Notes : 1. S
pecial wall pieces can be supplied with restrained joint bells and spigots. These joint rings
must protrude beyond the face of the structure to permit proper assembly of the joint.
2. F
lange and mechanical joint bell ends can be supplied with tapped (threaded) bolt holes such
that the face of the flange or mechanical joint bell ends can be cast flush with the inside face of
the structure.
3. Wall pieces with ends other than those shown here can be supplied.
4. W
hen wall pieces with restrained joint ends and water stops or anchor rings are specified,
thrust will be transmitted into the wall of the structure. Design of the structure for such thrust
is not Thompson Pipe Group’s responsibility.
11.6
WALL PIECES – DIMENSIONS
18 6 6 5 4-1/2 1/2 2
20 6 6 5 4-1/2 1/2 2
24 6 6 5 4-1/2 1/2 2
30 6 6 5 4-1/2 1/2 2
36 6 6 5 4-1/2 1/2 2
42 6 6 5 4-1/2 1/2 3
48 6 6 5 4-1/2 1/2 3
Notes : 1. N
ormally the waterstop is located at mid-wall of the structure. Distances listed are the
minimum distances possible with standard joints.
2. D
imensions given are for deep joints in diameters 16- to 48-inch and standard joints in
diameters 54- to 96-inch.
3. Wall pieces with other end connections are available.