HV Bushing (Type C)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

a Nexans company

Catalogue 2011
Nexans Network Solutions
Div. Euromold
COMPANY PRESENTATION

EUROMOLD International standards


Euromold is the leading All our products meet the
European specialised designer, International standards like
manufacturer and distributor CENELEC HD 629.1, CENELEC
of prefabricated cable EN 50180, IEC 60137, IEC
accessories for medium voltage 60502-4… or country speci-
energy distribution. Euromold fications. Official certificates,
provides a complete range of CESI, KEMA, ATEX… prove the
accessories for underground conformity of our products.
cables: premoulded EPDM Long duration tests of existing
rubber connectors for cables or new products are con-
and epoxy bushings for tinuously performed in our test
transformers and switchgear, as fields.
well as a large range of cold-
shrinkable terminations and
joints from 12 to 42 kV. Laboratory accreditation
Euromold is also the Since June 2000, Euromold’s
manufacturer of electrical independent ELAB laboratory
components for the high obtained the BELAC
voltage accessories of the accreditation no.144-TEST
Nexans group. conform with the European
standards for laboratories ISO
17025 for electrical testing of
ISO 9001 Certificate low and medium voltage cable
Since 1992, Euromold’s accessories according to the
commitment to quality is international standards HD 623
demonstrated by its ISO 9001 and HD 629.
certification.

While every care is taken to ensure that the information contained


in this publication is correct, no legal responsibility can be accepted
for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold
reserves the right to alter or modify the characteristics of its products
01/2011

described in this catalogue as standards and technology evolve.

1
SEPARABLE CONNECTORS
AND BUSHINGS
INTERFACE C

Table of contents Interface C


400LB - elbow connector Dimensions according to
430TB - tee connector European CENELEC EN 50180
400TB - tee connector and 50181 (in mm).
434TB - tee connector
440TB - tee connector
300PBM - coupling connector
430TBM-P2/P3 - dual/triple cable arrangement
440PBM - coupling connector
434TBM-P2 - dual cable arrangement
400AR-3 - equipment bushing
400AR-4 - equipment bushing
400AR-5 - equipment bushing
Dia. 56±0.2
400AR-6 - equipment bushing
400SFR-B - equipment bushing Dia. 46±0.2
400A-24B - in-air bushing Dia. 22 min for C1
Dia. 32 nominal for C2
300SA - surge arrester
400PB-XSA - surge arrester M16 x 2 - 6H 0
1.5 -0.5
400TR & 400TR-LB - test rod
400TK-400SW installation tools
Accessories 29
min
Possible arrangements

90±0.2

11
min
01/2011

Dia. 70±0.2

2
Connecting possibilities

BUSHINGS / CONNECTION CONNECTORS /


ACCESSORIES ACCESSORIES

Equipment dead-ending
interface of equipment (K)(M)400DR-B
Dead-end receptacle

(K)(M)400AR-3
Equipment bushing

(K)(M)400AR-4
Equipment bushing
(K)400LB/G
Elbow connector
cable to
(K)(M)400AR-5 equipment
Equipment bushing

(K)(M)400AR-6
Equipment bushing
(K)(M)430TB/G (K)(M)300PBM/G
Tee connector Coupling connector

(K)(M)400SFR-B
Equipment bushing

400A-24B
In-air bushing
(K)(M)434TB/G
Tee connector
cable 300SA
isolation Surge arrester
(K)(M)400SOP-B
Stand-off plug

cable
400GP-B earthing
Earthing plug

tap-off (K)(M)(P)400TB/G (K)(M)440PBM/G


(K)400RTPA 630/250A Tee connector Coupling connector
Reducing tap plug

in-line
junction
(K)(M)400CP-SC
Connecting plug

in-line (K)(M)(P)440TB/G
junction Tee connector
(K)(M)440CP 400PB-XSA
Connecting plug Surge arrester
01/2011

3
400AR-3
INTERFACE C
EQUIPMENT BUSHING

Application Technical characteristics Up to 36 kV - 630 A


For use in equipment insulated Each bushing is tested for
with oil fluid, typically for AC withstand and partial
transformers, switchgear, discharge prior to leaving
capacitors... the factory. 6/10 (12) kV
6.35/11 (12) kV
8.7/15 (17.5) kV
12/20 (24) kV
12.7/22 (24) kV
18/30 (36) kV
19/33 (36) kV

Specifications and
standards
The bolted type equipment
bushings 400AR-3 are moulded
epoxy insulated parts and meet
the requirements of CENELEC
EN 50180 and IEC 60137. 133

Ordering instructions 30
To order the equipment
10
bushing, specify the type.
The bushings can be supplied 330
with an earth jumper (/J).
E.g. M400AR-3/J.
For use in potentially explosive 144
atmospheres (for 12 kV max),
Minimum oil level:
order: 400AR-3/ATEX. -12 kV: 40 mm
Dia.
25
-24 kV: 50 mm
-36 kV: 70 mm

40

M16
Dia. 70
Dia. 88
Dia. 128

In mm.

Equipment Voltage Current


bushing Ur Ir
type (kV) (A)
400AR-3 12 630
01/2011

K400AR-3 24 630
M400AR-3 36 630

22
FIXINGS FOR
EQUIPMENT BUSHINGS

400AR-3/J Bushing Bushing clamping kit


To order the bushing clamping
kit, according to DIN 42 538
standards, simply specify
KBCD-400B.
bushing interface Contents: - 1 x fixing flange B
- 6 x stud clamp E
- 1 x sealing gasket.
fixing studs
WITH BUSHING
fixing flange CLAMPING KIT
B DIN 42 538 & SS304 FIXING
E DIN 42 538 FLANGE
stud clamp

equipment Fixing dimensions


standards DIN 42 538
sealing gasket German standards.

equipment
M10
connection

55
25

6 fixing
Dia. 90
studs
Dia. 140

earth jumper

In mm.

23

You might also like