La Joya

-16.488765°,-071.784668°
La Joya, Arequipa, Peru
Time zone: UTC-05, America/Lima [PET]

 Report generated: 21 Nov 2022

SITE INFO

Map data Per year Map

Direct normal irradiation DNI 2622.0 kWh/m 2

Global horizontal
GHI 2484.5 kWh/m 2
irradiation

Diffuse horizontal
DIF 654.1 kWh/m 2
irradiation

Global tilted irradiation at


GTI opta 2610.3 kWh/m 2
optimum angle

Optimum tilt of PV modules OPTA 20 /  0 °

Air temperature TEMP 19.0 °C

Terrain elevation ELE 1760 m


500 m
3000 ft Leaflet | Satellite tiles © Esri

Horizon and sunpath


PVOUT map

300 km
200 mi Leaflet | PVOUT map © 2022 Solargis

© 2022 The World Bank Group La Joya 1/4


PV ELECTRICITY AND SOLAR RADIATION

PV system con guration



Pv system: Small residential
Azimuth of PV panels: Default (0º)
Tilt of PV panels: 20º
Installed capacity: 1 kWp

Annual averages Average hourly pro les


Total photovoltaic power output and Global tilted irradiation Total photovoltaic power output [Wh]

1.952 2584.1
Jan Feb Mar Apr
1000 1000 1000 1000

MWh per year kWh/m2 per year 500 500 500 500

0 0 0 0
0 12 24 0 12 24 0 12 24 0 12 24
Monthly averages
Total photovoltaic power output May Jun Jul Aug
1000 1000 1000 1000
200
500 500 500 500

150
0 0 0 0
0 12 24 0 12 24 0 12 24 0 12 24
[kWh]

100 Sep Oct Nov Dec


1000 1000 1000 1000

50
500 500 500 500

0 0 0 0 0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
0 12 24 0 12 24 0 12 24 0 12 24

UTC-05

Average hourly pro les


Total photovoltaic power output [Wh]

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
0-1
1-2
2-3
3-4
4-5
5-6 4 0 1 9 14 11
6-7 71 50 48 21 15 10 9 18 71 141 140 108
7-8 249 226 254 282 246 176 170 242 338 374 365 306
8-9 436 417 464 486 485 460 450 484 536 564 552 491
9 - 10 582 564 622 637 626 606 594 635 676 699 680 626
10 - 11 673 655 723 731 713 696 691 733 766 777 758 709
11 - 12 707 684 749 771 750 735 734 776 799 802 784 740
12 - 13 660 635 706 748 729 720 722 764 780 770 750 706
13 - 14 554 522 612 673 664 652 663 702 706 688 668 619
14 - 15 432 404 485 543 545 536 554 586 577 552 536 487
15 - 16 296 275 331 373 373 369 392 417 400 368 356 327
16 - 17 162 152 172 175 146 118 164 202 186 157 155 160
17 - 18 49 48 36 15 1 3 17 19 16 22 38
18 - 19 0 0
19 - 20
20 - 21
21 - 22
22 - 23
23 - 24
Sum 4,877 4,632 5,201 5,456 5,295 5,078 5,146 5,575 5,856 5,917 5,781 5,328

© 2022 The World Bank Group La Joya 2/4


PV ELECTRICITY AND SOLAR RADIATION

Annual averages Average hourly pro les


Direct normal irradiation Direct normal irradiation [Wh/m2]

2601.7
Jan Feb Mar Apr
1000 1000 1000 1000

kWh/m2 per year 500 500 500 500

0 0 0 0
0 12 24 0 12 24 0 12 24 0 12 24
Monthly averages
Direct normal irradiation May Jun Jul Aug
1000 1000 1000 1000
300
500 500 500 500

0 0 0 0
[kWh/m 2]

200 0 12 24 0 12 24 0 12 24 0 12 24

Sep Oct Nov Dec


1000 1000 1000 1000
100

500 500 500 500

0 0 0 0 0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
0 12 24 0 12 24 0 12 24 0 12 24

UTC-05

Average hourly pro les


Direct normal irradiation [Wh/m2]

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
0-1
1-2
2-3
3-4
4-5
5-6
6-7 199 78 87 132 415 452 382
7-8 522 418 465 529 456 300 287 446 643 703 736 652
8-9 658 560 628 675 723 702 678 713 764 811 840 770
9 - 10 745 646 728 768 802 789 761 795 835 878 899 845
10 - 11 785 681 779 817 846 835 812 845 876 912 929 879
11 - 12 780 669 757 834 863 855 834 867 889 921 940 886
12 - 13 707 582 685 810 851 845 827 863 881 903 914 831
13 - 14 585 462 590 756 818 806 799 830 846 857 870 749
14 - 15 482 369 489 664 755 742 740 770 774 779 793 638
15 - 16 389 285 384 555 650 637 642 672 674 664 672 525
16 - 17 307 207 283 407 364 251 363 493 505 506 519 405
17 - 18 207 138 126 58 69 124 156 216 243
18 - 19 12 7 10
19 - 20
20 - 21
21 - 22
22 - 23
23 - 24
Sum 6378 5103 6002 6874 7128 6764 6742 7363 7944 8504 8781 7814

© 2022 The World Bank Group La Joya 3/4


GLOSSARY

Acronym Full name Unit Type of use


DIF Diffuse horizontal irradiation kWh/m², MJ/m² Average yearly, monthly or daily sum of diffuse horizontal irradiation (©
2021 Solargis)
DNI Direct normal irradiation kWh/m², MJ/m² Average yearly, monthly or daily sum of direct normal irradiation (© 2021
Solargis)
ELE Terrain elevation m, ft Elevation of terrain surface above/below sea level, processed and
integrated from SRTM-3 data and related data products (SRTM v4.1 ©
2004 - 2021, CGIAR-CSI)
GHI Global horizontal irradiation kWh/m², MJ/m² Average annual, monthly or daily sum of global horizontal irradiation (©
2021 Solargis)
GTI Global tilted irradiation kWh/m², MJ/m² Average annual, monthly or daily sum of global tilted irradiation (© 2021
Solargis)
GTI_opta Global tilted irradiation at optimum angle kWh/m², MJ/m² Average annual, monthly or daily sum of global tilted irradiation for PV
modules x-mounted at optimum angle (© 2021 Solargis)
OPTA Optimum tilt of PV modules ° Optimum tilt of x-mounted PV modules facing towards Equator set for
maximizing GTI input (© 2021 Solargis)
PVOUT_total Total photovoltaic power output kWh, MWh, GWh Yearly and monthly average values of photovoltaic electricity (AC)
delivered by the total installed capacity of a PV system (© 2021 Solargis)
PVOUT_speci c Speci c photovoltaic power output kWh/kWp Yearly and monthly average values of photovoltaic electricity (AC)
delivered by a PV system and normalized to 1 kWp of installed capacity
(© 2021 Solargis)
TEMP Air temperature °C, °F Average yearly, monthly and daily air temperature at 2 m above ground.
Calculated from outputs of ERA5 model (© 2021 ECMWF, post-processed
by Solargis)

ABOUT

This pdf report (the “Work”) is automatically generated from the Global Solar Atlas online app (https://globalsolaratlas.info/), prepared by
Solargis under contract to The World Bank, based on a solar resource database that Solargis owns and maintains. It provides the estimated
solar resource, air temperature data and potential solar power output for the selected location and input parameters of a photovoltaic (PV)
power system.

Copyright © 2021 The World Bank


1818 H Street NW, Washington DC 20433, USA

The World Bank, comprising the International Bank for Reconstruction and Development (IBRD) and the International Development
Association (IDA), is the commissioning agent and copyright holder for this Work, acting on behalf of The World Bank Group. The Work is
licensed by The World Bank under a Creative Commons Attribution license (CC BY 4.0 IGO) with a mandatory and binding addition (please
refer to the GSA website for full terms and conditions of use https://globalsolaratlas.info/support/terms-of-use).

The World Bank Group disclaims all warranties of any kind related to the provision of the Work.

The Work is made available solely for general information purposes. Neither the World Bank, Solargis nor any of its partners and a liates
hold the responsibility for the accuracy and/or completeness of the data and shall not be liable for any errors, or omissions. It is strongly
advised that the Work be limited to use in informing policy discussions on the subject, and/or in creating services that better educate relevant
persons on the viability of solar development in areas of interest. As such, neither the World Bank nor any of its partners on the Global Solar
Atlas project will be liable for any damages relating to the use of the Work for nancial commitments or any similar use cases. Solargis has
done its utmost to make an assessment of solar climate conditions based on the best available data, software, and knowledge.

Sources: Solar database and PV software © 2021 Solargis

© 2022 The World Bank Group La Joya 4/4