DESTINATION® GUIDING SHEATHS

Packed 1 per box and includes dilator. All dilators are 0.038” wire compatible.

Inner diameter Fr Item reference Length Hydrophilic coating length Distal curve Valve

GS*F5ST1C45 45 cm 5 cm Straight CCV

GS*F5HS1C45 45 cm 5 cm Hockey stick CCV

5Fr 6FrGS*F5MP1C45 7Fr 45 cm 8Fr 5 cm Multipurpose CCV

GS*F5RDCC45 45 cm 5 cm RDC CCV


5FR 0.076”
(1.92 mm)1
0.087”
GS*F5LIMC45
(2.21 mm) 1 0.101” 45 cm 0.115” 5 cm LIMA CCV
(2.57 mm)1 (2.92 mm)1
GS*K5ST1T90B 90 cm 15 cm Straight TBV

GS*K5MP1T90B 90 cm 15 cm Multipurpose TBV

GS*K5ST1C90B 90 cm 15 cm Straight CCV

GS*K5MP1C90B 90 cm 15 cm Multipurpose CCV

RSR01 45 cm 5 cm Straight CCV

RSR02 45 cm 5 cm Hockey stick CCV

Terumo Interventional Systems is RSR03 45 cm 5 cm Multipurpose CCV

committed to your success with


5Fr 6Fr 7Fr 8Fr
RSR13 45 cm 5 cm RDC CCV

innovative procedural solutions 0.076”


(1.92 mm)1 6FR 0.087”
(2.21 mm)1
0.101”
RSR14
0.115”
45 cm 5 cm LIMA CCV

and ongoing support for your most


(2.57 mm)RSC01
1
(2.92 mm)1 90 cm 15 cm Straight TBV

challenging cases.
RSC03 90 cm 15 cm Multipurpose TBV

RSC05 90 cm 15 cm Straight CCV

PUSHING BOUNDARIES
RSC07 90 cm 15 cm Multipurpose CCV

RSP01 65 cm 35 cm Straight CCV

GUIDING YOUR
RSR04 45 cm 5 cm Straight CCV

RSR05 45 cm 5 cm Hockey stick CCV

RSR06 45 cm 5 cm Multipurpose CCV


5Fr 6Fr 7Fr 8Fr

PROCEDURES
RSR15 45 cm 5 cm RDC CCV

We are relentlessly seeking new ways 0.076” 0.087” RSR16 45 cm 5 cm LIMA CCV
(1.92 mm)1
7FR 0.101” 0.115”
to help you apply effective solutions
(2.21 mm)1
(2.57 mm)1 (2.92 mm)1
RSP02 65 cm 35 cm Straight CCV

and achieve better outcomes for

THROUGH
RSC02 90 cm 15 cm Straight TBV

more patients. RSC04 90 cm 15 cm Multipurpose TBV

RSC06 90 cm 15 cm Straight CCV

CONSISTENT
RSC08 90 cm 15 cm Multipurpose CCV
5Fr 6Fr 7Fr 8Fr
54-84501 45 cm 35 cm Straight CCV
0.076” 0.087” 54-86501 65 cm 35 cm Straight CCV
8FR
(1.92 mm)1 0.101” 0.115”
(2.21 mm)1

RELIABILITY
(2.57 mm)1 (2.92 mm)1
54-89001 90 cm 60 cm Straight CCV

54-89006 90 cm 60 cm Straight TBV

RDC: Renal Double Curve - LIMA: Left Internal Mammary Artery - CCV: Cross Cut Valve - TBV: Tuohy-Borst Valve
1.Data on file. Terumo Medical Corporation

Terumo Corporation Terumo Europe NV Terumo Deutschland GmbH Terumo Middle East FZE
+81333748111 BeNeLux Sales Division Switzerland +971 4 292 0200
Belgium: +41 56 419 10 10
Terumo Europe NV 0800 14468 Terumo UK Ltd
The Netherlands: Terumo Europe España SL +44 1276 480 440
+3216381211 +34 902 10 12 98
0800 0231938
Terumo BCT Tıbbi Cihazlar Dağıtım
TerumoFrance S.A.S.
Terumo Terumo Europe NV ve Hizmetleri A.Ş.
+33 130 96 13 00
Interventional Systems EMEA Emerging Market Division +90 216 645 92 00

IS726GB1217ITI(0118)E
+331471609 30 +3216 38 12 11 TerumoItalia S.r.l.
Terumo Deutschland GmbH +39 06 94 80 28 00
EMEA Sales Offices
+49 6196 80 230 TerumoRussia LLC
Terumo Deutschland GmbH +7 495 988 4740
TerumoEurope NV
Africa Business Division Österreich Terumo Sweden AB ® Registered Trademark
www.terumo-europe.com +32 16 38 13 08 +43 2236 378020 +46 3174 85 880 Published by Terumo Europe NV

www.terumo-europe.com
ALLOWS SMOOTH SHAPES AND SIZES TO MEET YOUR PERIPHERAL CHALLENGES
TRANSITION AND EASY Maintains shape and positioning

PENETRATION • Outstanding durability, even in the longest


procedures
Enhances visualization for precise positioning
• Triple radiopacity (sheath, dilator, Detachable valve options
Atraumatic tip
and gold coil marker)
• Minimizes potential for vessel damage
Resists kinking
Smooth transitions
• Stainless steel coil for consistent reliability
• Guidewire-to-dilator and dilator-to-sheath
Provides smooth movement
Provides lesion access
• Coil reinforced tubing and a PTFE inner
• Exceptional trackability, even in the most challenging anatomy
layer that minimizes friction

Gold Coil PTFE Inner Nylon Outer Nylon outer layer reinforced
Marker Layer Layer with stainless steel coil
Cross Cut haemostatic valve (CCV)
TM

Hydrophilic coating Accommodates anatomical


Hydrophilic at distal end variations in vessel access
Stainless Steel Coating • Straight
Coil • Hockey Stick
• Multi-Purpose
Tuohy-Borst valve (TBV) • Renal Double Curve (RDC)
• Left Internal Mammary Artery (LIMA)
Atraumatic tip

Designed to work with


and
Support Catheter Peripheral Guidewires

Data on file. Data on file. Data on file.

You might also like