Professional Documents
Culture Documents
.1st Batch of P&IDs Consolidated For MCPP
.1st Batch of P&IDs Consolidated For MCPP
CURRENT-PRESSURE
INSTRUMENT LETTERS
SWITCH HIGH-HIGH
SWITCH HIGH-LOW
PRIMARY ELEMENT
ALARM HIGH-HIGH
SWITCH LOW-LOW
ALARM HIGH/LOW
ALARM LOW-LOW
SAFETY ELEMENT
FUNCTION
TRANSDUCER
(RUPTURE DISK)
SWITCH CLOSED
####
THERMOWELL
TRANSMITTER
TRANSMITTER
SWITCH OPEN
GAUGE GLASS
SHOWN IN P&ID
DIFFERENTIAL
SWITCH HIGH
(TOTALIZER)
SWITCH LOW
CONTROLLER
CONTROLLER
ALARM HIGH
ALARM LOW
INDICATOR
####
RECORDER
TEMPERATURE INSTRUMENTS
TEST POINT
INDICATOR
SAFETY
RECORDER
LOOP
SWITCH
ALARM
FIRST LETTER
VALVE
NUMBER
WITH OPTIONAL
MODIFIER (NOTE-4,5,6)
A ANALYSIS AAH AAHH AAHL AAL AALL AE AI AIC ASH ASHH ASHL ASL ASLL AT
B BURNER,COMBUSTION
C USER'S CHOICE
D DENSITY DA DAH DAHH DAHL DAL DALL DE DI DSH DSHH DSL DSLL DT
TG
E VOLTAGE EA EAH EAHH EAHL EAL EALL EE EI EIC ESH ESHH ESL ESLL ET TG TW
F FLOW RATE FA FAH FAHH FAHL FAL FALL FE FG FI FIC FQ FR FRC FS FSH FSHH FSHL FSL FSLL FT FV FY
INST.
FF FLOW RATIO FFAH FFAHH FFAHL FFAL FFALL FFE FFI FFIC FFR FFSH FFSHH FFSHL FFSL FFSLL FFT FFV FFY PIPING
FQ FLOW TOTAL FQAH FQAHH FQAHL FQAL FQALL FQE FQI FQIC FQR FQSH FQSHH FQSHL FQSL FQSLL FQT FQV FQY
G USER CHOICE
H HAND (MANUAL) HIC HS HV HY
I CURRENT IA IAH IAHH IAHL IAL IALL IE II ISH ISHH ISHL ISL ISLL IT
J POWER JA JAH JAHH JAHL JAL JALL JE JI JSH JSHH JSHL JSL JSLL JT
L LEVEL LA LAH LAHH LAHL LAL LALL LE LG LI LIC LR LRC LS LSH LSHH LSHL LSL LSLL LT LV LY
N USER CHOICE
O USER CHOICE
P PRESSURE PA PAH PAHH PAHL PAL PALL PD PE PG PI PIC PR PRC PS PSE PSH PSHH PSHL PSL PSLL PT PV PY PZT
TIT
Q QUANTITY QA QAH QAHH QAHL QAL QALL QE QI QIC QSH QSHH QSHL QSL QSLL QT
R RADIATION RA RAH RAHH RAHL RAL RALL RE RI RIC RSH RSHH RSHL RSL RSLL RT
S SPEED SA SAH SAHH SAHL SAL SALL SE SI SIC SSH SSHH SSHL SSL SSLL ST
TIT
T TEMPERATURE TA TAH TAHH TAHL TAL TALL TE TG TI TIC TP TR TRC TS TSH TSHH TSHL TSL TSLL TT TV TW TY TE
TW
U MULTIVARIABLE UV UY
VIBRATION / INST.
V MECHANICAL VA VAH VAHH VAHL VAL VALL VE VI VR VS VSH VSHH VSHL VSL VSLL VT PIPING
ANALYSIS
W WEIGHT, FORCE
X ON/OFF, ACTUATED XS XV XY
Y EVENT, STATE YA YSH YSHH YSHL YSL YSLL
Z DIMENSION POSITION ZA ZAH ZAHH ZAHL ZAL ZALL ZE ZI ZIC ZR ZRC ZS ZSC ZSH ZSHH ZSHL ZSL ZSLL ZSO ZT ZV ZY
TYPE OF FLOW INSTRUMENTS FOR NON SOUR SERVICE TYPE OF FLOW INSTRUMENTS FOR SOUR SERVICE DRAIN AND VENT DETAILS
SHOWN IN P&ID ACTUAL DETAILS OF TYPE OF FLOW INSTRUMENTS SHOWN IN P&ID ACTUAL DETAILS OF TYPE OF FLOW INSTRUMENTS FOR SOUR SERVICE DRAIN FOR NON SOUR SERVICE DRAIN
R R
FE FIT FE
N DO FE FIT FE
N DO
VE ING VE ING
PIP . PIP .
T T
INS INS
" EQUIPMENT EQUIPMENT
1/2 1"
1/2" 1"
FIT FIT
TYPE 1A TYPE 1A
FOR GAS AND NON-SOUR SERVICE FOR GAS AND NON-SOUR SERVICE TYPE 1B TYPE 1B
FOR GAS AND SOUR SERVICE FOR GAS AND SOUR SERVICE
FIT FIT
FE FIT FE FIT
DC DO
INS
1/2"
INS
T. 1" 1" T.
1/2 PIP
" PI ING
PIN
VEN G VEN
DO DO
R R
FE FE
OR DO
R
FE FIT E ND FE FIT
VE
N
V
ING ING
PIP . PIP .
T T
INS INS
1/2
1"
1/2"
1"
"
1/2"
1/2
1"
1"
"
FIT FIT
FIT FIT ATMOSPHERE
FLARE ATMOSPHERE
VENT HEADER
FIT FIT
FIT FIT
1"
1"
INS INS
1/2"
T. T.
"
1/2
1"
1"
PIP PIP
FIT FIT
"
ING ING
VE
ND VE
OR ND
OR
FE FE
TYPE OF PRESSURE INSTRUMENTS TYPE OF LEVEL INSTRUMENTS TYPE OF LEVEL INSTRUMENTS
SHOWN IN P&ID SHOWN IN P&ID ACTUAL DETAILS OF TYPE OF LEVEL INSTRUMENTS SHOWN IN P&ID ACTUAL DETAILS OF TYPE OF LEVEL INSTRUMENTS
LIT LIT
2"
PIT/PG
NON-CONTACT RADAR NON-CONTACT RADAR
2"
PIT/PG LG
4" 4"
LG
MLI
INST. NOTE 2
PIPING MLI
2" (EQUIPMENT) / 3/4" (PIPING)
INST. 2"
2"
PIPING
NOTE 3
TYPE 1 TYPE 1
2" 2"
LG
LG
INST.
NOTE 2
PIPING MLI
MLI
FSH FSH
2" (EQUIPMENT) 2" (EQUIPMENT)
3/4" (PIPING) 3/4" (PIPING)
2"
2" INST.
PIPING
TYPE 3 TYPE 3
(NON SOUR SERVICE) (NON SOUR SERVICE)
INST. PIPING
LIT
LIT 3"
3"
D/P
TYPE OF SHUTDOWN VALVE / ON-OFF VALVE TYPE OF SHUTDOWN VALVE / ON-OFF VALVE TYPE OF MOTOR CONTROL NOTE 5
TYPE 6 TYPE 6
SHOWN IN P&ID ACTUAL DETAILS OF TYPE OF SDV/ON-OFF VALVE SHOWN IN P&ID ACTUAL DETAILS OF TYPE OF MOTOR CONTROL
ZDA
NOTE 1, 4
XHC
TYPE 1 TYPE 1 TYPE 1 TYPE 1- CONTINUOUS OPERATION (WITH AUTO START) DUTY/STANDBY
SELECTOR
HS
XY
ZDA NOTE 1, 4, 9,10 S ZIO ZIC *
UZV UZV
MCC
TYPE 7 TYPE 7 MOTOR A MOTOR B
XHC
TYPE 2 TYPE 2 - INTERMITTENT OPERATION (WITH AUTO START)
XY
SHUT DOWN VALVE (WITHOUT PST) A NOTE 1, 4 HS
S ZDA
* DUTY/STANDBY
IA STOP START TRIP
SELECTOR
TRIP STOP START
IA HS HS XZ XZ HS HS
NOTE 2 ZIO ZIC ZIP ON-OFF VALVE (DOUBLE ACTING CYLINDER IN PACKAGE UCP) MCC
UZV S
MOTOR A MOTOR B
IA
MCC
TYPE 3 (NOTE 8) TYPE 3
(NOTE 8) TYPE 4 TYPE 4
ANTI-SURGE VALVE WITH ELECTROPNEUMATIC POSITIONER, START/EMERGENCY STOP/HOA SWITCH
STOP
XHC SOLENOID, POSITION TRANSMITTER, POSITION SWITCH (HAND-OFF-AUTO)
(BY ELECTRICAL)
XY HS HS HS
A NOTE 1, 4 *A1/B1
S ZDA LOCAL/
REMOTE
RUNNING SELECTION
IA IA
BLOWDOWN VALVE FAULT STOPPED STATUS
* DUTY/STANDBY
BDV IA STOP START
SELECTOR
STOP START
ON-OFF VALVE (DOUBLE ACTING CYLINDER)
ZSO ZSC HS HS HS HS
NOTE 2 BDV *A1 *A2 *B1 *B2
I HS LOCAL/ LOCAL/
REMOTE REMOTE
SELECTION RUNNING/ RUNNING/ SELECTION
TYPE 4 TYPE 4 STATUS STOPPED FAULT FAULT STOPPED STATUS
START/EMERGENCY START/EMERGENCY
XIRL XI XIFA STOP/HOA SWITCH STOP/HOA SWITCH XIFA XI XIRL
HS (HAND-OFF-AUTO) (HAND-OFF-AUTO) HS
MCC
TYPE 5 TYPE 5
ZDA
NOTE 1, 4
I
UZY
IA I S ZIO ZIC
UZV IA
ZSO ZSC
NOTE 2 UZV