006Q-P02-1591 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

NO. REVISIONS DATE REVISED CHECKED

A WE ADDED THE REFERENCE DRAWING NUMBER 15-OCT,'83

A B WE REVISED VARIOUS POINTS AS SHOWN

ON REVISION MARKS
10-APR,'84
A

B 15-IA-3-309-B.02

3/IA-V-309
B
15A

25A 25-IA-3-361-B.02
1 - 6002 J - 7 TO MAIN VALVE HEADER
3/IA-V-305
25-IA-3-306-B.02
25A
1 - 6002 J - 7 TO OIL PURIFIER

INSTRUMENT AIR HEADER


3/IA-V-306
25-IA-3-307-B.02

C 25A

3/IA-V-307
1 - 6002 J - 7 TO CONDENSATE POLISHER C
40-IA-3-302-B.02
40A
1 - 6002 J - 7 TO TURBINE LOCAL CONTROL
3/IA-V-302
25A 25-IA-3-351-B.02
1 - 6002 J - 7 TO TURBINE EXTRACTION
3/IA-V-303 CHECK VALVE
25A 25-IA-3-362-B.02
D 3/IA-V-304
1 - 6002 J - 7 TO TURBINE GENERATOR
NOTES
D
15A (1) THIS DIAGRAM IS PREPARED ACCORDING TO "PREPARATION
3-PSL 3-PAL
1999 1999 A PROCEDURES FOR FLOW DIAGRAMS" REF. NO. 001W - XLG
3/IA-V-308
(2) FOR EXPLANATION OF SYMBOLS REFER TO "PIPING AND
3/IA-V-301

3-PAL INSTRUMENT SYMBOLS" REF. NO. 001W - XLG - 001.

4/IA-V-301
2/IA-V-301

5/IA-V-301

6/IA-V-301
1/IA-V-301

1999 (3) FOR VALVE, PIPEWORK AND EQUIPMENT NUMBERING SYSTEM


B
50A

700KPa
REFER TO THE FOLLOWING DOCUMENTS.

E 50-IA-3-301-B.02
100A
0/IA-V
-238
- VALVE
- LINE
: 001S - XLG - 026
: LG - ES - 018
E
- EQUIPMENT : LG - ES - 017
0/IA-V-204 0/IA-V-202 100-IA-O-213-B.02 0/IA-V-206 0/IA-V-208 0/IA-V-210

213-B.02
100-IA-O-

15A
213-B.02

100-1A-0-
15-IA-O-
HTC

214-B.02 100A
REFERENCES
0/IA-V-203 0/IA-V-201 100-IA-O-213-B.02 0/IA-V-205 0/IA-V-207 0/IA-V-209 0/IA-V-237
0/IA-V-211

4/IA-V-401
2/IA-V-401

3/IA-V-401

5/IA-V-401

6/IA-V-401
1/IA-V-401

F F
HTC
0/IA-V-234

1. 006Q - P02 - 158 P&ID OF INSTRUMENT AND SERVIS AIR SYSTEM


50A

B
15A

700KPa 2. 006Q - P02 - 162 P&ID OF YARD SERVICE SYSTEM


TP-151

15-1A-10-215-B.02
3-PAL 3. 001W - XLG - 001 PIPING AND INSTRUMENTATION SYMBOLS
BYG

150-IA-0-209-B.02
1997
BYG

B
B 15A
3-PSI 3-PSI

HTC
1997 1997

15A
3/IA-V-406 A
INSTRUMENT AIR HEADER

40A 40-IA-3-485-B.02

G 1 - 6003 I - 2 TO BURNER
G

150A
3/IA-V-403

0/IA-V-212
15-AI-10-001-006 TP-153
40A 40-IA-3-402-B.02
1 - 6003 I - 2 TO BOILER LOCAL CONTROL

15A

BYG
3/IA-V-402
25-IA-3-404-B.02
25A
TO NG UNIT (UNIT NO.3)

TO.AIR CONDITIONER
1 - 6003 I - 2

FROM P&ID OF INST

MEC DW 12011
006Q-P02-158 G-13
3/IA-V-404

AND SERVICE AIR


40-IA-3-406-B.02
25-IA-3-405-B.02
25A

B-11 BSM 000


H 3/IA-V-405
H

SISTEM

80-1A-0-210-B.02
15-IA-3-407-B.02

15A

UNIT NO.1 UNIT NO.2 3/IA-V-407 UNIT NO.3 UNIT NO.4 UNIT NO.5 UNIT NO.6
(SAME AS UNIT NO.3) (SAME AS UNIT NO.3) (SAME AS UNIT NO.3) (SAME AS UNIT NO.3) (SAME AS UNIT NO.3)

I 80A I
TO P&ID OF YARD
INST AIR SISTEM
G-10 006Q-P02-160

APPROVED FOR CONSTRUCTION


15-IA-30-002-006 BSM 000
MEC DW 12011 A-2 TO WORK SHOP Hitachi,Ltd.
J Hitachi,Ltd.
14-APR,-1984 APPROVED J
BSM 000 Signed Date STEP - 2
MEC DW 12011 A-2 TO ADMINST BLD.G

UNIT 0 PROJ.
NO. 1 ~ 6 DWG.NO. HTC 000 INS DW 85225 B
MARUBENI CONSORTIUM
NATIONAL ELECTRIC POWER AUTHORITY

K NIGERIA
LAGOS THERMAL STATION - EGBIN
CONSULTING ENGINEERS - SHAWMONT LTD.
K
DWN. TITLE

CHKD.
ANG. PROJ. P & ID OF
SCALE
THIS DRAWING IS THE PROPERTY OF HITACHI LTD. DELIVERY HEREOF IS MADE UPON THE UNIT INSTRUMENT
APPD NOT.S
UNDERSTANGDING THAT IT WILL NOT BE COPIED IN WHOLE OR IN PART. THAT IT WILL BE
RETURNED UPON REQUEST AND THAT THE INFROMATION AND DATA THEREIN CONT
AIR SYSTEM
AINED WILL BE KEPT CONFIDENTIAL AND NOT DISCLOSED TO ANY OUTSIDERS.
Hitachi, Ltd. DWG. NO.
A
REV

Tokyo Japan 006Q - P02 - 159 B