11. Horizontal Fuse Switch & Surge Protection Device/Surge Arrester ..................................................................... 21
HGS HG30I HG30 HG40 / HG40I HG50 / HG50I HG82, HG100, HG120,
HG150, HG170 & HG220
CT HOWIG window types & busbar types are designed for measuring instrument with high accuracy class.
CT HOWIG can be used either for analog or digital measuring instrument.
Each unit has been tested and marked with serial number to guarantee the quality of the product.
Casing Material: Polycarbonate (self-extinguishable).
CT accuracy class 0.1, 0.2, 0.2S, and 0.5S and CT ratio …/1A can be requested as a special order.
Voltage Insulation: 3kV, 50Hz at 1 minute with Ith ≥ 60In.
*CT ratio 100/5A up to 300/5A class 0.5S and 300, 400, 600, 1000/5A Class 0.5 were certified by PLN & TKDN.
Specification
Highest voltage for equipment Um (RMS) : 0.72 kV
Rated power-frequency withstand voltage (RMS) : 3 kV
Rated short-time thermal current (Ith) : 60 In
Rated dynamic current (Idyn) : 2.5 Ith
FS : <5
Class of insulation :E
Rated frequency : 50/60 Hz
Working temperature : 0° - 50° C
Storage temperature : -10° - +70° C
Relative humidity : 95% (non-condensing)
Casing material : Polycarbonate
Standard : IEC 60044-1 & 61689-2
HG 82 Type
Limit of ratio error and phase displacement for measuring CT (SPLN D3.014-1:2009/IEC 60044-1)
% Nominal Current
Testing Parameter Accuracy Class
1 5 20 100 120
0.1 - 0.4 0.2 0.1 0.1
0.2 - 0.75 0.35 0.2 0.2
Dimension (mm)
Type W B H A d L1 L2 L3 L4
HGS 68 38 86 - - 13 - - -
HG 30I 60.5 33 80 - 23 30.5 11 - -
HG 30 75 42 98 44 - 31.5 11 11.5 21
HG 40I 75 40 98 43.5 31 42 11 11 42
HG 40 75 40 98 43.5 31 42 11 11 42
HG 50I 82 40 98 43 37 51 16 11 42
HG 50 82 40 98 43 37 51 16 11 42
HG 52 87 46 106 54 - 52 31.5 - -
HG 82 122 47 118 60.5 - 82 32.5 - -
HG 100 140 50 122.5 75 62 102 32 - -
HG 120 169 48 139 54 - 122 52 - -
HG 150 198 49 230 - - 152 134 - -
HG 170 260 54 221 - - 171 103 - -
HG 220 272 55 188 - - 227 65 - -
L1
P1
Specification
Highest voltage for equipment Um (RMS) : 0.72 kV
Rated power-frequency withstand voltage (RMS) : 3 kV
Rated short-time thermal current (Ith) : 60 In
Rated dynamic current (Idyn) : 2.5 Ith
FS : <5
Class of insulation :E
Rated frequency : 50/60 Hz
Working temperature : 0° - 50° C
Storage temperature : -10° - +70° C
Relative humidity : 95% (non-condensing)
Casing material : Polycarbonate
Standard : IEC 60044-1 & 61689-2
Dimension (mm)
Type W H B L1 L2
HSCT 0203 - 250 90.5 107 59 33 22
HSCT 0406 - 400 114 137 59 62 42
HSCT 0406 - 500 114 137 59 62 42
HSCT 0406 - 600 114 137 59 62 42
HSCT 0406 - 800 114 137 59 62 42
HSCT 0508 - 800 132 163 63 84 52
HSCT 0508 - 1000 132 163 63 84 52
HSCT 0510 - 1200 142 185 70 104 52
HSCT 0510 - 1500 142 185 70 104 52
HSCT 0510 - 1600 142 185 70 104 52
HSCT 0614 - 2000 163,5 223 70 144 63,5
HSCT 0614 - 2500 163,5 223 70 144 63,5
HSCT 0614 - 3000 163,5 223 70 144 63,5
HSCT 0614 - 3200 163,5 223 70 144 63,5
HSCT 0816 - 4000 184 245 71 164 82
HSCT 0816 - 5000 184 245 71 164 82
HSCT 0816 - 6000 184 245 71 164 82
HSCT 0816 - 6300 184 245 71 164 82
H
ID
CT PROTECTION CT MEASUREMENT
OD
Specification
Highest voltage for equipment Um (RMS) : 0.72 kV
Rated power-frequency withstand voltage (RMS) : 3 kV
Rated short-time thermal current (Ith) : 60 In
Rated dynamic current (Idyn) : 2.5 Ith
FS : <5
Class of insulation :E
Rated frequency : 50/60 Hz
Working temperature : 0° - 50° C
Storage temperature : -10° - +70° C
Relative humidity : 95% (non-condensing)
Housing material : Resin Coating
Standard : IEC 60044-1 & 61689-2
Dimension (mm)
Type Ratio Class Burden (VA) Price (IDR)
ID OD H
HGPR5P10 - 100 100 / 5A 5P10 5 45 106 98 630.000
HGPR5P10 - 150 150 / 5A 5P10 5 45 106 83 630.000
HGPR5P10 - 200 200 / 5A 5P10 5 45 106 83 630.000
HGPR5P10 - 250 250 / 5A 5P10 5 45 106 83 630.000
HGPR5P10 - 300 300 / 5A 5P10 10 45 106 83 640.000
HGPR5P10 - 400 400 / 5A 5P10 10 45 106 83 685.000
HGPR5P10 - 500 500 / 5A 5P10 10 60 115 68 650.000
HGPR5P10 - 600 600 / 5A 5P10 10 60 115 68 650.000
HGPR5P10 - 800 800 / 5A 5P10 15 90 135 60 675.000
HGPR5P10 - 1000 1000 / 5A 5P10 15 90 135 60 700.000
HGPR5P10 - 1200 1200 / 5A 5P10 15 90 135 50 725.000
HGPR5P10 - 1500 1500 / 5A 5P10 15 90 135 50 750.000
HGPR5P10 - 1600 1600 / 5A 5P10 15 90 135 50 775.000
HGPR5P10 - 2000 2000 / 5A 5P10 15 130 180 40 865.000
HGPR5P10 - 2500 2500 / 5A 5P10 15 130 180 40 950.000
HGPR5P10 - 3000 3000 / 5A 5P10 15 130 185 44 1.100.000
HGPR5P10 - 3200 3200 / 5A 5P10 15 130 185 44 1.125.000
HGPR5P10 - 4000S 4000 / 5A 5P10 15 140 200 35 1.275.000
HGPR5P10 - 5000S 5000 / 5A 5P10 15 185 240 44 1.500.000
HGPR5P10 - 6300S 6300 / 5A 5P10 15 190 245 43 1.800.000
HGPR5P10 - 4000L 4000 / 5A 5P10 15 190 255 40 1.500.000
HGPR5P10 - 5000L 5000 / 5A 5P10 15 230 290 43 1.750.000
HGPR5P10 - 6300L 6300 / 5A 5P10 15 230 290 43 2.000.000
* For special specification CT Protection requirement (10P10, 5P20, 10P20, Ratio.../1A or special burden), Please contact us.
Dimension (mm)
Type Ratio Class Burden (VA) Price (IDR)
ID OD H
HGRG05 - 100 100 / 5A 0.5 5 35 84 48 345.000
HGRG05 - 150 150 / 5A 0.5 5 33 72 45 205.000
HGRG05 - 200 200 / 5A 0.5 5 35 72 36 175.000
HGRG05 - 250 250 / 5A 0.5 5 45 72 36 175.000
HGRG05 - 300 300 / 5A 0.5 5 45 72 36 175.000
HGRG05 - 400 400 / 5A 0.5 5 45 72 36 175.000
HGRG05 - 500 500 / 5A 0.5 10 65 98 33 225.000
HGRG05 - 600 600 / 5A 0.5 10 65 98 33 230.000
HGRG05 - 800 800 / 5A 0.5 15 65 98 33 235.000
HGRG05 - 1000 1000 / 5A 0.5 15 95 135 35 480.000
HGRG05 - 1200 1200 / 5A 0.5 15 95 135 35 500.000
HGRG05 - 1500 1500 / 5A 0.5 15 95 135 35 520.000
HGRG05 - 1600 1600 / 5A 0.5 15 95 135 35 530.000
HGRG05 - 2000 2000 / 5A 0.5 15 130 180 38 615.000
HGRG05 - 2500 2500 / 5A 0.5 15 130 180 38 660.000
HGRG05 - 3000 3000 / 5A 0.5 15 130 180 38 710.000
HGRG05 - 3200 3200 / 5A 0.5 15 130 180 38 745.000
HGRG05 - 4000S 4000 / 5A 0.5 15 140 190 40 870.000
HGRG05 - 5000S 5000 / 5A 0.5 15 175 229 40 1.000.000
HGRG05 - 6300S 6300 / 5A 0.5 15 190 244 40 1.350.000
HGRG05 - 4000L 4000 / 5A 0.5 15 175 229 40 895.000
HGRG05 - 5000L 5000 / 5A 0.5 15 230 283 38 1.220.000
HGRG05 - 6300L 6300 / 5A 0.5 15 230 283 38 1.425.000
Specification
Rate Frequency : 50/60Hz
Rate Test Voltage : 3 kV AC (1min)
Rated short-time thermal current (Ith) : 60 In
Rated Dynamic Current (Idyn) : 2.5 Ith
Rated Voltage (Um) : 0.72kV AC
Continuous Overload (Id) : 1.2In
Operating Temperature : -10° - 50° C
Housing Self Extinguishing Class : V0
Safety Factor : FS 5
Secondary Current : 5A/1A
Standard : IEC 60044-1 & 61689-2
* Other technical specification, can be made by request.
HGTO 242
HGTO 248
Drawing Dimension
L2
L2
H B
H B L1
L1
W
W
HGTO242 HGTO248
Dimension (mm)
Type W H B L1 L2
HGTO0242 105 80 53 25 21
HGTO0248 140 90 53 31 31
HPM - 96/500
Type Voltage Price (IDR)
HPM - 72/500 0 - 500VAC 98.000
HPM - 96/500 0 - 500VAC 98.000
HPM - 72/V30 0 - 30VDC 150.000
HPM - 96/DV500 (Double Volt) 0 - 500VAC 475.000
Kilowatt Meter
Measuring : Via CT .../5A, .../1A (by request),
Accuracy class :3
Frequency : 50-60Hz
Standard : IEC 61010
Response time : 8min/15min/30min
Power consumption : ≤2VA
Frame size : 96x96 mm
Hour Meter
Measuring : 0-99999.99hour
Rated voltage : 220 VAC
Display : 0-99999.99hour HPM - 96/DFV
Power consumption : ≤7VA
Frame size : 72x72
HPM - 72/HC
Dimension
Type Unit A B C D E F
AC & DC Ampere Meter (72 x 72) mm 72 67.7 66.5 81 68.5 43
Power Factor (Cos phi) Meter (72 x 72) mm 72 67.7 66.5 81 68.5 43
Power Factor (Cos phi) Meter (96 x 96) mm 96 90.7 89.5 81 68.5 43
HOWIG with Accessories (Pilot Lamp, Push Button and Selector Switch)
are having an ergonomic and elegant design.
Comply IEC 60947-1 and IEC 60529 standard.
Longer mechanical durability.
Type
Color Price (IDR)
230VAC 110VAC 24VDC
HPL - 43021 HPL - 41121 HPL - 42421 Green 11.500
HPL - 43022 HPL - 41122 HPL - 42422 Red 11.500
HPL - 43023 HPL - 41123 HPL - 42423 Orange 11.500
HPL - 43026 - - Yellow 11.500
HPL - 43024 - - Blue 12.500
HPL - 43026
HPL - 43025 - - White 12.500
HDPB - 4333
HEM - 4000
HEM - 4000 PC
HSV 48
HSA 48
HS00 48
Fuse Holder
Max.
Type Size (mm) Fuse Indicator Price (IDR)
Ampere
FH32 - S 32A 10x38 Without Indicator 21.800
FH32 - SL 32A 10x38 With Indicator 23.800
FH41 -S 50A 14 x 51 Without Indicator 49.000
FH32-S FH32-SL FH41-S
Fuse Link
Type Rating (A) Description Price (IDR)
FO3802 2 gG (10x38mm) 3.600
FO3804 4 gG (10x38mm) 3.600
FO3806 6 gG (10x38mm) 3.600
FO3810 10 gG (10x38mm) 3.600
FO3816 16 gG (10x38mm) 3.600
FO3820 20 gG (10x38mm) 3.600
FO3825 25 gG (10x38mm) 3.600
FUSE LINK FUSE LINK
FO3832 32 gG (10x38mm) 3.600
(10X38 mm) (14X51 mm)
F1440 40 gG (14x51mm) 9.000
F1450 50 gG (14x51mm) 9.000
* for 22x58mm fuse holder & fuse link, please contact us.
NH Fuse is designed and manufactured with high-quality material comply with IEC 60269-1 and ROHS standard.
NH Fuse gG/gL type used for overload and short circuit protection.
NH Fuse and Fuse Base have type test certificate from TÜV Rheinland and ROHS and Qualified PLN standard
test for SKTR/PHBTR (Low Voltage Switchboard).
Low dissipation power.
Breaking Capacity 120 kA at 500VAC, 50Hz.
690VAC aM type NH Fuse can be requested as a special order.
NH Fuse Size 00
Type Rating Current In (A) Voltage (V) Breaking Capacity (kA) Price (IDR)
05851 25 500~ 120 28.000
05852 32 500~ 120 28.000
05853 35 500~ 120 28.000
05854 40 500~ 120 28.000
05855 50 500~ 120 28.000
SIZE 00/50A
05856 63 500~ 120 28.000
05857 80 500~ 120 28.000
05858 100 500~ 120 28.000
05859 125 500~ 120 28.000
05860 160 500~ 120 28.000
NH Fuse Size 1
Type Rating Current In (A) Voltage (V) Breaking Capacity (kA) Price (IDR)
05888 63 500~ 120 57.500
05889 80 500~ 120 57.500
05890 100 500~ 120 57.500 SIZE 1/125A
05867 125 500~ 120 57.500
05868 160 500~ 120 57.500
05869 200 500~ 120 57.500
05893 224 500~ 120 57.500
05870 250 500~ 120 57.500
NH Fuse Size 2
Type Rating Current In (A) Voltage (V) Breaking Capacity (kA) Price (IDR)
05881 100 500~ 120 92.500
05882 125 500~ 120 92.500
SIZE 2/400A
05883 160 500~ 120 92.500
05871 200 500~ 120 92.500
05872 250 500~ 120 92.500
05873 300 500~ 120 92.500
05884 315 500~ 120 92.500
05874 400 500~ 120 92.500
NH Fuse Size 3
Type Rating Current In (A) Voltage (V) Breaking Capacity (kA) Price (IDR)
05879 400 500~ 120 128.500
05875 500 500~ 120 128.500
SIZE 3/400A
05876 630 500~ 120 128.500
TEST REPORT
TEST REPORT
IEC 60269-1
IEC 60269-1
Low-voltage fuses Low-voltage fuses
Part 1: General requirements Part 1: General requirements
Report Number. ..............................: 15081674 001-P1
Report Number. .............................. : 15081673 001-P1
Date of issue ...................................: 09.02.2015
Date of issue ................................... : 09.02.2015
Total number of pages .................... 49
Total number of pages .................... 56
Test specification:
Test specification:
Standard .......................................... : IEC 60269-1:2006 (Fourth edition)+ A1:2009
Standard .......................................... : IEC 60269-1:2006 (Fourth edition)+ A1:2009
Test procedure ...............................: IEC report
Test procedure ............................... : IEC report
Non-standard test N/A
Non-standard test N/A method…………..:
method…………..:
Test Report Form No......................: IEC60269_1B
Test Report Form No...................... : IEC60269_1B
Test Report Form(s) Originator..... : EZU
Test Report Form(s) Originator.....: EZU
Master TRF ......................................: Dated 2010-08
Master TRF ...................................... : Dated 2010-08
Copyright © 2010 Worldwide System for Conformity Testing and Certification of Electrotechnical
Copyright © 2010 Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.
from the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed.
CB Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Test item description ..................... : Low-voltage fuse
Test item description .................... : Low-voltage fuse
Trade Mark ...................................... :
Trade Mark ......................................:
Manufacturer................................... :
Manufacturer ...................................:
Model/Type reference .................... : Fuse-link:NH00, NH00C or NH000; Fuse-base:NHB00
Model/Type reference ....................: Fuse-link:NH1 or NH1C; Fuse-base:NHB1
Ratings ............................................ : NH00, NH00C or NH000: 16A, 20A, 25A, 32A, 40A, 50A, 63A,
Ratings ............................................: NH1 or NH1C: 80A,100A,125A,160A,200A,224A,250A; AC
80A, 100A, 125A, 160A; AC 500V; BC:120kA; gG;Size 00
500V; BC:120kA; gG; Size 1
NHB00:160A; AC690V; gG;Size 00
NHB1:250A; AC690V; gG; Size 1
TEST REPORT
IEC 60269-1
Low-voltage fuses
Part 1: General requirements
Report Number. ..............................: 15081675 001-P1
Date of issue ...................................: 09.02.2015
Total number of pages .................... 45
Test specification:
Standard .......................................... : IEC 60269-1:2006 (Fourth edition)+ A1:2009
Test procedure ...............................: IEC report
Non-standard test N/A
method…………..:
Test Report Form No......................: IEC60269_1B
Test Report Form(s) Originator..... : EZU
Master TRF ......................................: Dated 2010-08
Copyright © 2010 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting
from the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the
CB Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory
and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Manufacturer ...................................:
Model/Type reference ....................: Fuse-link:NH2 or NH2C; Fuse-base:NHB2
Ratings ............................................: NH2 or NH2C: 160A,200A,224A,250A,315A,400A; AC 500V;
BC:120kA; gG; Size 2
NHB2:400A; AC690V; gG; Size 2
NH Fuse Base (Ceramic) is designed and manufactured with high quality material comply with IEC 60269-2.
Fuse Base (Ceramic) have type test from Independent Laboratory and Qualified PLN standard test for SKTR/
PHBTR (Low Voltage Switchboard).
The bases are made from high density metal, better at releasing heat.
Dimension (mm)
Type A B C D E F G H I J K
HFT00-160MT - 100 120 58 59.2 29 2-M8 25 2Ø-8 32 -
HFT1-250MT 198 175 152 80 79.5 37 2-M10 25 2Ø-10.5 50 30
HFT2-400MT 225 200 152 80 91.5 37.5 2-M10 25 2Ø-10.5 50 30
HFT3-630MT 242 210 152 80 98.5 38 2-M12 25 2Ø-10.5 50 30
NH Fuse Base (DMC) is designed and manufactured with high quality material comply with IEC 60269-2.
Fuse Base (DMC) have type test from Independent Laboratory and ROHS and Qualified PLN standard
test for SKTR/PHBTR (Low Voltage Switchboard).
The bases are made from high density DMC, featured with good heat release, high mechanic density, reliable
connection and simple operation.
Dimension (mm)
Type A B C D E F G H
HFT00-160DM 120 100 59 25 - 2-Ø7.5 2-Ø14.5 57
HFT1-250DM 200 175 80 25 30 2-Ø12 - 85
HFT2-400DM 224 200 80 25 30 2-Ø12 - 86
HFT3-630DM 235 210 80 25 30 2-Ø12 - 86
Fuse Puller
B
b
E
d
G
a
H H D
A
Max.
Impulse
Nominal Continous Voltage
Current
Voltage Operating Protection
Type Pole Model (8/20µS) Price (IDR)
Voltage
Level
Imax. (kA) Un (V) Uc (V)
Up (kV)
BY7-20/2-275 1P+N Draw Out 20 220 275 1.2 300.000
BY7-40/2-275 1P+N Draw Out 40 220/400 275 1.5 400.000
BY7-20/4-440 3P+N Draw Out 20 220/400 440 2.0 550.000
BY7-40/4-440 3P+N Draw Out 40 220/400 440 2.2 700.000
BY7-60/4-440 3P+N Monoblock 60 220/400 440 2.2 1.100.000
BY7-80/4-440 3P+N Monoblock 80 220/400 440 2.5 1.800.000
BY7-100/4-440 3P+N Monoblock 100 220/400 440 2.8 2.900.000
Cylindrical Insulator
Type ø (D1/D2) Height (mm) Bolt Size Price (IDR)
HBCI - 3030 18/30 30 M6 5.800
HBCI - 3040 18/30 40 M6 6.850
HBCI - 4040 28/40 40 M8 9.900
HBCI - 4060 26/40 60 M10 15.500
HBCI - 4060 26/40 60 M8 14.000
HBCI - 5040 31.5/50 40 M8 16.500
HBCI - 5060 30.5/50 60 M10 22.000
HBCI - 6060 54/60 60 M12 33.000
H D1 D2 H D1 D2
30 30
21 21 21 21 33 41
33 37
15
M6 M8 33 M8 37
15
60 130 148
15 33 37
M8
15
Ø11 M10 33 Ø11 M10 37
15 45 40
70 70
Step Insulator
EL Series
MV Insulator
HOWIG busbar support is made from Sheet Moulding Compound (SMC) material. It’s a glass-fibre reinforced polyester
that has high dielectric and mechanical strength. This material is also used in many industries such as mechanical,
chemical or electric vehicle due to its mechanical strengthness.
SMC material also has high resistant and V0 fire retardant, which fit to be used as busbar support material.
Insulating Pipe
HBS3P385-307/311
35 35
35
40 40
35
0
21 3
30
5
38
HBS4P500-307/311
HBEL - 270
HBEL - 409
HBEL - 130
HBEL - 180
130
180
9x2 7x2
12x2 8x2
9 11 25 65 65 25
A 34
35
6 6.5 15
10
28.15
15 100 15
35 57.5 65 57.5
19
409
12x2
20x2 12x2
6 A
10 A 35
5
35 10
10 35
5
10 100 100 B 35 9 B
270
98.7 106 106 98.7
Busbar Supports
Type No. of Pole Length (mm) Busbar Size (mm) Price (IDR)
HBEL - 130 1 Pole 130 3x5 / 4x10 27.000
HBEL - 180/5 3 Pole 180 3x5 25.000
HBEL - 180/10 3 Pole 180 3x10 25.000
HBEL - 270 3 Pole 270 3x5 / 2x10 54.000
HBEL - 409 4 Pole 409 2x5 / 2x10 95.000
RAW Material : DMC (Dough Moulding Compound)
HGPS-0524
HOWIG DIN Rail Power Supply is completed with Short-Circuit, Over-Voltage and Over-Load protection.
Low Power Consumption, High efficiency, Reliable and compact size.
Working Temperature -10°C up to +70°C.
Humidity 90%.
Detuned reactor or Harmonic blocking reactor is generally use in series with capacitor in Power factor correction
system, in order to reach its target to reduce the current. It can be tuned to a certain frequency to absorb the harmonic current
in the grid.
Hefftron Detuned reactor is made of the high quality transformer sheets and aluminium or copper coil with dried and impregnated
in vacuum with environmentally-friendly, low-styrol resin which ensures high voltage witstand, low noise level and enjoy a long
operating life.
They are fully manufactured by the factory which has more than 20 years experience for producing power quality products, such
as: LV & MV Detuned Reactor, MV Current Limiting Reactor, LV Shunt Reactor, Passive Harmonic Filter, Reactor for Frequency
Converter & Sine Wave Filter.
Features :
• Lower temperature rise.
• Stand 25 times short circuit current in 1 second.
• Over heat protection.
• Copper connections.
• Low noise level.
Technical Specification
Three Phase Detuned Reactor for Capacitor 525VAC ( Vn=400VAC 50Hz, p = 7%, fr = 189Hz )
Reactor Inductance Capacitor
I rms In Dimension Weight
Type @400VAC (L) 525VAC Price (IDR)
(Kg)
(kVAr) (mH) (kVAr) (A) (A) LxWxH (mm)
HFT-DR7125/400 12,5 3,072 20 20,3 18 210x175x175 12 2.000.000
HFT-DR7156/400 15,6 2,458 25 25,4 22,5 210x175x175 12 2.600.000
HFT-DR7250/400 25 1,536 40 40,7 36 230x165x200 19 3.500.000
HFT-DR7312/400 31,2 1,229 50 50,8 45 230x165x210 19 4.000.000
HFT-DR7500/400 50 0,768 80 81,4 72 275x175x240 31 5.000.000
HFT-DR7624/400 62,4 0,614 100 101,7 90 300x190x270 43 6.000.000
HFT-DR7100/400 100 0,384 160 162,7 144 360x225x330 69 9.000.000
Three Phase Detuned Reactor for Capacitor 450VAC ( Vn=400VAC 50Hz, p = 7%, fr = 189Hz )
Reactor Inductance Capacitor
I rms In Dimension Weight
Type @400VAC (L) 450VAC Price (IDR)
(Kg)
(kVAr) (mH) (kVAr) (A) (A) LxWxH (mm)
HFT-DR7212/400 21,2 1,808 25 34,6 30,6 225x160x205 18 3.500.000
HFT-DR7424/400 42,4 0,904 50 69,2 61,3 260x180x240 29 4.700.000
HFT-DR7848/400 84,8 0,452 100 138,4 122,6 300x200x270 43 7.200.000
F
H H F
H F
E2 D
E1 D
E
W D E L W
L L W
HFT-DR7125 & 7156 HFT-DR7250, 7312, 7500, 7624, 7212, 7424 & 7848 HFT-DR7100
Dimension (mm)
Type
L W H E E1 E2 F D
HFT-DR7125/400 210 175 175 100 - - 95 Ø10-20
HFT-DR7156/400 210 175 175 100 - - 95 Ø10-20
HFT-DR7250/400 230 165 200 200 150 75 105 Ø10-20
HFT-DR7312/400 230 165 210 200 150 75 105 Ø10-20
HFT-DR7500/400 275 175 240 235 150 90 115 Ø10-20
HFT-DR7624/400 300 190 270 250 165 105 140 Ø10-20
HFT-DR7100/400 360 225 330 205 - - 140 Ø12-22
HFT-DR7212/400 225 160 205 195 150 75 105 Ø10-20
HFT-DR7424/400 260 180 240 230 150 90 115 Ø10-20
HFT-DR7848/400 300 200 270 245 160 100 140 Ø10-20
Measures kWh, kVARh, kW, kVAR, kVA, P, F, PF, Hz, Dmd, V, A, etc.
Bi-directional measurement IMP & EXP.
Energy information of each phase.
Total harmonic distortion of voltage and current.
2nd~63rd Individual harmonic distortion.
RS485 Modbus RTU & two pulse outputs.
Bar graph for power indication.
Three phase self-power supply.
Backlit LCD display for full viewing angles.
High accuration class.
Plug-in Play solution. HFPM-96F/I
Real time clock.
Dimension: 96x96mm.
Via CT..../1A or ..../5A.
Measurement
Type Display Connection Size Voltage Price (IDR)
Parameter
HDM9648 - U30 1 Row, Digital LED Direct DC Voltage 96x48 mm 0 - 30VDC 225.000
HDM9648 - I30 1 Row, Digital LED Via Shunt Resistor AC Voltage 96x48 mm 0 - 30ADC 225.000
HDM-SHUNT Shunt Resistor for DC Ampere Meter 0 - 75mV - - 55.000
Load Break Switch is 3 & 4 Pole manually operated, consisting two sets of terminals for
connecting to incoming supply & load. It ensures safe isolation and is suitable for use in
individual enclosures, switch boards, lighting and power panels etc,
with following features :
• Suitable for incoming and outgoing feeders.
• 2 stable positions (I - O).
• Fully visualized breaking.
• Pre equipped terminal cover, phase barrier with all ratings.
• Quick Make & Break type irrespective of human torque.
• Resistant to Tropical conditions & polluted environment.
• High thermal & dynamic withstand capacity.
• Self-extinguishing fiberglass reinforced insulating body.
• Available in Open execution, Steel sheet enclosure & Direct Mounted type.
• AC 23A Category.
• Bounce free contacts.
• Any pole can be used as Neutral pole... true 4 pole switch.
• Unique Safety Handle with built in door padlock facility.
• Padlockable in “OFF” position
• Castle lock, interlocking two isolators.
• High Electrical & Mechanical life.
Handle up to 630A Handle for 800A & Above Auxiliary Contact Extend Shaft
Handle up to 630A Inter Phase-Barriers Terminal Shroud 8.8 Bolts & Nuts Bridging Bar
Manual Changeover Switch is 4 Pole manually operated, consisting it two sets of terminals
for connecting of two incoming supply sources. ensures safe changeover from one source
to another and is suitable for use in individual enclosures, switch boards, lighting & power
panels etc. with following features :
• Suitable for incoming and outgoing feeders.
• 3 stable positions ( I – O – II ) & Fully visualized breaking.
• Bridging bars mounted on all ratings as standard feature.
• Pre-equipped terminal cover, source separator, phase barrier with all ratings.
• Quick Make & Break type irrespective of human torque.
• Resistant to Tropical conditions & polluted environment.
• High thermal & dynamic withstand capacity.
• Self-extinguishing fiberglass reinforced insulating body.
• Available in Open execution, Steel sheet Enclosure & Direct Mounted type.
• AC 23A Category & Bounce free contacts.
• Any pole can be used as Neutral pole true 4 pole switch.
• Unique Safety Handle with built in door padlock facility.
• 3 lockable pad in “ON & OFF” position
• Castle lock, interlocking schemes with MCCB/ACB.
• High Electrical & Mechanical life.
Handle up to 630A Handle for 800A & Above Auxiliary Contact Extend Shaft
Handle up to 630A Inter Phase-Barriers Terminal Shroud 8.8 Bolts & Nuts Bridging Bar
Handle up to 630A Bridging Bar 8.8 Bolts & Nuts Terminal Shroud Inter-Phase Barriers
Handle with
padlock lever