Professional Documents
Culture Documents
Adobe Scan Nov. 17, 2022
Adobe Scan Nov. 17, 2022
A/
3. Instai! adapters G1 and G2, and then instai!
* Testing tools nipple [1] and hose [2] of hydraulic tester G3 ar
Sym- Partname connect them to gauge [4].
Pari No.
boi
1 799-401-3100 Adapte,
Adapter G1:
2 799-401-3200 Adaptar
15 :1: 1.0 Nm {1.53 :1: 0.10 kgm}
799-101-5160 ..
799-101-5002 Hydraulic tester
Nipple
Adapter G2:
25 :1: 1.5 Nm {2.55 :1: 0.15 kgm}
G
3 799-101-5150
790-261-1150
799-101-5140
Hose
Hose
Gauge
.
. * Use gauge [4] of 2.5 MPa (25 kg/cm2}.
* The nipple and hose of digital hydraulic test,
4 790-261-1204 Digital hydraulic tester G4 can also be used .
Testing 1Pe200_1/M9Kt-362-K.(J().A/
4. Start lhe engine and measure lhe oil pressures
1. Open lhe engine hood and remove step (1)
atlowidle.
* When EGR valve and KVGT driving oil
pressure are within lhe following standard
range, they are normal.
Drive oil pressure of Min. 1.2 MPa
EGR valve and KVGT Min. (12.0 kg/cm2)
KVGT contrai oil 0.3 to 1.0 MPa
pressure (3.1 to 10.2 kg/cm2)
141
2. Disconnect hoses (2) and (3).
• Hose (2): Hydraulic circuit for EGR valve and
KVGTdrive
• Hose (3): KVGT contrai pressure circuit
B4P24378