Procter & Gamble Co.

DESIGN AND CONSTRUCTION SPECIFICATION


Engineering Practice AC-BASE ZEOLITE TYPE A Revised:
------:------ Dry Material Data Sheet
Non- Discretionary 12/01/01
For P&G Use Only ACBM
P&G HAZARD CLASS
3 Page: 1 of 3
FABRIC & HOME CARE Product Category: Dry Laundry N.A.: X
Global:

CHEMICAL IDENTIFICATION

Chemical Abstract CAS#:


Stock Code: 53950
Code Name: AC-BASE (Zeolite type A)
Common Name(s): AC-BASE (Zeolite type A)
Chemical Name: Sodium Alumino Silicate
Chemical Formula: Na2 O:Al 2 O3 :2SiO2 :3.94H2 O

PHYSICAL PROPERTIES

Storage Temperature: Normal: Ambient Maximum: 120°F


Use Temperature: Oper: Ambient Maximum: 120°F
Critical Temperature: Not available at time of publication
Flash Point Closed Cup: Not available at time of publication
pH: 10.1-11.4 @ 70°F or 1% solution
Specific Gravity: Not available at time of publication
Specific Heat: btu/lb. ° F Not available at time of publication
Heat of fusion: Not available at time of publication
Bulk Density:
Storage: (Compacted) 28lb. /cu ft
Transfer: (Loose) 18lb. /cu ft
Molecular Weight: 355
Hygroscopicity: Low
Solubility in Water: Insoluble
Abrasiveness: None
Allowable Moisture Content: Min: 18%, Max: 22%
Purity: 99.5%
Particle Size: On100=0%, on 325 & courser=0.5%
Flowability: Average free flowing
Angles of Repose: 42-deg slide 45-deg repose
Physical State: Crystalline powder
Color: White
Concentration: Alumino Silicate 76-78%

HEALTH / SAFETY / ENVIRONMENTAL

NFPA / P&G Hazard Rating: FLAMMABILITY

0
1 0

HEALTH REACTIVITY
P&G Hazard Class per HSE CBA GGC105: 3
Health Concerns: Dust Exposure cause only slight irritation to the eyes, skin or respiratory
passages.
ACGIH-TLV: None
OSHA-PEL: None
HSDS: 1015
Exposure Standards: mg/cu m: 1mg/CU m as total detergent dust
Safety Shower / Eyewash Station per HSE DP GID090: Not Required
Procter & Gamble Co. DESIGN AND CONSTRUCTION SPECIFICATION
Engineering Practice AC-BASE ZEOLITE TYPE A Revised:
------:------ Dry Material Data Sheet
Non- Discretionary 12/01/01
For P&G Use Only ACBM
P&G HAZARD CLASS
3 Page: 2 of 3
FABRIC & HOME CARE Product Category: Dry Laundry N.A.: X
Global:

HEALTH / SAFETY / ENVIRONMENTAL(Continued)

MSDS: Not available at time of publication


Personal Protective Equip: Approved dust masks should be available for prolonged exposure to high
dust levels
Environmental Concerns: Installation using this material may require an environmental permit.
Air: Appropriate emission control is required.
Water: Spilled material in unloading, storage and process areas should not be
permitted to reach waterways via rainfall, run-off or hosing to storm
sewers. Locations with frequent spills should have yard or building drains
connected to municipal sewers with curbs or grading designed to
minimize rainfall run-off and encourage dry clean-up
Process Safety Hazard/Concern: No process safety hazards concerns
Electrical Classification: Not available at time of publication
Conductivity: 0.01MHOS/m
Dust Control: Material excessively dusty required to meet good manufacturing
standards.
Dust Explosion Data:
Maximum Explosion Pressure: ----- psi
Maximum Rate of Pressure Rise: ----- psi/sec
Explosion Severity: ------
Minimum Ignition Energy of Dust Cloud: ------ btu
Minimum Ignition Temperature: ------ ° F
Minimum Explosive Dust Concentration: ------ oz /cu ft
Comments: Applies to CMC with a pH of 8.0-9.0 only.

WELDING, EXAMINATION & INSPECTION

• Refer to P&G Welding CBA WE01"General Welding System Requirements", Section 5 for complete information.

• Vendor and Contractor Welders shall use their company welding practices for all welding of piping system. These procedures
should be approved by a P&G Welding Engineer prior to use.

• P&G welders are to use P&G welding procedures. These can be found in the P&G Welding Manual located on Alliance Net.

• Refer to P&G Welding CBA WE01 "General Welding System Requirements", Section 6 and P&G Welding CBA WE05
"Specification for Purchase of Fabricated Equipment, Structures and Components" for complete information.

• Examine a sufficient number of welds to ensure conformance to local codes, such as ANSI B31.1 and B31.3, as well as the
applicable Piping Construction Specifications (PCS).

• The quality of completed welds shall meet the minimum requirements of the applicable code and shall present a good visual
appearance. Welds must be smooth, uniform, without excessive reinforcement, undercut, porosity, or root concavity. All slag,
spatter, etc., Must be removed from the completed welds.

• Many codes require exams in addition to visual, such as spot or random radiography.

• Witness pressure testing of piping. Pressure testing shall include the examination of all joints (with insulation off) for leakage,
as well as examination of the pressure gage/chart.

• All mandatory exams and tests must be performed and documented.


Procter & Gamble Co. DESIGN AND CONSTRUCTION SPECIFICATION
Engineering Practice AC-BASE ZEOLITE TYPE A Revised:
------:------ Dry Material Data Sheet
Non- Discretionary 12/01/01
For P&G Use Only ACBM
P&G HAZARD CLASS
3 Page: 3 of 3
FABRIC & HOME CARE Product Category: Dry Laundry N.A.: X
Global:

SYSTEM CONSIDERATIONS

Overheating: Under 200°F no concern


Overcooling: No concern
Corrosion Problems: Use rust preventative and phosphate slurry coating on all internal surfaces
Reference: Not available at the time of publication
Startup Cleaning: Dry
Receipt: Railcar and Truck
Transfer:
Unloading: Positive displacement system
Reclaim: Mechanical and/or positive displacement system.
Air Conveying: Positive displacement or vacuum system
Storage: Can pick up odors, easily aerates and bridges
Particle Break Up: Critical to uniform density control
Flooding Tend to flood screw feeders when aerated
Bridging: Static build-up tends to cause cohesive arches and compaction
Caking: See bridging
Segregation: No concern

EQUIPMENT GUIDELINES

Materials of Construction: Carbon Steel


Feeder: Oversize (material aerates)
Chute Angle: 70-deg min.
Bin: 70-deg min.
Silo: Material bridges use aerators on hopper walls
Screw Conveyor: Slow RPM range and oversize to control flow
Bucket Elevator: Continuous discharge type
Quantity/Storage Limitations: Not available at the time of publication
Layout /Clearance Limitations: Not available at the time of publication

You might also like