance

End

Components concerned:
Component Device name CCU1 Device name CCU2
- - -

Condition:
- CCU must be master.

Criteria:
- coolant level drops to the considerably lower level.(Loco needs to be taken to the shed for
maintenance)

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 168/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Reaction:
- Fault code triggered
- TC2 cut out request is initiated

Related messages:
-

3.2.81 CCU Fault Code 0542


TC2: Coolant level Alarm
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 169/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 542

Check coolant level at


(Coolant expansion tank)

Check the cooling water pipe for leakage


Yes
inside and outside of the converter 2
Coolant expansion
tank empty?

No
Leakage found? No

Yes
Check/repair wiring to Expansion tank
sensor contact and CCU

Refill cooling water

Check/repair cooling water pipe. Refill


cooling water.

Unground the high


voltage circuit and
close the MCB

End

Components concerned:
Component Device name CCU1 Device name CCU2
- - -

Condition:
- CCU must be master.

Criteria:
- coolant expansion tank is almost empty.(Loco needs to be taken to the shed for maintenance)

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 170/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Reaction:
- Fault code triggered
- VCB locked.
- Locomotive not operational.
- TC2 cut out request is initiated

Related messages:
-

3.2.82 CCU Fault Code 0543


TC2: Temp sensor Faulty
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 171/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 543

Check traction converter2


temperature sensors.

End

Components concerned:
Component Device name CCU1 Device name CCU2
Traction Converter 2 415/2 415/2

Condition:

Criteria:
- Communication to atleast on TCU is ok.
- Traction converter 2 temperation sensor is faulty.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 172/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.83 CCU Fault Code 0545
Bogie 1: TM cooling blower failed

Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 00545

Close circuit breaker


53.1/1

CB trips again? Yes

Isolate connections to
No
53.1/1

Message gone? No

Check operation of 53.1/1 CB trips again? No


auxiliary contacts

Yes
Check circuits connected to
Replace circuit CB contacts for short circuits
Check/repair wiring between IO module
Yes breaker (see circ. Diagram 01M).
E212_06 and CB 53.1/1
53.1/1
(see circ. Diagram 05F)

End

Components concerned:

Component Device name CCU1 Device name CCU2


CB to TM blower 53.1/1 HB1 53.1/1 HB1
IO station 12 E122 E122
CB monitoring1 127.2/1 SB1 127.2/1 SB1

Condition:
- TM blowers are powered. (aux converter is running and supplying to the loads).

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 173/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- CB monitoring1 ok.1
- CB to TM blower ok 2
- IO station 12 or module E122 is ok. 3

Criteria:
- CB to TM is opened.
- No signal from E122_03.

Reaction:
- Fault code triggered
- TM blower is inoperative
- one bogie will get isolated and operation will continue with other bogie

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 174/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.84 CCU Fault Code 0546
Bogie 2: TM cooling blower failed
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 00546

Close circuit breaker


53.1/2

CB trips again? Yes

Isolate connections to
No
53.1/2

Message gone? No

Check operation of 53.1/2 CB trips again? No


auxiliary contacts

Yes
Check circuits connected to
CB contacts for short circuits
Check/repair wiring between IO Module (see circ. Diagram 01M).
Yes E_212_06 and CB 53.1/2 Replace circuit
(see circ. Diagram 05F) breaker
53.1/2

End

Components concerned:

Component Device name CCU1 Device name CCU2


CB to TM blower 53.1/2 53.1/2
IO station 21 E212 E212
CB monitoring1 127.2/2 SB1 127.2/2 SB1

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 175/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- TM blowers are powered. (aux converter is running and supplying to the loads).
- CB monitoring1 ok.
- CB to TM blower ok.
- IO station 21 or module E212 is ok.

Criteria:
- CB to TM is opened.
- No signal from E212_06.

Reaction:
- Fault code triggered
- TM blower is inoperative
- one bogie will get isolated and operation will continue with other bogie

Related messages:
-

3.2.85 CCU Fault Code 0550

Switch-on fault primary coupling contactor -Q01/Q02/Q03


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 176/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 0550

Check Output module pins A114_04 and A125_04.


Check whether Led of these output pins are on and
command to close Q01 is given.

Check wiring of output module


Command is not
A114 and A125 to its CB 127.9/1 and 127.9/2 resp.
given, LED on I/O No
Replace I/O module if no wiring issue is found.
output is on?

Yes

Check input module E117_00 and


E127_00,check respective LEDs of input
pins whether feedback is available or not.

Check wiring from I/O input E117_00


Feedback available, and E127_00 to Contactor Q01. Refix
No Wiring is ok? No
LEDs On? wires. Circuit diagram 05R.08. wiring.

Yes
Yes

Check Contactor Q01, it should be close.

Replace relay
Contactor Q01 close? No Q01.

Yes

End

Components concerned:
Component Device name CCU1 Device name CCU2
Contactor Q01 Q01
IO station 11 E117 E117
IO station 12 A125 A125

Condition:
- CB I/O signals (127.9) is on.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 177/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- PWIAUX1 or PWIAux2 is ready to operate.
- Aux contactor test is not active.

Criteria:
- Command to close the contactor Q01 is given, but feedback signal is not given or issue with the
I/O module E117_00, E127_00.

Reaction:
- Fault code triggered

Related messages:
-

3.2.86 CCU Fault Code 0551

Switch-off fault primary coupling contactor -Q01/Q02/Q0


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 178/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 0551

Check Output module pins A114_04 and A125_04.


Check whether Led of these output pins are off and
command to close Q01 is not given.

Check wiring of output module


Command is not
A114 and A125 to its CB 127.9/1 and 127.9/2 resp.
given, LED on I/O No
Replace I/O module if no wiring issue is found.
output is off?

Yes

Check input module E117_00 and


E127_00,check respective LEDs of input
pins whether feedback is available or not.

Check wiring from I/O input E117_00


and E127_00 to Contactor Q01. Refix
LEDs Off? No Wiring is ok? No
wires. Circuit diagram 05R.08. wiring.

Yes
Yes

Check Contactor Q01, it should be open.

Replace relay
Contactor Q01 open? No Q01.

Yes

End

Components concerned:
Component Device name CCU1 Device name CCU2
Contactor Q01 Q01
IO station 11 E117 E117
IO station 12 A125 A125

Condition:
- CB I/O signals (127.9) is on.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 179/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- PWIAUX1 or PWIAux2 is ready to operate.
- Aux contactor test is not active.

Criteria:
Command to open the contactor Q01 is given, but feedback signal is still available or issue with the
I/O module E117_00, E127_00.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 180/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.87 CCU Fault Code 0553

Switch-on fault AUX contactor -K01


Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0553

Check Output module pins A114_05 and A125_05.


Check whether Led of these output pins are on and
command to close K01 is given.

Check wiring of output module


Command is not
A114 and A125 to its CB 127.9/1 and 127.9/2 resp.
given, LED on I/O No
Replace I/O module if no wiring issue is found.
output is on?

Yes

Check input module E117_01 and


E127_01,check respective LEDs of input
pins whether feedback is available or not.

Check wiring from I/O input E117_01


Feedback available, and E127_01 to Contactor K01. Refix
No Wiring is ok? No
LEDs On? wires. Circuit diagram 05R.15. wiring.

Yes
Yes

Check Contactor K01, it should be close.

Replace relay
Contactor K01 close? No K01.

Yes

End

Components concerned:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 181/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Component Device name CCU1 Device name CCU2
Contactor K01 K01
IO station 11 E117 E117
IO station 12 A125 A125

Condition:
- CB I/O signals (127.9) is on.
- PWIAUX1 or PWIAux2 is ready to operate.
- Aux contactor test is not active.
- Q01 testing must be stopped.

Criteria:
- Command to close the contactor K01 is given, but feedback signal is not given or issue with the
I/O module E117_01, E127_01.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 182/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.88 CCU Fault Code 0554
Switch-off fault AUX contactor -K01
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0554

Check Output module pins A114_05 and A125_05.


Check whether Led of these output pins are off and
command to close K01 is not given.

Check wiring of output module


Command is not
A114 and A125 to its CB 127.9/1 and 127.9/2 resp.
given, LED on I/O No
Replace I/O module if no wiring issue is found.
output is off?

Yes

Check input module E117_01 and


E127_01,check respective LEDs of input
pins whether feedback is available or not.

Check wiring from I/O input E117_01


and E127_01 to Contactor K01. Refix
LEDs Off? No Wiring is ok? No
wires. Circuit diagram 05R.15. wiring.

Yes
Yes

Check Contactor K01, it should be open.

Replace relay
Contactor K01 open? No K01.

Yes

End

Components concerned:
Component Device name CCU1 Device name CCU2
Contactor K01 K01
IO station 11 E117 E117
IO station 12 A125 A125

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 183/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- CB I/O signals (127.9) is on.
- PWIAUX1 or PWIAux2 is ready to operate.
- Aux contactor test is not active.
- Q01 testing must be stopped.

Criteria:
Command to open the contactor K01 is given, but feedback signal is still available or issue with the
I/O module E117_01, E127_01.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 184/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.89 CCU Fault Code 0556
Switch-on fault AUX contactor -K02
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0556

Check Output module pins A114_06 and A125_06.


Check whether Led of these output pins are on and
command to close K02 is given.

Check wiring of output module


Command is not
A114 and A125 to its CB 127.9/1 and 127.9/2 resp.
given, LED on I/O No
Replace I/O module if no wiring issue is found.
output is on?

Yes

Check input module E117_02 and


E127_02,check respective LEDs of input
pins whether feedback is available or not.

Check wiring from I/O input E117_02


Feedback available, and E127_02 to Contactor K02. Refix
No Wiring is ok? No
LEDs On? wires. Circuit diagram 05S.08. wiring.

Yes
Yes

Check Contactor K02, it should be close.

Replace relay
Contactor K02 close? No K02.

Yes

End

Components concerned:
Component Device name CCU1 Device name CCU2
Contactor K02 K02
IO station 11 E117 E117
IO station 12 A125 A125

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 185/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- CB I/O signals (127.9) is on.
- PWIAUX1 or PWIAux2 is ready to operate.
- Aux contactor test is not active.
- K01 testing must be stopped.

Criteria:
- Command to close the contactor K02 is given, but feedback signal is not given or issue with the
I/O module E117_02, E127_02.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 186/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.90 CCU Fault Code 0557
Switch-off fault AUX contactor -K02
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0557

Check Output module pins A114_06 and A125_06.


Check whether Led of these output pins are off and
command to close K02 is not given.

Check wiring of output module


Command is not
A114 and A125 to its CB 127.9/1 and 127.9/2 resp.
given, LED on I/O No
Replace I/O module if no wiring issue is found.
output is off?

Yes

Check input module E117_02 and


E127_02,check respective LEDs of input
pins whether feedback is available or not.

Check wiring from I/O input E117_02


and E127_02 to Contactor K02. Refix
LEDs Off? No Wiring is ok? No
wires. Circuit diagram 05S.08. wiring.

Yes
Yes

Check Contactor K02, it should be open.

Replace relay
Contactor K02 open? No K02.

Yes

End

Components concerned:
Component Device name CCU1 Device name CCU2
Contactor K02 K02
IO station 11 E117 E117
IO station 12 A125 A125

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 187/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- CB I/O signals (127.9) is on.
- PWIAUX1 or PWIAux2 is ready to operate.
- Aux contactor test is not active.
- K01 testing must be stopped.

Criteria:
Command to open the contactor K02 is given, but feedback signal is still available or issue with the
I/O module E117_02, E127_02.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 188/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.91 CCU Fault Code 0560
Switch-on fault secondary coupling contactor -K03
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0560

Check Output module pins A114_07 and A125_07.


Check whether Led of these output pins are ON and
command to close K03 is given.

Check wiring of output module


Command is
A114 and A125 to its CB 127.9/1 and 127.9/2 resp.
given, LED on I/O No
Replace I/O module if no wiring issue is found.
output is On?

Yes

Check input module E117_03 and


E127_03,check respective LEDs of input
pins whether feedback is available or not.

Check wiring from I/O input E117_03


Feedback available, and E127_03 to Contactor K03. Refix
No Wiring is ok? No
LEDs On? wires. Circuit diagram 05S.15. wiring.

Yes
Yes

Check Contactor K03, it should be Close.

Replace relay
Contactor K03 Close? No K03.

Yes

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 189/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
Contactor K03 K03
IO station 11 E117 E117
IO station 12 A125 A125

Condition:
- CB I/O signals (127.9) is on.
- PWIAUX1 or PWIAux2 is ready to operate.
- Aux contactor test is not active.
- K02 testing must be stopped.

Criteria:
- Command to close the contactor K03 is given, but feedback signal is not given or issue with the
I/O module E117_03, E127_03.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 190/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.92 CCU Fault Code 0561
Switch-off fault secondary coupling contactor -K03
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0561

Check Output module pins A114_07 and A125_07.


Check whether Led of these output pins are off and
command to close K03 is not given.

Check wiring of output module


Command is not
A114 and A125 to its CB 127.9/1 and 127.9/2 resp.
given, LED on I/O No
Replace I/O module if no wiring issue is found.
output is off?

Yes

Check input module E117_03 and


E127_03,check respective LEDs of input
pins whether feedback is available or not.

Check wiring from I/O input E117_03


and E127_03 to Contactor K03. Refix
LEDs Off? No Wiring is ok? No
wires. Circuit diagram 05S.15. wiring.

Yes
Yes

Check Contactor K03, it should be open.

Replace relay
Contactor K03 open? No K03.

Yes

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 191/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
Contactor K03 K03
IO station 11 E117 E117
IO station 12 A125 A125

Condition:
- CB I/O of IO stations (127.9) is on.
- PWIAUX1 or PWIAux2 is ready to operate.
- Aux contactor test is not active.
- K02 testing must be stopped.

Criteria:
Command to open the contactor K03 is given, but feedback signal is still available or issue with the
I/O module E117_03, E127_03.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 192/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.93 CCU Fault Code 0570
Reserved for AUX_INT
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0570

Check LED of Input module pin E122_00 in IO station


12.

IO module is healthy so check wiring between Io


Is LED OFF? No
module and controller

Yes

Check Fuse auxiliary 41.


See circuit diagram 05F.

Is fuse ok? No Change the fuse

Yes

Check CB 127.2/1 and wiring between CB and


fuse.

Is CB ok? No Change CB

Yes

Change wiring of IO module and if necessary


replace IO module

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 193/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
CCU
IO station 12 E122 E122
Fuse auxiliary 41 41

Condition:
- CCU must be master

Criteria:
- Fuse status is not available on digital input E122_00. Either fuse blown out or there is something
wrong with IO Module.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 194/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.94 CCU Fault Code 0571
AUX1: permanent fault
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 00571

AUX1 is cut out because of a permanent failure. The diagnostic code is for information only. The
cause of the total failure is diagnosed in other diagnostic codes.

Check CCU and TCU diagnostic storage for the cause of the total failure. Follow instructions of
that code(s).

End

Components concerned:
Component Device name CCU1 Device name CCU2
- AUX1 inverter 1050.1 1050.1

Condition:
No special condition

Criteria:
The AUX detects a serious fault, where a operation is no longer possible.
Fault can be detected during operation, at component test or at tests during start up of the AUX
Reasons can be for example: fault of a IGBT-Module, high temperature, current values are
exceeding limits, supervision of the internal control, ground fault.

Reaction:
- Fault code triggered
- AUX1 is cut out
- Display indication shows "AUX1 fault"

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 195/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.95 CCU Fault Code 0572
AUX2: permanent fault
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 00572

AUX2 is cut out because of a permanent failure. The diagnostic code is for information only. The
cause of the total failure is diagnosed in other diagnostic codes.

Check CCU and TCU diagnostic storage for the cause of the total failure. Follow instructions of
that code(s).

End

Components concerned:
Component Device name CCU1 Device name CCU2
- AUX2 inverter 1050.2 1050.2

Condition:
No special condition

Criteria:
The AUX detects a serious fault, where a operation is no longer possible.
Fault can be detected during operation, at component test or at tests during start up of the AUX
Reasons can be for example: fault of a IGBT-Module, high temperature, current values are
exceeding limits, supervision of the internal control, ground fault.

Reaction:
- Fault code triggered
- AUX2 is cut out
- Display indication shows "AUX2 fault"

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 196/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.96 CCU Fault Code 0573
AUX1: Temporary Error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 00573

AUX1 is in redundancy mode. The diagnostic code is for information only. The cause of the
redundancy mode is diagnosed in other diagnostic codes.

Check CCU and TCU diagnostic storage for the cause of the redundancy mode. Follow
instructions of that code(s).

End

Components concerned:
Component Device name CCU1 Device name CCU2
- AUX1 inverter 1050.1 1050.1

Condition:
See fault code, which lead to the redundancy mode.

Criteria:
AUX1 is in redundancy mode. The fault code is for information only. The cause of the redundancy
mode is diagnosed in other fault codes.

Reaction:
Redundancy mode of AUX1 Inverter. AUX2 is cut out

Related messages:
-

3.2.97 CCU Fault Code 0574


AUX2: Temporary Error
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 197/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 00574

AUX2 is in redundancy mode. The diagnostic code is for information only. The cause of the
redundancy mode is diagnosed in other diagnostic codes.

Check CCU and TCU diagnostic storage for the cause of the redundancy mode. Follow
instructions of that code(s).

End

Components concerned:
Component Device name CCU1 Device name CCU2
- AUX2 inverter 1050.2 1050.2

Condition:
See fault code, which lead to the redundancy mode.

Criteria:
AUX2 is in redundancy mode. The fault code is for information only. The cause of the redundancy
mode is diagnosed in other fault codes.

Reaction:
Redundancy mode of AUX2 Inverter. AUX1 is cut out

Related messages:
-

3.2.98 CCU Fault Code 0582


AUX1: Load_shedding_Load_reduction
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 198/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
- AUX1 is On/Active.
- AUX should not be in redundant mode with 1 transformer active.

Criteria:
- Aux1 load shedding or load reduction request is generated when there is some issue with inverter
of AUX converter 1 eg. IGBT junction temperature high or AUX is not delivering required output to
the load. The only possible immediate short-term remedy is a reduction in power or disconnection.
In the longer term, it is necessary to investigate whether the cooling system is functioning correctly.

Reaction:
- Fault code triggered

Related messages:
FC_0583

3.2.99 CCU Fault Code 0583


AUX2: Load_shedding_Load_reduction
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 199/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
- AUX2 is On/Active.
- AUX should not be in redundant mode with 1 transformer active.

Criteria:
- Aux2 load shedding or load reduction request is generated when there is some issue with inverter
of AUX converter 2 eg. IGBT junction temperature high or AUX is not delivering required output to
the load. The only possible immediate short-term remedy is a reduction in power or disconnection.
In the longer term, it is necessary to investigate whether the cooling system is functioning correctly.

Reaction:
- Fault code triggered

Related messages:
FC_0582

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 200/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.100 CCU Fault Code 0594
Current / voltage limitation AUX1 is active
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:

Criteria:
- AUX1 detects an overload or short circuit at its output for minimum of 3s.
- The AUX1 limits the output current, by lowering of the output voltage with constant frequency.

Reaction:
- Fault code triggered

Related messages:
FC_0595

3.2.101 CCU Fault Code 0595


Current / voltage limitation AUX2 is active
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 201/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:

Criteria:
- AUX2 detects an overload or short circuit at its output for minimum of 3s.
- The AUX2 limits the output current, by lowering of the output voltage with constant frequency.

Reaction:
- Fault code triggered

Related messages:
FC_0594

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 202/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.102 CCU Fault Code 0597
AUX1 degrouped due to current/voltage limitation
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:

Criteria:
- This diagnostic entry is for information only. The TCU1 or the CCU (loop from CCU to TCU an
TCU to CCU) has generated a cut out request because of a protective reaction or a detected fault.
The fault or protective reaction is stored in a separate diagnostic entry in TCU or CCU storage.
Issues can be for example C-filter fault, detected ground fault, permanent fault of AUX,
frequency/voltage/current limitation.

Reaction:
- Fault code triggered

Related messages:
FC_0598

3.2.103 CCU Fault Code 0598


AUX2 degrouped due to current/voltage limitation
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 203/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:

Criteria:
- This diagnostic entry is for information only. The TCU2 or the CCU (loop from CCU to TCU an
TCU to CCU) has generated a cut out request because of a protective reaction or a detected fault.
The fault or protective reaction is stored in a separate diagnostic entry in TCU or CCU storage.
Issues can be for example C-filter fault, detected ground fault, permanent fault of AUX,
frequency/voltage/current limitation.

Reaction:
- Fault code triggered

Related messages:
FC_0597

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 204/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.104 CCU Fault Code 0600
total failure AUX inverters
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
- CCU is master.
- AUX1 and AUX2 are not available.
- TCU1 and TCU2 off.

Criteria:
- Both HEPs are cut out. The fault code is for information only. The cause of the total failure is
diagnosed in other fault codes.

Reaction:
- Fault code triggered

Related messages:

3.2.105 CCU Fault Code 0603


AUX1 degrouped due to faulty filter capacitor (BRAM)
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 205/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:
- Loco type WAP7.

Criteria:
- The AUX supervises with the help of the voltage transducers the ripple of the output value. If the
ripple is to high, a fault of the filter capacitors is detected.
- Fault is triggered in BRAM and this fault will remain locked until BRAM is resetted using SIBAS
monitor tool.

Reaction:
- Fault code triggered

Related messages:

3.2.106 CCU Fault Code 0604


AUX2 degrouped due to faulty filter capacitor (BRAM)
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 206/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:
- Loco type WAP7.

Criteria:
- The AUX supervises with the help of the voltage transducers the ripple of the output value. If the
ripple is to high, a fault of the filter capacitors is detected.
- Fault is triggered in BRAM and this fault will remain locked until BRAM is resetted using SIBAS
monitor tool.

Reaction:
- Fault code triggered

Related messages:

3.2.107 CCU Fault Code 0606


Ground fault detected AUX1
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 207/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
-

Criteria:
The AUX1 detects an internal grounding fault/isolation fault inside his cubicle or the wiring behind.
In general the earth fault detection is reliable.
Following reasons could be:
- missing earth strap
- not full/complete missing mounting of the shield of a cable
- humidity (e.g. contact of shielding with the wire).
- connections not tightened enough
- serious fault of one of the components of the AUX (one of the components scorched)

Reaction:
- Fault code triggered
- AUX1 is switched off, AUX2 is in redundancy mode

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 208/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.108 CCU Fault Code 0607
Ground fault detected AUX2
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
-

Criteria:
The AUX2 detects an internal grounding fault/isolation fault inside his cubicle or the wiring behind.
In general the earth fault detection is reliable.
Following reasons could be:
- missing earth strap
- not full/complete missing mounting of the shield of a cable
- humidity (e.g. contact of shielding with the wire).
- connections not tightened enough
- serious fault of one of the components of the AUX (one of the components scorched)

Reaction:
- Fault code triggered
- AUX2 is switched off, AUX1 is in redundancy mode

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 209/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.109 CCU Fault Code 0610
Switch-off fault AUX disconnector 1
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
-

Criteria:
- In case of AUX modules isolation from DC link due to any fault there is fault is disconnector.
Disconnecting contactor might get stuck or not receiving signal so check that contactor.
Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 210/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.110 CCU Fault Code 0611
Switch-off fault AUX disconnector 2
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
-

Criteria:
- In case of AUX modules isolation from DC link due to any fault there is fault is disconnector.
Disconnecting contactor might get stuck or not receiving signal so check that contactor.
Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 211/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.111 CCU Fault Code 0621
Failure voltage transformer AUX1 detected (BRAM)
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
- CCU is master.

Criteria:
- CB F03 is off.
- There is no signal from voltage transformer or the voltage value detected by it is not valid. Check
voltage transformer or is connections. Fault is triggered in BRAM so can be resetted by SIBAS
monitor tool.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 212/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.112 CCU Fault Code 0622
Failure voltage transformer AUX2 detected (BRAM)
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
- CCU is master.

Criteria:
- CB F04 is off.
- There is no signal from voltage transformer or the voltage value detected by it is not valid. Check
voltage transformer or is connections. Fault is triggered in BRAM so can be resetted by SIBAS
monitor tool.

Reaction:
- Fault code triggered

Related messages:

3.2.113 CCU Fault Code 0631


ACU 1: Overcurrent detected
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 213/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0631

Check for the following reasons:


1. Check current sensor.
2. Check/repair connection cables between
AUX1 and loads connected to it.
3. Check/repair all loads connected to AUX1 for
short circuit .
4. Check/repair/replace water/oil cooler blower 1
& 2 and TM scavenge blower 1&2.

End

Components concerned:
Component Device name CCU1 Device name CCU2
Aux1 1050.1 1050.1

Condition:
- ACU1 communication ok.

Criteria:
- Aux1 output current is greater than equal to 400A for more than 100ms.

Reaction:
- Fault code triggered

Related messages:
-

3.2.114 CCU Fault Code 0632


ACU 2: Overcurrent detected
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 214/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0632

Check for the following reasons:


1. Check current sensor.
2. Check/repair connection cables between
AUX1 and loads connected to it.
3. Check/repair all loads connected to AUX2 for
short circuit .
4. Check/repair/replace TM blower, oil cooler
blower 1 & 2.
5. Check/repair/replace Battery charger circuit.

End

Components concerned:
Component Device name CCU1 Device name CCU2
Aux2 1050.2 1050.2

Condition:
- ACU2 communication ok.

Criteria:
- Aux2 output current is greater than equal to 400A for more than 100ms.

Reaction:
- Fault code triggered
- VCB off

Related messages:
-
3.2.115 CCU Fault Code 0633
ACU 3: Overcurrent detected
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 215/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0633

Check for the following reasons:


1. Check current sensor.
2. Check/repair connection cables between
AUX1 and loads connected to it.
3. Check/repair all loads connected to AUX3 for
short circuit .
4. Check/repair/replace oil pump converter/
transformer 1 & 2, Compressor 1&2.
5. Check/repair/replace Battery charger circuit.

End

Components concerned:
Component Device name CCU1 Device name CCU2
Aux3 1050.2 1050.2

Condition:
- ACU3 communication ok.

Criteria:
- Aux3 output current is greater than equal to 400A for more than 100ms.

Reaction:
- Fault code triggered
- VCB off

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 216/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.116 CCU Fault Code 0700
ACU1: detected Aux cont 52/4 dropout error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Note: In WAG9, contactor 52/4 is always energized.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 217/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 0700

Check CB 127.22/1 and 218. Switch on again.

Code still active? No

Yes

Check contactor 52.3/4. It should be open.

Check wiring between contactor 52.3 /4_A1 to 50.X2_11


Is contactor open? No AUX1.
52.3 /4_A2 to 50.X2_10 AUX1.

Yes

Check/Repair contactor 52/4.


Check/Repair/Replace wiring between contactor
52/4_A2 & 52.3 /4_+1.
52/4_A1 to (52/1_72 & 52/5_61).
(52/1_71 & 52/5_62) to CB 127.22/1
Connection between contactor 52/4_54 to
50.X2_9 Aux1 and 52/4_53 to 50.X2_11 Aux1

Fault gone? Yes

No

Replace faulty Contactor.

End

Components concerned:
Component Device name CCU1 Device name CCU2
- Auxiliary contactor ACU1 52/4 52/4

Condition:
- Aux1 contactor 52/4 On command is not given.
- AUX Contactor test active

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 218/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- VCB off.
- CB Aux Contactor ON
- ACU1 to CCU master MVB communication is OK.
- AUX3_Contactor 52/3 test has quit.

Criteria:
- Contactor 52/4 on comand is not given by CCU to ACU1 still feedback is available in Aux1 from
contactor 52/4 for 1s or longer. That means contactor is still closed.

Reaction:
- Fault code triggered
-

Related messages:
FC 00701

3.2.117 CCU Fault Code 0701


ACU1: detected Aux cont 52/4 pickup error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 219/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Note: In WAG9, contactor 52/4 is always energized.
Troubleshooting:
Code = 0701

Check CB 127.22/1 and 218. Switch on again.

Code still active? No

Yes

Check contactor 52.3/4. It should be closed.

Check wiring between contactor 52.3 /4_A1 to 50.X2_11


Is contactor closed? No AUX1.
52.3 /4_A2 to 50.X2_10 AUX1

Yes

Check/Repair contactor 52/4.


Check/Repair/Replace wiring between contactor
52/4_A2 & 52.3 /4_+1.
52/4_A1 to (52/1_72 & 52/5_61).
(52/1_71 & 52/5_62) to CB 127.22/1
Connection between contactor 52/4_54 to
50.X2_9 Aux1 and 52/4_53 to 50.X2_11 Aux1

Fault gone? Yes

No

Replace faulty Contactor.

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 220/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
- Auxiliary contactor ACU1 52/4 52/4

Condition:
- AUX1 contactor 52/4 On command is given.
- AUX Contactor test is not active
- VCB on.
- CB AUX Contactor ON
- ACU1 to CCU master MVB communication is OK.
- AUX3_Contactor 52/3 test has quit.

Criteria:
- Contactor 52/4 ON comand is given by CCU to ACU1 still feedback is not available in AUX1 from
contactor 52/4 for 1s or longer. That means contactor is still opened.

Reaction:
- Fault code triggered
-

Related messages:
FC 00700

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 221/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 222/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.118 CCU Fault Code 0702
ACU1: detected Aux cont 52/5 dropout error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Note: In WAG9, contactor 52/5 is NOT USED.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 223/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 0702

Check CB 127.22/1 and 218. Switch on again.

Code still active? No

Yes

Check contactor 52.3/5. It should be open.

Check wiring between contactor 52.3 /5_A1 to 50.X2_12


Is contactor open? No AUX1.
52.3 /5_A2 to 50.X2_7 AUX1.

Yes

Check/Repair contactor 52/5.


Check/Repair/Replace wiring of contactor 52/
5_A2 to 52.3 /5_+1.
52/5_A1 to (52/1_62& 52/4_71).
(52/1_61 & 52/4_72) to CB 127.22/1
Connection between contactor 52/5_54 to
50.X2_8 Aux1 and 52/5_53 to 50.X2_12 Aux1

Fault gone? Yes

No

Replace faulty Contactor.

End

Components concerned:
Component Device name CCU1 Device name CCU2
- Auxiliary contactor ACU1 52/5 52/5

Condition:
- Aux1 contactor 52/5 On command is not given.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 224/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- AUX Contactor test active
- VCB off.
- CB Aux Contactor ON
- ACU1 to CCU master MVB communication is OK.
- AUX2_Contactor 52/4 test has quit.

Criteria:
- Contactor 52/5 ON comand is not given by CCU to ACU1 still feedback is available in Aux1 from
contactor 52/5 for 1s or longer. That means contactor is still closed.

Reaction:
- Fault code triggered
-

Related messages:
FC 00703

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 225/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.119 CCU Fault Code 0703
ACU1: detected Aux cont 52/5 pickup error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Note: In WAG9, contactor 52/5 is NOT USED.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 226/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 0703

Check CB 127.22/1 and 218. Switch on again.

Code still active? No

Yes

Check contactor 52.3/5. It should be close.

Check wiring between contactor 52.3 /5_A1 to 50.X2_12


Is contactor close? No AUX1.
52.3 /5_A2 to 50.X2_7 AUX1.

Yes

Check/Repair contactor 52/5.


Check/Repair/Replace wiring of contactor 52/
5_A2 to 52.3 /5_+1.
52/5_A1 to (52/1_62& 52/4_71).
(52/1_61 & 52/4_72) to CB 127.22/1
Connection between contactor 52/5_54 to
50.X2_8 Aux1 and 52/5_53 to 50.X2_12 Aux1

Fault gone? Yes

No

Replace faulty Contactor.

End

Components concerned:
Component Device name CCU1 Device name CCU2
- Auxiliary contactor ACU1 52/5 52/5

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 227/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- Aux1 contactor 52/5 On command is given.
- AUX Contactor test not active.
- VCB ON.
- CB Aux Contactor ON.
- ACU1 to CCU master MVB communication is OK.
- AUX2_Contactor 52/4 test has quit.

Criteria:
- Contactor 52/5 ON comand is given by CCU to ACU1 still feedback is not available in Aux1 from
contactor 52/5 for 1s or longer. That means contactor is still open.

Reaction:
- Fault code triggered
-

Related messages:
FC 00702

3.2.120 CCU Fault Code 0704


ACU2: detected Aux cont 52/1 dropout error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 228/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Note: In WAG9, contactor 52/1 is always deenergized.
Troubleshooting:
Code = 0704

Check CB 127.22/2 and 218. Switch on again.

Code still active? No

Yes

Check contactor 52.3/1. It should be open.

Check wiring between contactor 52.3 /1_A1 to 50.X3_23


Is contactor open? No AUX2.
52.3 /1_A2 to pin 25 ACU2.

Yes

Check/Repair contactor 52/1.


Check/Repair/Replace wiring of contactor 52/
1_A2 to 52.3 /1_+1.
52/1_A1 to 52/2_72.
52/2_71 to 50.X3_26 AUX2
Connection between contactor 52/1_54 to pin 4
of ACU2 and 52/1_53 to 50.X3_23 AUX2.

Fault gone? Yes

No

Replace faulty Contactor.

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 229/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
- Auxiliary contactor ACU2 52/1 52/1

Condition:
- Aux2 contactor 52/1 On command is not given.
- AUX Contactor test active
- VCB off.
- CB Aux Contactor ON
- ACU2 to CCU master MVB communication is OK.

Criteria:
- Contactor 52/1 ON comand is not given by CCU to ACU2 still feedback is available in Aux2 from
contactor 52/1 for 1s or longer. That means contactor is still closed.

Reaction:
- Fault code triggered

Related messages:
FC 00705

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 230/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.121 CCU Fault Code 0705
ACU2: detected Aux cont 52/1 pickup error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Note: In WAG9, contactor 52/1 is always deenergized.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 231/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 0705

Check CB 127.22/2 and 218. Switch on again.

Code still active? No

Yes

Check contactor 52.3/1. It should be closed.

Check wiring between contactor 52.3 /1_A1 to 50.X3_23


Is contactor closed? No AUX2.
52.3 /1_A2 to pin 25 ACU2.

Yes

Check/Repair contactor 52/1.


Check/Repair/Replace wiring of contactor 52/
1_A2 to 52.3 /1_+1.
52/1_A1 to 52/2_72.
52/2_71 to 50.X3_26 AUX2
Connection between contactor 52/1_54 to pin 4
of ACU2 and 52/1_53 to 50.X3_23 AUX2.

Fault gone? Yes

No

Replace faulty Contactor.

End

Components concerned:
Component Device name CCU1 Device name CCU2
- Auxiliary contactor ACU2 52/1 52/1

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 232/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- Aux2 contactor 52/1 On command is given.
- AUX Contactor test not active.
- VCB ON.
- CB Aux Contactor ON.
- ACU2 to CCU master MVB communication is OK.

Criteria:
- Contactor 52/1 ON comand is given by CCU to ACU2 still feedback is not available in Aux2 from
contactor 52/1 for 1s or longer. That means contactor is still open.

Reaction:
- Fault code triggered

Related messages:
FC 00704

3.2.122 CCU Fault Code 0706


ACU2: detected Aux cont 52/2 dropout error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 233/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Note: In WAG9, contactor 52/2 is always energized.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 234/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0706

Check CB 127.22/2 and 218. Switch on again.

Code still active? No

Yes

Check contactor 52.3/2. It should be opened.

Check wiring between contactor 52.3 /2_A1 to 50.X3_23


Is contactor open? No AUX2.
52.3 /2_A2 to pin 24 ACU2.

Yes

Check/Repair contactor 52/2.


Check/Repair/Replace wiring of contactor 52/
2_A2 to 52.3 /2_+1.
52.3/2_-2 to 52/1_81, 52/1_82 to 52/3_61.
52/2_A1 to 50.X3_29 AXU2 to CB 127.22/2.
52/2_53 to 50.X3_23 AUX2.
52/2_54 to 50.X3_16 AUX2.
Connection between contactor 52/2_54 to pin 4
of ACU2 and 52/2_53 to 50.X3_23 AUX2.

Fault gone? Yes

No

Replace faulty Contactor.

End

Components concerned:
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 235/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Component Device name CCU1 Device name CCU2
- Auxiliary contactor ACU2 52/2 52/2

Condition:
- Aux2 contactor 52/2 On command is not given.
- AUX Contactor test active.
- VCB off.
- CB Aux Contactor ON
- ACU2 to CCU master MVB communication is OK.
- AUX2 contactor 52/1 test quit.

Criteria:
- Contactor 52/2 ON comand is not given by CCU to ACU2 still feedback is available in Aux2 from
contactor 52/2 for 1s or longer. That means contactor is still closed.

Reaction:
- Fault code triggered

Related messages:
FC 00707

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 236/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.123 CCU Fault Code 0707
ACU2: detected Aux cont 52/2 pickup error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Note: In WAG9, contactor 52/2 is always energized.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 237/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0707

Check CB 127.22/2 and 218. Switch on again.

Code still active? No

Yes

Check contactor 52.3/2. It should be close.

Check wiring between contactor 52.3 /2_A1 to 50.X3_23


Is contactor close? No AUX2.
52.3 /2_A2 to pin 24 ACU2.

Yes

Check/Repair contactor 52/2.


Check/Repair/Replace wiring of contactor 52/
2_A2 to 52.3 /2_+1.
52.3/2_-2 to 52/1_81, 52/1_82 to 52/3_61.
52/2_A1 to 50.X3_29 AXU2 to CB 127.22/2.
52/2_53 to 50.X3_23 AUX2.
52/2_54 to 50.X3_16 AUX2.
Connection between contactor 52/2_54 to pin 4
of ACU2 and 52/2_53 to 50.X3_23 AUX2.

Fault gone? Yes

No

Replace faulty Contactor.

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 238/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
- Auxiliary contactor ACU2 52/2 52/2

Condition:
- Aux2 contactor 52/2 On command is given.
- AUX Contactor test not active.
- VCB ON.
- CB Aux Contactor ON.
- ACU2 to CCU master MVB communication is OK.
- AUX2 contactor 52/1 test quit.

Criteria:
- Contactor 52/2 ON comand is given by CCU to ACU2 still feedback is not available in Aux2 from
contactor 52/2 for 1s or longer. That means contactor is still open.

Reaction:
- Fault code triggered

Related messages:
FC 00706

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 239/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.124 CCU Fault Code 0708
ACU2: detected Aux cont 52/4 dropout error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Note: In WAG9, contactor 52/4 is always energized.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 240/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 0708

Check CB 127.22/2 and 218. Switch on again.

Code still active? No

Yes

Check contactor 52.3/4. It should be open.

Check wiring between contactor 52.3 /4_A1 to 50.X2_22


Is contactor open? No AUX1.
52.3 /4_A2 to 50.X3_31 AUX2.

Yes

Check/Repair contactor 52/4.


Check/Repair/Replace wiring between contactor
52/4_A2 & 52.3 /4_+1.
52/4_A1 to (52/1_72 & 52/5_61).
(52/1_71 & 52/5_62) to CB 127.22/1
Connection between contactor 52/4_54 to
50.X3_21 Aux2 and 52/4_53 to 50.X3_22 Aux2

Fault gone? Yes

No

Replace faulty Contactor.

End

Components concerned:
Component Device name CCU1 Device name CCU2
- Auxiliary contactor ACU2 52/4 52/4

Condition:
- Aux2 contactor 52/4 On command is not given.
- AUX Contactor test active

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 241/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- VCB off.
- CB Aux Contactor ON
- ACU2 to CCU master MVB communication is OK.
- AUX1_Contactor 52/4 test has quit.

Criteria:
- Contactor 52/4 on comand is not given by CCU to ACU2 still feedback is available in AUX2 from
contactor 52/4 for 1s or longer. That means contactor is still closed.

Reaction:
- Fault code triggered
-

Related messages:
FC 00709

3.2.125 CCU Fault Code 0709


ACU2: detected Aux cont 52/4 pickup error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 242/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Note: In WAG9, contactor 52/4 is always energized.
Troubleshooting:
Code = 0709

Check CB 127.22/2 and 218. Switch on again.

Code still active? No

Yes

Check contactor 52.3/4. It should be close.

Check wiring between contactor 52.3 /4_A1 to 50.X2_22


Is contactor close? No AUX1.
52.3 /4_A2 to 50.X3_31 AUX2.

Yes

Check/Repair contactor 52/4.


Check/Repair/Replace wiring between contactor
52/4_A2 & 52.3 /4_+1.
52/4_A1 to (52/1_72 & 52/5_61).
(52/1_71 & 52/5_62) to CB 127.22/1
Connection between contactor 52/4_54 to
50.X3_21 Aux2 and 52/4_53 to 50.X3_22 Aux2

Fault gone? Yes

No

Replace faulty Contactor.

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 243/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
- Auxiliary contactor ACU2 52/4 52/4

Condition:
- AUX2 contactor 52/4 On command is given.
- AUX Contactor test not active
- VCB ON.
- CB Aux Contactor ON.
- ACU2 to CCU master MVB communication is OK.
- AUX1_Contactor 52/4 test has quit.

Criteria:
- Contactor 52/4 on comand is given by CCU to ACU2 still feedback is not available in AUX2 from
contactor 52/4 for 1s or longer. That means contactor is still open.

Reaction:
- Fault code triggered
-

Related messages:
FC 00708

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 244/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.126 CCU Fault Code 0710
ACU3: detected Aux cont 52/3 dropout error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Note: In WAG9, contactor 52/3 is always deenergized.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 245/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 0710

Check CB 127.22/3 and 218. Switch on again.

Code still active? No

Yes

Check contactor 52.3/3. It should be close.

Check wiring between contactor 52.3 /3_A1 to 50.X3_06


Is contactor close? No AUX3.
52.3 /3_A2 to pin 25 of ACU3.

Yes

Check/Repair contactor 52/3.


Check/Repair/Replace wiring between contactor
52/3_A2 & 52.3 /3_+1, 52.3/3_-2 to 52/2_61.
52/3_A1 to 50.X3_11 AUX3.
(50.X3_11) AUX3 to CB 127.22/3
Connection between contactor 52/3_54 to
50.X3_04 AUX3 and 52/3_53 to 50.X3_06
AUX3

Fault gone? Yes

No

Replace faulty Contactor.

End

Components concerned:
Component Device name CCU1 Device name CCU2
- Auxiliary contactor ACU3 52/3 52/3

Condition:
- AUX3 contactor 52/3 On command is not given.
- AUX Contactor test active

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 246/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- VCB off.
- CB Aux Contactor ON
- ACU3 to CCU master MVB communication is OK.
- AUX2_Contactor 52/2 test has quit.

Criteria:
- Contactor 52/3 on comand is not given by CCU to ACU3 still feedback is available in AUX3 from
contactor 52/3 for 1s or longer. That means contactor is still closed.

Reaction:
- Fault code triggered
-

Related messages:
FC 00711

3.2.127 CCU Fault Code 0711


ACU3: detected Aux cont 52/3 pickup error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 247/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Note: In WAG9, contactor 52/3 is always deenergized.
Troubleshooting:
Code = 0711

Check CB 127.22/3 and 218. Switch on again.

Code still active? No

Yes

Check contactor 52.3/3. It should be open.

Check wiring between contactor 52.3 /3_A1 to 50.X3_06


Is contactor open? No AUX3.
52.3 /3_A2 to pin 25 of ACU3.

Yes

Check/Repair contactor 52/3.


Check/Repair/Replace wiring between contactor
52/3_A2 & 52.3 /3_+1, 52.3/3_-2 to 52/2_61.
52/3_A1 to 50.X3_11 AUX3.
(50.X3_11) AUX3 to CB 127.22/3
Connection between contactor 52/3_54 to
50.X3_04 AUX3 and 52/3_53 to 50.X3_06
AUX3

Fault gone? Yes

No

Replace faulty Contactor.

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 248/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
- Auxiliary contactor ACU3 52/3 52/3

Condition:
- AUX3 contactor 52/3 On command is given.
- AUX Contactor test not active.
- VCB ON.
- CB Aux Contactor ON.
- ACU3 to CCU master MVB communication is OK.
- AUX2_Contactor 52/2 test has quit.

Criteria:
- Contactor 52/3 on comand is given by CCU to ACU3 still feedback is not available in AUX3 from
contactor 52/3 for 1s or longer. That means contactor is still closed.

Reaction:
- Fault code triggered
-

Related messages:
FC 00710

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 249/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.128 CCU Fault Code 0836
Earth fault AUX2 consumers
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 250/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0836

Close circuit
breaker F01.

CB trips again? Yes

No
Isolate connections to
F01

Message gone? No

Check operation of F01


auxiliary contacts (pins 21/22).
CB trips again? No

Yes
Check/repair wiring to clip E117 & E127: Check circuits connected to
F01.21 to 1050.2_X5.11 CB contacts for short circuits .
Yes
1050.2_X5.11 to 411.RA/5
411.RA/5 to E117_04 &E127_04.
Replace circuit
F01.22 to PST02.
breaker F01.

End

Components concerned:
Component Device name CCU1 Device name CCU2
CB F01 F01
IO station 11 E117 E117
IO station 12 E127 E127
AUX Cubical 1050.2 1050.2

Condition:
- MVB communication with IO is ok.

Criteria:
- CB F01 off.
- No feedback signal from CB F01 available at digital input E117_04 and E127_04.

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 251/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Related messages:
-

3.2.129 CCU Fault Code 0837


Earth fault AUX1 consumers
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 252/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0837

Close circuit
breaker F02.

CB trips again? Yes

No
Isolate connections to
F02

Message gone? No

Check operation of F02


auxiliary contacts (pins 21/22).
CB trips again? No

Yes
Check/repair wiring to clip E117 & E127: Check circuits connected to
F02.21 to 1050.2_X5.12 CB contacts for short circuits .
Yes
1050.2_X5.12 to 411.RA/6
411.RA/6 to E117_05 &E127_05.
Replace circuit
F02.22 to PST02.
breaker F02.

End

Components concerned:
Component Device name CCU1 Device name CCU2
CB F02 F02
IO station 11 E117 E117
IO station 12 E127 E127
AUX Cubical 1050.2 1050.2

Condition:
- MVB communication with IO is ok.

Criteria:
- CB F02 off.
- No feedback signal from CB F02 available at digital input E117_05 and E127_05.

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 253/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Related messages:
-

3.2.130 CCU Fault Code 0870


Contact. 8.2 stuck Open
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 254/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0870

Check/Repair/replace contactor 8.2.


Check/Repair/replace wiring between Contactor and
TCU.

Fault gone?

No Yes

Check/Repair/replace CB 127.2/1.
Also Check wiring between CB 127.2/1 &
contactor 8.2 and between CB 127.2/1 & CB
218. If necessary replace wires.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/1,415/2 415/1,415/2
HF contactor 8.2 8.2

Condition:
- HF test is not active.
- HF contactor 8.2 is triggered.
- HF contactor 8.2 is opened.
- MR pressure is more than 8 bar.
- TC1 and TC2 is available.

Criteria:
- Triggering signal from TCU is given to HF contactor 8.2 but then also no feedback from contactor
received in TCU.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 255/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.131 CCU Fault Code 0871
Contact 8.2 stuck Closed
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0871

Check/Repair/replace contactor 8.2


Check/Repair/replace wiring between Contactor and
TCU.

Fault gone?

No Yes

Check/Repair/replace CB 127.2/1.
Also Check wiring between CB 127.2/1 &
contactor 8.2 and between CB 127.2/1 & CB
218. If necessary replace wires.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/1,415/2 415/1,415/2
HF contactor 8.2 8.2

Condition:
- HF test is active.
- Reset signal is given to 8.2 contactor.
- Either TC1 or TC2 is not available.

Criteria:
- Reset signal from TCU is given to contactor 8.2 but then also feedback from contactor 8.2 is
available in TCU DI.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 256/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.132 CCU Fault Code 0872
Harmonic filter: Contact 8.1 Stuck Opned
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 257/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0872

Check/Repair/replace contactor 8.1.


Check/Repair/replace wiring between Contactor and
TCU.

Fault gone?

No Yes

Check/Repair/replace CB 127.2/1.
Also Check wiring between CB 127.2/1 &
contactor 8.1 and between CB 127.2/1 & CB
218. If necessary replace wires.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/1,415/2 415/1,415/2
HF contactor 8.1 8.1

Condition:
- HF test is active.
- HF contactor 8.1 is triggered.
- HF contactor 8.41 is opened.
- VCB is closed.
- MR pressure is more than 8 bar.

Criteria:
- Triggering signal from TCU is given to HF contactor 8.1 but then also no feedback from contactor
received in TCU.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 258/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.133 CCU Fault Code 0873
Harmonic filter: Contact 8.1 stuck Closed
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 259/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0873

Check/Repair/replace contactor 8.1.


Check/Repair/replace wiring between Contactor and
TCU.

Fault gone?

No Yes

Check/Repair/replace CB 127.2/1.
Also Check wiring between CB 127.2/1 &
contactor 8.1 and between CB 127.2/1 & CB
218. If necessary replace wires.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/1,415/2 415/1,415/2
HF contactor 8.1 8.1

Condition:
- HF test is active.
- HF contactor 8.1 is not triggered..
- VCB is opened.
- Contactor 8.2 stuck closed.
- Contactor 8.41 is closed.

Criteria:
- HF inrush is high and VCB tripped.
- Reset signal from TCU is given to HF contactor 8.1 but then also feedback from contactor 8.1 is
available in TCU DI.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 260/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.134 CCU Fault Code 0874
Harmonic filter: Contact 8.41 Stuck Open
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 261/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0874

Check/Repair/replace contactor 8.41.


Check/Repair/replace wiring between Contactor and
TCU.

Fault gone?

No Yes

Check/Repair/replace CB 127.2/1.
Also Check wiring between CB 127.2/1 &
contactor 8.41 and between CB 127.2/1 &
CB 218. If necessary replace wires.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/1,415/2 415/1,415/2
HF contactor 8.41 8.41

Condition:
- HF test is active.
- HF contactor 8.41 is triggered.
- HF contactor 8.1 is opened.
- VCB is opened.

Criteria:
- Triggering signal from TCU is given to HF contactor 8.41 but then also no feedback from
contactor received in TCU.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 262/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.135 CCU Fault Code 0875
Harmonic filter: Contact 8.41 Stuck Closed
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0875

Check/Repair/replace contactor 8.41.


Check/Repair/replace wiring between Contactor and
TCU.

Fault gone?

No Yes

Check/Repair/replace CB 127.2/1.
Also Check wiring between CB 127.2/1 &
contactor 8.41 and between CB 127.2/1 &
CB 218. If necessary replace wires.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/1,415/2 415/1,415/2
HF contactor 8.41 8.41

Condition:
- HF test is active.
- HF contactor 8.1 is opened.
- VCB is closed.

Criteria:
- Reset signal from TCU is given to HF contactor 8.41 but then also feedback from contactor 8.41
is available in TCU DI.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 263/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 264/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.136 CCU Fault Code 0876
Harmonic filter: Inrush current to high, VCB off
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 265/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0876

Check wiring of for Short circuits. This includes the


following devices:
- Line current converter
- current sensor
- Main transformer
(see circ. Diagrams 01A,12B,12F)

Switch on MCB

Check wiring of following for Short circuits.


That includes:
- Traction converters
Problem solved? No
- Traction motors
- All auxiliary loads on the loco
Yes

Switch on MCB

Internal defect in
Harmonic filter. No Problem solved?

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/1,415/2 415/1,415/2
HF contactor 8.1 8.1

Condition:
- CCU is master.
- HF contactor 8.1 is triggered.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 266/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Criteria:
- AC harmonic current detected by TCU 1 or TCU 2 is greater than 600A.

Reaction:
- Fault code triggered
- VCB tripped.

Related messages:
-

3.2.137 CCU Fault Code 0877


Harmonic filter: Over current detected, VCB off
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 267/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0877

Check for the following reasons:


1. Disturbance in measurement of HF
current. Check the HF current sensor 8.5/
1,8.5/2.
2. Fault in converter.
3. Short circuit in transformer winding.
4. Check machine room for oil flash/smoke/
abnormal.
5. Check Harmonic filter for internal fault.
If anything is not ok then shut the Loco.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/1,415/2 415/1,415/2
HF contactor 8.1 8.1

Condition:
- CCU is master.
- HF contactor 8.1 is triggered.

Criteria:
- AC harmonic current detected by TCU 1 or TCU 2 is greater than 400A.

Reaction:
- Fault code triggered
- VCB tripped.

Related messages:
-
3.2.138 CCU Fault Code 0878
Harmonic filter: Harmonic filter test failed
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 268/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 878

Switch off/on CB 218


&
CB 127.2/1.

Check/repair wiring of 8.1_1B to 20(XK42A) TCU1 &


20(XK57A) TCU2, 8.2_1B to 21(XK42A) TCU1 &
Message gone? No 21(XK57A) TCU2, 8.41_1B to 22(XK42A) TCU1 &
22(XK57A) TCU2.
and 8.1_1A, 8.2_1A, 8.41_1A to 127.2/1

Yes Problem solved?

No

Check/repair/replace the contactor


8.1, 8.2,8.41
Yes

Yes Problem solved?

No

Contact Siemens
maintenance personnel.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/1,415/2 415/1,415/2
HF contactor 8.1,8.2,8.41 8.1,8.2,8.41

Condition:
- CCU is master.

Criteria:
- One of the contactors 8.41, 8.1, 8.2 failed to open withing time period 300ms to 2000ms after
receiving reset command.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 269/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Reaction:
- Fault code triggered

Related messages:
-

3.2.139 CCU Fault Code 0910


Battery charger: Fault detected
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 270/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0910

Check, if the battery charger has an issue in real, or if the I/O signal
does have a fault.

The fault must be within the I/O signal.


Check/repair wiring From 411.RA/11 to E117_10
Is battery charger ok? Yes
and E127_10.
If necessary replace module.

No

The battery charger must have an internal


fault.
Check battery charger according to
customer documentation.
Replace battery charger if necessary.

Yes Problem found and solved?

No

Check Wiring between AUX


and CCU

If necessary replace module


by a trouble-free spare part

End

Components concerned:
Component Device name CCU1 Device name CCU2
AUX 426/1, 426/2, 426/3 426/1, 426/2, 426/3

Condition:
- AUX 1 & AUX 2 is ok and running.
- K03 switch is on.

Criteria:
- Battery charger of 6k is not ok as there is no feedback signal received on digital input E117_10 &
E127_10 for minimum 20sec.
- In 9k battery charger diagnostic status is not available in CCU from AUX3.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 271/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Reaction:
- Fault code triggered

3.2.140 CCU Fault Code 0931


CDS: Speed invalid
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 272/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0931

It is nearly implausible, that all of these eight speed sensors does have a fault at the same time.
The issue must be a general fault.

Is the
fault permanent Yes
active?

No

There must be a general fault with the MVB


Check CCU and TCU diagnostic storage, if any other reason can be
communication on the loco or with the loaded software
found.
versions.
For example repeated communication faults to MVB participants,
Check loaded software versions.
especially TCUs.
Check general operation of the loco.
This communication fault will lead to further other issues with the
Check diagnostic storage of TCUs and CCU, to find the
locomotive. Follow the instructions of the communication fault codes.
root cause.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/1,415/2 415/1,415/2
Speed sensor 93.2/1,93.2/2,93.2/3,93.2/4,93.2/5, 93.2/1,93.2/2,93.2/3,93.2/4,93.2/5,
93.2/6 93.2/6

Condition:
-

Criteria:
- Speed sensor system is completely failed. All speed sensors failed.
- Actual speed by TM is beyond tolerance limit.

Reaction:
- Fault code triggered

Related messages:

3.2.141 CCU Fault Code 0933


CDS: Calculated wheel diamter out of range
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 273/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0933

Check if
reference wheel diameter is No
set correctly in CCU.

Adjust wheel diameter of the reference axle with SIBAS-Monitor.

Yes

Perform automatic recalibration on track.

Recalibration was successful? No

Check TCU and CCU diagnostic storage for other diagnostic


codes. Maybe there is a general fault with the speed sensors.

Yes

End

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
-

Criteria:
- One of the wheel diameter calculated is out of range. Or failure in calculation of wheel diameter.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 274/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.142 CCU Fault Code 0934
CDS: Milage invalid
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 275/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 0934

Ensure that both TCUs are available. Reset Master CCU so


that former Slave CCU becomes to Master CCU. Wait 30s.

Fault gone? Yes

No

Reset Master CCU so that primarily Master CCU becomes


Master again. Wait 30s.

Fault still gone? Yes

No

Reset TCU1. Wait 30s.

Fault gone? Yes

No

Reset TCU2. Wait 30s.

Fault gone? Yes

No

Reentry mileage in CCU-Master.


Restart complete locomotive.

Fault gone? Yes

No

Check battery in the control units of CCU and TCU and replace them if necessary.

End

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
- No new value entered by user.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 276/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Criteria:
- The actual mileage is synchronised between the Master CCU, the Slave CCU an both TCUs.
The Master CCU supvervises, if all values does have the same mileage value.
If a deviation of more than 1 mile is detected, this error code is entried.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 277/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.143 CCU Fault Code 0936
CDS: Reference axle diameter out of range
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0936

Has the Input wheel diameter of the


software been Yes reference axle with SIBAS-Monitor.
reloaded? .

No

CCU-Master and CCU-Slave should be switched on. No communication fault


between this two devices should be active.
Reentry the diagnostic code in CCU-Master.

Fault gone? Yes

No

The displays and the CCUs should be switched on. No communication fault
between these devices should be active.
Reentry the diagnostic code in the display.

Fault gone? Yes

No

Reload CCU Software in both CCUs.


Reentry reference wheel diameter after software reload (Menu see above)

Fault gone? Yes

No

Check battery in the control units of CCU

Fault gone? Yes

No

Replace CCU CPU module of the CCU with the failure.

End

Components concerned:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 278/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Component Device name CCU1 Device name CCU2

Condition:
-

Criteria:
- The reference wheel diameter is out of the limits (minimum value 1015.8mm and maximum value
1092..2 mm)

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 279/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.144 CCU Fault Code 0947
CDS: Stored value for reference axle diameter out of range
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 0947

The value for wheel diameter of the reference axle is stored in two memory locations inside the CCU.
In general a deviation could indicate a creeping loss of memory.

Input wheel diameter of the reference axle with SIBAS-Monitor.

Does the
fault occur Yes
again?
Reload actual CCU software in the CCU with SIBAS
Monitor.

Does the
fault occur Yes
again?

No

No Replace CCU CPU module of the CCU with the failure.

After replacement:
- load CCU software again
- adjust wheel diameter again

End

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
- System runs ok.

Criteria:
- There is a difference for the two memory locations for the diameter of the reference axle inside
the CCU control.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 280/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Reaction:
- Fault code triggered

Related messages:
-

3.2.145 CCU Fault Code 0951


CDS: Speed sensor axel 1 failure
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 281/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 951

Check / repair speed sensor 93.2/


1.

Check /repair wiring between


Problem solved? No
sensor and TCU1

Yes
No

Yes Problem solved?

No

Contact Siemens
maintenance personnel.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/1 415/1
Speed sensor 93.2/1 93.2/1

Condition:

Criteria:
- Actual speed of TM1 in Kmph is valid but raw speed value given by speed sensor 93.2/1 of TM1
is not valid.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 282/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.146 CCU Fault Code 0952
CDS: Speed sendor axel 2 failure
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 952

Check / repair speed sensor 93.2/


2.

Check /repair wiring between


Problem solved? No
sensor and TCU1

Yes
No

Yes Problem solved?

No

Contact Siemens
maintenance personnel.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/1 415/1
Speed sensor 93.2/2 93.2/2

Condition:

Criteria:
- Actual speed of TM2 in Kmph is valid but raw speed value given by speed sensor 93.2/2 of TM2
is not valid.

Reaction:
- Fault code triggered
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 283/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 284/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.147 CCU Fault Code 0953
CDS: Speed sensor axel 3 failure
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 953

Check / repair speed sensor 93.2/


3.

Check /repair wiring between


Problem solved? No
sensor and TCU1

Yes
No

Yes Problem solved?

No

Contact Siemens
maintenance personnel.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/1 415/1
Speed sensor 93.2/3 93.2/3

Condition:

Criteria:
- Actual speed of TM3 in Kmph is valid but raw speed value given by speed sensor 93.2/3 of TM3
is not valid.

Reaction:
- Fault code triggered
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 285/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 286/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.148 CCU Fault Code 0954
CDS: Speed sensor axel 4 failure
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 954

Check / repair speed sensor 93.2/


4.

Check /repair wiring between


Problem solved? No
sensor and TCU2

Yes
No

Yes Problem solved?

No

Contact Siemens
maintenance personnel.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/2 415/2
Speed sensor 93.2/4 93.2/4

Condition:

Criteria:
- Actual speed of TM4 in Kmph is valid but raw speed value given by speed sensor 93.2/4 of TM4
is not valid.

Reaction:
- Fault code triggered
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 287/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 288/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.149 CCU Fault Code 0955
CDS: Speed sensor axel 5 failure
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 955

Check / repair speed sensor 93.2/


5.

Check /repair wiring between


Problem solved? No
sensor and TCU2

Yes
No

Yes Problem solved?

No

Contact Siemens
maintenance personnel.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/2 415/2
Speed sensor 93.2/5 93.2/5

Condition:

Criteria:
- Actual speed of TM5 in Kmph is valid but raw speed value given by speed sensor 93.2/5 of TM5
is not valid.

Reaction:
- Fault code triggered
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 289/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 290/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.150 CCU Fault Code 0956
CDS: Speed sensor axel 6 failure
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 956

Check / repair speed sensor 93.2/


6.

Check /repair wiring between


Problem solved? No
sensor and TCU2

Yes
No

Yes Problem solved?

No

Contact Siemens
maintenance personnel.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU 415/2 415/2
Speed sensor 93.2/6 93.2/6

Condition:

Criteria:
- Actual speed of TM6 in Kmph is valid but raw speed value given by speed sensor 93.2/6 of TM6
is not valid.

Reaction:
- Fault code triggered
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 291/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 292/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.151 CCU Fault Code 1002
Brake Pipe Pressure Switch Signal is not plausible.
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1002

Switch off/on CB
control circuit 126 &
Pneumatic panel CB
127.7.

Check/repair wiring of EA213_01 to


autobrake pressure transducer 269. If
Message gone? No
necessary replace pressure transducer or
wiring.

Yes Problem solved?

No

Check repair wiring of E212_10 and


E222_07 to emergency brake pressure
Yes switch. If necessary replace wiring or
pressure switch.

Yes Problem solved?

No

Contact Siemens
maintenance personnel.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E212 E212
IO station 22 E222 E222
Pressure transducer auto
brake pipe
Emergency brake pressure 269 269
switch
269.1 269.1

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 293/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- Brake pipe pressure is less than 2.5 bar and Pressure switch emergency brake not active.
- OR Brake pipe pressure is greater than 4.7 bar and pressure switch emergency brake is active.

Criteria:
- Analog brake pipe pressure value doesn’t fit to the BP pressure switch.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 294/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.152 CCU Fault Code 1003
MR-Pressure Switch Signals are not plausible.
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1003

Switch off/on CB
control circuit 126 &
Pneumatic panel CB
127.7.

Check/repair wiring of 172.2,172.3 and


Message gone? No
269.4 to CB 127.7 .

Yes Problem solved?

No

Check repair wiring E222_11 to MR PS1 172.2 _Q2,


E222_09, E212_02 to MR PS2 172.3_Q2,
E212_03,E222_14 to MR PS3 269.4_Q2. If necessary replace
Yes wiring or pressure switch.

Yes Problem solved?

No

Contact Siemens
maintenance personnel.

End

Components concerned:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 295/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Component Device name CCU1 Device name CCU2
IO station 22 E222 E222
IO station 21 E212 E212
Pressure switch main
compressor 1 172.2
Pressure switch main 172.2
compressor 2 172.3
Pressure switch low main 172.3
compressor 3 269.4
269.4

Condition:

Criteria:
- One of MR pressure switch 1 and MR pressure switch 2 more than 8 bar and MR pressure switch
3 shows less than 5.6 bar. Thus, MR pressure switch signals are not plausible.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 296/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.153 CCU Fault Code 1158
Parking Brake Releasing failed.
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1158

Check / repair parking brake


release EP valve (270.4_06B01).

Check Wiring between EP valve 270.4


Problem solved? No and DO (A215_06,A226_04) module and
repair it.

Yes
Yes Problem solved?

No

Check pressure feedback from pressure


switch P3.5 (269.3_06B11). Check pressure
switch is ok or not and repair it

Yes Problem solved?

No

Check/repair wiring from pressure switch


to DI (E212_14, E222_01) module

Yes Problem solved?

No

Contact Siemens
maintenance personnel.

End

Components concerned:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 297/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Component Device name CCU1 Device name CCU2
EP valve 270.4 270.4
IO station 21 A215 A21
IO station 22 E222 E222
Pressure switch P3.5(269.3) P3.5(269.3)

Condition:
- Parking brake release button was pressed and loco is switched on.
- Park brake pressure is greater than 3.5 bar.

Criteria:
- Park brake release command is given, and park brake release magnet valve is closed for more
than 30 seconds.
- Park brake is not released in own loco.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 298/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.154 CCU Fault Code 1159
Parking Brake Application failed.
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1159

Check / repair parking brake


release EP valve (270.3_06B02).

Check Wiring between EP valve 270.4


Problem solved? No and DO (A215_07,A226_05) module and
repair it.

Yes
Yes Problem solved?

No

Check pressure feedback from pressure


switch P3.5 (269.3_06B11). Check pressure
switch is ok or not and repair it

Yes Problem solved?

No

Check/repair wiring from pressure switch


to DI (E212_14, E222_01) module

Yes Problem solved?

No

Contact Siemens
maintenance personnel.

End

Components concerned:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 299/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Component Device name CCU1 Device name CCU2
EP valve 270.3 270.3
IO station 21 A215 A215
IO station 22 E222 E222
Pressure switch P3.5(269.3) P3.5(269.3)

Condition:
- Parking brake apply button was pressed and loco is switched on.
- Park brake pressure is less than 3.5 bar.

Criteria:
- Park brake apply command is given, and park brake apply magnet valve is opened for more than
30 seconds.
- Park brake is not applied in own loco.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 300/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.155 CCU Fault Code 1162
Fault in Brake Electronics.
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1162

Check / repair IO module


E123_01/E222_05.

Problem solved?

No

Check Wiring between DI E123_01 /


Yes
E222_05 and BCU 260.

Problem solved? Yes

No

Check/Repair/Replace BCU 260.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station12 E123 E123
IO station 22 E222 E222
Pressure switch P3.5(269.3) P3.5(269.3)

Condition:

Criteria:
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 301/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- No feedback available from brake electronics to digital input E123_01/E222_05.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 302/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.156 CCU Fault Code 1300
Ext IO 11: AS Module defective
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1300

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of L-Bus connector
and front connectors
and switch I/O station 11 on again.

Code
still triggered in Yes
CCU?

Read out CCU diagnostic memory. Analyze diagnostic environment of


the diagnostic entry.The error word shows, which issues have led to
the diagnostic entry.

Check always hardware of the I/O module:


- Are all L_Bus cables plugged correctly? Repress the plugs of the
L_Bus cables accurately. The plugs do lock in place late.
- Is there a damage on the L_Bus cable? The shielding should not be
damaged in any way.
No
- Is the wiring of the I/O modules correct (inputs, outputs, power
supply)?
- Are all plugs of the I/O module fitted correctly?
- Is the shielding of the MVB-cable, shielding of other cables and the
grounding carried out correctly?

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station E122 E122
PS module PS11 PS11
CB 127.9/1 127.9/1

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 303/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- MVB communication between CCU master and IO sation 11 and 12 is ok.
- CB 127.9/1 is ok.
- Wiring between IO module pin E122_15 and CB 127.9/1 is ok.

Criteria
Issues can be:
- General status faulty
- Error on L_Bus
- NSDB Error
- Component Error
- Sink Port Error
- Watchdog Error

Reaction:
- Fault code triggered

Related messages:
3.2.157 CCU Fault Code 1301
Ext.IO 11: Module 1 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 304/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 1301

Switch I/O station 11


(use CB I/O station 11, -127.9/1),
check correctness of serial Bus
connector
and front connectors
on module 1
and switch I/O station 11 (-127.9/1) on
again .

Code
still triggered in Yes
CCU?

Exchange module 1 (E111)


on I/O station 11
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E111 E111

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- slot status error for module 1 in IO station 11 is set

Reaction:
- Fault code triggered
- Module 1 on I/O station 11 is inoperative. The critical signals available at module 1 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

3.2.158 CCU Fault Code 1302


Ext.IO 11: Module 2 defective
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 305/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1302

Switch I/O station 11


(use CB I/O station 11, -127.9/1),
check correctness of serial Bus
connector
and front connectors
on module 2
and switch I/O station 11 (-127.9/1) on
again .

Code
still triggered in Yes
CCU?

Exchange module 2 (E112)


on I/O station 11.
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E112 E112

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- slot status error for module 2 in IO station 11 is set

Reaction:
- Fault code triggered
- Module 2 on I/O station 11 is inoperative. The critical signals available at module 2 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 306/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 307/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.159 CCU Fault Code 1303
Ext.IO 11: Module 3 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1303

Switch I/O station 11


(use CB I/O station 11, -127.9/1),
check correctness of serial Bus
connector
and front connectors
on module 3
and switch I/O station 11 (-127.9/1) on
again .

Code
still triggered in Yes
CCU?

Exchange module 3 (E113)


on I/O station 11
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E113 E113

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- slot status error for module 3 in IO station 11 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 308/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 3 on I/O station 11 is inoperative. The critical signals available at module 3 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 309/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.160 CCU Fault Code 1304
Ext.IO 11: Module 4 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1304

Switch I/O station 11


(use CB I/O station 11, -127.9/1),
check correctness of serial Bus
connector
and front connectors
on module 4
and switch I/O station 11 (-127.9/1) on
again .

Code
still triggered in Yes
CCU?

Exchange module 4 (E114)


on I/O station 11
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E114 E114

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- slot status error for module 4 in IO station 11 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 310/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 4 on I/O station 11 is inoperative. The critical signals available at module 4 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 311/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.161 CCU Fault Code 1305
Ext.IO 11: Module 5 defective

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1305

Switch I/O station 11


(use CB I/O station 11, -127.9/1),
check correctness of serial Bus
connector
and front connectors
on module 5
and switch I/O station 11 (-127.9/1) on
again .

Code
still triggered in Yes
CCU?

Exchange module 5 (E115)


on I/O station 11
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E115 E115

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- slot status error for module 5 in IO station 11 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 312/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 5 on I/O station 11 is inoperative. The critical signals available at module 5 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 313/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.162 CCU Fault Code 1306
Ext.IO 11: Module 6 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1306

Switch I/O station 11


(use CB I/O station 11, -127.9/1),
check correctness of serial Bus
connector
and front connectors
on module 6
and switch I/O station 11 (-127.9/1) on
again .

Code
still triggered in Yes
CCU?

Exchange module 6 (E116)


on I/O station 11
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E116 E116

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- slot status error for module 6 in IO station 11 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 314/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 6 on I/O station 11 is inoperative. The critical signals available at module 6 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 315/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.163 CCU Fault Code 1307
Ext.IO 11: Module 7 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1307

Switch I/O station 11


(use CB I/O station 11, -127.9/1),
check correctness of serial Bus
connector
and front connectors
on module 7
and switch I/O station 11 (-127.9/1) on
again .

Code
still triggered in Yes
CCU?

Exchange module 7 (E117)


on I/O station 11
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E117 E117

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- slot status error for module 7 in IO station 11 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 316/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 7 on I/O station 11 is inoperative. The critical signals available at module 7 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 317/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.164 CCU Fault Code 1308
Ext.IO 12: AS Module defective
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1308

Switch I/O station 12


(use CB I/O station 12, 127.9/2),
check correctness of L-Bus connector
and front connectors
and switch I/O station 12 on again.

Code
still triggered in Yes
CCU?

Read out CCU diagnostic memory. Analyze diagnostic environment of


the diagnostic entry.The error word shows, which issues have led to
the diagnostic entry.

Check always hardware of the I/O module:


- Are all L_Bus cables plugged correctly? Repress the plugs of the
L_Bus cables accurately. The plugs do lock in place late.
- Is there a damage on the L_Bus cable? The shielding should not be
damaged in any way.
No
- Is the wiring of the I/O modules correct (inputs, outputs, power
supply)?
- Are all plugs of the I/O module fitted correctly?
- Is the shielding of the MVB-cable, shielding of other cables and the
grounding carried out correctly?

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E111 E111
PS module PS12 PS12
CB 127.9/2 127.9/2

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 318/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- MVB communication between CCU master and IO sation 11 and 12 is ok.
- CB 127.9/2 is ok.
- Wiring between IO module pin E111_08 and CB 127.9/2 is ok.

Criteria
Issues can be:
- General status faulty
- Error on L_Bus
- NSDB Error
- Component Error
- Sink Port Error
- Watchdog Error

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 319/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.165 CCU Fault Code 1310
Ext.IO 12: Module 2 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1310

Switch I/O station 12


(use CB I/O station 12, -127.9/2),
check correctness of serial Bus
connector
and front connectors
on module 2
and switch I/O station 12 (-127.9/2) on
again .

Code
still triggered in Yes
CCU?

Exchange module 2 (E122)


on I/O station 12
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E122 E122

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- slot status error for module 2 in IO station 12 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 320/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 2 on I/O station 12 is inoperative. The critical signals available at module 2 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 321/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.166 CCU Fault Code 1311
Ext.IO 12: Module 3 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1311

Switch I/O station 12


(use CB I/O station 12, -127.9/2),
check correctness of serial Bus
connector
and front connectors
on module 1
and switch I/O station 12 (-127.9/2) on
again .

Code
still triggered in Yes
CCU?

Exchange module 3 (E123)


on I/O station 12
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E123 E123

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- slot status error for module 3 in IO station 12 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 322/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 3 on I/O station 12 is inoperative. The critical signals available at module 3 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 323/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.167 CCU Fault Code 1312
Ext.IO 12: Module 4 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1312

Switch I/O station 12


(use CB I/O station 12, -127.9/2),
check correctness of serial Bus
connector
and front connectors
on module 4
and switch I/O station 12 (-127.9/2) on
again .

Code
still triggered in Yes
CCU?

Exchange module 4 (E124)


on I/O station 12
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E124 E124

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- slot status error for module 4 in IO station 12 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 324/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 4 on I/O station 12 is inoperative. The critical signals available at module 4 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 325/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.168 CCU Fault Code 1313
Ext.IO 12: Module 5 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1313

Switch I/O station 12


(use CB I/O station 12, -127.9/2),
check correctness of serial Bus
connector
and front connectors
on module 5
and switch I/O station 12 (-127.9/2) on
again .

Code
still triggered in Yes
CCU?

Exchange module 5 (E125)


on I/O station 12
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E125 E125

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- slot status error for module 5 in IO station 12 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 326/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 5 on I/O station 12 is inoperative. The critical signals available at module 5 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 327/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.169 CCU Fault Code 1314
Ext.IO 12: Module 6 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1314

Switch I/O station 12


(use CB I/O station 12, -127.9/2),
check correctness of serial Bus
connector
and front connectors
on module 6
and switch I/O station 12 (-127.9/2) on
again .

Code
still triggered in Yes
CCU?

Exchange module 6 (E126)


on I/O station 12
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E126 E126

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- slot status error for module 6 in IO station 12 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 328/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 6 on I/O station 12 is inoperative. The critical signals available at module 6 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 329/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.170 CCU Fault Code 1315
Ext.IO 12: Module 7 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1315

Switch I/O station 12


(use CB I/O station 12, -127.9/2),
check correctness of serial Bus
connector
and front connectors
on module 7
and switch I/O station 12 (-127.9/2) on
again .

Code
still triggered in Yes
CCU?

Exchange module 7 (E127)


on I/O station 12
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E127 E127

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- slot status error for module 7 in IO station 12 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 330/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 7 on I/O station 12 is inoperative. The critical signals available at module 7 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 331/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.171 CCU Fault Code 1316
Ext.IO 21: AS Module defective
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1316

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of L-Bus connector
and front connectors
and switch I/O station 21 on again.

Code
still triggered in Yes
CCU?

Read out CCU diagnostic memory. Analyze diagnostic environment of


the diagnostic entry.The error word shows, which issues have led to
the diagnostic entry.

Check always hardware of the I/O module:


- Are all L_Bus cables plugged correctly? Repress the plugs of the
L_Bus cables accurately. The plugs do lock in place late.
- Is there a damage on the L_Bus cable? The shielding should not be
damaged in any way.
No
- Is the wiring of the I/O modules correct (inputs, outputs, power
supply)?
- Are all plugs of the I/O module fitted correctly?
- Is the shielding of the MVB-cable, shielding of other cables and the
grounding carried out correctly?

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 22 E223 E223
PS module PS21 PS21
CB 127.9/3 127.9/3

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 332/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- MVB communication between CCU master and IO sation 21 and 22 is ok.
- CB 127.9/3 is ok.
- Wiring between IO module pin E223_12 and CB 127.9/3 is ok.

Criteria
Issues can be:
- General status faulty
- Error on L_Bus
- NSDB Error
- Component Error
- Sink Port Error
- Watchdog Error

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 333/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.172 CCU Fault Code 1317
Ext.IO 21: Module 1 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1317

Switch I/O station 21


(use CB I/O station 21, -127.9/3),
check correctness of serial Bus
connector
and front connectors
on module 1
and switch I/O station 21 (-127.9/3) on
again .

Code
still triggered in Yes
CCU?

Exchange module 1 (E211)


on I/O station 21
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E211 E211

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- slot status error for module 1 in IO station 21 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 334/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 1 on I/O station 21 is inoperative. The critical signals available at module 1 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 335/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.173 CCU Fault Code 1318
Ext.IO 21: Module 2 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1318

Switch I/O station 21


(use CB I/O station 21, -127.9/3),
check correctness of serial Bus
connector
and front connectors
on module 2
and switch I/O station 21 (-127.9/3) on
again .

Code
still triggered in Yes
CCU?

Exchange module 2 (E212)


on I/O station 21
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E212 E212

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- slot status error for module 2 in IO station 21 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 336/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 2 on I/O station 21 is inoperative. The critical signals available at module 2 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 337/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.174 CCU Fault Code 1319
Ext.IO 21: Module 3 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1319

Switch I/O station 21


(use CB I/O station 21, -127.9/3),
check correctness of serial Bus
connector
and front connectors
on module 3
and switch I/O station 21 (-127.9/3) on
again .

Code
still triggered in Yes
CCU?

Exchange module 3 (E213)


on I/O station 21
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 module 3 E213 E213

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- slot status error for module 3 in IO station 21 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 338/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 3 on I/O station 21 is inoperative. The critical signals available at module 3 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 339/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.175 CCU Fault Code 1320
Ext.IO 21: Module 4 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1320

Switch I/O station 21


(use CB I/O station 21, -127.9/3),
check correctness of serial Bus
connector
and front connectors
on module 4
and switch I/O station 21 (-127.9/3) on
again .

Code
still triggered in Yes
CCU?

Exchange module 4 (E214)


on I/O station 21
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E214 E214

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- slot status error for module 4 in IO station 21 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 340/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 4 on I/O station 21 is inoperative. The critical signals available at module 4 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 341/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.176 CCU Fault Code 1321
Ext.IO 21: Module 5 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1321

Switch I/O station 21


(use CB I/O station 21, -127.9/3),
check correctness of serial Bus
connector
and front connectors
on module 5
and switch I/O station 21 (-127.9/3) on
again .

Code
still triggered in Yes
CCU?

Exchange module 5 (E215)


on I/O station 21
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E215 E215

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- slot status error for module 5 in IO station 21 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 342/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 5 on I/O station 21 is inoperative. The critical signals available at module 5 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 343/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.177 CCU Fault Code 1322
Ext.IO 21: Module 6 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1322

Switch I/O station 21


(use CB I/O station 21, -127.9/3),
check correctness of serial Bus
connector
and front connectors
on module 6
and switch I/O station 21 (-127.9/3) on
again .

Code
still triggered in Yes
CCU?

Exchange module 6 (E216)


on I/O station 21
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E216 E216

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- slot status error for module 6 in IO station 21 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 344/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 6 on I/O station 21 is inoperative. The critical signals available at module 6 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 345/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.178 CCU Fault Code 1323
Ext.IO 21: Module 7 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1323

Switch I/O station 21


(use CB I/O station 21, -127.9/3),
check correctness of serial Bus
connector
and front connectors
on module 7
and switch I/O station 21 (-127.9/3) on
again .

Code
still triggered in Yes
CCU?

Exchange module 7 (E217)


on I/O station 21
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E217 E217

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- slot status error for module 7 in IO station 21 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 346/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 7 on I/O station 21 is inoperative. The critical signals available at module 7 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 347/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.179 CCU Fault Code 1324
Ext.IO 22: AS Module defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1324

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of L-Bus connector
and front connectors
and switch I/O station 22 on again.

Code
still triggered in Yes
CCU?

Read out CCU diagnostic memory. Analyze diagnostic environment of


the diagnostic entry.The error word shows, which issues have led to
the diagnostic entry.

Check always hardware of the I/O module:


- Are all L_Bus cables plugged correctly? Repress the plugs of the
L_Bus cables accurately. The plugs do lock in place late.
- Is there a damage on the L_Bus cable? The shielding should not be
damaged in any way.
No
- Is the wiring of the I/O modules correct (inputs, outputs, power
supply)?
- Are all plugs of the I/O module fitted correctly?
- Is the shielding of the MVB-cable, shielding of other cables and the
grounding carried out correctly?

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E211 E211
PS module PS22 PS22
CB 127.9/4 127.9/4

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 348/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- MVB communication between CCU master and IO sation 21 and 22 is ok.
- CB 127.9/4 is ok.
- Wiring between IO module pin E211_03 and CB 127.9/4 is ok.

Criteria
Issues can be:
- General status faulty
- Error on L_Bus
- NSDB Error
- Component Error
- Sink Port Error
- Watchdog Error

Reaction:
- Fault code triggered

Related messages:
3.2.180 CCU Fault Code 1325
Ext.IO 22: Module 1 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 349/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 1325

Switch I/O station 22


(use CB I/O station 22, -127.9/4),
check correctness of serial Bus
connector
and front connectors
on module 1
and switch I/O station 22 (-127.9/4) on
again .

Code
still triggered in Yes
CCU?

Exchange module 1 (E221)


on I/O station 22
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E221 E221

Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- slot status error for module 1 in IO station 22 is set

Reaction:
- Fault code triggered
- Module 1 on I/O station 22 is inoperative. The critical signals available at module 1 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 350/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.181 CCU Fault Code 1326
Ext.IO 22: Module 2 defective
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1326

Switch I/O station 22


(use CB I/O station 22, -127.9/4),
check correctness of serial Bus
connector
and front connectors
on module 2
and switch I/O station 22 (-127.9/4) on
again .

Code
still triggered in Yes
CCU?

Exchange module 2 (E222)


on I/O station 22
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E222 E222

Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- slot status error for module 2 in IO station 22 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 351/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 2 on I/O station 22 is inoperative. The critical signals available at module 2 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 352/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.182 CCU Fault Code 1327
Ext.IO 22: Module 3 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1327

Switch I/O station 22


(use CB I/O station 22, -127.9/4),
check correctness of serial Bus
connector
and front connectors
on module 3
and switch I/O station 22 (-127.9/4) on
again .

Code
still triggered in Yes
CCU?

Exchange module 3 (E223)


on I/O station 22
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E223 E223

Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- slot status error for module 3 in IO station 22 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 353/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 3 on I/O station 22 is inoperative. The critical signals available at module 3 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 354/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.183 CCU Fault Code 1328
Ext.IO 22: Module 4 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1328

Switch I/O station 22


(use CB I/O station 22, -127.9/4),
check correctness of serial Bus
connector
and front connectors
on module 4
and switch I/O station 22 (-127.9/4) on
again .

Code
still triggered in Yes
CCU?

Exchange module 4 (E224)


on I/O station 22
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E224 E224

Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- slot status error for module 4 in IO station 22 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 355/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 4 on I/O station 22 is inoperative. The critical signals available at module 1 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 356/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.184 CCU Fault Code 1329
Ext.IO 22: Module 5 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1329

Switch I/O station 22


(use CB I/O station 22, -127.9/4),
check correctness of serial Bus
connector
and front connectors
on module 5
and switch I/O station 22 (-127.9/4) on
again .

Code
still triggered in Yes
CCU?

Exchange module 5 (E225)


on I/O station 22
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E225 E225

Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- slot status error for module 5 in IO station 22 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 357/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 5 on I/O station 22 is inoperative. The critical signals available at module 5 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 358/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.185 CCU Fault Code 1330
Ext.IO 22: Module 6 defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1330

Switch I/O station 22


(use CB I/O station 22, -127.9/4),
check correctness of serial Bus
connector
and front connectors
on module 6
and switch I/O station 22 (-127.9/4) on
again .

Code
still triggered in Yes
CCU?

Exchange module 6 (E226)


on I/O station 22
No

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E226 E226

Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- slot status error for module 6 in IO station 22 is set

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 359/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- Module 6 on I/O station 22 is inoperative. The critical signals available at module 6 are redundant
and hence they are automatically taken over by the CCU software. Therefore, creating no
reduction in loco functionality.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 360/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.186 CCU Fault Code 1335
Ext.IO 11: E112_00 Hardware error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1335

General information:
I/O Module: EA112 (EA112_00)
Circuit diagram power supply: PS11

Read out CCU diagnostic memory.


Analyze diagnostic environment of the diagnostic entry.
The error word shows, which issues have led to the diagnostic entry.

Check always hardware of the I/O module:


- Are all L_Bus cables plugged correctly? Repress the plugs of the L_Bus cables accurately.
The plugs do lock in place late.
- Is there a damage on the L_Bus cable? The shielding should not be damaged in any way.
- Is the wiring of the I/O modules correct (inputs, outputs, power supply)?
- Are all plugs of the I/O module fitted correctly?
- Is the shielding of the MVB-cable, shielding of other cables and the grounding carried out
correctly?

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E112 E112

Condition:

Criteria
- IO module E112_00 reports a hardware error.
Issues can be:
- General status faulty
- Error on L_Bus
- NSDB Error
- Component Error
- Sink Port Error
- Watchdog Error

Reaction:
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 361/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.187 CCU Fault Code 1331
Ext.IO 11: E112_00 Input voltage below or above limit values
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1331

Check the connector 411.EA/5 and


411.EA/9.
If not connected connect it. If it is
connected already then check whether
its connected properly or not and also
check whether it is connected to correct
pin in AI module EA112_00

Code
still triggered in Yes
CCU?

Check and replace wiring

No

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E112 E112

Condition:

Criteria
- The message is triggered every 2s if no lines are connected to the lutze inputs. E.g.
corresponding plug outside the VCU box not plugged in.

Reaction:
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 362/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.188 CCU Fault Code 1332
Ext.IO 11: E112_01 Input voltage below or above limit values
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1332

Check the connector 411.EC/1 and


411.EC/6.
If not connected connect it. If it is
connected already then check whether
its connected properly or not and also
check whether it is connected to correct
pin in AI module EA112_01

Code
still triggered in Yes
CCU?

Check and replace wiring

No

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E112 E112

Condition:

Criteria
- The message is triggered every 2s if no lines are connected to the lutze inputs. E.g.
corresponding plug outside the VCU box not plugged in.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 363/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.189 CCU Fault Code 1333
Ext.IO 11: E112_02 Input voltage below or above limit values
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1333

Check the connector 411.EC/3 and


411.EC/8.
If not connected connect it. If it is
connected already then check whether
its connected properly or not and also
check whether it is connected to correct
pin in AI module EA112_02

Code
still triggered in Yes
CCU?

Check and replace wiring

No

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E112 E112

Condition:

Criteria
- The message is triggered every 2s if no lines are connected to the lutze inputs. E.g.
corresponding plug outside the VCU box not plugged in.

Reaction:
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 364/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.190 CCU Fault Code 1334
Ext.IO 11: E112_03 Input voltage below or above limit values
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1334

Check corresponding connector and


input connections.
If plug not connected connect it. If it is
connected already then check whether
its connected properly or not and also
check whether it is connected to correct
pin in AI module EA112_03

Code
still triggered in Yes
CCU?

Check and replace wiring

No

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E112 E112

Condition:

Criteria
- The message is triggered every 2s if no lines are connected to the lutze inputs. E.g.
corresponding plug outside the VCU box not plugged in.

Reaction:
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 365/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.191 CCU Fault Code 1336
Ext.IO 11: E112_01 Hardware error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1336

General information:
I/O Module: EA112 (EA112_01)
Circuit diagram power supply: PS11

Read out CCU diagnostic memory.


Analyze diagnostic environment of the diagnostic entry.
The error word shows, which issues have led to the diagnostic entry.

Check always hardware of the I/O module:


- Are all L_Bus cables plugged correctly? Repress the plugs of the L_Bus cables accurately.
The plugs do lock in place late.
- Is there a damage on the L_Bus cable? The shielding should not be damaged in any way.
- Is the wiring of the I/O modules correct (inputs, outputs, power supply)?
- Are all plugs of the I/O module fitted correctly?
- Is the shielding of the MVB-cable, shielding of other cables and the grounding carried out
correctly?

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E112 E112

Condition:

Criteria
- IO module E112_01 reports a hardware error.
Issues can be:
- General status faulty
- Error on L_Bus
- NSDB Error
- Component Error
- Sink Port Error
- Watchdog Error

Reaction:
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 366/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.192 CCU Fault Code 1337
Ext.IO 11: E112_02 Hardware error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1337

General information:
I/O Module: EA112 (EA112_02)
Circuit diagram power supply: PS11

Read out CCU diagnostic memory.


Analyze diagnostic environment of the diagnostic entry.
The error word shows, which issues have led to the diagnostic entry.

Check always hardware of the I/O module:


- Are all L_Bus cables plugged correctly? Repress the plugs of the L_Bus cables accurately.
The plugs do lock in place late.
- Is there a damage on the L_Bus cable? The shielding should not be damaged in any way.
- Is the wiring of the I/O modules correct (inputs, outputs, power supply)?
- Are all plugs of the I/O module fitted correctly?
- Is the shielding of the MVB-cable, shielding of other cables and the grounding carried out
correctly?

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E112 E112

Condition:

Criteria
- IO module E112_02 reports a hardware error.
Issues can be:
- General status faulty
- Error on L_Bus
- NSDB Error
- Component Error
- Sink Port Error
- Watchdog Error

Reaction:
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 367/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.193 CCU Fault Code 1338
Ext.IO 11: E112_03 Hardware error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1338

General information:
I/O Module: EA112 (EA112_03)
Circuit diagram power supply: PS11

Read out CCU diagnostic memory.


Analyze diagnostic environment of the diagnostic entry.
The error word shows, which issues have led to the diagnostic entry.

Check always hardware of the I/O module:


- Are all L_Bus cables plugged correctly? Repress the plugs of the L_Bus cables accurately.
The plugs do lock in place late.
- Is there a damage on the L_Bus cable? The shielding should not be damaged in any way.
- Is the wiring of the I/O modules correct (inputs, outputs, power supply)?
- Are all plugs of the I/O module fitted correctly?
- Is the shielding of the MVB-cable, shielding of other cables and the grounding carried out
correctly?

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E112 E112

Condition:

Criteria
- IO module E112_03 reports a hardware error.
Issues can be:
- General status faulty
- Error on L_Bus
- NSDB Error
- Component Error
- Sink Port Error
- Watchdog Error

Reaction:
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 368/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.194 CCU Fault Code 1339
Ext.IO 11: E113_00 Short circuit detected

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1339

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 3
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 3 output E113_00
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 3 I/O station 11 module 3
(E113) contact 411.JG/18 for short
on I/O station 11. circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 369/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E113 E113

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 3 of IO station 11.

Reaction:
- Fault code triggered
- 0th Channel of module 3 of station 11 detected a short circuit.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 370/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.195 CCU Fault Code 1340
Ext.IO 11: E113_01 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1340

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 3
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 3 output E113_01
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 3 I/O station 11 module 3
(E113) contact 411.JG/9 for short
on I/O station 11. circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 371/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E113 E113

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 3 of IO station 11.

Reaction:
- Fault code triggered
- 1st Channel of module 3 of station 11 detected a short circuit.
- Module 3 on I/O station 11 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 372/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.196 CCU Fault Code 1341
Ext.IO 11: E113_02 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1341

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 3
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 3 output E113_02
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 3 I/O station 11 module 3
(E113) contact 411.JG/19 for short
on I/O station 11. circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 373/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E113 E113

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 3 of IO station 11.

Reaction:
- Fault code triggered
- 2nd Channel of module 3 of station 11 detected a short circuit.
- Module 3 on I/O station 11 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 374/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.197 CCU Fault Code 1342
Ext.IO 11: E113_03 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1342

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 3
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 3 output E113_03
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 3 I/O station 11 module 3
(E113) contact 411.JG/20 for short
on I/O station 11. circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 375/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E113 E113

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 3 of IO station 11.

Reaction:
- Fault code triggered
- 3rd Channel of module 3 of station 11 detected a short circuit.
- Module 3 on I/O station 11 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 376/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.198 CCU Fault Code 1343
Ext.IO 11: E113_04 Short circuit detected

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1343

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 3
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 3 output E113_04
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 3 I/O station 11 module 3
(E113) contact 411.OG/14 for short
on I/O station 11. circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 377/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E113 E113

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 3 of IO station 11.

Reaction:
- Fault code triggered
- 4th Channel of module 3 of station 11 detected a short circuit.
- Module 3 on I/O station 11 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 378/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.199 CCU Fault Code 1344
Ext.IO 11: E113_05 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1344

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 3
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 3 output E113_05
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 3 I/O station 11 module 3
(E113) contact 411.OG/3 for short
on I/O station 11. circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 379/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E113 E113

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 3 of IO station 11.

Reaction:
- Fault code triggered
- 5th Channel of module 3 of station 11 detected a short circuit.
- Module 3 on I/O station 11 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 380/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.200 CCU Fault Code 1345
Ext.IO 11: E113_06 Short circuit detected

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1345

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 3
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 3 output E113_06
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 3 I/O station 11 module 3
(E113) contact 411.JJ/13 for short
on I/O station 11. circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 381/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E113 E113

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 3 of IO station 11.

Reaction:
- Fault code triggered
- 6th Channel of module 3 of station 11 detected a short circuit.
- Module 3 on I/O station 11 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 382/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.201 CCU Fault Code 1346
Ext.IO 11: E113_07 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1346

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 3
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 3 output E113_07
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 3
I/O station 11 module 3, Pin
(E113)
Q8, for short circuit
on I/O station 11.

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 383/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E113 E113

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 3 of IO station 11.

Reaction:
- Fault code triggered
- 7th Channel of module 3 of station 11 detected a short circuit.
- Module 3 on I/O station 11 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 384/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.202 CCU Fault Code 1347
Ext.IO 11: E114_00 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1347

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 4 output E114_00
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 11 module 4
(E114) contact 411.LG/14(Pin Q1)
on I/O station 11. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 385/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E114 E114

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 4 of IO station 11.

Reaction:
- Fault code triggered
- 0th Channel of module 4 of station 11 detected a short circuit.
- Module 4 on I/O station 11 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 386/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.203 CCU Fault Code 1348
Ext.IO 11: E114_01 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1348

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 4 output E114_01
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 11 module 4
(E114) contact 411.LJ/2(Pin Q2)
on I/O station 11. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 387/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E114 E114

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 4 of IO station 11.

Reaction:
- Fault code triggered
- 1st Channel of module 4 of station 11 detected a short circuit.
- Module 4 on I/O station 11 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 388/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.204 CCU Fault Code 1349
Ext.IO 11: E114_02 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1349

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 4 output E114_02
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 11 module 4
(E114) contact 411.LG/7(Pin Q3)
on I/O station 11. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 389/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E114 E114

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 4 of IO station 11.

Reaction:
- Fault code triggered
- 2nd Channel of module 4 of station 11 detected a short circuit.
- Module 4 on I/O station 11 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 390/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.205 CCU Fault Code 1350
Ext.IO 11: E114_03 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1350

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 4 output E114_03
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 11 module 4
(E114) contact 411.LG/18(Pin Q4)
on I/O station 11. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 391/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E114 E114

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 4 of IO station 11.

Reaction:
- Fault code triggered
- 4th Channel of module 4 of station 11 detected a short circuit.
- Module 4 on I/O station 11 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 392/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.206 CCU Fault Code 1351
Ext.IO 11: E114_04 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1351

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 4 output E114_04
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 11 module 4
(E114) contact 411.RC/1(Pin Q5)
on I/O station 11. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 393/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E114 E114

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 4 of IO station 11.

Reaction:
- Fault code triggered
- 5th Channel of module 4 of station 11 detected a short circuit.
- Module 4 on I/O station 11 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 394/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.207 CCU Fault Code 1352
Ext.IO 11: E114_05 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1352

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 4 output E114_05
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 11 module 4
(E114) contact 411.RC/2(Pin Q6)
on I/O station 11. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 395/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E114 E114

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 4 of IO station 11.

Reaction:
- Fault code triggered
- 6th Channel of module 4 of station 11 detected a short circuit.
- Module 4 on I/O station 11 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 396/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.208 CCU Fault Code 1353
Ext.IO 11: E114_06 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1353

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 4 output E114_06
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 11 module 4
(E114) contact 411.RC/3(Pin Q7)
on I/O station 11. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 397/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E114 E114

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 4 of IO station 11.

Reaction:
- Fault code triggered
- 6th Channel of module 4 of station 11 detected a short circuit.
- Module 4 on I/O station 11 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 398/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.209 CCU Fault Code 1354
Ext.IO 11: E114_07 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1354

Switch I/O station 11


(use CB I/O station 11, 127.9/1),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 11 (127.9/1) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 11
module 4 output E114_07
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 11 module 4
(E114) contact 411.RC/4(Pin Q8)
on I/O station 11. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 399/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 11 E114 E114

Condition:
- MVB Communication between CCU and I/O station 11 is Ok

Criteria:
- short circuit detected in module 4 of IO station 11.

Reaction:
- Fault code triggered
- 7th Channel of module 4 of station 11 detected a short circuit.
- Module 4 on I/O station 11 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 400/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.210 CCU Fault Code 1355
Ext.IO 12: E124_00 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1355

Switch I/O station 12


(use CB I/O station 12, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 12 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 4 output E124_00
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 12 module 4
(E124) contact 411.LG/17(Pin Q1)
on I/O station 12. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 401/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E124 E124

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 4 of IO station 12.

Reaction:
- Fault code triggered
- 0th Channel of module 4 of station 12 detected a short circuit.
- Module 4 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 402/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.211 CCU Fault Code 1356
Ext.IO 12: E124_01 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1356

Switch I/O station 12


(use CB I/O station 12, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 12 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 4 output E124_01
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 12 module 4
(E124) contact 411.JG/23(Pin Q2)
on I/O station 12. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 403/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E124 E124

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 4 of IO station 12.

Reaction:
- Fault code triggered
- 1st Channel of module 4 of station 12 detected a short circuit.
- Module 4 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 404/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.212 CCU Fault Code 1357
Ext.IO 12: E124_02 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1357

Switch I/O station 12


(use CB I/O station 12, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 12 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 4 output E124_02
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 12 module 4
(E124) contact 411.OG/14(Pin Q3)
on I/O station 12. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 405/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E124 E124

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 4 of IO station 12.

Reaction:
- Fault code triggered
- 2nd Channel of module 4 of station 12 detected a short circuit.
- Module 4 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 406/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.213 CCU Fault Code 1358
Ext.IO 12: E124_03 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1358

Switch I/O station 12


(use CB I/O station 12, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 12 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 4 output E124_03
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 12 module 4
(E124) contact 411.OG/3(Pin Q4)
on I/O station 12. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 407/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E124 E124

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 4 of IO station 12.

Reaction:
- Fault code triggered
- 3rd Channel of module 4 of station 12 detected a short circuit.
- Module 4 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 408/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.214 CCU Fault Code 1359
Ext.IO 12: E124_04 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1359

Switch I/O station 12


(use CB I/O station 11, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 11 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 4 output E124_04
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 12 module 4
(E124) contact 411.OG/19 (Pin Q5)
on I/O station 12. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 409/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E124 E124

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 4 of IO station 12.

Reaction:
- Fault code triggered
- 5th Channel of module 4 of station 12 detected a short circuit.
- Module 4 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 410/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.215 CCU Fault Code 1360
Ext.IO 12: E124_05 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1360

Switch I/O station 12


(use CB I/O station 11, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 11 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 4 output E124_05
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 12 module 4
(E124) contact 411.OG/20(Pin Q6)
on I/O station 12. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 411/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E124 E124

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 4 of IO station 12.

Reaction:
- Fault code triggered
- 5th Channel of module 4 of station 12 detected a short circuit.
- Module 4 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 412/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.216 CCU Fault Code 1361
Ext.IO 12: E124_06 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1361

Switch I/O station 12


(use CB I/O station 11, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 11 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 4 output E124_06
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 12 module 4
(E124) contact (Pin Q7) for short
on I/O station 12. circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 413/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E124 E124

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 4 of IO station 12.

Reaction:
- Fault code triggered
- 6th Channel of module 4 of station 12 detected a short circuit.
- Module 4 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 414/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.217 CCU Fault Code 1362
Ext.IO 12: E124_07 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1362

Switch I/O station 12


(use CB I/O station 12, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 12 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 4 output E124_07
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 12 module 4
(E124) contact (Pin Q8) for short
on I/O station 12. circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 415/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E124 E124

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 4 of IO station 12.

Reaction:
- Fault code triggered
- 7th Channel of module 4 of station 12 detected a short circuit.
- Module 4 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 416/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.218 CCU Fault Code 1363
Ext.IO 12: E125_00 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1363

Switch I/O station 12


(use CB I/O station 12, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 12 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 4 output E125_00
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 12 module 5
(E125) contact (Pin Q1, 411.OJ/9)
on I/O station 12. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 417/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E125 E125

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 5 of IO station 12.

Reaction:
- Fault code triggered
- 0th Channel of module 7 of station 12 detected a short circuit.
- Module 5 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 418/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.219 CCU Fault Code 1364
Ext.IO 12: E125_01 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1364

Switch I/O station 12


(use CB I/O station 12, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 12 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 5 output E125_01
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 12 module 5
(E125) contact (Pin Q2, 411.OJ/3)
on I/O station 12. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 419/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E125 E125

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 5 of IO station 12.

Reaction:
- Fault code triggered
- 1st Channel of module 5 of station 12 detected a short circuit.
- Module 5 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 420/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.220 CCU Fault Code 1365
Ext.IO 12: E125_02 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1365

Switch I/O station 12


(use CB I/O station 12, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 12 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 5 output E125_02
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 12 module 5
(E125) contact (Pin Q3, 411.QJ/3)
on I/O station 12. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 421/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E125 E125

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 5 of IO station 12.

Reaction:
- Fault code triggered
- 2nd Channel of module 5 of station 12 detected a short circuit.
- Module 5 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 422/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.221 CCU Fault Code 1366
Ext.IO 12: E125_03 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1366

Switch I/O station 12


(use CB I/O station 12, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 12 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 5 output E125_03
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 12 module 5
(E125) contact (Pin Q4, 411.LG/7)
on I/O station 12. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 423/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E125 E125

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 5 of IO station 12.

Reaction:
- Fault code triggered
- 3rd Channel of module 5 of station 12 detected a short circuit.
- Module 5 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 424/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.222 CCU Fault Code 1367
Ext.IO 12: E125_04 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1367

Switch I/O station 12


(use CB I/O station 12, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 12 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 5 output E125_04
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 12 module 5
(E125) contact (Pin Q5, 411.RC/1)
on I/O station 12. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 425/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E125 E125

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 5 of IO station 12.

Reaction:
- Fault code triggered
- 4th Channel of module 5 of station 12 detected a short circuit.
- Module 5 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 426/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.223 CCU Fault Code 1368
Ext.IO 12: E125_05 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1368

Switch I/O station 12


(use CB I/O station 12, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 12 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 5 output E125_05
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 12 module 5
(E125) contact (Pin Q6, 411.RC/2)
on I/O station 12. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 427/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E125 E125

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 5 of IO station 12.

Reaction:
- Fault code triggered
- 5th Channel of module 5 of station 12 detected a short circuit.
- Module 5 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 428/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.224 CCU Fault Code 1369
Ext.IO 12: E125_06 Short circuit detected

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1369

Switch I/O station 12


(use CB I/O station 12, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 12 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 5 output E125_06
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 12 module 5
(E125) contact (Pin Q7, 411.RC/3)
on I/O station 12. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 429/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E125 E125

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 5 of IO station 12.

Reaction:
- Fault code triggered
- 6th Channel of module 5 of station 12 detected a short circuit.
- Module 5 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 430/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.225 CCU Fault Code 1370
Ext.IO 12: E125_07 Short circuit detected

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1370

Switch I/O station 12


(use CB I/O station 12, 127.9/2),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 12 (127.9/2) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 12
module 5 output E125_07
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 12 module 5
(E125) contact (Pin Q8, 411.RC/4)
on I/O station 12. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 431/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 12 E125 E125

Condition:
- MVB Communication between CCU and I/O station 12 is Ok

Criteria:
- short circuit detected in module 5 of IO station 12.

Reaction:
- Fault code triggered
- 7th Channel of module 5 of station 12 detected a short circuit.
- Module 5 on I/O station 12 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 432/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.226 CCU Fault Code 1371
Ext.IO 21: E213_00 Input voltage below or above limit values
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1371

Check the connector 412.EA/5 and


412.EA/9.
If not connected connect it. If it is
connected already then check whether
its connected properly or not and also
check whether it is connected to correct
pin in AI module EA213_00

Code
still triggered in Yes
CCU?

Check and replace wiring

No

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E213 E213

Condition:

Criteria
- The message is triggered every 2s if no lines are connected to the lutze inputs. E.g.
corresponding plug outside the VCU box not plugged in.

Reaction:
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 433/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.227 CCU Fault Code 1372
Ext.IO 21: E213_01 Input voltage below or above limit values
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1372

Check the connector 412.EC/1 and


412.EC/6.
If not connected connect it. If it is
connected already then check whether
its connected properly or not and also
check whether it is connected to correct
pin in AI module EA213_01

Code
still triggered in Yes
CCU?

Check and replace wiring

No

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E213 E213

Condition:

Criteria
- The message is triggered every 2s if no lines are connected to the lutze inputs. E.g.
corresponding plug outside the VCU box not plugged in.

Reaction:
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 434/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.228 CCU Fault Code 1373
Ext.IO 21: E213_02 Input voltage below or above limit values
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1373

Check corresponding connector and


input connections.
If plug not connected connect it. If it is
connected already then check whether
its connected properly or not and also
check whether it is connected to correct
pin in AI module EA213_02

Code
still triggered in Yes
CCU?

Check and replace wiring

No

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E213 E213

Condition:

Criteria
- The message is triggered every 2s if no lines are connected to the lutze inputs. E.g.
corresponding plug outside the VCU box not plugged in.

Reaction:
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 435/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.229 CCU Fault Code 1374
Ext.IO 21: E213_03 Input voltage below or above limit values
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1374

Check corresponding connector and


input connections.
If plug not connected connect it. If it is
connected already then check whether
its connected properly or not and also
check whether it is connected to correct
pin in AI module EA213_03

Code
still triggered in Yes
CCU?

Check and replace wiring

No

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E213 E213

Condition:

Criteria
- The message is triggered every 2s if no lines are connected to the lutze inputs. E.g.
corresponding plug outside the VCU box not plugged in.

Reaction:
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 436/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.230 CCU Fault Code 1375
Ext.IO 21: E213_00 Hardware error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1375

General information:
I/O Module: EA112 (E213_00)
Circuit diagram power supply: PS21

Read out CCU diagnostic memory.


Analyze diagnostic environment of the diagnostic entry.
The error word shows, which issues have led to the diagnostic entry.

Check always hardware of the I/O module:


- Are all L_Bus cables plugged correctly? Repress the plugs of the L_Bus cables accurately.
The plugs do lock in place late.
- Is there a damage on the L_Bus cable? The shielding should not be damaged in any way.
- Is the wiring of the I/O modules correct (inputs, outputs, power supply)?
- Are all plugs of the I/O module fitted correctly?
- Is the shielding of the MVB-cable, shielding of other cables and the grounding carried out
correctly?

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E213 E213

Condition:

Criteria
- IO module E213_00 reports a hardware error. Issues can be:
- General status faulty
- Error on L_Bus
- NSDB Error
- Component Error
- Sink Port Error
- Watchdog Error

Reaction:
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 437/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.231 CCU Fault Code 1376
Ext.IO 21: E213_01 Hardware error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1376

General information:
I/O Module: EA112 (E213_01)
Circuit diagram power supply: PS21

Read out CCU diagnostic memory.


Analyze diagnostic environment of the diagnostic entry.
The error word shows, which issues have led to the diagnostic entry.

Check always hardware of the I/O module:


- Are all L_Bus cables plugged correctly? Repress the plugs of the L_Bus cables accurately.
The plugs do lock in place late.
- Is there a damage on the L_Bus cable? The shielding should not be damaged in any way.
- Is the wiring of the I/O modules correct (inputs, outputs, power supply)?
- Are all plugs of the I/O module fitted correctly?
- Is the shielding of the MVB-cable, shielding of other cables and the grounding carried out
correctly?

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E213 E213

Condition:

Criteria
- IO module E213_01 reports a hardware error. Issues can be:
- General status faulty
- Error on L_Bus
- NSDB Error
- Component Error
- Sink Port Error
- Watchdog Error

Reaction:
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 438/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.232 CCU Fault Code 1377
Ext.IO 21: E213_02 Hardware error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1377

General information:
I/O Module: EA112 (E213_02)
Circuit diagram power supply: PS21

Read out CCU diagnostic memory.


Analyze diagnostic environment of the diagnostic entry.
The error word shows, which issues have led to the diagnostic entry.

Check always hardware of the I/O module:


- Are all L_Bus cables plugged correctly? Repress the plugs of the L_Bus cables accurately.
The plugs do lock in place late.
- Is there a damage on the L_Bus cable? The shielding should not be damaged in any way.
- Is the wiring of the I/O modules correct (inputs, outputs, power supply)?
- Are all plugs of the I/O module fitted correctly?
- Is the shielding of the MVB-cable, shielding of other cables and the grounding carried out
correctly?

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E213 E213

Condition:

Criteria
- IO module E213_02 reports a hardware error.
Issues can be:
- General status faulty
- Error on L_Bus
- NSDB Error
- Component Error
- Sink Port Error
- Watchdog Error
Reaction:
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 439/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.233 CCU Fault Code 1378
Ext.IO 21: E213_03 Hardware error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1378

General information:
I/O Module: EA112 (E213_03)
Circuit diagram power supply: PS21

Read out CCU diagnostic memory.


Analyze diagnostic environment of the diagnostic entry.
The error word shows, which issues have led to the diagnostic entry.

Check always hardware of the I/O module:


- Are all L_Bus cables plugged correctly? Repress the plugs of the L_Bus cables accurately.
The plugs do lock in place late.
- Is there a damage on the L_Bus cable? The shielding should not be damaged in any way.
- Is the wiring of the I/O modules correct (inputs, outputs, power supply)?
- Are all plugs of the I/O module fitted correctly?
- Is the shielding of the MVB-cable, shielding of other cables and the grounding carried out
correctly?

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E213 E213

Condition:

Criteria
- IO module E213_03 reports a hardware error.
Issues can be:
- General status faulty
- Error on L_Bus
- NSDB Error
- Component Error
- Sink Port Error
- Watchdog Error
Reaction:
- Fault code triggered
Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 440/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.234 CCU Fault Code 1379
Ext.IO 21: E214_00 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1379

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 4 output E214_00
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 21 module 4
(E214) contact (Pin Q1, 412.JG/18)
on I/O station 21. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 441/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E214 E214

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 4 of IO station 21.

Reaction:
- Fault code triggered
- 0th Channel of module 4 of station 21 detected a short circuit.
- Module 4 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 442/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.235 CCU Fault Code 1380
Ext.IO 21: E214_01 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1380

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 4 output E214_01
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 21 module 4
(E214) contact (Pin Q2, 412.JG/9)
on I/O station 21. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 443/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E214 E214

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 4 of IO station 21.

Reaction:
- Fault code triggered
- 1st Channel of module 4 of station 21 detected a short circuit.
- Module 4 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 444/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.236 CCU Fault Code 1381
Ext.IO 21: E214_02 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1381

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 4 output E214_02
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 21 module 4
(E214) contact (Pin Q3, 412.JG/19)
on I/O station 21. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 445/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E214 E214

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 4 of IO station 21.

Reaction:
- Fault code triggered
- 2nd Channel of module 4 of station 21 detected a short circuit.
- Module 4 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 446/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.237 CCU Fault Code 1382
Ext.IO 21: E214_03 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1382

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 4 output E214_03
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 21 module 4
(E214) contact (Pin Q4, 412.JG/20)
on I/O station 21. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 447/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E214 E214

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 4 of IO station 21.

Reaction:
- Fault code triggered
- 3rd Channel of module 4 of station 21 detected a short circuit.
- Module 4 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 448/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.238 CCU Fault Code 1383
Ext.IO 21: E214_04 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1383

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 4 output E214_04
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 21 module 4
(E214) contact (Pin Q5,412.OG/14)
on I/O station 21. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 449/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E214 E214

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 4 of IO station 21.

Reaction:
- Fault code triggered
- 4th Channel of module 4 of station 21 detected a short circuit.
- Module 4 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 450/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.239 CCU Fault Code 1384
Ext.IO 21: E214_05 Short circuit detected

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1384

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 4 output E214_05
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 21 module 4
(E214) contact (Pin Q6, 412.OG/3)
on I/O station 21. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 451/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E214 E214

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 4 of IO station 21.

Reaction:
- Fault code triggered
- 6th Channel of module 4 of station 21 detected a short circuit.
- Module 4 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 452/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.240 CCU Fault Code 1385
Ext.IO 21: E214_06 Short circuit detected

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1385

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 4 output E214_06
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 21 module 4
(E214) contact (Pin Q7, 412.JG/15)
on I/O station 21. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 453/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E214 E214

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 4 of IO station 21.

Reaction:
- Fault code triggered
- 6th Channel of module 4 of station 21 detected a short circuit.
- Module 4 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 454/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.241 CCU Fault Code 1386
Ext.IO 21: E214_07 Short circuit detected

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1386

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 4 output E214_07
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 21 module 4
(E214) contact (Pin Q8) for short
on I/O station 21. circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 455/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E214 E214

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 4 of IO station 21.

Reaction:
- Fault code triggered
- 7th Channel of module 4 of station 21 detected a short circuit.
- Module 4 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 456/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.242 CCU Fault Code 1387
Ext.IO 21: E215_00 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1387

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 5 output E215_00
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 21 module 5
(E215) contact (Pin Q1, 412.JJ/12)
on I/O station 21. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 457/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E215 E215

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 5 of IO station 21.

Reaction:
- Fault code triggered
- 0th Channel of module 5 of station 21 detected a short circuit.
- Module 5 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 458/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.243 CCU Fault Code 1388
Ext.IO 21: E215_01 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1388

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 5 output E215_01
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 21 module 5
(E215) contact (Pin Q2, 412.OJ/13)
on I/O station 21. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 459/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E215 E215

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 5 of IO station 21.

Reaction:
- Fault code triggered
- 1st Channel of module 5 of station 21 detected a short circuit.
- Module 5 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 460/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.244 CCU Fault Code 1389
Ext.IO 21: E215_02 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1389

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 5 output E215_02
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 21 module 5
(E215) contact (Pin Q3, 412.QG/
on I/O station 21. 17) for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 461/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E215 E215

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 5 of IO station 21.

Reaction:
- Fault code triggered
- 2nd Channel of module 5 of station 21 detected a short circuit.
- Module 5 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 462/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.245 CCU Fault Code 1390
Ext.IO 21: E215_03 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1390

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 5 output E215_03
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 21 module 5
(E215) contact (Pin Q4, 412.QG/
on I/O station 21. 12) for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 463/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E215 E215

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 5 of IO station 21.

Reaction:
- Fault code triggered
- 3rd Channel of module 5 of station 21 detected a short circuit.
- Module 5 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 464/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.246 CCU Fault Code 1391
Ext.IO 21: E215_04 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1391

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 5 output E215_04
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 21 module 5
(E215) contact (Pin Q5, 412.LJ/3)
on I/O station 21. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 465/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E215 E215

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 5 of IO station 21.

Reaction:
- Fault code triggered
- 4th Channel of module 5 of station 21 detected a short circuit.
- Module 5 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 466/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.247 CCU Fault Code 1392
Ext.IO 21: E215_05 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1392

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 5 output E215_05
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 21 module 5
(E215) contact (Pin Q6, 412.LJ/12)
on I/O station 21. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 467/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E215 E215

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 5 of IO station 21.

Reaction:
- Fault code triggered
- 5th Channel of module 5 of station 21 detected a short circuit.
- Module 5 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 468/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.248 CCU Fault Code 1393
Ext.IO 21: E215_06 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1393

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 5 output E215_06
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 21 module 5
(E215) contact (Pin Q7, 412.QG/
on I/O station 21. 18) for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 469/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E215 E215

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 5 of IO station 21.

Reaction:
- Fault code triggered
- 6th Channel of module 5 of station 21 detected a short circuit.
- Module 5 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 470/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.249 CCU Fault Code 1394
Ext.IO 21: E215_07 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1387

Switch I/O station 21


(use CB I/O station 21, 127.9/3),
check correctness of serial Bus connector
and front connectors
on module 5
and switch I/O station 21 (127.9/3) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 21
module 5 output E215_07
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 5 I/O station 21 module 5
(E215) contact (Pin Q8, 412.QG/
on I/O station 21. 22) for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 471/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 21 E215 E215

Condition:
- MVB Communication between CCU and I/O station 21 is Ok

Criteria:
- short circuit detected in module 5 of IO station 21.

Reaction:
- Fault code triggered
- 7th Channel of module 5 of station 21 detected a short circuit.
- Module 5 on I/O station 21 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 472/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.250 CCU Fault Code 1395
Ext.IO 22: E224_00 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1395

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 4 output E224_00
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 22 module 4
(E224) contact (Pin Q1, 412.JJ/13)
on I/O station 22. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 473/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E224 E224

Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 4 of IO station 22.

Reaction:
- Fault code triggered
- 0th Channel of module 4 of station 22 detected a short circuit.
- Module 4 on I/O station 22 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 474/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.251 CCU Fault Code 1396
Ext.IO 22: E224_01 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1396

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 4 output E224_01
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 22 module 4
(E224) contact (Pin Q2, 412.JG/23)
on I/O station 22. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 475/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E224 E224

Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 4 of IO station 22.

Reaction:
- Fault code triggered
- 1st Channel of module 4 of station 22 detected a short circuit.
- Module 4 on I/O station 22 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 476/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.252 CCU Fault Code 1397
Ext.IO 22: E224_02 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1397

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 4 output E224_02
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 22 module 4
(E224) contact (Pin Q3, 412.OG/
on I/O station 22. 14) for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 477/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E224 E224

Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 4 of IO station 22.

Reaction:
- Fault code triggered
- 2nd Channel of module 4 of station 22 detected a short circuit.
- Module 4 on I/O station 22 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 478/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.253 CCU Fault Code 1398
Ext.IO 22: E224_03 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1398

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 4 output E224_03
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 22 module 4
(E224) contact (Pin Q4, 412.OG/3)
on I/O station 22. for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 479/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E224 E224

Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 4 of IO station 22.

Reaction:
- Fault code triggered
- 3rd Channel of module 4 of station 22 detected a short circuit.
- Module 4 on I/O station 22 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 480/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.254 CCU Fault Code 1399
Ext.IO 22: E224_04 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1399

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 4 output E224_04
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 22 module 4
(E224) contact (Pin Q5, 412.OG/
on I/O station 22. 19) for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 481/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E224 E224

Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 4 of IO station 22.

Reaction:
- Fault code triggered
- 4th Channel of module 4 of station 22 detected a short circuit.
- Module 4 on I/O station 22 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 482/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.255 CCU Fault Code 1400
Ext.IO 22: E224_05 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1400

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 4 output E224_05
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 22 module 4
(E224) contact (Pin Q6, 412.OG/
on I/O station 22. 20) for short circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 483/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E224 E224

Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 4 of IO station 22.

Reaction:
- Fault code triggered
- 5th Channel of module 4 of station 22 detected a short circuit.
- Module 4 on I/O station 22 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 484/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.256 CCU Fault Code 1401
Ext.IO 22: E224_06 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:
Code = 1401

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 4 output E224_06
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 22 module 4
(E224) contact (Pin Q7) for short
on I/O station 22. circuit

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 485/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E224 E224

Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 4 of IO station 22.

Reaction:
- Fault code triggered
- 6th Channel of module 4 of station 22 detected a short circuit.
- Module 4 on I/O station 22 is inoperative.

Related messages:
-

3.2.257 CCU Fault Code 1402


Ext.IO 22: E224_07 Short circuit detected

Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 486/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 1402

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 4
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 4 output E224_07
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 4 I/O station 22 module 4
(E224) contact (Pin Q8) for short
on I/O station 22. circuit

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E224 E224

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 487/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 4 of IO station 22.

Reaction:
- Fault code triggered
- 7th Channel of module 4 of station 22 detected a short circuit.
- Module 4 on I/O station 22 is inoperative.

Related messages:
-

3.2.258 CCU Fault Code 1403


Ext.IO 22: E226_00 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 488/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 1403

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 6
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 6 output E226_00
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 6 I/O station 22 module 6
(E226) contact (Pin Q1,412.QG/14)
on I/O station 22. for short circuit

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E226 E226

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 489/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 6 of IO station 22.

Reaction:
- Fault code triggered
- 0th Channel of module 6 of station 22 detected a short circuit.
- Module 6 on I/O station 22 is inoperative.

Related messages:
-

3.2.259 CCU Fault Code 1404


Ext.IO 22: E226_01 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 490/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 1404

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 6
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 6 output E226_01
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 6 I/O station 22 module 6
(E226) contact (Pin Q2,412.QG/3)
on I/O station 22. for short circuit

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E226 E226

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 491/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 6 of IO station 22.

Reaction:
- Fault code triggered
- 1st Channel of module 6 of station 22 detected a short circuit.
- Module 6 on I/O station 22 is inoperative.

Related messages:
-

3.2.260 CCU Fault Code 1405


Ext.IO 22: E226_02 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 492/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 1405

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 6
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 6 output E226_02
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 6 I/O station 22 module 6
(E226) contact (Pin Q3,412.QG/17)
on I/O station 22. for short circuit

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E226 E226

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 493/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 6 of IO station 22.

Reaction:
- Fault code triggered
- 2nd Channel of module 6 of station 22 detected a short circuit.
- Module 6 on I/O station 22 is inoperative.

Related messages:
-

3.2.261 CCU Fault Code 1406


Ext.IO 22: E226_03 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 494/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 1406

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 6
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 6 output E226_03
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 6 I/O station 22 module 6
(E226) contact (Pin Q4, 412.QG/
on I/O station 22. 12) for short circuit

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E226 E226

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 495/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 6 of IO station 22.

Reaction:
- Fault code triggered
- 3rd Channel of module 6 of station 22 detected a short circuit.
- Module 6 on I/O station 22 is inoperative.

Related messages:
-

3.2.262 CCU Fault Code 1407


Ext.IO 22: E226_04 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 496/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 1407

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 6
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 6 output E226_04
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 6 I/O station 22 module 6
(E226) contact (Pin Q5,412.QG/18)
on I/O station 22. for short circuit

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E226 E226

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 497/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 6 of IO station 22.

Reaction:
- Fault code triggered
- 4th Channel of module 6 of station 22 detected a short circuit.
- Module 6 on I/O station 22 is inoperative.

Related messages:
-

3.2.263 CCU Fault Code 1408


Ext.IO 22: E226_05 Short circuit detected
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 498/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 1408

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 6
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 6 output E226_05
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 6 I/O station 22 module 6
(E226) contact (Pin Q6,412.QG/22)
on I/O station 22. for short circuit

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E226 E226

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 499/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 6 of IO station 22.

Reaction:
- Fault code triggered
- 5th Channel of module 6 of station 22 detected a short circuit.
- Module 6 on I/O station 22 is inoperative.

Related messages:
-

3.2.264 CCU Fault Code 1409


Ext.IO 22: E226_06 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 500/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 1409

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 6
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 6 output E226_06
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 6 I/O station 22 module 6
(E226) contact (Pin Q7,412.OJ/12)
on I/O station 22. for short circuit

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E226 E226

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 501/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 6 of IO station 22.

Reaction:
- Fault code triggered
- 6th Channel of module 6 of station 22 detected a short circuit.
- Module 6 on I/O station 22 is inoperative.

Related messages:
-

3.2.265 CCU Fault Code 1410


Ext.IO 22: E226_07 Short circuit detected
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 502/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 1410

Switch I/O station 22


(use CB I/O station 22, 127.9/4),
check correctness of serial Bus connector
and front connectors
on module 6
and switch I/O station 22 (127.9/4) on again

Code
still triggered in Yes
CCU?

Check on TOD short circuit


status of I/O station 22
module 6 output E226_07
(see menu short diagnosis).

Is this output have a


Yes
short circuit?

No No

Check circuits connected to


Exchange module 6 I/O station 22 module 6
(E226) contact (Pin Q8, 412.OJ/13)
on I/O station 22. for short circuit

End

Components concerned:
Component Device name CCU1 Device name CCU2
I/O station 22 E226 E226

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 503/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
- MVB Communication between CCU and I/O station 22 is Ok

Criteria:
- short circuit detected in module 6 of IO station 22.

Reaction:
- Fault code triggered
- 7th Channel of module 6 of station 22 detected a short circuit.
- Module 6 on I/O station 22 is inoperative.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 504/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.266 CCU Fault Code 1411
G111_01/121_15 Redundancy error
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1411

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E111_01 and E121_15. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E111 E111
IO station 12 E121 E121

Condition:

Criteria
- Feedback received on digital input E111_01 and E121_15 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 505/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.267 CCU Fault Code 1412
G111_05/122_14 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1412

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E111_05 and E122_14. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E111 E111
IO station 12 E122 E122

Condition:

Criteria
- Feedback received on digital input E111_05 and E122_14 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 506/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.268 CCU Fault Code 1413
E111_03/121_07 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1413

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E111_03 and E121_07. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E111 E111
IO station 12 E121 E121

Condition:

Criteria
- Feedback received on digital input E111_03 and E121_07 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 507/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.269 CCU Fault Code 1414
E111_07/121_00 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1414

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E111_07 and E121_00. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E111 E111
IO station 12 E121 E121

Condition:

Criteria
- Feedback received on digital input E111_07 and E121_00 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 508/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.270 CCU Fault Code 1415
E111_09/122_12 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1415

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E111_09 and E122_12. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E111 E111
IO station 12 E122 E122

Condition:

Criteria
- Feedback received on digital input E111_09 and E122_12 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 509/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.271 CCU Fault Code 1416
E111_11/121_09 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1416

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E111_11 and E121_09. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E111 E111
IO station 12 E121 E121

Condition:

Criteria
- Feedback received on digital input E111_11 and E121_09 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 510/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.272 CCU Fault Code 1417
E111_12/121_06 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1417

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E111_12 and E121_06. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E111 E111
IO station 12 E121 E121

Condition:

Criteria
- Feedback received on digital input E111_12 and E121_06 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 511/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.273 CCU Fault Code 1418
E111_13/121_08 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1418

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E111_13 and E121_08. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E111 E111
IO station 12 E121 E121

Condition:

Criteria
- Feedback received on digital input E111_13 and E121_08 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 512/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.274 CCU Fault Code 1419
E111_14/121_14 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1419

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E111_14 and E121_14. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E111 E111
IO station 12 E121 E121

Condition:

Criteria
- Feedback received on digital input E111_14 and E121_14 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 513/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.275 CCU Fault Code 1420
E112_05/121_10 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1420

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E112_05 and E121_10. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E112 E112
IO station 12 E121 E121

Condition:

Criteria
- Feedback received on digital input E112_05 and E121_10 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 514/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.276 CCU Fault Code 1421
E112_01/122_11 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1421

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E112_01 and E122_11. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E112 E112
IO station 12 E122 E122

Condition:

Criteria
- Feedback received on digital input E111_01 and E122_11 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 515/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.277 CCU Fault Code 1422
E111_02/122_09 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1422

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E111_02 and E122_09. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E111 E111
IO station 12 E122 E122

Condition:

Criteria
- Feedback received on digital input E111_02 and E122_09 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 516/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.278 CCU Fault Code 1423
E112_04/121_12 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1423

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E112_04 and E121_12. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E112 E112
IO station 12 E121 E121

Condition:

Criteria
- Feedback received on digital input E112_04 and E121_12 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 517/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.279 CCU Fault Code 1424
E212_04/221_09 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1424

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E212_04 and E221_09. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E212 E212
IO station 22 E221 E221

Condition:

Criteria
- Feedback received on digital input E212_04 and E221_09 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 518/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.280 CCU Fault Code 1425
E212_15/221_12 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1425

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E212_15 and E221_12. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E212 E212
IO station 22 E221 E221

Condition:

Criteria
- Feedback received on digital input E212_15 and E221_12 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 519/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.281 CCU Fault Code 1426
E117_00/127_00 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1426

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E117_00 and E127_00. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:

Criteria
- Feedback received on digital input E117_00 and E127_00 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 520/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.282 CCU Fault Code 1427
E211_00/223_00 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1427

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E211_00 and E223_00. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E211 E211
IO station 22 E223 E223

Condition:

Criteria
- Feedback received on digital input E211_00 and E223_00 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 521/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.283 CCU Fault Code 1428
E211_04/223_01 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1428

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E211_04 and E223_01. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E211 E211
IO station 22 E223 E223

Condition:

Criteria
- Feedback received on digital input E211_04 and E223_01 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 522/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.284 CCU Fault Code 1429
E211_02/221_15 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1429

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E211_02 and E221_15. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E211 E211
IO station 22 E221 E221

Condition:

Criteria
- Feedback received on digital input E211_02 and E221_15 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 523/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.285 CCU Fault Code 1430
E211_06/222_10 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1430

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E211_06 and E222_10. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E211 E211
IO station 22 E222 E222

Condition:

Criteria
- Feedback received on digital input E211_06 and E222_10 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 524/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.286 CCU Fault Code 1431
E211_07/222_03 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1431

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E211_07 and E222_03. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E211 E211
IO station 22 E222 E222

Condition:

Criteria
- Feedback received on digital input E211_07 and E222_03 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 525/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.287 CCU Fault Code 1432
E211_09/221_08 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1432

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E211_09 and E221_08. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E211 E211
IO station 22 E221 E221

Condition:

Criteria
- Feedback received on digital input E211_09 and E221_08 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 526/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.288 CCU Fault Code 1433
E211_11/221_11 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1433

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E211_11 and E221_11. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E211 E211
IO station 22 E221 E221

Condition:

Criteria
- Feedback received on digital input E211_11 and E221_11 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 527/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.289 CCU Fault Code 1434
E211_15/222_02 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1434

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E211_15 and E222_02. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E211 E211
IO station 22 E222 E222

Condition:

Criteria
- Feedback received on digital input E211_15 and E222_02 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 528/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.290 CCU Fault Code 1435
E212_00/221_01 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1435

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E212_00 and E221_01. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E212 E212
IO station 22 E221 E221

Condition:

Criteria
- Feedback received on digital input E212_00 and E221_01 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 529/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.291 CCU Fault Code 1436
E212_01/221_07 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1436

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E212_01 and E221_07. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E212 E212
IO station 22 E221 E221

Condition:

Criteria
- Feedback received on digital input E212_01 and E221_07 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 530/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.292 CCU Fault Code 1437
E212_02/222_09 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1437

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E212_02 and E222_09. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E212 E212
IO station 22 E222 E222

Condition:

Criteria
- Feedback received on digital input E212_02 and E222_09 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 531/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.293 CCU Fault Code 1438
E212_03/222_14 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1438

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E212_03 and E222_14. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E212 E212
IO station 22 E222 E222

Condition:

Criteria
- Feedback received on digital input E212_03 and E222_14 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 532/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.294 CCU Fault Code 1439
E123_01/222_05 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1439

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E123_01 and E222_05. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 12 E123 E123
IO station 22 E222 E222

Condition:

Criteria
- Feedback received on digital input E123_01 and E222_05 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 533/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.295 CCU Fault Code 1440
E123_08/221_14 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1440

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E123_08 and E221_14. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 12 E123 E123
IO station 22 E221 E221

Condition:

Criteria
- Feedback received on digital input E123_08 and E221_14 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 534/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.296 CCU Fault Code 1441
E212_08/222_12 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1441

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E212_08 and E222_12. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E212 E212
IO station 22 E222 E222

Condition:

Criteria
- Feedback received on digital input E212_08 and E222_12 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 535/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.297 CCU Fault Code 1442
E212_10/222_07 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1442

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E212_10 and E222_07. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E212 E212
IO station 22 E222 E222

Condition:

Criteria
- Feedback received on digital input E212_10 and E222_07 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 536/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.298 CCU Fault Code 1443
E212_11/223_02 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1443

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E212_11 and E223_02. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E212 E212
IO station 22 E223 E223

Condition:

Criteria
- Feedback received on digital input E212_11 and E223_02 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 537/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.299 CCU Fault Code 1444
E212_12/223_13 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1444

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E212_12 and E223_13. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E212 E212
IO station 22 E223 E223

Condition:

Criteria
- Feedback received on digital input E212_12 and E223_13 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 538/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.300 CCU Fault Code 1445
E212_13/223_03 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1445

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E212_13 and E223_03. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E212 E212
IO station 22 E223 E223

Condition:

Criteria
- Feedback received on digital input E212_13 and E223_03 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 539/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.301 CCU Fault Code 1446
E212_14/222_01 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1446

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E212_14 and E222_01. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E212 E212
IO station 22 E222 E222

Condition:

Criteria
- Feedback received on digital input E212_14 and E222_01 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 540/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.302 CCU Fault Code 1447
E117_01/127_01 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1447

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E117_01 or E127_01. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:

Criteria
- Feedback received on digital input E117_01 and E127_01 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 541/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.303 CCU Fault Code 1449
E117_02/127_02 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1449

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E117_02 or E127_02. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:

Criteria
- Feedback received on digital input E117_02 and E127_02 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 542/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.304 CCU Fault Code 1450
E117_03/127_03 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1450

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E117_03 or E127_03. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:

Criteria
- Feedback received on digital input E117_03 and E127_03 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 543/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.305 CCU Fault Code 1451
E117_04/127_04 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1451

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E117_04 or E127_04. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:

Criteria
- Feedback received on digital input E117_04 and E127_04 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 544/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.306 CCU Fault Code 1452
E117_05/127_05 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1452

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E117_05 or E127_05. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:

Criteria
- Feedback received on digital input E117_05 and E127_05 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 545/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.307 CCU Fault Code 1453
E117_06/127_06 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1453

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E117_06 or E127_06. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:

Criteria
- Feedback received on digital input E117_06 and E127_06 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 546/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.308 CCU Fault Code 1454
E117_07/127_07 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1454

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E117_07 or E127_07. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:

Criteria
- Feedback received on digital input E117_07 and E127_07 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 547/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.309 CCU Fault Code 1455
E117_08/127_08 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1455

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E117_08 or E127_08. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:

Criteria
- Feedback received on digital input E117_08 and E127_08 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 548/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.310 CCU Fault Code 1456
E117_10/127_10 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1456

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E117_10 or E127_10. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:

Criteria
- Feedback received on digital input E117_10 and E127_10 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 549/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Related messages:
-

3.2.311 CCU Fault Code 1457


E117_11/127_11 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 550/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 1457

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E117_11 or E127_11. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:

Criteria
- Feedback received on digital input E117_11 and E127_11 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 551/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.312 CCU Fault Code 1458
E117_12/127_12 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1458

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E117_12 or E127_12. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:

Criteria
- Feedback received on digital input E117_12 and E127_12 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 552/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Related messages:
-

3.2.313 CCU Fault Code 1459


E117_13/127_13 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 553/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 1459

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E117_13 or E127_13. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:

Criteria
- Feedback received on digital input E117_13 and E127_13 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 554/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.314 CCU Fault Code 1460
E117_09/127_09 Redundancy error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 555/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 1460

Check/Repair wiring between IO module and


CCU.

Code
still triggered in Yes
CCU?

Check/Repair IO module
E117_09 or E127_09. If
necessary replace the
No module.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11 E117 E117
IO station 12 E127 E127

Condition:

Criteria
- Feedback received on digital input E117_09 and E127_09 is valid but have different value for
more than 10 sec.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 556/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.315 CCU Fault Code 1940
Main transformer: all PT100s defective
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1940

Check main transformer


(7) temperature sensors.

End

Components concerned:
Component Device name CCU1 Device name CCU2
Main transformer 7 7

Condition:

Criteria:
- Communication to at least one TCU OK.
- Temperature sensors of main transformer are faulty.

Reaction:
- Fault code triggered
- Traction disabled.

Related messages:
-

3.2.316 CCU Fault Code 1941


Main transformer: Oil circuit 1 overtemperature, VCB off
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 557/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 1941

Check cooling circuit of main


transformer.
Check transformer oil pump.

End

Components concerned:
Component Device name CCU1 Device name CCU2
Main transformer 7 7

Condition:
- TCU1 is ON.

Criteria:
- VCB off because of transformer overtemperature.

Reaction:
- Fault code triggered
- Traction disabled.

Related messages:
-

3.2.317 CCU Fault Code 1942


Main transformer: Oil circuit 2 overtemperature, VCB off
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 558/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 1942

Check cooling circuit of main


transformer.
Check transformer oil pump.

End

Components concerned:
Component Device name CCU1 Device name CCU2
Main transformer 7 7

Condition:
- TCU2 is ON.

Criteria:
- VCB off because of transformer overtemperature.

Reaction:
- Fault code triggered
- Traction disabled.

Related messages:
-

3.2.318 CCU Fault Code 1943


Main transformer: Oil circuit 1 overtemperature, power limitation
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 559/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 1943

Check cooling circuit of main


transformer.
Check transformer oil pump.

End

Components concerned:
Component Device name CCU1 Device name CCU2
Main transformer 7 7

Condition:
- TCU1 is ON.
- TCU1 CB 127.11/1 is ok.

Criteria:
- Power reduction because of transformer overtemperature.

Reaction:
- Fault code triggered

Related messages:
-

3.2.319 CCU Fault Code 1944


Main transformer: Oil circuit 2 overtemperature, power limitation
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 560/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:
Code = 1944

Check cooling circuit of main


transformer.
Check transformer oil pump.

End

Components concerned:
Component Device name CCU1 Device name CCU2
Main Transformer 7 7

Condition:
- TCU2 is ON.
- TCU2 CB 127.11/2 is ok.

Criteria:
- Power reduction because of transformer overtemperature.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 561/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.320 CCU Fault Code 1945
Main transformer: Oil circuit 1 invalid pressure
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1945

Check/repair pressure sensor 213.5/1


and 213.5/2

Message still active? No

Yes

Check/repair pressure sensor amplifier


214/1

Message still active? No

Yes

Check/repair wiring from pressure sensor


213.5/1 and 213.5/1 to pressure sensor
amplifier 214/1 and from 214/1 to TCU1

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU2 415/1 415/1
Transformer temerature sensor 213.5/1, 213.5/2 213.5/1, 213.5/2

Condition:
- CCU must be master

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 562/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- TCU1 is ON.
- TCU1 CB 127.11/1 is ok.
- Oil pump1 not supplied.

Criteria:
- Pressure measured by pressure sensors 213.5/1 and 213.5/2 is either greater than 0.5 bar or
less than 0.4 bar for more than 200 ms.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 563/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.321 CCU Fault Code 1946
Main transformer: Oil circuit 2 invalid pressure
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1946

Check/repair pressure sensor 213.5/3


and 213.5/4

Message still active? No

Yes

Check/repair pressure sensor amplifier


214/2

Message still active? No

Yes

Check/repair wiring from pressure sensor


213.5/3 and 213.5/4 to pressure sensor
amplifier 214/2 and from 214/2 to TCU2

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU2 415/2 415/2
Transformer temerature sensor 213.5/3, 213.5/4 213.5/3, 213.5/4

Condition:
- CCU must be master

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 564/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- TCU2 is ON.
- TCU2 CB 127.11/2 is ok.
- Oil pump1 not supplied.

Criteria:
- Pressure measured by pressure sensors 213.5/3 and 213.5/4 is either greater than 0.5 bar or
less than 0.4 bar for more than 200 ms.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 565/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.322 CCU Fault Code 1947
Main transformer: Oil circuit 1 pressure fault
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1947

Check/repair pressure sensor 213.5/1


and 213.5/2

Message still active? No

Yes

Check/repair pressure sensor amplifier


214/1

Message still active? No

Yes

Check/repair wiring from pressure sensor


213.5/1 and 213.5/1 to pressure sensor
amplifier 214/1 and from 214/1 to TCU1

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU2 415/1 415/1
Transformer temerature sensor 213.5/1, 213.5/2 213.5/1, 213.5/2

Condition:
- CCU must be master

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 566/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- TCU1 is ON.
- TCU1 CB 127.11/1 is ok.
- Oil pump1 supplied.

Criteria:
- Temperature measured by sensors is greater than -10 0C.
- Pressure measured by pressure sensor 213.5/1 and 213.5/2 is either greater than 2.5 bar or less
than 0.75 bar.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 567/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.323 CCU Fault Code 1948
Main transformer: Oil circuit 2 pressure fault
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1948

Check/repair pressure sensor 213.5/3


and 213.5/4

Message still active? No

Yes

Check/repair pressure sensor amplifier


214/2

Message still active? No

Yes

Check/repair wiring from pressure sensor


213.5/3 and 213.5/4 to pressure sensor
amplifier 214/2 and from 214/2 to TCU2

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU2 415/2 415/2
Transformer temerature sensor 213.5/3, 213.5/4 213.5/3, 213.5/4

Condition:
- CCU must be master

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 568/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
- TCU2 is ON.
- TCU2 CB 127.11/2 is ok.
- Oil pump2 supplied.

Criteria:
- Temperature measured by sensors is greater than -10 0C.
- Pressure measured by pressure sensor 213.5/3 and 213.5/4 is either greater than 2.5 bar or less
than 0.75 bar.

Reaction:
- Fault code triggered

Related messages:
-

3.2.324 CCU Fault Code 1949


Main transformer: Oil circuit 1 invalid temperature
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1949

Check main transformer


(210.5/1) temperature
sensors.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU1 and TCU2 415/1, 415/2 415/1, 415/2
Transformer temerature sensor 210.5/1, 210.5/2 210.5/1, 210.5/2

Condition:

- TCU1 is Ok and communication with TCU1 is Ok.

Criteria:
- Difference between oil temperature measured by both sensors is more than 10 degree.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 569/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Reaction:
- Fault code triggered

Related messages:
-

3.2.325 CCU Fault Code 1950


Main transformer: Oil circuit 2 invalid temperature
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 1950

Check main transformer


(210.5/2) temperature
sensors.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCU1 and TCU2 415/1, 415/2 415/1, 415/2
Transformer temerature sensor 210.5/1, 210.5/2 210.5/1, 210.5/2

Condition:

- TCU2 is Ok and communication with TCU2 is Ok.

Criteria:
- Difference between oil temperature measured by both sensors is more than 10 degree.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 570/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.326 CCU Fault Code 2020
WTB Gateway: MVB communication error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 02020

Check MVB plugs of all MVB-devices:


- CCUs / TCUs
- TODs / IOs
- BCU
- MVB-Repeater
Are all plugs connected?
Are all termination plugs connected?
Are all plug internal contacts faultless?
For a rough overview about the MVB-loop, see
architecture document of loco fig 9.

Fault
corrected? No

Check wires of whole MVB loop:


Is a wire interrupted or damaged
somewhere?
Bridge single wires, to see if that
Yes fault is gone.

End

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:

- MVB communication with gateway is not ok.

Criteria:
- Port 605, 607,608,610,621,631 receiving error.

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 571/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 572/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.327 CCU Fault Code 2021
WTB Gateway: Hardware failure
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 02021

Check if fault code 2020


is triggered.

FC triggered?
No

Check TCN Gateway module located in TC 1.


Switch off and On gateway once again.
Yes

Follow instructions of
this additional code.

Fault
corrected? No

Check MVB cable connected


between gateway and devices.
If necessary replace the gateway
Yes module or cables. OR contact
Siemens engineer.

End

Components concerned:
Component Device name CCU1 Device name CCU2
TCN gateway

Condition:
- Cab is active.
- MVB communication with gateway is ok.
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 573/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Criteria:
- Gateway asleep or faulty.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 574/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.328 CCU Fault Code 2022
WTB Gateway: WTB communication error
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 02021

Check if fault code


FC2020 and FC2021 is
triggered.

FC triggered?
No

Check TCN Gateway module located in TC1 from


both master and slave loco. Switch off and On
gateway once again.
Yes

Follow instructions of
this additional code.

Fault
corrected? No

Check WTB cable connected


between gateway
S of master and slave locomotive.
If necessary replace the gateway
Yes module or cables. OR contact
Siemens engineer.

End

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:
- Connection to master loco is lost or connection to slave loco is lost.
- WTB communication not established.
Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 575/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Criteria:
-

Reaction:
- Fault code triggered

Related messages:
- FC2020,FC2021

3.2.329 CCU Fault Code 2050


Remmlot:Transfer error flag triggered
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Components concerned:
Component Device name CCU1 Device name CCU2

Condition:

Criteria:
- Size of HTTP request send buffer is not valid.
- Maximum payload receive buffer/ HTTP reply receive buffer size is not valid.
- TCP/IP send buffer is not logged in or registered.
- TCP/IP receive buffer is not logged in or registered.
- TCP/IP send and receive buffer ID is not same.
- HTTP receive buffer clear failed.
- HTTP request is not successfully generated.
- IP socket is not opened successfully.
- TCP connect error.
- HTTP header not ok.
- HTTP body not ok.
- IP close error

Reaction:
- Fault code triggered

Related messages:
- FC2020,FC2021

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 576/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.330 CCU Fault Code 2100
Fire Detection Equipment (212) is faulty
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 577/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Code = 2100

Check fire detection equipment 212 (23/


10) .

All Ok? No

Repair/replace Fired detection


equipment.
Yes

Check CB 127.9/4. No Fault gone?

Yes

CB Ok? No Replace/Repair CB

Yes

Check IO Modules E222 manually.


Check status LEDs of module. Also No Fault gone?
check cables.

Yes

Replace/Repair wiring
All ok? No
and faulty IO module

Yes

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 578/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
IO station 22 E222 E222
Fire detection equipment 212 212

Condition:

Criteria:
- No feedback signal.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 579/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.331 CCU Fault Code 2101
Fire detection: Smoke detected in locomotive machine room
Applicable variants:
WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 2101

Stop the Locomotive. Physically first


check that the warning is not false and
truly there is smoke or fire in machine
room

Warning false? No

Yes Shut down the locomotive

Acknowledge Fault or reset the alarm.


Check/repair smoke and fire detection
sensors are OK. Check/repair cables.

Fault gone? Yes

No

Check IO Modules E222 and E212


manually. Check status LEDs of every
module. Also check cables.

All ok? Replace/Repair wiring


No
and faulty IO module

Yes

End

Components concerned:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 580/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Component Device name CCU1 Device name CCU2
IO station 22 E222 E222
IO station 21 E212 E212
Fire detection equipment 212 212

Condition:
- Fire detection device is healthy.
- IO module E222, E212 is ok.

Criteria:
- Smoke or fire is detected by one of the sensors and thus smoke warning or fire alarm input is
given to the digital inputs E212_09, E222_12 respectively.

Reaction:
- Fault code triggered
- Start Run interlock is initiated.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 581/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.332 CCU Fault Code 2102
Fire detection: Fire detected in locomotive machine room
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 2102

Stop Locomotive. Physically first check


that is alarm is not false and truly there
is smoke or fire in machine room

Alarm false? No

Yes
Shut down the
locomotive.Inspect the
Acknowledge Fault or reset the alarm.
Machine room and take
Check/repair smoke and fire detection
necessary action. In case of
sensors are OK. Check/repair cables.
fire on loco, use big fire
extinguisher

Fault gone? Yes

No

Check IO Modules E222 and E212


manually. Check status LEDs of every
module. Also check wiring.

All ok? Replace/Repair Wiring or


No
faulty IO module

Yes

End

Components concerned:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 582/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Component Device name CCU1 Device name CCU2
IO station 22 E222 E222
IO station 21 E212 E212
Fire detection equipment 212 212

Condition:
- Fire detection device is healthy.
- IO module E222, E212 is ok.
- CAB1 or CAB2 is active.
- Locomotive is not in trailing mode.

Criteria:
- Smoke or fire is detected by sensors and thus smoke warning or fire alarm input is given to the
digital inputs E212_09, E222_12 respectively.

Reaction:
- Fault code triggered
- Start Run interlock is initiated.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 583/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.333 CCU Fault Code 2103
Multiple IO station failed VCB opened
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 584/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Troubleshooting:

Code = 2103

Check CB 127.9/1,127.9/2,127.9/
3,127.9/4 of each IO station.

CBs ok? No

Replace CB
Yes

Check/repair wiring between CB and IO


station.

Fault gone? Yes

No

Check each IO Module in each IO


station manually. Check status LEDs of
every module.

All ok? Replace/Repair faulty IO


No
module

Yes

Still fault available contact siemens


person.

End

Components concerned:
Component Device name CCU1 Device name CCU2
IO station 11,12,21,22 11,12,21,22
Display 435/1,435/2 435/1,435/2

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 585/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Condition:
-

Criteria:
- Limited drive mode is requested for more than one IO station or any one IO station is completely
faulty and limited drive mode is activated and any other IO station is completely faulty or any
module gets faulty.

Reaction:
- Fault code triggered
- VCB open

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 586/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.334 CCU Fault Code 2104
MEMOTEL: MEMOTEL Device faulty
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 2104

Check CB 127.92

CB ok? No

Yes

Replace CB
Check/repair wiring between CB 127.92 and
Speedometer 94.2. if necessary replace
wiring.

Fault gone? Yes

NO

Check/repair Speed sensors of MEMOTEL


94.1.
Check/repair speedometer 94.2: check
voltage available between Pins 25: 9 or not
and if necessary replace faulty component.
See circuit diagram 10A.

Fault gone? Yes

No

Check /repair wiring between 94.2 and


E211_13.
If IO module is faulty then replace it.

End

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 587/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Components concerned:
Component Device name CCU1 Device name CCU2
IO station 21 E211 E211
CB MEMOTEL Speedometer 127.92 127.92
Speedometer and indicator 94.2 94.2
Pulsegenerator 94.1 94.1

Condition:
-

Criteria:
- MEMOTEL device faulty or there is something wrong with IO module E211.

Reaction:
- Fault code triggered

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 588/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
3.2.335 CCU Fault Code 2105
Fire detection: Fire detected in slave locomotive
Applicable variants:

WAG9 H/P7/P5 WAG9 H 7MW WAP7 Upgrade

Troubleshooting:

Code = 2105

Stop Locomotive. Physically first check


that is alarm is not false and truly there
is smoke or fire in slave locomotive.

Alarm false? No

Yes
Shut down the locomotive .
Acknowledge Fault or reset the alarm.
Inspect the Machine room and
Check/repair smoke and fire detection
take necessary action. In case
sensors (212)are OK. Check/repair
of fire on loco, use fire
cables.
extinguisher

Fault gone? Yes

No

Check wiring between IO Modules A113_04, A113_05, A124_02,


A124_03, A224_02, A224_03, A214_04, A214_05 and Buzzer
238/1,238/2 manually for any damage.

Replace/Repair Wiring or
All ok? No
faulty IO module.

Yes

End

Components concerned:

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 589/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Component Device name CCU1 Device name CCU2
IO station 11 A113 A113
IO station 12 A124 A124
IO station 21 A214 A214
IO station 22 A224 A224

Fire detection equipment 212 in slave loco 212 in slave loco


Buzzer 238 238

Condition:
- CAB1 or CAB2 is active.

Criteria:
- Smoke or fire is detected by sensors and thus fault code is triggered.

Reaction:
- Fault code triggered
- VCB off in slave only.

Related messages:
-

Reference designation: Trouble shooting guide WAG9x Index: Date: Language: Pages:
-TS_RGC07 &EDC023 and WAP7x CCU B 2020-12-03 EN 590/590
Copyright © Siemens AG 2020. All rights reserved. Restricted
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without
express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.

You might also like