Lighting

Essential LEDtube
LEDtube 1200mm 16W 765 T8 AP I G
Essential LEDtube is an affordable LED tube that is suitable for replacing T8
fluorescent lamps. The product provides a natural lighting effect for use in general
lighting applications, as well as instant energy savings – an environmentally friendly
solution.

Product data

General Information Voltage (Nom) 220-240 V

Cap-Base G13 [ Medium Bi-Pin Fluorescent]

Main Application Industrial Temperature


Nominal Lifetime (Nom) 15000 h T-Ambient (Max) 45 °C

Switching Cycle 50000X T-Ambient (Min) -20 °C

B50L70 15000 h T-Storage (Max) 65 °C

T-Storage (Min) -40 °C

Light Technical T-Case Maximum (Nom) 60 °C

Color Code 765 [ CCT of 6500K]

Luminous Flux (Nom) 1600 lm Controls and Dimming


Luminous Flux (Rated) (Nom) 1600 lm Dimmable No

Correlated Color Temperature (Nom) 6500 K

Color Consistency <7 Mechanical and Housing


Color Rendering Index (Nom) 73 Product Length 1200 mm

LLMF At End Of Nominal Lifetime (Nom) 70 %

Approval and Application


Operating and Electrical Energy Efficiency Label (EEL) A+

Input Frequency 50 to 60 Hz Energy Saving Product Yes

Power (Rated) (Nom) 16 W Suitable For Accent Lighting No

Lamp Current (Nom) 130 mA Approval Marks RoHS compliance KEMA Keur certificate

Starting Time (Nom) 0.5 s Energy Consumption kWh/1000 h 16 kWh

Warm Up Time to 60% Light (Nom) 0.5 s

Power Factor (Nom) 0.5

Datasheet, 2019, July 12 data subject to change


Essential LEDtube

Product Data Numerator - Packs per outer box 20

Full product code 871869659998300 Material Nr. (12NC) 929001184638

Order product name LEDtube 1200mm 16W 765 T8 AP I G Net Weight (Piece) 0.222 kg

EAN/UPC - Product 8718696599983

Order code 929001184638

Numerator - Quantity Per Pack 1

Dimensional drawing

A3 Product D1 D2 A1 A2 A3 C D

LEDtube 1200mm 25.68 28 mm 1198 1205 1212 1212 27.8

A2 16W 765 T8 AP I G mm mm mm mm mm mm

A1
D1
D2

TLED 1200mm 4ft T8 16W-36W 6500K G13 ND

Photometric data

General Uniform Lighting


1 x TLED 16W 6500K 240D 9290011275

1 x 1600 lm

Polaro intensityo diagramo Quantity estimation diagram UGR diagram


150 180 150 nr. of luminaires
16.0
200 hroom: 2.8 m hroom: 2.8 m
Reflectances: 0.70, 0.50, 0.20 22 Refl: 0.70 0.50 0.20
150 Maintenance factor: 1.0 m
60 25
Ceiling mounted
120o 120o Ceiling mounted
100
12.0 : viewed endwise
750 lx
50 45 Y : viewed crosswise

90o 90o Y : Parallel to viewing dir.


500 lx
50 30
8.0
19
60o 100 60o 300 lx 22
15
150
γ
200 4.0
0
(cd/1000lm) 0o 10 30 50 70 90 (m2) 4.0 8.0 12.0 m 16.0
X
0-180o 90-270o
Utilisation factor table Luminance Table
Light output ratio 1.00
Service upward 0.27 Reflectances (%) for ceiling, walls and working plane (CIE) Plane 0.0 15.0 30.0 45.0 60.0 75.0 90.0
Room Cone
Service downward 0.73 0.80 0.80 0.70 0.70 0.70 0.70 0.50 0.50 0.30 0.30 0.00
45.0 5495 5468 5447 5497 5709 6300 7671
Index 0.50 0.50 0.50 0.50 0.50 0.30 0.30 0.10 0.30 0.10 0.00
50.0 5311 5269 5221 5228 5376 5902 7379
CIE flux code 36 64 85 73 100 k 0.30 0.10 0.30 0.20 0.10 0.10 0.10 0.10 0.10 0.10 0.00
55.0 5150 5100 5022 4979 5040 5471 7030
60.0 5020 4962 4863 4765 4725 5031 6648
UGRcen (4Hx8H, 0.25H) 23 0.60 0.40 0.38 0.38 0.37 0.36 0.29 0.27 0.22 0.25 0.21 0.17
0.80 0.50 0.47 0.47 0.46 0.44 0.37 0.34 0.29 0.31 0.27 0.22 65.0 4911 4859 4728 4578 4434 4555 6150
1.00 0.58 0.53 0.54 0.53 0.51 0.43 0.40 0.35 0.36 0.32 0.27 70.0 4839 4789 4637 4441 4198 4074 5569
1.25 0.65 0.60 0.62 0.59 0.57 0.50 0.46 0.41 0.42 0.38 0.31 75.0 4821 4766 4602 4378 4019 3590 4802
1.50 0.72 0.65 0.67 0.65 0.62 0.55 0.50 0.45 0.46 0.42 0.35 80.0 4838 4777 4625 4362 3914 3130 3678
2.00 0.81 0.72 0.76 0.72 0.69 0.63 0.57 0.53 0.52 0.49 0.41
85.0 4876 4794 4658 4416 3899 2819 2103
2.50 0.87 0.77 0.82 0.78 0.74 0.68 0.62 0.58 0.57 0.54 0.46
3.00 0.92 0.81 0.86 0.81 0.77 0.72 0.66 0.62 0.60 0.57 0.49 90.0 4958 4875 4734 4500 4022 2845 1531
2
4.00 0.98 0.85 0.92 0.86 0.81 0.77 0.71 0.67 0.65 0.62 0.53 (cd/m )
5.00 1.02 0.88 0.96 0.90 0.84 0.80 0.74 0.71 0.68 0.65 0.56

Ceiling mounted
2015-04-17

CalcuLuX Photometrics 4.5 Philips Lighting B.V. Page: 1/1

LEDtube 1200mm 16W 765 T8 CN I G

100
Intensity (%)

80

60

40

20

0
200 300 400 500 600 700 800
[nm]

Datasheet, 2019, July 12 2 data subject to change


Essential LEDtube

Lifetime

100 80

Failure rate in %
Failure rate in %

70
80 60 60
60 50
40 70
40 30
80
20
20
10
0 0
0 5000 10000 15000 20000
0 5000 10000 15000 20000 25000 30000
Time (hours)
Time (hours)

LEDtube 16W G13 740 T8 AP I G LEDtube 16W G13 740 T8 AP I G

20000 100
95

Lumen (%)
15000
Life time (Hours)

90
B10L70
10000 85

B50L70 80
5000
75
0 70
50 55 60 65 70 75 80 0 5000 10000 15000 20000
Tc(°C) Burning hours

LEDtube 16W G13 740 T8 AP I G LEDtube 16W G13 740 T8 AP I G

100%

98%
Lumen (%)

96%

94%

92%
55 60 65 70 75
Tc(°C)

LEDtube 16W G13 740 T8 AP I G

Datasheet, 2019, July 12 3 data subject to change


Essential LEDtube

© 2019 Signify Holding All rights reserved. Signify does not give any representation or warranty as to the accuracy or

completeness of the information included herein and shall not be liable for any action in reliance thereon. The

information presented in this document is not intended as any commercial offer and does not form part of any

quotation or contract, unless otherwise agreed by Signify. Philips and the Philips Shield Emblem are registered www.lighting.philips.com

trademarks of Koninklijke Philips N.V. 2019, July 12 - data subject to change

You might also like