Changes and Impact - Chapter 7, 8
Changes and Impact - Chapter 7, 8
Changes and Impact - Chapter 7, 8
7.5.7.3 Engineered fill and table 7.4, new zone… ( all new)
! at 7.5.7.4, the Group I, II and III and Table 7.5 (new; )
Check with box culvert first.
Table 7.6 equal old table 7.5 etc..
7.5.7.5 new placement and compaction requirement/ new soil compaction requirement…
7.5.7.7.2 camber -> former 7.5.4.3(simplified, camber for post-settlement invert slope that …)
7.6.4 Foundation material treatment requirement for pipe arches. (like former 7.6.4.2 , but clarified the P requirement)
Table 7.10 updated – added three-sided structure and took out manholes/CBs
7.8.4.5.2 add req for standard trench and embankment installations-- shortened.
Chapter 8
8.4.1.1 added compliance to A23.4 (for PC)
8.4.1.2.2
8.4.1.7.4 Creep coefficient –equation changed, i.e. term f’c+a -> fcm, the rho and B are different, added the adjusted time scale factor.
8.4.2.1.1 no longer allow 300 Mpa etc and has to be W. no R grade.
8.4.3 Tendon ( no CSA< shall be ASTM; (the commentary is did not say why)
8.5.2.2 Cracking requirement expanded
~fsf is not in the definition but embedded in 8.5.3.1 (should this be the sustained tensile force?)
8.5.3.2 Tendon FLS ( tablized.)
8.6 design consideration, 8.6.2 design, 8.6.2.2 Member Stiffness, (added condition to use linear-elastic method; no material difference)
8.6.2.3 Imposed deformations (the 60% assumption and equation gone! (not in commentary either); need actual precise analysis)
8.6.2.4 Redistribution of force effect (the limit for non-linear analysis removed)
//8.9.3.7. Beta and theta. the beta graphics has issue, theta r not a function of sze any more…
8.9.3.9 regrouped ; longitudinal rebar in flexural tension zone (added reduction requirement in 8.9.3.9.1 and 8.9.3.9.2 from A23.3!!).
8.9.4.3 Two-way shear equation changed..
Figure 8.5 added to explain clause 8.10.6
Table 8.4 about the water cement ratio requirement missing? And not labeled.
Table 8.5 changed (cover and foot note… be careful—i.e . deck top is now 65 +5 or 10 or 0)
8.12.1 control of cracking applicability revised. (8.10 is the strut and tie, 8.18 is the deck..)
8.12.3 crack control reinforcement (completely different concept; based on zone and stress.. )
f) is new but make sense g) is new but was basically at the former main paragraph)
Added a Requirements (clarify the overhang, composite system, diaphragm, edge stiffening; some in former 8.18.1 already)
8.18.3.3 CIP deck requirement ( same as 8.18.4.2~ except i.e. approved by owner)
8.18.3.4.2 partial depth PC panel (rearranged and added requirement, i.e. change - b) min 90mm, c) effective span per k) (not 150) , f) grouped (new rho limit (not e), strand space)
8.18.3.5 Full depth precast panel (per former 8.18.4.4, but allowed passive (non post-tensioning))
8.18.4 Diaphragm ( same as former 8.18.5)
Edge stiffening, distribution rebar… same content but shifted location.