2022 Oct 22 03:53:06 ie-dinc-nxhzn4-2 %PFMA-2-PS_HIGH_VIN: Input Voltage 959

exceeded maximum threshold of 72V for Power supply 1.


2022 Oct 22 04:35:56 ie-dinc-nxhzn4-2 %VSHD-5-VSHD_SYSLOG_CONFIG_I: Configured from
vty by lpaius on 172.31.133.5@pts/0
2022 Oct 22 04:55:35 ie-dinc-nxhzn4-2 %PFMA-2-PS_HIGH_VIN: Input Voltage 959
exceeded maximum threshold of 72V for Power supply 1.
2022 Oct 22 19:38:48 ie-dinc-nxhzn4-2 %PFMA-2-PS_HIGH_VIN: Input Voltage 959
exceeded maximum threshold of 72V for Power supply 1.
2022 Oct 23 20:01:23 ie-dinc-nxhzn4-2 %PFMA-2-PS_FAIL: Power supply 1 failed or
shutdown(Serial number POG2236XT13)
2022 Oct 23 20:01:23 ie-dinc-nxhzn4-2 %NOHMS-2-NOHMS_DIAG_ERR_PS_FAIL: System minor
alarm on power supply 1: failed
2022 Oct 23 20:01:24 ie-dinc-nxhzn4-2 %NOHMS-2-NOHMS_DIAG_ERR_PS_RECOVERED:
Recovered: From System minor alarm on power supply 1
2022 Oct 23 20:47:34 ie-dinc-nxhzn4-2 %PFMA-2-PS_HIGH_VIN: Input Voltage 959
exceeded maximum threshold of 72V for Power supply 1.
2022 Oct 24 22:15:59 ie-dinc-nxhzn4-2 %PFMA-2-PS_FAIL: Power supply 1 failed or
shutdown(Serial number POG2236XT13)
2022 Oct 24 22:15:59 ie-dinc-nxhzn4-2 %NOHMS-2-NOHMS_DIAG_ERR_PS_FAIL: System minor
alarm on power supply 1: failed
2022 Oct 24 22:16:00 ie-dinc-nxhzn4-2 %NOHMS-2-NOHMS_DIAG_ERR_PS_RECOVERED:
Recovered: From System minor alarm on power supply 1
2022 Oct 25 07:07:37 ie-dinc-nxhzn4-2 %PFMA-2-PS_FAIL: Power supply 1 failed or
shutdown(Serial number POG2236XT13)
2022 Oct 25 07:07:37 ie-dinc-nxhzn4-2 %NOHMS-2-NOHMS_DIAG_ERR_PS_FAIL: System minor
alarm on power supply 1: failed
2022 Oct 25 07:07:38 ie-dinc-nxhzn4-2 %NOHMS-2-NOHMS_DIAG_ERR_PS_RECOVERED:
Recovered: From System minor alarm on power supply 1
2022 Oct 25 10:26:56 ie-dinc-nxhzn4-2 %PFMA-2-PS_FAIL: Power supply 1 failed or
shutdown(Serial number POG2236XT13)
2022 Oct 25 10:26:57 ie-dinc-nxhzn4-2 %NOHMS-2-NOHMS_DIAG_ERR_PS_FAIL: System minor
alarm on power supply 1: failed
2022 Oct 25 10:26:57 ie-dinc-nxhzn4-2 %NOHMS-2-NOHMS_DIAG_ERR_PS_RECOVERED:
Recovered: From System minor alarm on power supply 1
2022 Oct 26 01:18:52 ie-dinc-nxhzn4-2 %PFMA-2-PS_HIGH_VIN: Input Voltage 959
exceeded maximum threshold of 72V for Power supply 1.

NAME: "Power supply 1", DESCR: "DC power supply"


PID: N55-PDC-1100W , VID: V01 , SN: POG2236XT13

Temperature
-----------------------------------------------------------------
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
-----------------------------------------------------------------
0 Fan Side 110 100 29 ok
0 Port Side 110 100 46 ok
0 PS-1 110 100 30 ok
0 PS-2 110 100 34 ok
0 Control 68 58 37 ok

Power Supply:
Voltage: 12 Volts
-----------------------------------------------------------
PS Model Input Power Current Status
Type (Watts) (Amps)
-----------------------------------------------------------
1 N55-PDC-1100W DC 1080.00 90.00 ok
2 N55-PDC-1100W DC 1080.00 90.00 ok

Power Usage Summary:


--------------------
Power Supply redundancy mode: Redundant
Power Supply redundancy operational mode: Redundant

Total Power Capacity 2160.00 W

Power reserved for Supervisor(s) 300.00 W


Power currently used by Modules 249.84 W

-------------
Total Power Available 1610.16 W
-------------

===============================================
https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvc90944
================================================

This bug is cosmetic in nature with serverity 5 (low), you can ignore this message
or upgrade to 7.3(2)N1(1) or later