Download as pdf
Download as pdf
You are on page 1of 25
Unit Elements 4.13 Operating Unit Fig: 4-17 Designation Ord. No. ‘Membrane keypad with support plate and seal... 3452 0685 LcD module ... 3450 1819 Flex cable, preformed .. 3450 8830 Frame incl. pressure spring and magnet 3450 1835 Flexible cable 42 mm (5 pcs) 3477 3347 Hinge unit : 3480 5571 Hinge gin (3 me. 34505580 Magnet 3450 5049 Exchange Tools: Screw driver Tork TS 1. Remove battery (see “2attery* pg.) 2. Disassemble the door lock. 3. Loosen countersunk screw and bridge. 4. Remove tamper-proof caps (6 pieces) on the door frame by piercing screwdriver through the caps to loosen the countersunk serews. 53. Unlatch the zero force insertion connector and loosen the fex cable. Note The position ofthe flex cable must not be changed, Le. the pre- formed section must bein the hinge area (sivot. Mark the cable, necessary, 6. Disassemble ether LCD module or support plate with ‘membrane keypad or door hinge pins respectively and ‘exchange the door frame. 7. Assemblyis donein reverse order. Payattentiontothe cor rect direction ofthe door hinge pin during assembly. Note 2 soy DDonot ink ether of the flex cables. Push the contacts to the stop of the ze force insertion connector a hock Electrical safety, functional check, purnp unit check Vial 950071 Rev A S/O) Unit Elements 4.14 Barcode Label Fig: 4-19 Designation Ord. No. Barcode label : 3450 9070, soe ‘Order Form” pg. A 2) Exchange 1. Remove old barcode label if existing. 2. Clean the adhesion surface with an alcoholic cleaning agent and let chy. 3. Loosenbarcode abelfrom thebasematerialandstickiton. Note Destroy the type plate delivered, heck ‘Check that serial number and pump symbol inthe plain text Fell of the barcode label correspond with the type plate on tho pump of the Vista basi 4.15. Frame with Seat ‘ia base 680971 Raw A (00 Designation Frame with seal plate ... Ord. No. 34501770 Exchange 1. Disassemble all parts as described before and exchange the frame with sea plate Check Electrical safety functional check, purnp unit check. Unit Elements For your notes: ‘ist bs 950971 RevA/04) 40 Checks after Repair Depending on the work caried out, perform the relevant check boss (1,2, 3 ad for 4) 1. Visual inspection 7, Safety inspection As per HECIEN eo 601-1 3. Funetional inspeetion “Pump Unit lnspection [CT OW after visual inspection ( Wiains vonage —— VAC] 10 Protective conductor re- sistance Ink, mains ‘able <0.20 (2 Insulation resistance >p2MQ (0 Earth leakage current <30pA__ pl itch on Unis ID Sef-test| [2 contre amps |Compare with Display: ID Set detivery rate Battery Test: ID) Switeh mainsbattery ID. Switch on intattery ade and check se-test |air Sensor [3 mnt air bubbles alarm ID Airvatue ID Water value ID. Calibration value (alarm threshold), adjust if nec- sary Wvatues see Tt Drop Sensor: ID Simulate oceusion alarm [alarm with closed roller clamp) 1D. Simulate Fee flow (alarm) IO stattcat [5 Alarm suppression oom Temperature 20-78" C Electronic Occlusion Pressure: [FV Check alarm with switeh- off pressure love J high [> Zero-value seting Service program function 5000 Mechanical Occlusion Pres- [3 Flow innibitor Pressure cherk = 11.651 ‘no Free flow [9 Detivery accuracy ‘Vitae 950871 Rev 08) ‘Observe the procedize information [se "Procedural nstuctions forlaspection’ pg. 8 NE st Checks after Repair For your notes: stake 950571 Rov A (510) Maintenance Itis recommended every 2 years. In action tothe technical safe- ‘inspection, perform the following inspection points: 1. Check the rubber feet and if necessary exchange. 2. Chack easy sunning of the pump cover, lock mechanism and door. 3. Check easy running ofthe low inhibitor, lean andi ocossary exchange pressure springs. 4. Check seal membrane andif necessary exchange. 5. Check the drop sensor optic and pring mechanics and clean if necessary, 6. Open unit. ternal visual inspection, Clean the seal surfaces andif necessary exchange seal stip. | occlusion pressure and if necessary 8. Checkelectronc occlusion pressureandif necessary caltrate (Gee Occlusion Sensor” pg. 4-14) 9. Assemble and seal unit ready for operation Vea bel 950971 Rav 5/08 61 ites 950971 Rer A (704) Technical Safety Inspection TSI Index Checklist for Technical Safety Inspection -Every 24 Months Unit: Vista Basic Manufacturer B Braun Melsungen AG Observe the service manual and theinstuctionsfor use. ll measured values areta be documented. Accessories used should be included in testing. Make exclusive use of calibrated measuing instruments, {(Master- tobe added to the documentation) 121 Pump sealing diaphragm 7 Softkeys, eubber feet 1D Control unit lock macha- ism, pump. 1D Flowinkititor IF) Mainscable and mains plug connector 1D MC connector ine. MFC cable 1D. Drop sensor tine and plug connector ID Check voltage values 200/230/240V=T0.16A la roo 107120V=70.135 4] ID. Protective conductor resi- tance incl mains cable <0.2 —_al I Insulation resistance >> 2M al [Earth leakage current <30uA al 3. Accessories Used I eC stat caltlead ———] No, 0406 2957 or Vista Pump. 7. Visual Inspection 2. Safety Inspection “Functional inspection Jas per IEC/ENGO501-1 ET” Gesntiness completeness |S Check mains [Switch On Unite [Drop Sensor damage voltage _VAC|O) Selftest IG simulate occlusion alarm [9 Allsymbolsintcd [a contro!lamps |Compare with Display: [Set Delivery Rate I Setvolume I settime I Press every key once lsattery Test: [switch mainsbatery/mains| Iv Switch on in battery mode ‘and check slfest lair Sensor: check with intrafix Air P Or. set, in temperature range laorc..25°c} (04 ml air bubbles alarm Air vale max. 65m0V Water value min. 455mV Alarm threshold = 130 mV ccheckand ifnecessary enter daaa with closed roller clamp IA sirmutate free flow (alarm) Electronic Occlusion Pressure {check alarm with switchoft pressure ID Low(s.8t0 145 Ps) IF High (14510232 PS) |Mechanical Occlusion Pressure: ID Max43sPst psi >261PS1 pst Staff call Pump cover alarm Alarm suppression Flow inhibitor pressure checkup to 11.6 Pino free flow ID Check delivery accuracy according to service ‘manual douae ‘CAUTION: Charge battery! ‘econ 0092 FoxD3eor2208 Vetabes 95071 Rev a(S) Technical Safety Inspection TSI (ae For yournotes: re Vitabesie95097Rev NS/O4) Procedural Instructions for Inspection 1. Visual Inspection 2. Electrical Safety Inspection as per IECIENGO 601- 1 sa baste 950571 Rov (08) Operating unit, lock mechanism, pump cover, seal mem- brane, flow inhibitor. Door lock: easy opening and closing, correct top and bottom locking. Pump cover must automatically open when the unit dooris opened, Protective Conductor Resistance Protective conductor resistance < 02 incl. mains lead. Measurement points: + Potential equalization bolt = Bolt for door lock = Unit housing 2) IF the unit isnot sealed countersunk screw at the rear of the unit, ) Ifthe units sealed, eemove lacquer fromone of the hholesin the foot stands Note Do not use the foot stand assembly screws as altemative moasurement int Document the largest value, Insulation Resistance Insulation resistance >> 2 M& Measurement with 500 V between shorted mains connectors ‘and potential equalization bolt, Earth Leakage Current Earth leakage current < 30 uA inc, mains cable, ‘Measurement under standard concitions at the protective ‘conductor of the mains cable. Two measurements (one with ‘changed poles} Document thelargest value. Procedural Instructions for Inspection 3. Funetionat Inspection ‘Switeh- on Test ‘Switch-on test keypad and display: check cortect procedure. ‘Alarrn tone, display rate 000.0, VOL, THAE etc, display of al pel, contrast, display light, alarm and operating LED. Battery Test ‘Switch mains/batterymsins: Interrupt mains supply twice in in- tenals of 1 second, Pay attention to the switeh-over in the s- play The uit must not snitch to malfunction. Note Running time minimum 30 minutes after charging of 16 hours. Air Sensor Set rate to 400 ml/h, ‘Then inject 04 ml air bubble inject piece). An alarm must be activated, Drop Sensor Set rate to 400 mi/h, = Simulate occlusion: Clampinfusion line in front of the pump to prevent any drops. Alarmin less than S sec. Simulate free flow: Press the bottom part ofthe drop. chamber together, to generate a jet. Immediate alae. Staff Call + Connect MFC test plug ~ Generate an alarm (e.g, open pump cover during oper: ation), red LEDIs on in the test plug = if dynamic is set 1 see. = if static’ set, until the alatmis acknowledged ‘Alarm Suppression Pressthe alamkey. The curentalarmts suppressed for 2minutes. Viable 80871 Rew (504) Procedural Instructions for Inspection gy 4.Pump Unit inspection Figz8-2 Vira bac o5071 Raw A508) General = Roomtemperature20-2 8° C + Use infusion line Intrafk AIR P (PVC) oF Vista PumpSet only once. = Connect an electronic pressure meter to the outside of the pump and position it to approx. medium height of the Vista basic = Measurement range: 50 P51 ‘The results lifer accorcing to diferent measurement procedures, [With electronicmeasurement devices the values may be approx. 11.45 PSthigher than indicated, Electronic Occlusion Pressure (Occlusion Sensor} Switeh off drop contro ‘Set 600 mifh and deliver nan opensystem for one minute. ‘lose the system and build-up pressure against a manometer wth 100 rh (Occlusion sensor thresholdlow.......-..+.+ 5Bt0 145 PSH (Occlusion sensor thresholdhigh........... 1451028281 ‘The pressure threshold can be changed in the service program {not recomended), Default setting: “low pressure: 87 S| high pressuret7.4 PSt Tolerance range: set value: 4.35 PSL Mechanical Occlusion Pressure + Set occlusion sensor thresholdto mechanical (test plug). + Switch off dtopeontral + Enter VTBO 190m! = Enter rate of 1000 ml/he * Build up pressure with 600 ml/h. Then change rate and measure with 10omUe. = Read 90 seconds after start of delivery: ‘Measurement upper pressure vatue (< 43.5 PSI) ‘Measurement lower pressure value (> 26.1 PSI Measured values (seo "Technical Safety Inspection TSI" p9.7-1. ‘Alter the measurement inspection the mechanical setting must be switched off The electronic occlusion pressureis not automat a3 Procedural Instructions for Inspection ‘urtomatically activated again when the service plughas been cisconnected. ‘Mechanical Pressure Setting Check pump pressure. If the deviation is max. 4.35 PSI from set range, the pump can be calibrated. Perform pressure measurement. Calibrate the pressure range attheset screw with an Allen key2.5 mm. to the upper pressure value of 34.8 PS) After the measurement inspection the mechanical setting ‘must beswitchedoff The electronic occlusion pressure isnot sutomatically activated again when the service plughas been isconnected. Flow Inhibitor ‘Switch to stop at high pressures. Then open unit door. The pressure must stay above 11.6PSI. Delivery Accuracy Temperature 22" € Rate>1 min ‘Typically 586 at a measurement of more than 8 hours. as te baie 950971 Rev A (0) Procedural Instructions for Inspection & Determination of Delivery Rate Alternative procedure (12 minutes short measurement) Temperature 20 - 28°C ‘Reference Heigh| Measurement Equipment = 500 ml glss bottle vented = _Inrafic AIRP YC) or Vista Pump Set drop chamber filed 2/3 = Graduated cylinder 25m accuracy + 04 mor cole lection device and electronic scale calibrated). + Infusion solution NaCI o dstiled water. Procedure: = Usea newinfusion line for every measurement, = Checkthe system for narrow sections or kinks, = Delivery ate 125 mi/h. = Delivery Volume 30 ml Press Start torunthe pump fr 1 minute. = Press Stop. = _tnsert the outlet cannula inthe graduated eyinder or zexoseale. = Measurement rate: 125 mI = Measured volume: 25m = Simultaneously start stop watch and Vista basic. ‘top when the 25 ml mark on the graduated cylinder or 25g on the scale is reached and read time. = _Asshowninthe graph the delivery behaviour lightly changes abasic 950971 Rey A908) ‘ver the infusion time. Consequently the tolerances mast be Inthe upper range when the daivery accuracy (59% over 8 hhours)ischeckedwitha short measurernent over 12 minutes. = Expected rate deviation due to the short time method: Software IFVA:+2.59% tolerance range 2.5% to 47.5% of the et rate, (11 min. 98 see.to 12min, 18 sec) Procedural Instructions for Inspection [Measurement Tine [Deviation Rate % lth Timin [79a [= Tia75 amin [soos a 72000 Tamin [zaasee [3 Tas min [180sec _|-25 He ramin [arse |-2 12250 wamin [73sec [1 12375 min loose |o_ 12500 s2gsce [41 12625 459 sec_| 12 12750 Ba0sec | 13 12825 323s [v4 13000 D7 [+5 13125 Tors | +6 13250 12986 [47 133.75 sas | 5 ers [48 13500 bse | 49 13625 Base [410 13750 esse [+ 13875, a2gse [+2 Va4000 261 AS 1875, Table 8-1 Measurement Examples ‘The inspection and calloration-ifrequired-mustbe performed ‘with the infusion line Vista Pump Set! Role fi 3 a basic purnpis set for the tubingtypeyouare ‘Alternative Measurement Procedure Inspection of the delivery rate with weight measurement. ‘Avoid errors due to evapo ‘Measurement Equipment: - Scales Accuracy 0.1 9. Delivery Rate Determination: sesceeeeseesese Wein = Set the delivery rateto 125 mUh, = Theruin imeis 1- 2 minutes. ~ Insert the outlet cannula in container and simultaneously start stop watch and Vista basic. = After the time has expired stop Vista basic and stop watch. = lenmediately determine the delivery rate. ita 980971 Rew A 5/08 Test Equipment and Special Tools ‘Test Equipment and Special Tools, abe 950971 Rov A508) For Repair / for Technical Safety Inspection (TS) Order No. Pin punch 1.8 mmx 160 mm for hinge pin/disas- sembly of the pump cover) 07701446, Pin punch 6 mmx 125 mm (for hinge pirvassembly (of the pump cover) .......++ eveesene OTTO 1458 ‘Special socket spanner M18 (or disassembly ofthe recessed plugh «++seeese0e rreeteseres O770 1497 IMEC service plug « ++ 34501215 Template22 1m os eeseese sess 0770 5084 Calityation device ....eesseeesesee 0770 S018 Screw driver Torx T6 Screw driver Tore T10 Test Equipment and Special Tools For your notes: aba 850571 RaW A S/04) Spare Parts Unit Elements Designation Mains Fuses Fuse T0315 A for 100/ 110/120 (10 pes) Fuse holder Battery Battery inc. connector plug 124h/7.2 Vand holder... Door Lock ‘Door lock complete with push button. ‘Spring holder for door lock. ‘Mounting for doar lock Pump Cover Pump cover with fock Blin plug 7.1 mem (10 pcs) Torsion spring in lever/purp cover (5 pes) Tessin spring for pump cover (5 ps) Lever (pump cover) Hinge gin for pump cover Hinge pin for pamp cover lever... cso Pump Housing Pumphousing (col) Housing Housing Labeling --..-.seseesssee Foot stand complete with rubber feet. ude fet (20 pes) Unit handle with O-rings and PT screns Power cord fixation Vita bai 950971 Rev 08 Ord. No. = 3477 0534 3450 0979 2450 2556 3450 5601 3450 5440 3477 2790 oo 3450 1916 3077 3207 - 3477 3363 2. 3477 3355 3477 4092 3477 3967 - 34505725 +o 3450 3390 3452 0543 . 34505415 3477 3096 ++ 3450 3450 345200651 Designation Controller Board Distance sleeve. Loudspeaker... Controller board with loudspeaker, volume control and history function, aw material no, 3810 8003 Rear Panel Fear panel with screws (M3) and seal Cover for optical interface Strip seal for rear pane.. MFC connecter board Potential equalization bot rn recessed plug (3 BA) ess eeseeeseee Screw 3038 for fm recessed plug (20 pcs) UWasher 3.2 (20 pes)... Mains module 10071107120 V..- +... Drop sensor socket incl. cable and plug. Front Panel Front pane without comp lever and trsion sing. (Grea seal 571mm /45 x. Taper jroo caps 10 mm (50 ps) Purp hing cpt cover 968 err ‘lam lever with tarsion spring an pin 420 Terson sping feed sensor. Games... 3450 3366 3450 8848 3450 8749 3450 1860 3477 3164 3477 3142 34503374 3477 0550 - 30773177 = 347 3185 3477 3193 3450 1894 = 3450 1878 3480 2092 = 3477 3126, - 3477 3134 - 3450 3390 3450 3412 = 3450 3420 3450 3439 3450 1754 - 3719 9389 Designation Ord. No. Designation Ord. No. Pump Unit Bareode Label Fger pump (without motor including pump, ..... 34520600 arcade label 3450 9670 pump coves, seal membrane and occlusion sensor soe "Onler Farm® pg. A= 2) board Finger pump (without motor and board) 3452 0507 Frame with Seal Indl. pump, purnp coves, Frame with seal plate 34501770 and seal menbrane it Colors Moter with pinion for finger pump... ..--se--s++ 3450 1924 Touch-up pen RAL 8001 (white)... 34500697 Occlusion Sensor ‘Touch-up per RAL 7082 (Gey) «o.+-oseeeseeese1+ 34506985) ‘Occlusion sensor (el). cess 3452 0619. Miscellaneous Air Sensor Assembly screw for display boar Air sensor inl, connector 34501934 PUZSX14 (10S) «oes ceeceeeceeerseerevee 3477 3100 Screw PT'210 Tor (e6forring) ooo... cee e+s 3480 0960 eres Rubber feet ey (20 ps) ee secsecceeeseeseees 3477 3096 Membrane keypad wth suppor late and sea... 34520635 a coniabel Roller Clamp snaie ie 3850 1819 scree 6x8 for fm recessexi plug (20 pes) 3477 3185 Flex cable preformed «--seseeeesereseeeees see, 34508830 y Washer 3.2 20 pes). oeeesseeeeeceesenceeeeees 3A77 HOB, Frame nel pressure spring and ragnet ....+....+, 3450 1835 Fest cable 42 5 Pes) os soeeeesee essen BATT SBA Hinge unit Seoceepeartve erence MFC interface ine 0971 1661 Hinge pin (3 mm) 3450 5580 Magnet soccer eecsceneeeneessee 3450 5849 wa Visa base 980971 Rav (5/04) Appendix ESD Recommendations Semiconductors can be destroyed ty electrostatic discharge. Es: Pecially MOS components can be damaged by interference from ectrostaic fields, even without cischarge ia contact. This type ‘of damage is not immediately recognizable. Unit malfunctions ‘can even occur after 2 longer period of operation. Fvery workstation must be equipped according tothe recamen- ations with the necessary static protective measures, if ESD ‘components or boards are hanced, Workstation ist basic 950971 Rov A108) Each workstation must be equirped with a conductive table sur face. The conductive surface, the soldering icon or the soldering stations must be grounded via protective resistors. Chairs must be of antistatic design. The los loot mats should be of electrically conductive material. Pessonnel must wear conductive wristhands which are connected 10 a central ound potential via protective resistors, eg. the ‘ground contact of a wall outlet. Furthermore itis recommended ‘that personnel wear cotton clothing and electrically conductive shoes to prevent electrostatic charge, QO Vita bake 950971 Rev A 08 Appendix aa Appendix FAX B. Braun Melsungen AG Fax-No: (05661) 75 - 38 09 attn, Mr, Lohr MIT-PR-DEO8C P.0. Box 1120 34209 Melsungen (master) email: ingo.lohr@ bbraun.com Person responsible: .. Tels... Order Barcode Label Order No. 3450 9070 for Vista basic (DIANET-Type-Number 00203) We herewith order the barcode label / type plate with the following serial numbers (the serial number is indicated on the type plate of the pump). Serial Number Serial Number ‘Seva Number SerialNumber We gaurantee that we will fix the barcode label / type plates to the corresponding pumps in accordance with the Service Manual and its enclosures and will carry out the necessary test steps. Barcode labels or type plates that are not required will be destroyed. Date: Signature: ta basie950071 Re 15/0) as oe For your notes: i i i ; j Vita bas 950871 Fev A058) B BRAUN Corporate Headquarters B. Braun Medical Inc. 824 Twelfth Avenue Bethlehem, PA 18018, © 2004 B. Braun Medical Inc. » | isa? base 550571 Rev A (008) |

You might also like