Part.

PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 1/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3. PCB application
3.1. PCB classification
a. Classification by name

A B C D E F

Type Location Function Speed Seg. Work. seg.


Working Segment

When works are


segmented within a PCB,
mark with 0~9.

PCB Segment

When the PCBs of


the same function
has various forms
PCB speed segment and are not classified
in A, B, C and D,
1 : 60 ~ 105m/min mark with 0~9, A,
B… sequentially
When the PCB is used
commonly regardless of
speed, use the type name
developed and applied first.

PCB function segment


C : Control
P : Power (Power supply)
A : Annunciator
S : Supervisory panel
L : LON

PCB location R : I/O(Input/Output)

P : Power electronics D : Door

O : Operation G : G/A (Gate Array)

H : Hall I : Indicator

C : Car V :Voice(Voice synthesizer)

D : Door F : Flickering
Distributed control M : Dot Matrices
S : Monitoring panel
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 2/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

b. PCB application standard


Speed
Segment Usage Si210 60~105 m/min

Main CPU PCB for


DOC – 131 (Standard)
operations
DSP PCB speed control DPC – 122 (Standard)

GDC PCB DPP – 150 (L-IPM 50,75A), 140(L-IPM 100,150A)


DPP – 111 (IGBT 200A)

Power rectifying section DOP –116

Brake Control DPB-110

Control DOM – 110A (Fire, Generator)


Panel MIC PCB DOM – 110B (Fire, Generator, Emergency)
DOM – 111A (Domestic)

DOR – 100 (Emergency of Domestic)


DOR – 101 (For supervisory)
Relay PCB
DOR – 110A (Fire, Emergency)
DOR – 120 (Generator)
DOR – 131 (Standard)

Panel for local


DOS –100
Supervisory

Car LON PCB DCL – 243


Car
CPI PCB DCM –12X.

Hall PCB DHG – 162

Hall Vertical type PCB DCM – 10X,

Horizontal type PCB DCM – 11X,

DCD – 231,(ADS Door)


Door INV. DOOR PCB
DCD – 232,(SED Door)
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 3/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.2. DOC-131 PCB


3.2.1. Layout of DOC-131 PCB
a. Picture of DOC-131 PCB
SVC tool
Connector
SD: DEBUG

ST: HPC I/F

SH: Hall SVC tool


Communication Power SW
SW2 SW3
Car Commu
SM: CRT JP1 Terminal
Communication SH Resistor
SM
SL SC: Car Comm
-unication

SL: Duplex
Communication

CB: Car Safety


SW
(Fire operation) SPEC1 SPEC2
Left Right

CA: Car Door DIR


SW
(OPB SW, SES)
TMR1
HA: Hall, Pit SW

AC: Additional
Out put Normal
Maint
To VA
connector of
AA: In put DPC PCB
(Fire, Abnormal
Air condition)

+5 V
+15 V
AA: Out put GND
(Fire,
Air condition) GND
G48

AF: SW connection CT: CTT connection


In control panel In control panel
RE
Fuse Resistor Rotary Encoder
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 4/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.2.2. Function of DOC-131 PCB


a. Details
a) DIR (red): Indicates rotary encoder direction setting. If there is any error on the
direction setting, LED will light up. If normal, LED will remain off.
b) ALM (red): Indicates alarms. If there is one error among the following 5 conditions,
relative LED will light up.
No. Conditions Error detection method

1 Safety relay error R5SC Relay remains OFF


2 DOC PCB Watchdog error SYS1 LED remains ON or OFF
3 DPC PCB Watchdog error SYS2 LED remains ON or OFF
4 P48V error PF LED remains ON (Lights up)
5 LON communication error SER LED remains ON
c) SYS1 : Flickers when DOC Watchdog is normal. If abnormal, remains ON or OFF.
d) SYS2 : Flickers when DPC Watchdog is normal. If abnormal, remains ON or OFF.
e) PF : Remains OFF when P48 is normal. If abnormal, remains ON.
f) LON : LED for checking LON communication. If the communication with CAR LON is
normal, it will flicker. If abnormal, remains ON or OFF.
g) TD1 : G/A Com. checking LED. Flickers during communication and remains OFF
other times.
h) TD2 : G/A Com. checking LED. Flickers during communication and remains ON
other times.
i) TD3 : G/A Com checking LED. Flickers during communication and remains OFF
other times.
j) CDS: Car door switch checking LED. When door is closed, it will be turned on.
(Open: OFF)
k) R5SC: Safety checking LED. If normal, remains ON
l) R2LD : Hall door checking LED, it will be turned on when all of hall door are closed
m) RDZ: Door open Zone checking LED. If car is at Door Zone it will be turned off.
But it is at out of door zone, it will be turned on
n) R1ML, R7LF, R7FN: CTT work checking LED. When related CTT works, they will be
turned on
o) Fuse Resistor: In case that electric noise flows through P48V line to DOC-131, the
resistor protects DOC-131 from damage as a fuse function
Replace the resistor in case of TCD84, 85, & 95 and failure of resistor*

[How to replace resistor]


Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 5/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

Push button
for releasing

1) Switch off main switch before starting work.


2) Remove the resistor (3) with pressing push button
3) Prepare fuse resistor that is placed in spare fuses packing
4) Assemble new fuse resistor with pressing push button.
(2 fuse type resistors are packed for spare)

※ Caution
Green LED will flicker and red remains OFF in normal conditions.
Yet, TD1, 2, 3 LED flicker in a shorter internal than other green LED.

b. Function table of switches, jumpers and dip switch (located in DOC PCB)
No. Name Switches Function Usually
1 SW2 Slide switch WE : EEPROM writing + 5V position
2 RESET Tact Run CPU Reset
3 SPEC2 DIP SW(8P) Spec. setting 2
4 SPEC1 DIP SW(4P) Spec. setting 1
5 TMR1 HEX SW Light timer of car
Detects door zone in
6 NOR/ABNOR Jumper 6P Normal
emergency
DIR Selects rotary encoder
7 Jumper Pin
direction
8 SH Jumper Pin Terminal R setting 1 G/A
9 SM Jumper Pin Terminal R setting 2 G/A
10 SL Jumper Pin Terminal R setting 3 G/A
11 JP1 Jumper Pin Terminal R setting 4 G/A
12 SW3 Slide switch ANN(DOA-100) Power switch
Door open out of DR zone in
13 MAINT Jumper Pin Removed
Maint.OPR.
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 6/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

a) SW2 : WE position → EEPROM writing enable: when Spec. is changed into DOA
PCB at the side
+5V position → EEPROM writing unable : normal

Slide
+5V WE

※ After Spec. Modification, JP1 should be positioned on +5 to prevent the spec. data
from deletion.
b) Reset: Reset Run CPU, Speed CPU and LON CPU
c) SPEC setting 2 : SPEC2
SPEC2 Setting during ON Setting during OFF
1 Forcedly door closing is invalid Forcedly door closing is valid
2 Door time fixed(5 sec) Door time is flexible( SPEC data)
d) SPEC setting 1 : SPEC1
SPEC Setting during ON Setting during OFF
1 With duplex operation( DOC-131) Without duplex operation
2 Lift # 2( DOC-131) Lift # 1
3 Unused Unused
4 Load detector - Potentiometer Micro Switch(20%, 80%)
5 Setting to verification mode Normal position
6 Voice synthesizer exist Voice synthesizer none

7 Emergency(Fire) exist Emergency(Fire) none

8 In-factory checking mode Normal


※ Car ID setting for lift#1 and #2 is available only when 1st bit is ON.
checking mode of 5th bit is ON, checking points can be registered through
CRT monitoring system.
e) In-car light timer setting(TMR1)
BIT 0 1 2 3 4 5 6 7 8 9 A B C D E F
Seg. No limit 1 2 3 4 5 6 10 15 20 30 45 60 90 120 180
※ Factory set value is BIT A (30 min).
※ In-car light timer setting, is to set the time SPAN for in-car light to turn OFF when there is
no hall call or car call.
※ Setting Bit value to 0 means, light will be turned ON/OFF by switch.(Remains ON status)
※ The hexa switch is weak, be sure to use cross-shaped driver of a proper size.
f) DIR: Decision of the direction of rotary encoder. LEFT SHORT PIN
- Right arrangement: RIGHT RIGHT
DIR
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 7/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

- Reverse arrangement: LEFT


※ In case jumper pin is not jointed, System will consider that right direction.
g) SH: Terminal resistor setting for hall net
Set the terminal resistor at 'SH' at each elevator in case of single operation.
But in case of parallel operation, set as below.

E/L #1 E/L #2 Set SH Jumper pin in case of (1 line Hall Net).


Remove SH Jumper Pin But remove it in case of 2 line hall nets
SL CONN.

SH SH
Set Set In case of 2 rise
1st rise of Hall 2nd rise of Hall
Net Net

※ Do not set the terminal resistor 'SL' connector


※ In case of duplex system, remove SH jumper on both elevator, and set the hall type by
dip switch( SPEC1-7th pin ON) on DHG PCB of E/L #2

h) SM: Terminal resistance setting of supervisory panel.

E/L #1 E/L #2
Remove SM Jumper pin SM SM Set SM Jumper pin

SM SM

CRT
monitoring
panel

i) SW3: Power switch for ANN


Whenever it is connected to DOC PCB, surely turn off this switch if main power is turned
on. After ANN connection, turn on this switch. If you key in '0' 4 times on key pad, the
screen will be initialized.
j) MAINT: In order to open door beyond the door opening zone, you shall
(a) Set the AUTO/MAINT switch of DOC-131 PCB in control panel to MAINT.
(b) Insert a MAINT jumper.
Caution: Be sure to remove MAINT jumper short pin after installation at (high-
speed operation).
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 8/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

※ Function of each connector in DOC PCB


Connector Number of Pin Function
CA 18 PIN Car input signal and door input/output signal
CB 8 PIN Car side switch input
CT 18 PIN CTT wiring in Control panel(DOC-131)
AA 8 PIN Input in control panel
AF 8 PIN Switch Input in control panel(DOC-131)
AC 8 PIN Output in control panel (Relay drive)
AB 18 PIN Input and output(Relay drive) in control panel
HA 10 PIN Hoist way limit switch input
TB1 Terminal Block DC power supply in DOC-131 PCB
SD 4 PIN
ST 4 PIN RS-232 Serial Port(for HPC)
AD 4 PIN Rotary encoder power supply and signal
SH 4 PIN Hall board G/A communication
SM 4 PIN Monitoring panel & GEMS G/A communication
SL 4 PIN G/A communication in Parallel operation(DOC-131)
SC 2 PIN Car LON communication

k) NOR/ABNOR : Jumper that checking Door Zone in a rescue by handle


Normal position : NORMAL, Position during handle operation : ABNORMAL
Normal
48V 1 4

2 5
1
2 R5SC 3 6
Bz AA-05
3 Abnormal
CA-11 10 2

LDC CA-10 RLDC


$8025
+ Normal
4
5 1 4
6 - 2 5
GND
3 6
AA-06
DOC-131
Abnormal
(Fig1)
※ If 1-2 and 4-5 are connected by setting the switch to "Normal" in a normal
condition as shown above Fig.1, 48V power is input through LDC and processed
in LDC process section. If a rescue operation is required in case of power failure
or other errors, set the switch to "Abnormal". Then, the buzzer operated by battery
power will sound beyond door opening zone and will not sound in a door opening zone.
This function is very convenient for a manual rescue.
※ Reference : H/W SKELETON. " Hoistway Input Circuit Diagram"
※ Buzzer will not sound without R5SC relay is not energized, be sure to energize R5SC
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 9/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

※ Be sure to set main MCCB to OFF in a manual rescue operation.


※ Verify that the buzzer sounds beyond door opening zone with
this switch in Abnormal position during connection check.
※ Be sure to set the switch in Normal position after operation checking
3.2.3. Terminal Resistor
a. Terminal Resistor of Simplex

SH SH

Set of Terminal
Resistor

#32
DHG-162

#2
DHG-162

#1
DHG-162
Set of Terminal
Resistor
b. Duplex
a) Terminal Resistor of Duplex

DOC-131 DOC-131
SL SL
SH SH
Communication line
for Duplex
Remove jumper Set of Terminal
pin Resistor

#32 #32
DHG-162 DHG-162

#2 #2
DHG-162 DHG-162

#1 Set of Terminal Set of Terminal #1


DHG-162 Resistor Resistor DHG-162
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 10/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

b) Repeater PCB
A repeater PCB is applied to No.1 control panel in case the 2 Hall line and above 16
floors

Normal : Flickering Normal : Flickering

Abnormal : ON or OFF Abnormal : : ON or OFF

No.1 No.2

DOC-131 DOC-131
01 01
SL SL
02 02

TML3
05
06
GND
P24

Normal : ON

Abnormal : OFF

#17 #17
DHG-162 DHG-162

Above 16 floors Above 16 floors


#2 #2
DHG-162 DHG-162

#1 #1
DHG-162 DHG-162
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 11/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.2.4. Program IC (Board)


Program IC is likely to be removed or changed by light or static electricity as it is written
electrically. Much care should be taken in handling. DOC-XY TYPE sticker attaches program
element. X represents horizontal coordinate(1∼15) and Y vertical coordinate(A∼M)
a. DOC-131 PCB

① ② ③ ④ ⑤

The last version


V4.13

b. Program IC of DOC-131 PCB


Name Loc. Coor. Applied IC Function

U51(EVEN) ① 1A M27C1001,M27C2001 Contains driving CPU O/S and driving program

U52(ODD) ② 2A M27C1001,M27C2001 Contains driving CPU O/S and driving program

U55 ③ 3A 28C64 Sets spec.

U40 ④ 5C GAL22V10 Drives speed CPU and output side

U51 ⑤ 5D 27C256 LON CPU O/S and program


Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 12/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

z If each program has erased or damaged, following symptoms will happen


Name Function Symptoms

U51(EVEN) Operates run CPU SYS1 LED does not blink.

U52(ODD) Operates run CPU SYS2 LED does not blink.

U55 Sets spec. Floor information is garbled.

U40 OUTPUT DRV Each relay and contactor doesn't operate.


Operates LON
U51 LON CPU O/S and LON program communication is invalid
CPU

c. Checking point at failure


a) When SYSI LED doesn't flicker
- Verify that +5V voltage is within +4.65V~+5V.
- Verify that ROM (27C010) is properly inserted.
(Verify that even side and odd side are not switched.)
b) When no letter appears on LCD (Liquid Crystal Display) of DOA-100 PCB
- Verify that ANN connector is properly connected.
- Make LCD brighter by turning the variable resistance (VR1) of DOA-100 PCB
(New model has nothing)
c) When floor information can not be written
- Verify that the jumper of coordinate 3B is set to WE position.
(Writing is possible only with WE position)
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 13/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.3. DPC-122 PCB


3.3.1. Configuration and Diagram
a. Picture of DPC-122 PCB

Rom Version
V4.00(↑ )
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 14/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

b. Diagram of DPC-122 PCB


VA

DPC-122
+5V +15V -15V GND

Seg Connector Function Remark


VA POWER(+5,+-15,GND) DI1
VF POWER(+5,+-15,GND) DI2
VB HALL CT
VC C1VD Driving China
VD ALP Communication ALP
VE IO, I/F(DOC1XX PCB)
VG DPP 1XX PCB Connection
SPI

VG
Factory(PC MONITOR)
JTAG
VB

VDA DA CARD
VJ BRAKE Current Control SI

ALM
LED Indication Function Remark
LED1
OFF EL normal
H/W error detection Red
ON EL abnormal
ALM

CPU
1.Under Voltage detection
VJ

FLICKER(2/SEC) EL normal MONITOR LED2


2.CPU ERROR detection
Green
ON or OFF CPU error
CPU CPU error detection
FLICKER(2/SEC) CPU normal(stop)
FLICKER(4/SEC)

SPI
CPU normal(runing)
VC

JUMP Position Function Remark JTAG


MP NORMAL
JP1
MC Factory
D
V

WE ROM WRITE ENABLE ROM WRITE


JP2
NC NORMAL
SIGMA SIGMA Model SI
JP3
DI1,2 DI1,2 Model DI1,2
75/150[A]
DA CARD

JP4 IGBT TYPE IGBTCapacity


100/200[A]
VE

VD
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 15/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.3.2. Detail of DPC-122 PCB


a. Check connector connection before power input
In case of 60~105m/min, verify that connector VA (Control power), VB (CT), VC (C1VD),
VE (1/0,1/F), VG (GDC), VJ (DPC PCB = Brake control current) are connected.
※ VD(Used for ALP function), VDA(D/A CARD), VH(SERIAL) and VF(Control power for
120~150m/min) are not connected.
b. Check Jumper.
a) Setting of JP4
Verify that Jumper, inverter H/W over-current detector, are set according to below table

Jumper No. IPM Capacity Motor Capacity

No. 1 ~ 2 75A, 150A 4.4~7.5kw. 13~15kw


No. 3 ~ 4 100, 200AA 9.5~11kw. 18~22kw

b) Setting JP1
Jumper No. Function

MP Normal position
MC For factory

c) Setting JP3

Jumper No. Function

SIGMA For SIGMA(Si control panel) model


DI1,2 For DI model

d) Setting JP2
Jumper must be inserted to NC pin of JP2 at ordinary times
For the DSP writing, The jumper pin must shorted always at WE

Jumper No. Function

WE DSP SPEC Write(When input “A52E”)


NC Normal

c. Check control power when inputting power


a) As power voltage is set in the factory, checking is usually unnecessary.
If circuit operation is abnormal, check the voltage according to following table.
If the measured value is out of the regular range, never reset the value, and
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 16/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

Measure again with another instrument in case of measuring equipment failure.


b) Power input terminal
Measuring point Voltage Error correction

VA (+5V & GND) DC + 5V ± 2% 1. Verify that AC 93~122V is applied


to SMPS power input terminal
VA (+15V & GND) DC +15V ± 2%
2. Check the output voltage of SMPS
after removing connection between
SMPS and DPC PCB. If each power is
out of range from allowable error ±2%,
replace SMPS
VA (-15V & GND) DC -15V ± 2% 3. Check the output voltage of SMPS
after re-wiring between SMPS and DPC
PCB. if each power is out of range from
allowable error ±2%, replace SMPS
4. If SMPS is normal, replace DPC PCB

e. Check WDT
a) Verify that CPU LED(Green) flickers at 0.5 second interval with power ON.
b) The LED flickers at 0.25 second interval in motor operation.

Caution: WDT (WATCH DOG TIMER) monitors that the program calculation of speed control
CPU operates properly. If WDT does not flicker at 0.5 second interval during adjustment or it
remains ON or OFF the speed control CPU may seriously fail. Thus every error shall be
inspected thoroughly.

c) In such case, check 5V, ±15V power, ROM or ROM socket error, or connector
connection error.
f. Check ALM LED
a) Verify that LD1 ALM LED (Red) turn ON, and then, OFF after about 2 seconds. ALM
LED is for inverter H/W safety check and turns ON when the followings are detected.
(a) Over current is detected in inverter. (J5H Jumper is not inserted)
(b) WDT of speed control CPU has failed.
(c) U phase arm -short circuit of IPM or GATE SMPS power has failed.
(d) IGBT U-phase ARM is short-circuited and GATE PCB power has failed.
(e) IGBT V-phase ARM is short-circuited and GATE PCB power has failed.
(f) IGBT W-phase ARM is short-circuited and GATE PCB power has failed.
(g) Over current is detected on DC Link end.
(h) Regenerative IGBT and GATE transformer power have failed.
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 17/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

Caution: If ALM LED turns ON in inputting power and does not turn OFF, operation is
impossible. Perform an inspection according to the above ‘a ~ h’. as shown below.

b) Verify that JP4 Jumper is properly inserted.(If not inserted, ALM LED turns ON)
c) Verify that WDT LED is flickering normally.
d) In case of above ③ ~ ⑧ , check the connectors of DPC-122 PCB and verify that
GATE SMPS, GATE TRANS input is applied by AC 110V+10%,-15%..
e) Check IGBT stack or IPM connection conditions (disconnection and loose bolts)

g. Check C1VD contactor input (Option)


a) Verify that C1VD contactor is energized about 3 seconds later from power input.

Caution: If DC Link volt. does not reach 330V even after 8 sec. (Low- voltage error),
turn OFF C1VD contactor and then ON. Then, check the voltage after 8 seconds.
If the voltage is still low, turn OFF the contact and generate charging circuit
failure error.

b) In this case, main power circuit connection, GATE SMPS (Trans) input or connection,
charging circuit OFF, IPM, IGBT or regenerative IGBT ON may have failed.
Thus, check these conditions.

h. Cautions for adjusting of speed control gain value


a) Adjusting of speed control gain value affects riding comfort and leveling accuracy of the
car.
b) Use accelerator to change gain.
c) Speed control gain can be changed within -50 % ~ 150 %. (Refer to Annunciator data)
d) High gain value causes excessive vibration and low gain value causes stalling or starting
shock.
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 18/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.4. DPP-150(140) PCB


3.4.1. Diagram of DPP-150 PCB

Seg Function
GU1 15V
GU2 Ground U

Seg Function
GV1 15V
GV2 Ground V
Connected to 'VG'
Seg Function connector of DPC PCB

GW1 15V
GW2 Ground_W

Seg Function Caution


GX1 15V
GX2 Ground W
Don't touch
GX3 -9V
stack when light
ON after power OFF.

Seg Function
Seg Explanation
TH1 Thermal1
GW1 Over 50V on DC link
TH2 Thermal2
GW2 Below 50V on DC Link

( DPP-150 )
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 19/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

( DPP-140 )

3.4.2. Main function


Item Description
Detects short just like arm short-circuit, IPM & IGBT short within
Detecting short-circuit
5~6㎲ by output short, and outputs an error signal.
Cuts driving circuit within 10㎲ after a short-circuit is detected.
GATE soft cut circuit This process is carried out slowly for 10㎲ to protect IPM & IGBT
from spike voltage resulting from short circuit.
When a short-circuit is detected, the timer starts counting at the
same time that GATE cut circuit operates and turns off 10~20ms. Driving output is
Timer & reset circuit cut regardless of the input signal of driving circuit until timer finishes.
When the input signal of driving circuit is OFF after timer finishes,
resetting circuit operates and stops the cut state.
Detecting the power voltage Breakdown of power circuit and 15V power is drop to 12±0.5V during power
error failure. It displays error.
IPM 50A & 75A : DPP-150, IPM 100A & 150A : DPP-140
Driving circuit
IPM 200A : DPP-111
Overheat detection If radiating plate temp. reaches 85℃, it detects error.

Detecting error of IPM inner Maintains breakdown condition about 2ms when IPM error occurs
side at its inner side
3.4.3. Variable resistance
a. OV variable resistance sets DC Link over current level. The factory setting is 770V.
This setting may be changed temporarily for testing by turning the volume.
After testing, be sure to return to the origin position.
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 20/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

* Measuring point => TE40 and TE100 on DPP-150(140) : 7.9±0.5V


b. BR(brake) variable resistance sets regenerative operation starting voltage level.
The factory setting is 730V. This setting may be changed for testing by turning the volume.
After testing, be sure to return to the origin position. Each end of C12 is 7.6+/-0.5volt.
* Measuring point : TE40 and TE70 on DPP150(140): 7.5 ±0.5V
c. In case of DPP-111, the potential difference between regenerative voltage and over
voltage should be 0.25~0.36V.
* In case of DPP-150, variable resistance adjustment point is not exist.
3.4.4. Connector and connection checking before inputting power
a. Checking the type name of DPP-150 PCB according to IGBT capacity shown below.
PCB type name IPM, IGBT capacity

DPP-150 L-IPM 50,75A


DPP-140 L-IPM 100, 150A
DPP-111 IGBT: 200A
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 21/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

b. Check the connection condition of each connector. Verify that all connectors are
connected to their proper positions.

3.4.5. Checking of the control power when inputting power


Caution: As DC link voltage (500~700V) is input to DPP-150 PCB after inputting power,
special attention should be paid to safety.
a. Usually control voltage needs no checking. If any error is found in circuit operation, verify
that GATE SMPS or GATE TRANS input is within AC110±10% and check the connectors.
3.4.6. Charging (discharging) LED function
a. LED (Red) on PCB lights ON if DC Link voltage is 50V or more and it and dims
(goes) lights OFF if the voltage is less than 50V. LED lights ON again when the DC link
begins to be charged with FFB is inputted
Caution: As it takes about 15 seconds for DC Link voltage to be discharged completely
after power OFF, never touch DPP PCB and stack while LED light is ON.
b. When LED does not light ON though main power is inputted,
IPM & IGBT short, or regenerative IGBT OFF error, wrong wiring of recharge
resistance(RCR), Recharging circuit ON error, or luminescent diode may damaged.
Inspection should be carried out after DC link voltage discharged.
* DC Link voltage is condenser power, Surely check the voltage for safety.

3.5. DCL-243 PCB


3.5.1. Function
※ DCL-243 PCB is car operation PCB(CLON) mounted with MC143150BIFU
neuron chip and is applied to Si control panel.(Si210, Si220, Si230)
a. Installed in OPB in single elevator and forms a serial communication network with
CNL LON of CP
b. Detects call button in car, open, close and ex_open (elongates door close time for 3
minutes and closes the door regardless of door time with a close button registration)
buttons, control board switch, on car connection box switch input, and car load, and it
transmits them into DOC PCB through network.
c. Controls car call B/T, open, close and ex_open response lamp and Up/Down direction
lamp, full lamp, CPI, and car-chime(gong) with display commands through the network
of DOC PCB.
d. The additional command signals from CP that are related with door are transmitted to
DCD PCB. And it receives some error signals of door through parallel communication
for easy installation & maintenance
e. It transmits voice synthesis guide data to the voice synthesis board in OPB through
LCD connector.
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 22/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

f. Functional Classification
No. Classification Item Specification
1 Connection Signal
2 Memory ROM One 27C256 32K Byte
1) Non voltage switch input by comparator : 39EA.
Car call button input:32 floors(MAX. 64 floors)
Open, close, ex-open button: 1 respectively
Up, down, start, bypass button on OPB: 1 respectively.

Input 2) Voltage switch input by comparator : 24


OPB switch:15. On car connection box switch:5
Car load detecting switch: 3. Photo shoe switch: 1
3) Analog ~ digital converter input: 4 channels
3 Input/ Output Potentiometer: 2.
1) TR driving by I/O mapped I/O method: 7
CPI driving: 3. 110% overload buzzer driving: 1
Chime 1,2 strike driving: 2. LCD back light: 1
2) TR driving by memory mapped I/O method: 39
Output
Car call button response lamp: 32
Open, close and ex-open response lamp: 3
Up, down and full lamp on operating board: 3. Button
buzzer: 1

Voltage +24V±5%
4 DC power
Current TYPE 3 A
5 PCB spec. Size 239×133.3mm
6 Switch SW1 Car operation board ID setting
7 Environment Oper.tem. 0 ℃ ~ 70 ℃
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 23/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.5.2. Diagram of DCL-243 PCB


a. Outward appearance
DRIN,DROUT: related distributed door

POT: Potentiometer CBL: Connector for 64 fl extention

LCD : Voice
IND : CPI synthesis guide
connection device(DCV-100)

CCN1 : MAIN LD1:LED for PCB


Connector state indication

SW1:ID setting,
terminal resistandce
U1:NEURON
setting
CHIP

U2:DCL
ROM
DFTR : Differen.
trans. input

LAMP:UP,DOWN,
FULL LAMP
CIN:IN-CAR
(OPB)input OP:OPEN
B/T & LAMP

EOP:EX OPEN
B/T & LAMP
ONC:ON-
CAR INPUT CL:CLOSE
B/T & LAMP

BZ1:CALL
B/T BBZZER

① ② ③ ④ ⑤ ⑥ ⑦ ⑧

① CB1:CALL BUTTON 1~8F ⑤ CB3:CALL BUTTON 17~24F

② CL1:CALL BUTTON LAMP 1~8F ⑥ CL2:CALL BUTTON LAMP 17~24F

③ CB2:CALL BUTTON 9~16F ⑦ CB3:CALL BUTTON 25~32F

④ CL2:CALL BUTTON LAMP 9~16F ⑧ CL2:CALL BUTTON LAMP 25~32F


Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 24/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.5.3. Setting of DCL-243


a. Serial communication line (CCN1) connection
※ DCL-243 PCB application to sub & disabled type OPB is possible but we mainly apply it
to Main OPB.

DOC-131 PCB

SC-01,02

SC-01,02
DCL-243 PCB

CCN1-01,02

SC-01,02

Junction Box

SC-01,02 SC-01,02

3.5.4. DCL243 and multi PCB


a. Application table of DCL-243 & Multi PCB
OPB lineup Amount of PCB

Front main Front sub Disabled main Disabled sub DCL-243 Multi PCB

O X X X 1EA NIL

O O X X 1EA 1EA

O X O X 1EA 1EA

O O O X 1EA 1EA

O O O O 1EA 1EA

a) TD62083AF Output Current Maximum Rating: 500mA/ch


b) OPB B/T LED Ideal Forward Current Maximum Rating: 40mA/per
c) Multi PCB is located at main OPB and connected to DCL24X.
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 25/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

b. Connection diagram
a) Diagram

Main OPB Sub OPB #1 Sub OPB #2 Sub OPB #3

DCL-24x

Button Button Button


Multi-PCB

Lamp Lamp Lamp

Button

Lamp

Jack Jack Jack Jack

Connect in installation

b) Terminal resistance is set on the final end of communication line.

c. Check LED indication


※ LED-LD1 indicates DCL-243 PCB operation condition as shown below.
NO Indication Conditions required Remarks
No P24V power, PCB(H/W)
1 OFF CPU run error, COMM. error
error, etc.
Comm. line connection error,
2 ON(1 sec.interval) CPU run normal, COMM error DIP SW car operating board ID
and TML R setting error

ON(0.3
3 CPU run normal, COMM. normal
sec.interval)

d. Main OPB ID check by CPI when main power turned on.


a) Check if DCM-11X or 12X is connected to DCL-243 PCB
b) The ID of main OPB "01" will be displayed on DCM-11X or 12X when main power
turned on.
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 26/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.6. DOP-116 PCB


DOP PCBs are the power source PCB of DI 1(60~105) E/L. This is the source of
DC 24V(Car LON PCB), DC 48V (Relay, outer signal input I/F power), DC110V(C1ST,
C1BR, C1VD contactor power) and AC power source and fuse.
This also displays the fuse condition

3.6.1. Applicable drawing

Type Assembly drawing Application

DOP-116 AEG05C281*A For unified type control panel(SDB1)

AEG05C281*B For unified type control panel(SAV1,MAV1)

AEG05C281*C For unified type control panel(DAV1,HAV1)

3.6.2. Input / Output of DOP-116 PCB


Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 27/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.6.3. Input / Output of DOP-116 PCB


a. 3 Phase I/O part

변경
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 28/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

b. Single Phase I/O part

* 주기1.
* 주기1.
SBD1: 5[A]
SAV1,MAV1: 3[A]
DAV1,HAV1: 6[A]
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 29/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.7. DOR PCB


3.7.1. DOR-100C PCB
For emergency of domestic(Korea)

3.7.2. DOR-110 PCB


As for relay connection PCB, this PCB is used when fire control option is applied. And
R4FMX will be applied to system in case 2nd pit switch is applied to elevator.
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 30/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.7.3. DOR-101 PCB


As for relay connection PCB, this PCB is used when supervisory panel is applied.
R4FSX Relay is only for Korea domestic.

3.7.4. DOR-120 PCB


As for relay connection PCB, this PCB is used when generator control option is applied
to elevator.
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 31/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.7.5. DOR-131 PCB


As for relay connection PCB, this PCB is for standard
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 32/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.8. DCV-100 PCB


3.8.1. DCV-100 PCB (Auto voice synthesizer device)
a. Function
DCV-100 PCB is for voice synthesizer. It is composed of CPU (PIC16C63, PIC16C73),
RS232C communication, DA conversion, amplification, and power detection & battery
section.

b. Diagram of DCV-100 PCB

CN2: Parallel Communication.. VR2: Volume for Night time

SW2

CN3: For
Speaker

CN1: For Power VR1: Volume for Day time

c. System configuration
※ DCV-100 PCB configuration
a) Communication. Method: Parallel Communication,
b) CPU: AT90S2313
c) MEMORY: ROM(27C040) → Voice data stored
d) D-A converter: Converts digital voice data to analog data
e) Amplifier: Amplify analogized data and outputs through speaker
(Max.output:2 Watt, 8Ω )
f) In case DCV-100 PCB is applied, check the spec data

Address DOV-200 DCV-100 OS Rom version


0014 01 00 V2.06 (↑ )
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 33/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

d. Spec. setting
a) Spec. setting method: Spec. can be modified by DIP SW(SW2).
* Bit allocation chart
Seg
Bit 1~4 Bit 5 Bit 6 Bit 7 Bit 8
.
ON :Chime
Refer the below "
ON : is operated
Func EX)" for ON : Announcement for ON : Announces
Announcement before
tion. underground floor 13F is omitted "Thank you"
for 4F is omitted Announcem
setting
ent

1 2 3 4 5 6 7 8
Ex.) In case
underground On
floor is B4

Off

* In case the lowest floor is 1st floor, please turn off DIP SW No. of 1~4

Underground Underground
Dip SW Dip SW
(=lowest) floor (=lowest) floor

B1 ON: 1st B4 ON: 3rd


B2 ON: 2nd B5 ON:1st & 3rd
B3 ON: 1st&2nd B6 ON:2nd & 3rd

※ Once the underground floor is set, other floors are set automatically.
b) Announce recordings in sequence with bits 1~4 turned ON.
Thus, voice synthesizer can be tested with this bit 1~4 in factory or field.
※ Be sure to turn them OFF after testing.
c) Bit 5 and Bit 6 should set same as floor setting spec. of the building.
d) Bit7 sets addition or deletion of chime before broadcasting depending on user's
requirements.
e) Bit8 sets addition or deletion of 'thank you' message depending on user's requirements.
e. Volume adjusting switch
a) Adjusting method of day volume: Enable bits 1,2,3,4
Turning the volume (VR1) to clockwise will decrease volume sound (opposite direction
will increase volume)
After volume adjustment, bits1~4 should be set again referring above d.
b) Adjusting method of day volume: Enable bits 5,6,7,8
Turning the volume (VR2) to clockwise will decrease volume sound (opposite direction
will increase volume)
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 34/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

After volume adjustment, bits5~8 should be set again referring above d.


f. Power failure detection
DCV-100 PCB detects power failure and announces power failure (twice).
As power failure announcement uses local battery,
g. Indicator (LED1)
LED1 : Indicates status of power. Lights ON with power ON.
h. Connector connection
a) CN2: For communication (CN2-LCD connector of DCL-243 PCB)
b) CN1: For power supply and
c) CN3: For Speaker

CN2
LCD

DCL-243

CN3

DCV-100

Speaker

CN2 Function J2 Function CN1 Function


1 GND 9 D2 1 P12
2 P5 10 D3 2 P24
3 NC 11 D4 3 G12
4 A0 12 D5 4 G24
5 GND 13 D6
6 CS 14 D7 CN3 Function
7 D0 15 NC 1 Speaker1
8 D1 16 NC 2 Speaker2

i. Check points before operation


a) Check J1 connector for power (24V, GND) connection.
b) Check power switch and LED1.
c) Check speaker and matching transformer connection.
(The rating of speaker matching transformer is 16Ω /8Ω .)
d) Verify that BIT6 in DOC PCB (Spec. setting DIP SW) is ON.
e) Verify that data of SPEC address "0034","0036" are"0xFF".
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 35/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.9. DPB-110 PCB


3.9.1. Diagram of DPB-100 PCB
a. Function: Control of brake on/off

TP1

LED
TP2

b. Main I/O of DPB-100 PCB


a) "VK" Terminal(6P) b) "VJ" Connector(MOLEX,10P)
NO Function NO Function
1 Brake Coil_B 1 P4.5V
2 Brake Coil_A 2 BK_PWM
3 C1BR_N 3 BR_UV
4 P110V 4 BR_OC
5 C1BR_P 5 BK_I
6 EARTH 6 P5
7 GND
8 N15
9 P15
10 GND
※"VK" is connected to "VK" of DOM PCB, and "VJ"
is connected to "VJ" of DPC PCB
c) LD1(LED)
P110V is power input checking LED. When it is
inputted to "VK-04", LED will be turned on.
d) TP1,TP2(CHECK PIN) : It must
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 36/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.10. DCM-1XX PCB


3.10.1. Layout of DCM PCB

Additional Lamp3
DOT of 1st digit(1 place)
displaying Additional Lamp1

DOT of 2nd digit


(10 place) displaying Additional Lamp2 HI: IND I/F

Direction displaying DOT


Additional Lamp4

3.10.2. Function and feature


DCM-1XX PCB receives serial data from DHG-162 and DCL-243 PCB to DOT IND, and
displays current elevator position, direction and additional information.
a. It receives serial data as clock and enable signal from DHG-162 or DCL-243 PCB, and
drives DOT and additional lamps.
b. It can display not only numbers but also alphabet (capital letter and small letter).
c. It can drive 4 of additional lamps.
d. Button energy saving mode function (It can be adjustable by SPEC in DOC PCB, only
for VIX-532 type Indicator)
e. Power
DC 24 V is used for display drive power which is supplied from DHG-162 DCL-243
PCB, and using for logic power by stepping down DC24V to DC5V.
f. PCB types and application scope
a) DCM-1XX PCBs in Sigma elevators can be classified to DCM-10X, DCM-11X and
DCM-12X (3 types)
b) The usage purpose of additional lamp is classification standard.
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 37/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

Table) DCM PCB list


PCB Drawing No. Usage Additional Lamps

DCM-102 AEG00C767*A Slim vertical (Sigma standard) 2EA (LAMP1,4)


DCM-103 AEG00C767*B Slim vertical (Sigma standard) 3EA (LAMP1,2,3)
DCM-114 AEG00C769*A Horizontal CPI (Sigma standard) 0EA
DCM-115 AEG00C769*B Horizontal CPI (Sigma standard, EME) 1EA(LAMP2)
DCM-116 AEG00C769*C Horizontal CPI (Sigma standard) 2EA(LAMP1,3)
DCM-117 AEG00C769*D Horizontal CPI (Only Korea Domestic) 3EA(LAMP1,2,3)
DCM-124 AEG00C770*A CPI, Mounted on OPB (Sigma standard) 0EA
DCM-125 AEG00C770*B CPI, Mounted on OPB (Sigma standard, EME) 1EA(LAMP6)
DCM-126 AEG00C770*C CPI, Mounted on OPB (Only Korea Domestic) 3EA(LAMP3,4,5)
DCM-127 AEG00C770*D CPI, Mounted on OPB (Only Korea Domestic) 4EA(LAMP1,2,3,4)

g. Connectors
a) DCM-10X b) DCM-11X, 12X
Name Pin No. Signal Name Pin No. Signal
1 DC24V 1 DC24V
2 GND 2 GND
3 DATA 3 GND
HI HI
4 CLK 4 DATA
5 ENABLE 5 CLK
6 ENABLE
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 38/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.11. DHG-162 PCB


3.11.1. In case 1 floor is under controlling of 1 DHG-162
DHG-162 PCB can control 1 floor or 2 floors(Upper & Lower floor)

a. A DHG-162 PCB is applied to every floor in case of following condition


a) N-Plex operation
b) Through type
c) In case Hall Lantern is applied
d) In case Hall Chime is applied
e) In case disable Hall button is applied
f) In case floor height is over 4m, apply 1 more DHG-161

b. Function of Mic

HC1: Hall chime for No.1

HF2: Hall lantern for No.2 HC2: Hall chime for No.2 HP: Parking

HF1: Hall lantern for No.1 HVF: VIP or Fire

HI2: Indication
for No.2

HI1: Indication
for No.1

HA(Hall Communication & SW2 SW1


Power Source) HU: Up Hall Button HDC: Disable Down Hall Button
HD: Down Hall Button HUC: Disable Up Hall Button

3.11.2. In case 2 floor are under controlling of 1 DHG-162

a. HUC, HDC, HF2, HC2, HI2 are used for upper floor
b. It composes serial communication network with DOC-131 PCB at hall under single
elevator system.
c. It transmits hall button and switch inputs to DOC PCB through network.
d. It drives hall button lamps, indicators, hall lanterns and hall chimes with receiving
output signal form DOC PCB
e. It has a watch dog timer (LED2) that checking CPU down.
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 39/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

f. LED1 checks the communication condition.


g. Function of Mic

HC1: Hall Chime for lower floor


HF2: Hall lantern of No.2 HC2: Hall chime for upper floor HP: Parking

HF1: Hall lantern of No.1 HVF: VIP

HI2: Indication
for upper floor

HI1: Indication
for lower floor

HA(Hall Communication & SW2 SW1


HDC: Down Hall Button
Power Source) for upper floor
HU: Up Hall Button for lower floor
HD: Down Hall Button for lower floor HUC: Up Hall Button for upper floor

3.11.3. Dip Switch function


a. Setting DIP switch1

ON

OFF
1 2 3 4 5 6 7 8

Floor ID Setting Button Type

※ Setting the ID is possible, 63 maximum, by using Floor ID setting segment(No.1~6).


(OFF condition does not exist.)
b. Button type setting by using button type segment(No.7~8)
Table11-20

Dip Switch 1 setting


Button type
7 8
Second hall Net of duplex or rear
On Off
side of through type
Simplex or Lift No. 1 of duplex front
Off Off
side of through type
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 40/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

c. Dip Switch 2 setting


ON

OFF
1 2 3 4

On: In case VIP button is installed at upper floor

Off: In case VIP button is installed at lower floor


On: In case 2 floors are under controlling of 1 DHG-162

Off: In case 1 floor is under controlling of 1 DHG-162

d. Example of dip switch setting for simplex control

SW1 SW2

ON ON

5th
1 2 3 4 5 6 7 8 1 2 3 4 Floor

1) #1, #3 of SW1 are on for 5th floor setting.


2) #1 of SW2 is off because 1 DHG-161 controls 1 floor.

ON ON
4th
Floor
1 2 3 4 5 6 7 8 1 2 3 4

1) #1, #2 of SW1 are on for 3rd floor setting.


(Lower floor is reference, upper floor is set automatically)
2) #1 of SW2 is on because 1 DHG-161 controls 2 floor. 3rd
Floor

2nd
ON ON
Floor

1 2 3 4 5 6 7 8 1 2 3 4

1) #1 of SW1 are on for 1st floor setting.


(Lower floor is reference, upper floor is set automatically) 1st
2) #1 of SW2 is on because 1 DHG-161 controls 2 floor. Floor

- Verify the state of dip switches, which is OFF (state when delivery) before operating.
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 41/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

e. SPEC check and standard DHG-162 PCB application


In case the distance from lower floor to upper floor is bigger than 4m, one more DHG-162
PCB is applied to hoistway with distribution box.
※ Added spec data
Note(*H: Hexadecimal, *B: Binary, No: Decimal, 00H: N/A, 01H:
Addres Applied)
Part Label
s
Data Description Default
Hall Double In case that 2 floors are under control of
0636H *H 00H
node _DHG 1 DHG-161
A side (#7 of SW1 of DHG-161 is off)
0900H Aside_ 0900H 1st ~ 8th floor 00H
0902H Hall_ *B 0902H 9th ~ 16th floor 00H
0904H Station 0904H 17th ~ 24th floor 00H
Hall
Call 0906H 0906H 25th ~ 32th floor 00H
SVC B side (#7 of SW1 of DHG-161 is on)
0908H Bside_ 0908H 1st ~ 8th floor 00H
090AH Hall_ *B 090AH 9th ~ 16th floor 00H
090CH Station 090CH 17th ~ 24th floor 00H
090EH 090EH 25th ~ 32th floor 00H

Example1) 12 floor 12 stop, simplex, normal hall button, 5m height between B3 & B2.
SW1 SW2
Floor DHG-162 installed floor Connection of button
1234 5678 1234
9th floor Installed (For 9th floor) 1101 0000 0000 Connect to 'HD'
8th floor Connect to 'HUC' & 'HDC'
Installed (For 7th, 8th floor) 0101 0000 1000
7th floor Connect to 'HU' & 'HD'
6th floor Connect to 'HUC' & 'HDC'
Installed (For 5th, 6th floor) 0001 0000 1000
5th floor Connect to 'HU' & 'HD'
4th floor Connect to 'HUC' & 'HDC'
Installed (For 3rd, 4th floor) 0110 0000 1000
3rd floor Connect to 'HU' & 'HD'
2nd floor Connect to 'HUC' & 'HDC'
Installed (For 1st, 2nd floor) 0010 0000 1000
1st floor Connect to 'HU' & 'HD'
B1 floor Connect to 'HUC' & 'HDC'
Installed (For B1, B2 floor) 0100 0000 1000
B2 floor Connect to 'HU' & 'HD'
B3 floor Installed (For B3 floor) 1000 0000 0000 Connect to 'HD'

PCB installed floor 5th 4th 3rd 2nd 1st B1 B2 B3 Data

SPEC Address '0900'H 1 0 1 0 1 0 1 1 'AB'H


Data Set PCB installed floor 9th 8th 7th 6th Data
Address '0902'H 0 0 0 0 1 0 1 0 '0A'H
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 42/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

Example2) 7 floor 7 stop, duplex, lift #1 normal hall button, lift #2 normal hall button.
[Lift #1 setting]
SW1 SW2
Floor DHG-162 installed floor Connection of button
1234 5678 1234
7th floor Installed (For 7th floor) 1110 0000 0000 Connect to 'HD'
6th floor Connect to 'HUC' & 'HDC'
Installed (For 5th, 6th floor) 1010 0000 1000
5th floor Connect to 'HU' & 'HD'
4th floor Connect to 'HUC' & 'HDC'
Installed (For 3rd, 4th floor) 1100 0000 1000
3rd floor Connect to 'HU' & 'HD'
2nd floor Connect to 'HUC' & 'HDC'
Installed (For 1st, 2nd floor) 1000 0000 1000
1st floor Connect to 'HU' & 'HD'
[Lift #2 setting]
SW1 SW2
Floor DHG-162 installed floor Connection of button
1234 5678 1234
7th floor Installed (For 7th floor) 1110 0010 0000 Connect to 'HD'
6th floor Connect to 'HUC' & 'HDC'
Installed (For 5th, 6th floor) 1010 0010 1000
5th floor Connect to 'HU' & 'HD'
4th floor Connect to 'HUC' & 'HDC'
Installed (For 3rd, 4th floor) 1100 0010 1000
3rd floor Connect to 'HU' & 'HD'
2nd floor Connect to 'HUC' & 'HDC'
Installed (For 1st, 2nd floor) 1000 0010 1000
1st floor Connect to 'HU' & 'HD'

[Spec data : Lift#1 & #2]


Note(*H: Hexadecimal, *B: Binary, No: Decimal, 00H: N/A, 01H:
Addres Applied)
Part Label
s
Data Description Default
Hall_
Call
08E0 Service *H “A” side & “B” side C3
SVC
_Map
Hall Double In case that 2 floors are under control of
0636H *H 01H
node _DHG 1 DHG-161
A side (#7 of SW1 of DHG-161 is off)
0900H Aside_ 0900H 1st ~ 8th floor 55H
0902H Hall_ *B 0902H 9th ~ 16th floor 00H
0904H Station 0904H 17th ~ 24th floor 00H
Hall
Call 0906H 0906H 25th ~ 32th floor 00H
SVC B side (#7 of SW1 of DHG-161 is on)
0908H Bside_ 0908H 1st ~ 8th floor 55H
090AH Hall_ *B 090AH 9th ~ 16th floor 00H
090CH Station 090CH 17th ~ 24th floor 00H
090EH 090EH 25th ~ 32th floor 00H
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 43/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.11.4. Hall connection of Simplex(In case 2 floor are under controlling of 1 DHG-162)

DHF-100
HFU
HF HFP
HFD

5F

DHF-100
SW1 DHG-162 HFU
HUC HF1 HF HFP

HDC HF2 HFD

SW2 HC1 HU

HC2 HD
HI2 HI1
4F

DHF-100
HFU
HF HFP
HFD

3F

DHF-100
SW1 DHG-162 HFU
HUC HF1 HF HFP

HDC HF2 HFD

SW2 HC1 HU

HC2 HD
HI2 HI1
2F

DHF-100
SW1 of DHG-162 DHG-162 HFU
HUC HF1 HF HFP

HDC HF2 HFD

SW2 of DHG-162 HC1 HU

HC2 HD
HI2 HI1
1F
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 44/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.11.5. Hall connection of Duplex(In case 2 floor are under controlling of 1 DHG-162)

DHF-100 DHF-100
HFU HFU
HF HFP HF HFP
HFD HFD

5F 5F

HFU HFU
HF HFP HF HFP
HFD HFD

SW1 DHG-162 SW1


HUC HF1 HUC HF1
HDC HF2 HDC HF2
SW2 SW2
HC1 HU 4F 4F HU HC1
HC2 HD HD HC2
HI2 HI1 HI2 HI1

HFU HFU
HF HFP HF HFP
HFD HFD

3F 3F

HFU HFU
HF HFP HF HFP
HFD HFD

SW1 DHG-162 SW1


HUC HF1 HUC HF1
HDC HF2 HDC HF2 SW2
SW2
HC1 HU
2F 2F HU HC1
HC2 HD HD HC2
HI2 HI1 HI2 HI1

HFU HFU
HF HFP HF HFP
HFD HFD

SW1 DHG-162 SW1


HUC HF1 HUC HF1
HDC HF2 HDC HF2
SW2 SW2
HC1 HU
1F 1F HU HC1
HC2 HD HD HC2
HI2 HI1 HI2 HI1
Part. PCB
Di1(Si210) Elevator Ctrl. No. SI-SR-01-2

FOD Page 45/49


Overseas Support Team
Start-Up Routine Date Mar. 2009

3.11.6. Hall connection of through E/L(In case 1 floor is under controlling of 1 DHG-162)

Front Door Rear Door

SW1

SW2

HFU
HF HFP
HFD
SW1
HUC HF1
HDC HF2
SW2
HC1 HU
5F 5F
HC2 HD HFU
HI2 HI1 HFP HF
HFD

HF1 HUC
HF2 HDC
SW1
HU HC1
4R HD HC2
4F
DHF-100 HI1 HI2

HFU
HF HFP
HFD
DHG-162
SW1
HUC HF1
HDC HF2

HC1 HU SW2
3F 3F
HC2 HD
HI2 HI1 HFU
HFP HF
HFD

HF1 HUC
SW1
HF2 HDC
2F HU HC1
SW2 2R HD HC2
DHF-100
HI1 HI2
HFU
HF HFP
HFD
DHG-162
HUC HF1
HDC HF2

HC1 HU
1F 1F
HC2 HD
HI2 HI1