Professional Documents
Culture Documents
4124 Aa DC 21710i002s01 Is01 - Checkprint
4124 Aa DC 21710i002s01 Is01 - Checkprint
GEOGRAPHIC
N
NORTH 0°
PREVALING
22.377°
PREVALING
WINTER WIND
S/E
180° 1710-SS002I
PAVING CONCRETE QUANTITY
1 MATERIAL TOTAL QUANTITY [Cu. M]
PAVING CONCRETE 2.16
300
FOUNDATIONS F/W-R/F TYPES 1) ALL DIMENSIONS ARE IN MILLIMETERS, ELEVATIONS & CO-ORDINATES ARE IN METERS.
OF PED.
F/W TYPE R/F TYPE QUANTITY 2) EL.100.000 = +23.00m ABOVE AVERAGE BALTIC SEA LEVEL IS REFERRED TO THE H.P.P (High Point Paving)
1710-SS002I
250
1 1 MK4-1Ø16 MK3-1Ø16 PFJ001 RFJ001 1
3) FOR GENERAL NOTES FOR CONCRETE WORKS REFER DWG. NO. 4124-AA-DX-200000001
450
==
B
- - MK3-1Ø16 MK4-1Ø16
4) BAR BENDING SCHEDULE IS INDICATIVE .CIVIL SUB-CONTRACTOR IS RESPONSIBLE FOR CHECKING
REBAR QUANTITIES & DIMENSION ACCORDING TO DRAWINGS.
FP-002A MK2-5Ø16@200
FPJ001
MK1-13Ø16@200
FOUNDATIONS TYPE SCHEDULE
RFJ001
ABJ001 ITEM TAG F/W TYPE R/F TYPE
3 3 3 3 1710-SS002I-PF001A PFJ001 RFJ001
E = 363.955
2300
1800
- FP-001A - - -
FPJ001
RFJ001
ABJ001
PEDESTAL F/W-R/F TYPES
F/W TYPE R/F TYPE QUANTITY
OF PED.
FPJ001 RFJ001 2
1710-SS002I
1 N = 315.375 1
= =
450
A
- -
250
PFJ001
ITEM TAG LxW [mm] F/W TYPE R/F TYPE
RFJ001
MK6-1Ø16 1710-SS002I-FP001A 450x450 FPJ001 RFJ001
450
MK5-1Ø16 1710-SS002I-FP002A 450x450 FPJ001 RFJ001
= =
SECTION 1 SECTION 3
(SCALE: 1 : 25) - (SCALE: 1 : 25) - ANCHOR BOLTS QUANTITY
DIA. OF ANCHOR BOLTS NO. OF ANCHOR BOLTS BOLT LENGTH [mm]
M16 8 440
125
ANCHOR BOLTS TO BE INSTALLED
BEFORE CASTING OF FOUNDATION MK9-2Ø10@200
MK8-2Ø10@200
75(TYP.)
PRICE CODE
100.250 TOC 4 FOR PAVING R/F DETAIL 4 LIMITED SECTION EXCAVATION ABA02AC01/02/03
MK7
- 50(TYP.)
-
REF.RELEVANT PAVING DWG. (TYP.)
250
REFERENCE DRAWINGS
EQUIPMENT LAYOUT AMMONIA PROCESS AND UTILITIES PLANT, NITROGEN PLANT,
4124-XX-DE-217100001-IS03 DEMI WATER STORAGE & POLISHER, CENTRAL HEATING AND WINTERIZATION UNIT,
PLAN AT EL. 100.000 AND ABOVE
DETAIL OF ABJ001
(SCALE: 1 : 25) SECTION 4 4124-AA-DA-210000001S00 KEY PLAN PILES AND FOUNDATION LAYOUT PLANT 1 AMMONIA
(SCALE: 1 : 25) - 4124-AA-DX-200000001 CONCRETE WORKS GENERAL NOTES FOR CONCRETE WORKS
SYMMETRICAL
MK7-3Ø16
2 2
= =
= =
250
100
- -
UPDATE
MK9
AB-G 09Г2С-6-2a-M16-120-320
KEYPLAN
SECTION 2
(SCALE: 1 : 25) - BAR BENDING SCHEDULE - REINFORCEMENT TYPE RFJ001
BAR MARK QUANTITY BAR DIAMETER [mm] BAR LENGTH [mm] TOTAL BAR LENGTH [mm] a b c d e g SHAPE TOTAL WEIGHT [Kg]
UP
UP
19350
UP
UP
SECONDARY STRUCTURE
100.250 TOC 1710-SS002I
UP
UP
CABLETRAY
L
MK4 2 16 2435 4870 0 2435 0 0 0 0 7.69 DS DS
UP
DN
DS DS DS
LUBEOI L
L
UP
UP
43 87475 126.07
REINFORCEMENT QUANTITY
BAR DIAMETER [mm] UNIT WEIGHT [Kg/m] TOTAL BAR LENGTH [mm] TOTAL WEIGHT [Kg]
10 0.62 17190 10.66 Isometric View 01 ISSUED FOR CONSTRUCTION 21-Oct-2021 S.Parulekar
P.Nair/
D.Pushkar
G.Girardi
16 1.58 74830 118.23 REV DATA PREPARED CHECKED APPROVED
DESCRIPTION -ОПИСАНИЕ
РЕД. ДАТА ПОДГОТОВИЛ ПРОВЕРИЛ УТВЕРДИЛ
92020 128.89
Tecnimont
This copy of this document is LLC Eurochem Northwest-2's property and its copyright is vested in Tecnimont Spa. This document contains confidential information and cannot be copied to or used
by any party for any purpose without Tecnimont’s Spa and LLC Eurochem Northwest-2’s prior written consent. Additional restrictions are as stated in the above confidentiality and export label, if any.
Настоящая копия документа является собственностью OOО "ЕвроХим-Северо-Запад-2”, и авторские права на него закреплены за АО «Текнимонт». Данный документ содержит
конфиденциальную информацию и не может копироваться или использоваться никакой другой стороной ни для каких целей без предварительного письменного согласия АО
«Текнимонт» и OOО "ЕвроХим-Северо-Запад-2”. Возможные дополнительные ограничения указаны выше в метке конфиденциальности.
- - - - - - OWNER:
ВЛАДЕЛЕЦ: LLC EUROCHEM NORTHWEST - 2
A0 SHEET
F/W & R/F DETAIL OF FOUNDATION
FOR SECONDARY STRUCTURE 1130-SS002I 1:100