CERTIFICATE

Issued to:
Applicant: Licensee:
WAGO Kontakttechnik GmbH & Co. KG WAGO Kontakttechnik GmbH & Co. KG
Hansastraße 27 Hansastraße 27
32423 Minden/westfalen, Germany 32423 Minden/westfalen, Germany

Product : 1 – 3 pole(s) PCB terminal block for LED module


Trade name(s) : WAGO
Type(s)/model(s) : 2059-090..., 2059-301..., 2059-302..., 2059-303..., 2059-321..., 2059-322... and
2059-323...

The product and any acceptable variation thereto is specified in the Annex to this certificate and the
documents therein referred to.

DEKRA hereby declares that the above-mentioned product has been certified on the basis of:
- a type test according to the standard EN 60838-2-2:2006, EN 60838-2-2:2006/A1:2012,
EN 60838-1:2017 and EN 60838-1:2017/A1:2017
- an inspection of the production location according to CENELEC Operational Document CIG 021
- a certification agreement with the number 900220

DEKRA hereby grants the right to use the KEMA-KEUR certification mark.

The KEMA-KEUR certification mark may be applied to the product as specified in this certificate for the
duration of the KEMA-KEUR certification agreement and under the conditions of the KEMA-KEUR
certification agreement.

This certificate is issued on 4 December 2018 and expires upon withdrawal of one of the above mentioned
standards.

Certificate number: 71-106226

DEKRA Certification B.V.

j
B.T.M. Holtus
<
H.R.M. Barends
Managing Director Certification Manager

© Integral publication of this certificate is allowed

ACCREDITED BY THE
DUTCH ACCREDITATION
COUNCIL

DEKRA Certification B.V. Meander 1051, 6825 MJ Arnhem P.O. Box 5185, 6802 ED Arnhem, The Netherlands
T +31 88 96 83000 F +31 88 96 83100 www.dekra-certification.com Company registration 09085396
ANNEX TO KEMA-KEUR CERTIFICATE 71-106226 page 1 of 2

SPECIFICATION OF THE CERTIFIED PRODUCT

Product data
Product : 1 – 3 pole(s) PCB terminal block for LED module
Trade name(s) : WAGO
Type(s)/model(s) : 2059-090..., 2059-301..., 2059-302..., 2059-303..., 2059-321...,
2059-322... and 2059-323...
Rated current : 3A
Nature of supply : ac
Connecting capacity : 0,14...0,5 mm²
Temperature range : -60...+105 °C
Material : thermoplastic material
Description : terminal for SMD technology

Product data – type 2059-090...


Description : interconnection bridge with a pin length of 15,3 mm
last digits in type designation correspond with pole number 1-6
additional suffix number /0018-0000 for pin length 17,5 mm
additional suffix number /0021-0000 for pin length 20,5 mm
additional suffix number /xxxx-xxx4 for black variants

Product data – type 2059-301... and 2059-321...


Rated voltage : 250 V (overvoltage category III, pollution degree 3)
320 V (overvoltage category III, pollution degree 2)
630 V (overvoltage category II, pollution degree 2)
Rated impulse withstand voltage : 4 kV
Number of poles : 1
Description : provided with 1 screwless type clamping unit per pole
last digits in type designation correspond with pole number 1-3
additional suffix /0998-0403 for tape and reel packaging
Color : white for 2059-301
black for 2059-321

Product data – type 2059-302... and 2059-322...


Rated voltage : 37 V (overvoltage category III, pollution degree 2)
Rated impulse withstand voltage : 800 V
Number of poles : 2
Description : provided with 1 screwless type clamping unit per pole
last digits in type designation correspond with pole number 1-3
additional suffix /0998-0403 for tape and reel packaging
Color : white for 2059-302
black for 2059-322

Product data – type 2059-303... and 2059-323...


Rated voltage : 37 V (overvoltage category III, pollution degree 2)
Rated impulse withstand voltage : 800 V
Number of poles : 3
Description : provided with 1 screwless type clamping unit per pole
last digits in type designation correspond with pole number 1-3
additional suffix /0998-0403 for tape and reel packaging
Color : white for 2059-303
black for 2059-323

DEKRA Certification B.V. Meander 1051, 6825 MJ Arnhem P.O. Box 5185, 6802 ED Arnhem, The Netherlands
T +31 88 96 83000 F +31 88 96 83100 www.dekra-certification.com Company registration 09085396
ANNEX TO KEMA-KEUR CERTIFICATE 71-106226 page 2 of 2

TESTS

Test requirements
EN 60838-2-2:2006
EN 60838-2-2:2006/A1:2012
EN 60838-1:2017
EN 60838-1:2017/A1:2017

Test result
The test results are laid down in DEKRA test file 222945200.

Additional information
Item numbers may be denoted with or without leading zeros.
e.g. 2059-301/998-403 or 2059-0301/0998-0403.

Conclusion
The examination proved that all requirements were met.

Factory locations
Wago Elwag
Innowacyjna 2
55-330 Wroblowice, Poland

Wago Elwag sp.z.o.o.


ul. Piekna 58 a
50-506 Wroclaw, Poland

Wago Pvt. Ltd.


C-27, Sector-58, Phase III
201301 Noida Uttar Pradesh, India

Wago Electronic (Tianjin) Co. Ltd.


No. 5 Quanhui Road
Wu Qing Development Area
301700 Tianjin, China

WAGO Kontakttechnik GmbH & Co. KG


Hansastraße 27
32423 Minden/westfalen, Germany

WAGO Kontakttechnik GmbH &Co. KG Werk Sondershausen


Waldstraße 1
99706 Sondershausen, Germany

WAGO Contact S.A.


Route de l'Industrie 19
CP 168
1564 Domdidier, Switzerland

DEKRA Certification B.V. Meander 1051, 6825 MJ Arnhem P.O. Box 5185, 6802 ED Arnhem, The Netherlands
T +31 88 96 83000 F +31 88 96 83100 www.dekra-certification.com Company registration 09085396
Responsible CB:

OD ECS 040-1
ed. May 2013

TEST REPORT SUMMARY


Report Reference No. ................... : 2229452.50

E
Date of issue................................... : 2019-01-08
Tested by (name + signature).......... : A.P. van der Veen
Witnessed by (name + signature).... : -
Approved by (name + signature) ..... :
Supervised by (name + signature)... :
Testing Laboratory........................ :
T. Drost
- H
DEKRA Certification B.V.
Address .......................................... : Meander 1051, 6825 MJ Arnhem, The Netherlands
Testing procedure ........................... : CCA-TL IECEE-CBTL TMP WMT SMT
Testing location ............................ : DEKRA Certification B.V.
Address .......................................... : Meander 1051, 6825 MJ Arnhem, The Netherlands
Applicant ....................................... : Wago-Kontakttechnik GmbH & Co. KG
Address .......................................... : Hansastrasse 27, 32423 Minden/Westfalen, Germany
Manufacturer ................................. : Wago-Kontakttechnik GmbH & Co. KG
Address .......................................... : Hansastrasse 27, 32423 Minden/Westfalen, Germany
Product.......................................... : 1 - 3 pole(s) PCB terminal block for LED module
Model/Type reference ..................... : 2059-090…; 2059-301…; 2059-302…; 2059-303…
2059-321…; 2059-322…; 2059-323…
Trademark ...................................... : WAGO
Ratings ........................................... : for 1 pole: 250 V~; 3 A; PD3; OVC III (4 kV)
320 V~; 3 A; PD2; OVC III (4 kV)
630 V~; 3 A; PD2; OVC II (4 kV)
for 2 and 3 poles: 37 V~; 3 A; PD2; OVC III (800 V)

Certification Scheme....................... : ENEC CCA Other: ________


EN 60838-2-2:2006+A1:2012 and
Standard(s).................................... :
EN 60838-1:2017+A1:2017
The text of the a.m. European Standard was approved by CENELEC under the Unique Acceptance
Procedure and is identical with the corresponding IEC Publication.
The text of the a.m. European Standard was approved by CENELEC with agreed common
modifications and is not identical with the corresponding IEC Publication.

This EN test report consists of the following parts:


IEC TRF No.: IEC60838_2_2C Report Reference No........................: 2229452.50
CENELEC-Addendum Form No. Report Reference No. or Annex No...:
__________________ .................... :

Copyright © 2013 EEPCA, Paris, France. All rights reserved.


This ECS document together with the test report is only valid if signed by an approved ENEC or CCA Testing
Laboratory and accompanied by the associated ENEC Licence or CCA Notification of Test Results, issued by
a Certification Body member of ECS.

doc20190118155918273.doc page 1 of 1
Test Report issued under the responsibility of:

TEST REPORT
IEC 60838-2-2
Miscellaneous lampholders
Part 2-2: Particular requirements:
Connectors for LED-modules
Report Number. ............................ : 2229452.50
Date of issue ................................. : 2018-11-21
Total number of pages .................. 21 pages

Name of Testing Laboratory


preparing the Report .................... : DEKRA Certification B.V.
Applicant’s name.......................... : Wago-Kontakttechnik GmbH & Co. KG
Address......................................... : Hansastrasse 27, 32423 Minden/Westfalen, Germany
Test specification:
Standard........................................ : IEC 60838-2-2: 2006 (First Edition) + A1:2012
Test procedure.............................. : type test
Non-standard test method............ : N/A
Test Report Form No. ................... : IEC60838_2_2C
Test Report Form(s) Originator.... : VDE Testing and Certification Institute
Master TRF.................................... : Dated 2015-12
Copyright © 2015 IEC System of Conformity Assessment Schemes for Electrotechnical
Equipment and Components (IECEE System). All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting
from the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the
CB Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory
and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing
Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,
responsible for this Test Report.
Page 2 of 21 Report No. 2229452.50

Test item description...................... : 1 – 3 pole(s) PCB terminal block for LED module
Trade Mark ...................................... : WAGO
Manufacturer................................... : Wago-Kontakttechnik GmbH & Co. KG
Hansastrasse 27, 32423 Minden/Westfalen, Germany
Model/Type reference..................... : 2059 series
Ratings............................................ : for 1 pole:
250 V~; 3 A; PD3; OVC III (4 kV)
320 V~; 3 A; PD2; OVC III (4 kV)
630 V~; 3 A; PD2; OVC II (4 kV)
for 2 and 3 poles:
37 V~; 3 A; PD2; OVC III (800 V)

Responsible Testing Laboratory (as applicable), testing procedure and testing location(s):

CB Testing Laboratory: DEKRA Certification B.V.


Testing location/ address............................: Meander 1051, 6825 MJ Arnhem, The Netherlands
Associated CB Testing Laboratory:
Testing location/ address............................:
Tested by (name, function, signature)........: A.P. van der Veen

E
H
Approved by (name, function, signature)...: T. Drost

Testing procedure: CTF Stage 1:


Testing location/ address............................:
Tested by (name, function, signature)........:
Approved by (name, function, signature)...:

Testing procedure: CTF Stage 2:


Testing location/ address............................:
Tested by (name + signature) .....................:
Witnessed by (name, function, signature)..:
Approved by (name, function, signature)...:

Testing procedure: CTF Stage 3:


Testing procedure: CTF Stage 4:
Testing location/ address............................:
Tested by (name, function, signature)........:
Witnessed by (name, function, signature)..:
Approved by (name, function, signature)...:
Supervised by (name, function, signature) :

TRF No. IEC60838_2_2C


Page 3 of 21 Report No. 2229452.50

List of Attachments (including a total number of pages in each attachment):


N/A

Summary of testing:

Tests performed (name of test and test Testing location:


clause):
full type testing acc, the IEC 60838-2-2:2006 + DEKRA Certification B.V.
A1:2012; in conjunction with IEC 60838:2016 +
A1:2017. Meander 1051, 6825 MJ Arnhem, The Netherlands
This report is based on the test report 2220297.50
which covers the requirements according to EN
60947-7-4:2013.

Summary of compliance with National Differences (List of countries addressed):

The product fulfils the requirements of


EN 60838-2-2:2006+A1:2012
EN 60838-1:2017+A1:2017

Copy of marking plate:


The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective NCBs that own these marks.

WAGO
2059

TRF No. IEC60838_2_2C


Page 4 of 21 Report No. 2229452.50

Test item particulars ..............................................: 1 – 3 pole(s) PCB terminal block


Type of connectors for LED-modules.......................: unenclosed enclosed
Rated operating temperature ...................................: ≤ 80°C
T-marked connectors for LED-modules > 80°C .........: -60…+105 °C
...............................................................................: -
Possible test case verdicts:
- test case does not apply to the test object.......... : N/A
- test object does meet the requirement................ : P (Pass)
- test object does not meet the requirement.......... : F (Fail)
Testing ................................................................... : -
Date of receipt of test item..................................... : 2018-07-02
Date (s) of performance of tests ............................ : 2018-07-02 to 2018-10-31

General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.

Throughout this report a comma is used as the decimal separator.


List of test equipment must be kept on file and available for review.
Clause numbers between brackets refer to clauses in IEC 60598-1.
Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate Yes
includes more than one factory location and a Not applicable
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided...........................................................:

When differences exist; they shall be identified in the General product information section.

TRF No. IEC60838_2_2C


Page 5 of 21 Report No. 2229452.50
Name and address of factory (ies)........................ : Wago Elwag
Innowacyjna 2
55-330 Wroblowice, Poland

Wago Elwag sp.z.o.o.


ul. Piekna 58 a
50-506 Wroclaw, Poland

Wago Pvt. Ltd.


C-27, Sector-58, Phase III
201301 Noida Uttar Pradesh, India

Wago Electronic (Tianjin) Co., Ltd.


No.5 Quanhui Road
We Qing Development Area
301700 Tianjin, China

WAGO-Kontakttechnik GmbH & Co. KG


Hansastraße 27,
32423 Minden/Westfalen, Germany

WAGO Kontakttechnik GmbH & Co. KG Werk


Sondershausen
Waldstraße 1
99706 Sondershausen, Germany

WAGO Contact S.A.


Route de I’Industrie 19
CP 168
1564 Domdidier, Switzerland

TRF No. IEC60838_2_2C


Page 6 of 21 Report No. 2229452.50

General product information:


PCB terminal block, surface mount, with screwless terminal for copper conductors
2059-30x with white body
2059-32x with black body
Type 2059-301; 2059-321 (1 pole) Type 2059-302; 2059-322 (2 poles) and
2059-303; 2059-323 (3 poles)
Overvoltage III III II III
category
(OVT)
Pollution 3 2 2 2
degree (PD)
Rated 250 V 320 V 630 V 37 V
voltage
Rated 4 kV 800 V
impulse
withstand
voltage
Nominal 3A 3A
current
Connecting 0,14…0,5 mm2 solid
capacity

2059-090: interconnection bridge with a pin length of 15,3 mm. Last digits in type designation correspond
with pole number 1-6. Additional suffix number /0018-0000 for pin length 17,5 mm. Additional suffix
number /0021-0000 for pin length 20,5 mm.

Ratings are outside the scope of IEC 60838-2-2 therefore also the IEC 60598-1 cl.15 was taken into
account to cover the higher ratings.

TRF No. IEC60838_2_2C


Page 7 of 21 Report No. 2229452.50

IEC 60838-2-2
Clause Requirement + Test Result - Remark Verdict

3 GENERAL REQUIREMENTS P
Connectors for LED-modules shall be so designed P
and constructed that in normal use they function
reliably and cause no danger to persons or
surroundings
Compliance is checked by the tests specified: P

4 GENERAL CONDITIONS FOR TESTS P


4.1 Tests according to this standard and type tests P
The tests of 16.1, 16.2 and 19 are carried out on P
three additional specimens for each test
4.2 Tests are made at an ambient temperature of 20° C P
± 5° C, unless otherwise specified, and with the
holder in the most unfavourable position for normal
use

5 STANDARD RATINGS P
5.1 Maximum rated voltage is 50 V a.c. see general product P
information for details
5.2 Rated current between 10 mA and 3 A 3A P
5.3 The rated operating temperature range is -30°C to -60…+105 °C P
+65°C
Indoor use is exempt from lower limit N/A
For relevant application notice and symbol see IEC N/A
60598-1.

6 CLASSIFICATION P
Unenclosed connectors for LED-modules P
Enclosed connectors for LED-modules N/A
Partly reinforced insulated connectors for LED- N/A
modules
Reinforced insulated connectors for LED-modules N/A
Non-polarized connector for LED-modules P
Polarized connector for LED-modules N/A

7 MARKING P
7.1 Connectors for LED-modules marked with: P
a) mark of origin P
b) unique catalogue number or identifying P
reference

TRF No. IEC60838_2_2C


Page 8 of 21 Report No. 2229452.50

IEC 60838-2-2
Clause Requirement + Test Result - Remark Verdict

7.2 The following information given on the connectors for LED-modules or available in P
manufacturer’s catalogue:
a) the rated voltage and the rated pulse voltage, if P
applicable
For polarized connectors: the rated voltage and the N/A
pair of rated pulse voltage
b) the rated current in amperes P
c) the rated operating temperature “T”, if greater -60…+105 °C P
than 65° C, in steps of 10° C
d) the conductor sizes for which the terminals are 0,14…0,5 mm2 P
designed
e) the high voltage arrow close to the relevant N/A
terminal for polarized lampholders, if applicable
Required symbol used: P
– for voltage P
– for current P
– for wattage N/A
For connectors for LED-modules in equipment P
where a higher degree of availability is expected,
distances for impulse withstand category III may be
applicable. This information has to be indicated in
the manufacturer’s catalogue or the like
Enclosed reinforced insulated connectors offer an N/A
adequate level of protection for use in luminaries
where they are accessible in normal use. This in-
formation shall be indicated in the manufacturer’s
catalogue or the like.
For parity reinforced insulated connectors, suffi-cient N/A
creepage distances and clearances to outer
accessible surfaces will require additional protec-
tion to some parts of the connector by the luminaire
design or by use of additional attachment(s) or
cover(s). This information has to be indicated in the
manufacturer’s catalogue or the like
The instructions supplied contain the information P
required to ensure correct mounting and operation
of the connectors for LED-modules
The marking according to 7.1 and 7.2 durable and legible: P
– after test with water, 15 s P
– after test with petroleum spirit, 15 s P

TRF No. IEC60838_2_2C


Page 9 of 21 Report No. 2229452.50

IEC 60838-2-2
Clause Requirement + Test Result - Remark Verdict

8 PROTECTION AGAINST ELECTRIC SHOCK N/A


8.1 Enclosed connectors for LED-modules are so constructed that, when they are been N/A
built-in or installed and wired as in normal use, their live parts are not accessible:
– without a LED inserted N/A
– with the appropriate LED inserted N/A
– during insertion or removal of the LED N/A
Compliance checked with standard test finger of IEC N/A
60529

9 TERMINALS P
The Connectors for LED-modules provided with: P
– terminals with screw clamping N/A
– screwless terminals of spring or wedge type P
– tabs or pins for push-on connections N/A
– posts for wire wrapping N/A
– soldering lugs N/A
– connecting leads (tails) N/A
Terminal screws and nuts have a metric thread N/A
The screwless terminals satisfactory with both rigid P
conductors and flexible cables or cords
Other means of connection N/A
(Example: a lampholder for extra low voltage halo-
gen lamps providing electrical connection to a metal
part of the luminaire during lampholder assem-bly).
9.2 Terminals with screw clamping comply with the re- see annex 1 N/A
quirements of clause 14 of IEC 60598-1
Screwless terminals of spring or wedge type com- see annex 2 P
ply with the requirements of clause 15 of IEC 60598-
1
Tabs or pins for push-on connections comply with see annex 2 N/A
the requirements of clause 15 of IEC 60598-1
Posts for wire wrapping comply with the require- N/A
ment in IEC 60352-1
Soldering lugs comply with relevant requirements in N/A
IEC 60068-2-20
Connecting leads (tails) comply with the require- N/A
ments of 9.3

TRF No. IEC60838_2_2C


Page 10 of 21 Report No. 2229452.50

IEC 60838-2-2
Clause Requirement + Test Result - Remark Verdict

For T-marked connectors, the terminals are tested P


at the rated operating temperature, unless otherwise
stated by the manufacturer.
The conditions for a reliable installation and P
operation shall be given in the connector
manufacturer’s or responsible vendor' s documents.
Connector contacts providing electrical connection N/A
to a metal part of the luminaire during connector
assembly shall comply with the requirements of IEC
60598-1, Section 15.
9.3 Connecting leads connected by: N/A
– soldering N/A
– welding N/A
– crimping N/A
Insulation of the leads complying with IEC 60227 or N/A
IEC 60245 or subclause 5.3 in IEC 60598-1
Pull test: see clause 16 N/A

10 PROVISION FOR EARTHING N/A


10.1 Connectors for LED-modules with provision for N/A
earthing provided with at least one earthing termi-nal
10.2 Accessible metal parts of Connectors for LED- N/A
modules with earthing terminal are permanently and
reliable connected to the earthing terminal
Accessible metal parts of Connectors for LED- N/A
modules without earthing terminal allow reliable
earthing
Earth continuity between external metal parts un- N/A
less screened from live parts by double or rein-
forced insulation
Test: see 12.2 N/A
10.3 Earthing terminal complies with clause 9 N/A
Clamping means adequately locked against acci- N/A
dental loosening
Screw terminals not possible to loosen by hand N/A
Screwless terminals not possible to loosen N/A
unintentionally by hand
10.4 No risk of corrosion resulting from contact with the N/A
copper conductor
The screw or the body of the earthing terminal made N/A
of brass or other metal no less resistant to corrosion
Contact surfaces are bare metal N/A

TRF No. IEC60838_2_2C


Page 11 of 21 Report No. 2229452.50

IEC 60838-2-2
Clause Requirement + Test Result - Remark Verdict

10.5 Metal parts of cord anchorage, including clamping N/A


screws, insulated from earthing circuit

11 CONSTRUCTION P
11.1 Wood, cotton, silk, paper and similar materials not N/A
allowed as insulation unless suitably impregnated
Lacquer or enamel are not deemed to provide insu- N/A
lation
Minimum cross-sectional area for the connecting N/A
leads is 0.22 mm²
Minimum cross-sectional area for flat cables (rib-bon N/A
cables) is 0,09 mm²
11.2 Connectors for LED-modules dimensions comply N/A
with relevant IEC standard
11.4 Contacts and all other current-carrying parts are so P
constructed as to prevent excessive temperature
rise
Test for 1h with 1,25 times rated current. Tempera- Max. 24 K at 3,75 A P
ture rise does not exceed 45 K
11.5 Connectors designed with a barrel thread for shade N/A
holder rings and shade holder rings shall comply
with IEC 60399 (checked by gauges).

12 MOISTURE RESISTANCE, INSULATION RESISTANCE AND ELECTRIC P


STRENGTH
12.1 Humidity treatment for 48h P
No damage to the connectors for LED-modules P
12.2 The insulation resistance and the electric strength of P
the connectors for LED-modules shall be adequate
12.2.1 Minimum insulation resistance at 500 V d.c P
- between live parts of different polarity P
- between live parts connected together and ex- N/A
ternal metal parts intended to be earthed
- between such live parts and external metal parts, N/A
including fixing screws and metal foil
12.2.2 Electric strength test for 1 min: P
– between live parts of different polarity P
– between live parts connected together and ex- N/A
ternal metal parts intended to be earthed
– between such live parts and external metal parts, N/A
including fixing screws and metal foil

TRF No. IEC60838_2_2C


Page 12 of 21 Report No. 2229452.50

IEC 60838-2-2
Clause Requirement + Test Result - Remark Verdict

For connectors for LED-modules with a rated volt- Only for types 2059-302; P
age up to and including 50 V, the test voltage is 2059-322 (2 poles) and
500 V 2059-303; 2059-323 (3 poles)
Between the contacts of Connectors for LED- N/A
modules, the test voltage is twice the working volt-
age
For all other cases, the test voltage is 2U + 1000 V N/A
For enclosed and unenclosed reinforced insulated N/A
connectors, the test voltage shall be determined
from Table 10.2 of IEC 60598-1.
No flash-over or breakdown occurs P
Test for earth continuity according to 10.2 P

13 MECHANICAL STRENGTH P
Impact test, 4 blows applied by pendulum apparatus according to fig. D.1: P
- ceramic parts (100 mm) N/A
- other materials (150 mm) P
No serious damage P
Creepage distances and clearances not reduced P
below values of clause 15

14 SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS P


Screws, current-carrying parts and mechanical P
connections shall withstand mechanical stress
occurring in normal use
Compliance with 4.11 and 4.12 of IEC 60598-1 P

15 CREEPAGE DISTANCES AND CLEARANCES (SAMPLE 1, 2 AND 3) P


Live parts and adjacent metal parts shall be P
adequately spaced. Creepage distances and
clearances shall be not less than the values shown
in table 2a and 2b
Impulse withstand category II: 2059-301 (1 pole) evaluation in N/A
end application
Sinusoidal voltages N/A
1. between live parts of different polarity: N/A
basic insulation N/A
- insulation with PTI ≥ 600 N/A
- insulation with PTI < 600 N/A
- clearances N/A

TRF No. IEC60838_2_2C


Page 13 of 21 Report No. 2229452.50

IEC 60838-2-2
Clause Requirement + Test Result - Remark Verdict

reinforced insulation N/A


- insulation with PTI ≥ 600 N/A
- insulation with PT < 600 N/A
- clearances N/A
2. between live parts and external metal parts, or the outer surface of parts of in- N/A
sulating material which are permanently fixed to the holder, including screws or
devices for fixing covers or fixing the holder to its support:
basic insulation N/A
- insulation with PTI ≥ 600 N/A
- insulation with PT < 600 N/A
- clearances N/A
reinforced insulation N/A
- insulation with PTI ≥ 600 N/A
- insulation with PT < 600 N/A
- clearances N/A
3. between live parts and the mounting surface or a loose metal cover, if any, if the N/A
construction does not ensure that the values under item 2 are maintained under the
most unfavourable circumstances
- clearances N/A
Impulse withstand category III: 2059-301 (1 pole) evaluation in P
end application (4 kV)
Sinusoidal voltages: P
1. between live parts of different polarity: 2059-302 and 2059-323 (800 V) P
- insulation with PTI ≥ 600 N/A
- insulation with PT < 600 0,9 mm ≥ required 0,9 mm P
- clearances 0,9 mm > required 0,2 mm P
2.between live parts and external metal parts, or the outer surface of parts of in- N/A
sulating material which are permanently fixed to the holder, including screws or
devices for fixing covers or fixing the holder to its support:
- insulation with PTI ≥ 600 N/A
- insulation with PT < 600 N/A
- clearances N/A
3.between live parts and the mounting surface or a loose metal cover, if any, if the N/A
construction does not ensure that the values under item 2 are maintained under the
most unfavourable circumstances:
— clearances N/A
Minimum distances for non-sinusoidal pulse voltages (Table 3) N/A
— rated pulse voltage (peak kV) N/A

TRF No. IEC60838_2_2C


Page 14 of 21 Report No. 2229452.50

IEC 60838-2-2
Clause Requirement + Test Result - Remark Verdict

— clearances N/A
For polarized connectors, creepage distances and N/A
clearances to external metal parts or the outer
surface of parts of insulating material may be
designed and shall be checked for each pole
separately.
Compliance is checked by tests with the rated P
pulse voltage of the holder.
Creepage distances are not less than the required P
minimum clearances

16 ENDURANCE P
Test by means of a commercial lamp cap, 10 cycles. 3,3 A P
The holder placed with a solid steel test cap in a
heating cabinet for 48 h at specified temperature
and loaded with 1,1 times the rated current. Cools
down for 24 h
For connectors for LED-modules which form an N/A
integral part of the luminaire, this temperature is
replaced by that measured according to the
operating conditions given in 12.4.2 of IEC 60598-1,
plus 10 K, with a tolerance of ± 5 °C
At the end of the test, the holder shows: P
- no reduction of protection against electric shock P
- no loosening of electrical contacts P
- no cracks, swelling or shrinking P
- compliance with the gauges of IEC 60061-3 as far N/A
as the exist
The resistance of contacts and connections does P
not exceed 0,045 Ω +(A*n)
Pull test for connecting leads with 20 N for 1 min N/A
according to 8.3
16.1 Connectors for LED-modules shall be capable of P
maintaining good electrical contact to the module
during rapid change of temperature
100 cycles temperature change test P
During the test, the connector for LED-modules shows: P
- no reduction of protection against electric shock P
- no loosening of electrical contacts P
- no cracks, swelling or shrinking P
16.2 Connectors for LED-modules with good electrical P
contact to the module
6 cycles damp heat test P

TRF No. IEC60838_2_2C


Page 15 of 21 Report No. 2229452.50

IEC 60838-2-2
Clause Requirement + Test Result - Remark Verdict

During the test, the connector for LED-modules shows: P


- no reduction of protection against electric shock P
- no loosening of electrical contacts P
- no cracks, swelling or shrinking P
16.3 Resistance of connector contacts P
The resistance of contacts and connections does not exceed 0,045 Ω + (A x n): P
a) before 100 cycles temperature change test max 3,5 mΩ P
a) after 100 cycles temperature change test max 5,3 mΩ P
b) before 6 cycles damp heat test max 2,7 mΩ P
b) after 6 cycles damp heat test max 3,9 mΩ P

17 RESISTANCE TO HEAT AND FIRE P


17.1 External parts of insulating material providing P
protection against electric shock and parts of
insulating material retaining live parts or ELV parts in
position shall be resistant to heat
Ball pressure test at 25 °C ± 5 °C above the P
operating temperature, with a minimum of 125 ° C
for parts retaining live parts in position < 1,0 mm
Diameter of impression not exceeding 2 mm P
17.2 Parts of insulating material retaining live parts in P
position and external parts of insulating material
providing protection against electric shock shall be
resistant to flame and ignition.
17.3 Glow-wire test 650 °C on parts providing protection N/A
against electric shock, including those with a
conductive exterior and parts of insulating material
retaining ELV parts in position
Any flame or glowing extinguished within 30 s, and N/A
any flaming drops do not ignite tissue paper
17.4 Needle flame test 10 s on parts retaining live parts in P
position or ELV lamp contacts in position
Any self sustaining flame extinguished within 30 s, P
and any flaming drops do not ignite tissue paper
17.5 Tracking test on parts retaining live parts or ELV P
parts in position of drip proof Connectors for LED-
modules
Connectors for LED-modules withstands 50 drops P
without failure at PTI 175
17.6 The resistance to heat of insulating material and/or P
outer parts of the connectors for LED-modules is
tested 168 h in a heating cabinet

TRF No. IEC60838_2_2C


Page 16 of 21 Report No. 2229452.50

IEC 60838-2-2
Clause Requirement + Test Result - Remark Verdict

115°C ± 5°C or N/A


(T + 35)°C ± 5°C by T-marked connectors for LED- 140 °C P
modules
This test is not made on connectors for LED- N/A
modules which are integral with the luminaire as a
similar test is already given in IEC 60598-1.
At the end of the test, the connectors for LED-modules shows P
- no reduction of protection against electric shock P
- no loosening of electrical contacts P
- no cracks, swelling or shrinking P
- compliance with the gauges of IEC 60061-3 as far N/A
as they exist
The connectors for LED-modules withstands the P
mechanical strength test in 13, the height of fall
being reduced to 50 mm
The sealing compound does not flow to such an N/A
extent that live parts are exposed

18 RESISTANCE TO EXCESSIVE RESIDUAL STRESSES (SEASON CRACKING) P


AND TO RUSTING
18.1 Contacts and other parts of copper or copper alloy P
do not show any cracks after the 24 h test in a
cabinet with ammonium chloride solution, inspected
at an optical magnification of 8x
18.2 Ferrous parts, the rusting of which may endanger N/A
the safety of the holder, shall be adequately rust-
protected

19 VIBRATIONS P
19.1 Connectors for LED modules shall be capable to P
satisfactorily maintain electrical contact to the
module when affected to vibration in normal use
Vibration test in accordance to IEC 60068-2-6 with 5 P
sweep cycles (10-500 Hz, 5 g, each axis) for 2 h
After vibration test contact making is still present P

20 HEAT MANAGMENT N/A


Information for heat management is provided in N/A
clause 21 and Annex D of IEC 62031 and in the
relevant IEC 60061 data sheets

TRF No. IEC60838_2_2C


Page 17 of 21 Report No. 2229452.50

IEC 60838-2-2
Clause Requirement + Test Result - Remark Verdict

ANNEX 1: screw terminals (IEC 60598-1) N/A


(14) SCREW TERMINALS N/A
(14.2) Type of terminal .................................................... : 
Rated current (A) .................................................. : 
(14.3.2.1) One or more conductors N/A
(14.3.2.2) Special preparation N/A
(14.3.2.3) Terminal size N/A
Cross-sectional area (mm²).................................... : N/A
(14.3.3) Conductor space (mm) .......................................... : N/A
(14.4) Mechanical tests N/A
(14.4.1) Minimum distance N/A
(14.4.2) Cannot slip out N/A
(14.4.3) Special preparation N/A
(14.4.4) Nominal diameter of thread (metric ISO thread) ...... : N/A
External wiring N/A
No soft metal N/A
(14.4.5) Corrosion N/A
(14.4.6) Nominal diameter of thread (mm)........................... : N/A
Torque (Nm).......................................................... : N/A
(14.4.7) Between metal surfaces N/A
Lug terminal N/A
Mantle terminal N/A
Pull test; pull (N) .................................................... : N/A
(14.4.8) Without undue damage N/A

TRF No. IEC60838_2_2C


Page 18 of 21 Report No. 2229452.50

IEC 60838-2-2
Clause Requirement + Test Result - Remark Verdict

ANNEX 2: screwless terminals (IEC 60598-1) P


(15) SCREWLESS TERMINALS P
(15.2) Type of terminal..................................................... : screwless terminals for solid 
conductor
Rated current (A)................................................... : 3 A 
(15.3.1) Material P
(15.3.2) Clamping P
(15.3.3) Stop P
(15.3.4) Unprepared conductors P
(15.3.5) Pressure on insulating material P
(15.3.6) Clear connection method P
(15.3.7) Clamping independently P
(15.3.8) Fixed in position P
(15.3.10) Conductor size 0,14…0,5 mm 2
P
Type of conductor solid P
(15.5.1) Terminals internal wiring P
(15.5.1.1) Pull test spring-type terminals (4 N, 4 samples)….: 2 samples with 0,14 mm2 P
2 samples with 0,5 mm2
(15.5.1.2) Pull test pin or tab terminals (4 N, 4 samples)……: N/A
Insertion force not exceeding 50 N N/A
(15.5.2) Permanent connections: pull-off test (20 N) N/A
(15.6) Electrical tests P
Voltage drop (mV) after 1 h (4 samples)................. : 0,14 mm2: 8,02 mV; 9,06 mV P
2
0,5 mm : 4,03 mV; 3,66 mV
Voltage drop of two inseparable joints N/A
Number of cycles ................................................... : 25 cycles 
Voltage drop (mV) after 10th alt. 25th cycle 2
0,14 mm : 8,93 mV; 9,73 mV P
(4 samples)............................................................ : 0,5 mm2: 5,31 mV; 4,23 mV
Voltage drop (mV) after 50th alt. 100th cycle N/A
(4 samples)............................................................ :
After ageing, voltage drop (mV) after 10th alt. N/A
25th cycle (4 samples) ........................................... :
After ageing, voltage drop (mV) after 50th alt. N/A
100th cycle (4 samples) ......................................... :
(15.7) Terminals external wiring N/A
Terminal size and rating N/A
(15.8.1) Pull test spring-type terminals or welded N/A
connections (4 samples); pull (N) :

TRF No. IEC60838_2_2C


Page 19 of 21 Report No. 2229452.50

IEC 60838-2-2
Clause Requirement + Test Result - Remark Verdict

Pull test pin or tab terminals (4 samples); N/A


pull (N) .................................................................. :

ANNEX 2: screwless terminals (IEC 60598-1) N/A


(15.9) Contact resistance test N/A
Voltage drop (mV) after 1 h N/A
terminal 1 2 3 4

voltage drop (mV) - - - -

Voltage drop of two inseparable joints N/A

Voltage drop after 10th alt. 25th cycle N/A

Max. allowed voltage drop (mV) ............... : 

terminal 1 2 3 4

voltage drop (mV) - - - -

Voltage drop after 50th alt. 100th cycle N/A

Max. allowed voltage drop (mV) ............... : 

terminal 1 2 3 4

voltage drop (mV) - - - -

Continued ageing: voltage drop after 10th alt. 25th cycle N/A

Max. allowed voltage drop (mV) ............... : 

terminal 1 2 3 4

voltage drop (mV) - - - -

Continued ageing: voltage drop after 50th alt. 100th cycle N/A

Max. allowed voltage drop (mV) ............... : 

terminal 1 2 3 4

voltage drop (mV) - - - -

TRF No. IEC60838_2_2C


Page 20 of 21 Report No. 2229452.50

Annex Product Pictures

TRF No. IEC60838_2_2C


Page 21 of 21 Report No. 2229452.50

Annex Product Pictures

TRF No. IEC60838_2_2C

You might also like