Duman Kontrol Sistemlerine ait

Örnekler
VENTS - manufacture of ventilation and air conditioning systems - 11/27/2018-
http://old.ventilation-system.com/cat/smoke-extraction/print/ (Ukraine, 08150,
Boyarka, st 40 years of October, 36)

Duman Kontrol Sistemi Bulunmayan Bir Binada Yangın

Duman Kontrol Sistemine Sahip Bir Binada Yangın


VENTS - manufacture of ventilation and air conditioning systems - 11/27/2018-
http://old.ventilation-system.com/cat/smoke-extraction/print/

Duman Kontrol Sistemi Bulunmayan Bir Binada Yangın Duman Kontrol Sistemine Sahip Bir Binada Yangın

 Grafik “A”, yangının çıktığı mekanda Duman kontrol sisteminin fonksiyonları:


duman kontrol sistemlerinin  Ateşleme kaynağından çıkan dumanın yayılmasını
bulunmadığı durumlarda, dumanın önleme.
hızla kritik hale geldiğini açıkça  Tahliye yollarına duman transferinin önlenmesi
göstermektedir. (binadan tahliye edilen insanlar için kabul
 Grafik "B" çizelgesi ise, bir duman edilebilir koşulların sürdürülmesi).
kontrol sisteminin, ortamdaki duman  Yangınla mücadele ekiplerinin normal çalışmasını
içeriğini önemli ölçüde azaltarak tüm sağlamak için alevin kaynağı boyunca
yangın süresi boyunca güvenlik eşiğinin mikroklimanın korunması.
altında kalmasına yardımcı olduğunu  Binadaki insanların hayatını korumak.
göstermektedir.  Varlıkların hasara karşı korunması.
VENTS - manufacture of ventilation and air conditioning systems - 11/27/2018-
http://old.ventilation-system.com/cat/smoke-extraction/print/

A smoke control systems consist of:

Ventilation air ducts


(Havalandırma Kanalları) and
shafts (Şaftlar) are intended
for transferring smoke fumes
from the protected premises
Fire-resisting dampers away from the building. Air
(Yangına dirençli damperler) ducts are made of non-
Smoke exhaust fans (Duman Smoke dampers (Duman are installed in exhaust combustible materials.
atım fanları) which are used in damperleri) installed on the ventilation and general
emergency exhaust ventilation protected premises accept ventilation systems to
systems for forced extraction smoke fumes and channel prevent the spread of fire
of smoke and heated gases them into smoke shafts. Such hazards (fire and smoke
and simultaneous transfer of devices are equipped with fumes). Such units are
heat generated by the fire electromagnetic or electric equipped with an electric
away and beyond the limits of actuators. The dampers are actuator or a thermal lock.
the serviced spaces where the rated according to the fire- Pressurization fans
ignition occurs. Such units are resistance limit which can (Basınçlandırma fanları) are
used in production, public, vary up to 180 minutes at the intended for creating a
residential, administrative and smoke temperature of 600 positive pressure differential
other spaces. Such fans are °С. in lift shafts, at landings and
capable of handling smoke in airlock corridors to prevent
and air mixtures with their contamination by
temperatures up to 600 °С. smoke.
VENTS - manufacture of
ventilation and air
conditioning systems -
11/27/2018-
http://old.ventilation-
system.com/cat/typical-
smoke-control-system-
solution/print/

Typical Smoke Control


System Solution
Havalandırma sistemi:
Yangına dayanıklı
damperler (KP)[3 ve 4]
2.Katı bloke eder (kapalı),
[İlk tutuşmanın olduğu alev
ve duman içeren kat]
Yangına dayanıklı
damperler KP [2 ve 6] hala
açıktırla ve havalandırma
sistemi tarafından bitişik 1
ve 3. katların
basınçlandırılmasını
mümkün kılar
Bu arada yangına dayanıklı
damperler KP [1 ve 5] egzoz
havalandırma kollarında
kapalı durmdadırlar.

Duman kontrol sistemi:


Duman tahliyesi VKDV
(VKDH) fanı tarafından açık
KPDU damper (11)
üzerinden yapılır, besleme
havası hava basınçlandırma
sisteminden amortisörler
sırasında açık damper (8)
üzerinden beslenir ve (7,9,
10, 12)kapalı kalır.