Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

ENDORSEMENT:

1100 4500 (MAX) 1100


8 SHEET OF 10

NOT
H13-250

F DEPTH
H16-100

L OVERBURDEN
H13-200 100mm GAP
2.5x DEPTH (UP TO MAX. 3m) 2.5x DEPTH (UP TO MAX. 3m)

THAN
APPROACH SLAB TO BE PROVIDED APPROACH SLAB TO BE PROVIDED BUILDING AND CONSTRUCTION AUTHORITY

SLAB
WITHIN CARRIAGEWAY ONLY, WITHIN CARRIAGEWAY ONLY, APPROVED UNDER SECTION 5 /SECTION 5A

300
SEE TYP. DETAIL OF APPROACH SLAB SEE TYP. DETAIL OF APPROACH SLAB

I
OF THE BUILDING CONTROL ACT

GREATER
DWG NO. LTA/SDRE14/2/DRA2 TW W TW DWG NO. LTA/SDRE14/2/DRA2 (CHAPTER 29)

RED

500
H13-125

APPROACH

1000m m .
2 LAYERS OF BUILDING PAPER

TREQUI

100
H13-125 H13-125

SOI
6THK NEOPRENE PAD TOP LEVEL 'a' 'c' H16-150 c/c GALVANISED Project Ref. No: E3537-00497-2019-ST005
THROUGHOUT OF DRAIN (1000mm LONG)

W ELL COMPACTED
I

CONCRETE
SUBGRADE

CONCRETE
300

THK
500

THK
(MIN.)

4
23
50m m
'd'

50m m
'b' TW W TW

LEAN

21
LEAN
4T13 100 x 100

20
T13-150 SPLAY BACKFILLED WITH 250 THK GRADED TOP LEVEL OF DRAIN 'a' 'c' GROUND LEVEL
QUARRY DUSTS GRANITE

20
300
AND WELL COMPACTED AGGREGATE BASE

T
COURSE (MIN.)
'e' FOR COMMISSIONER OF BUILDING CONTROL
OR EQUIVALENT
75mm DIA WEEPHOLE
D

'c' EXISTING DRAIN 'b' APPROVED GEOCOMPOSITE


BACKFILLED WITH 'f' @ 1m C/C STAGGERED
SUB-SOIL DRAIN WITH
QUARRY DUSTS GEOCOMPOSITE SUB-SOIL DRAIN MUTI-DIRECTION FLOW
AND WELL COMPACTED C16/20 CONC. TO BE REVETED AT 1.2m C/C POLYMERIC DRAINAGE CORE

1000000
THROUGHOUT LENGTH OF WALL SPOTWELDED ON BOTH
TYPE 'C3'
SIDES TO A NON-WOVEN
PROPOSED INVERT LEVEL HEAT BOUDED GEOTEXTILE
1:30 1:30 (REFER TO LONGITUDINAL TO BE PROPERLY
400

'd' 'e'
SECTION) SECURED ONTO THE WALL
'f'
'h' 'c'

D
75 DIA. WEEPHOLE
C @ 1.0m C/C STAGGERED
B

k'

D1
TYPE 'C3'
SLAB OVER EXISTING DRAIN DETAILS

'

200000
50THK LEAN CONCRETE
C SCALE 1:20 PROPOSED INVERT LEVEL
100THK HARDCORE

400000
NOTES: 1:30 1:30 (REFER TO LONGITUDINAL
SECTION)
LINK 'c' 'g' 1. ALL BEARING CAPACITY: 175kPa
2. LIVE LOAD: 10kPa C16/ 20 CONCRETE
RC SINGLE CELL BOX CULVERT DETAILS 3. EXISTING DRAIN TOP SLAB TEMPORARILY REMOVED IF NECESSARY TO ACHIEVE
FOR APPROVAL TEMPORARY ROAD LEVEL AND REINSTATED AFTER ROAD DIVERSION.

B
SCALE 1:20
C
RC BOX CULVERT NOTE: LIVE LOAD = 25 kPa C 50THK LEAN CONCRETE
DISTANCE FROM Y1 Y1 100THK HARDCORE
BOX CULVERT WIDTH BOX CULVERT DEPTH TW T B 'a' 'b' 'e' 'f' 'g' 'h' DISTRIBUTION OVERBURDEN SHEAR LINKS
'd' BOTTOM SLAB FACE
(W) (mm) (D) (mm) (mm) (mm) (mm) (TOP) (TOP) (WALL) (WALL) (BOT) (BOT) BAR ('c') DEPTH (mm) ('k')
(D1) (mm) 'h' 'g'

<1500 <1500 200 200 200 H13-150 H16-150 H13-150 H16-150 H16-150 H20-150 H16-150 H13-150 <4000 N/A N/A
FOR APPROVAL RC DRAIN DETAILS
<3000 <2500 400 300 400 H13-150 H20-150 H13-150 H16-150 H16-150 H20-150 H20-150 H13-150 <4000 N/A N/A
SCALE 1:20
H13-150 (V)/ 25 Ø
ALUMINIUM RUNG
<4500 <3000 400 400 400 H13-150 H20-150 H16-150 H16-150 H16-150 H20-150 H20-150 H13-150 <4000 500
300 (H) NOTE: LIVE LOAD = 10 kPa C
RC DRAIN
<3500 <2000 350 300 350 H13-150 H20-150 H13-150 H16-100 H16-150 H20-150 H20-150 H13-150 <4000 N/A N/A
DISTANCE FROM
DRAIN WIDTH DRAIN DEPTH TW T B 'a' 'b' 'e' 'f' 'g' 'h' DISTRIBUTION SHEAR LINKS
TW W x W' TW BOTTOM SLAB FACE
(W) (mm) (D) (mm) (mm) (mm) (mm) (TOP) (TOP) (WALL) (WALL) (BOT) (BOT) BAR ('c') ('k')
50 810 (D1) (mm)

B
TOP LEVEL OF DRAIN 'a' 'c' <1500 <1500 200 150 200 N.A. N.A.
H13-150 H13-150 H13-150 H13-150 H16-150 H16-150 H13-150
W, WHERE W > B
<1500 <3000 200 200 200 H13-150 H13-150 H13-100 H13-100 H16-150 H16-150 H13-150 H13-150 (V)/300 (H) 500
T

<4500 250 250 250 H13-150 H13-150 H25-150 H20-150 H20-150 H20-150 H13-150 H13-150 (V)/300 (H) 500
300 <1500
<6000 300 250 300 H13-150 H13-150 H25-100 H25-100 H25-100 H20-150 H13-150 H13-150 (V)/300 (H) 1500
495

'b' WSFR A6 <2000 <2500 250 200 250 H16-150 H16-150 H13-100 H13-100 H20-150 H20-150 H13-150
ALUMINUM RUNGS ARE

5
TO BE PROVIDED AT <2500 <2000 300 250 250 H16-150 H16-100 H16-150 H16-150 H20-125 H20-125 H13-150 N.A. N.A.

15
'e' 115
M.S. GRATING POSITION.

R
WEEPHOLE 45Ø <3000 <2500 350 350 350 H16-100 H16-100 H13-100 H13-100 H20-125 H20-125 H13-150 C
Y1 Y1
75

'c' 'c' (TYP.)


<3000 <3000 350 350 350 H16-100 H16-100 H20-150 H20-150 H20-125 H20-125 H13-150 H13-150 (V)/300 (H) 500
'f'
'f' 'e' PLAN <3500 <3000 350 350 350 H16-100 H16-100 H20-150 H20-150 H20-125 H20-125 H13-150 H13-150 (V)/300 (H) 500
280
TYPICAL SUMP SECTION
300000

APPROVED GEOCOMPOSITE
SUB-SOIL DRAIN WITH NOTES:
MUTI-DIRECTION FLOW POLYMERIC 1) THIS DRAWING IS TO BE READ IN CONJUNCTION WITH LTA's LATEST EDITION OF THE 'STANDARD
DRAINAGE CORE SPOTWELDED ON TYPE C7R SHOWING REINFORCEMENT DETAIL DETAILS OF ROAD ELEMENTS' AND 'ADDENDUM TO THE STANDARD DETAILS OF ROAD ELEMENTS'.
BOTH SIDES TO A NON-WOVEN
SCALE 1:20
HEAT BOUDED GEOTEXTILE TO BE 2) REFER TO LTA/SDRE14/2/DRA6 FOR PC.C. DROP-INLET CHAMBER.
PROPERLY SECURED ONTO THE PRECAST CONCRETE DRAIN

75
D

WALL 200 3) REFER TO LTA/SDRE14/4/GRA2 FOR M.S. PEDESTRAIN GRATING (WITH MILD STEEL PLATE) DETAIL.
SCALE 1:15
23 REFER TO LTA/SDRE14/4/GRA6 AND LTA/SDRE14/4/GRA7 FOR VEHICULAR GRATING.
1000000

NOTES: 0
RIBBED RUNG
4) THE SIZE AND SPACING OF THE GRATINGS REQUIRED SHALL BE BASED ON THE INTERNAL WIDTH
1. CONCRETE GRADE TO BE C25/30.
25 DIA. ROD
2. ALL WEEPHOLES SHALL BE OF 50mm DIA. UNLESS OTHERWISE STATED. OF THE CLOSED DRAIN, AS FOLLOWS:-

200
75mm DIA WEEPHOLE

75
3. 10mm CEMENT MOTAR JOINT SHALL BE PROVIDED BETWEEN THE

90
@ 1m C/C STAGGERED GRATING
PRECAST UNIT THROUGHOUT THE THICKNESS OF THE WALL. INTERNAL WIDTH

4. CASCADE TO BE PROVIDED AT WHERE APPLICABLE. (W)


SIZE SPACING
m'

0
D2

30
'

850mm x 1000mm 50m (STAGGERED)


RIBBED RUNG
200000

GROOVE AT 12m C/C W > 4m


FILLED WITH WHITE RIGID IN ADDITION
PLAN VIEW ISOMETRIC VIEW
500m
400000

POLYVINCHLORIDE 3.5m x 1.8m (OPENING)


'h'
13

CONCRETE BENCHING
WSFR 'e'
(CLOSED-UP VIEW OF RUNG) 850mm x 1000mm 50m (STAGGERED)

2m < W < 4m
IN ADDITION
150

13
500m
B

DETAILS OF NON-SKID ALUMINIUM RUNG 1.5m x 1.5m (OPENING)

50 THK. LEAN CONC. SCALE: 1:10 6m (FOR DRAIN < 1m DEEP)


0.75m < W < 2m 850mm x 1000mm
OR 18m (FOR DRAIN > 1m DEEP)

N)
150 THK. WELL COMPACTED HARDCORE

45 (MI
'g' 'C' DETAILS OF CONSTRUCTION 2H13

0.60m < W < 0.75m 700mm x 850mm 6m


JOINT ON TOP SLAB
RC SUMP DETAILS FOR APPROVAL NOT TO SCALE
SCALE 1:20 NOTE : (i) RUNGS SHALL BE EMBEDDED AT THE DRAIN WALL AT EVERY OPENING / GRATING

NOTE: LIVE LOAD = 25 kPa C FOR CLOSED DRAINS WITH INTERNAL WIDTHS EQUAL TO OR LESS THAN 2m
RC SUMP 2H13
AND MORE THAN 0.9m DEEP IN ACCORDANCE WITH SECTION 9.11.
OPENING
SUMP SIZE (mm) DEPTH DISTANCE FROM
TW T B 'a' 'b' 'e' 'f' 'g' 'h' DISTRIBUTION 2H13 (i) PEDESTRIAN GRATINGS FOR SUMP/DRAIN WITH MILD STEEL PLATE SHALL BE BASED
SHEAR LINKS BOTTOM SLAB FACE
W (mm) (mm) (mm) (TOP) (TOP) (WALL) (WALL) (BOT) (BOT) BAR ('c') ('m') ON LTA/SDRE14/4/GRA2 FOR CLOSED DRAINS WITH INTERNAL WIDTHS LESS THAN OR
W' D (D2) (mm)
EQUAL TO 4.0m.
<1500 <1500 <1500 150 150 150 H13-150 H13-150 H13-150 H13-150 H13-150 H13-150 H13-150 N.A. N.A.
5) UNLESS OTHERWISE STATED, THE GRATING TO THE DROP-INLET CHAMBER, THE DRAIN SUMPS,
<2000 <2000 <3000 250 250 300 H13-100 H13-100 H16-150 H16-150 H16-150 H16-150 H13-150
N.A. N.A. 2H13 THE SAFETY RAILINGS, ETC. WHICH WILL BE HANDED OVER TO DRAINAGE DEPARTMENT SHALL BE
<2250 <3000 <3000 250 250 300 H16-150 H16-150 H16-150 H16-150 H16-150 H16-150 H13-150 HOT-DIPPED GALVANIZED IN ACCORDANCE WITH S.S.117.

<2500 <2500 <4000 300 300 350 H16-150 H16-150 H16-150 H20-150 H16-150 H16-150 H13-150 H13-150 (V)/300 (H) 500 6) MIN. REQUIRED ALLOWABLE BEARING CAPACITY:
2

<3500 <3000 <4000 350 350 350 H16-150 H16-150 H16-150 H16-150 H16-150 H16-150 H13-150 H13-150 (V)/300 (H) 500 ADDITIONAL REINFORCEMENT (BOTTOM) AT FOR DRAIN & SUMP = 75 kN/m
2
FOR DRAIN & SUMP DEPTH > 3m = 125 kN/m
<4200 <5000 <4000 400 400 400 H20-150 H20-150 H20-150 H20-150 H20-150 H20-150 H13-150 H13-150 (V)/300 (H) 500 OPENING FOR INSTALLATION OF GRATING FOR DRAIN & SUMP DEPTH > 4m = 175 kN/m
2

<9000 <9000 <6000 500 400 500 H20-150 H25-150 H20-150 H25-150 H20-150 H20-150 H13-150 H13-150 (V)/300 (H) 1500 NOT TO SCALE FOR BOX CULVERT = 175 kN/m
2
FOR APPROVAL
7) ALL CONCRETE SHALL BE OF GRADE C32/40.

Qualified Person Endorsement: Contractor: Project Title:


ATTACHED X-REFERENCES:

ZN109ACWD-ZZ9001-.dgn

CONTRACT N109A
DESIGN AND CONSTRUCTION OF Drawing Title:

NORTH SOUTH CORRIDOR (TUNNEL) NSC


Consultant:

0.05 0.15
BETWEEN SIN MING AVENUE AND
0 0.1 0.2 0.3 0.4 0.5 Metres ROAD
LTA Endorsement:
ANG MO KIO AVENUE 3
C 10/11/20 TIN REPLY TO WD(EMAIL) FOR E3537-00497-2019-ST005. VSS TKY TCY civil structural geotechnical mechanical electrical
Scale 1:10 TYPICAL DRAIN DETAILS
0 0.15 0.30 0.45 0.60 0.75 Metres B 13/10/20 EYH ISSUE FOR APPROVAL UNDER E3537-00497-2019-ST005. VSS TKY TCY
In Association With:
Architecture Consultant: Designed Checked Approved Drawing No.: Rev. Sheet
A 03/07/20 EYH ISSUE FOR APPROVAL UNDER E3537-00497-2019-ST003. VSS TKY TCY
Scale 1:15
LBS YYY TCY
0 0.5 1.0 Metres - 21/02/20 KEA ISSUED TO PUB FOR APPROVAL. LBS YYY TCY DP ARCHITECTS PTE LTD Z/N109A/RR/DET/0021 C 1 of 1
6 RAFFLES BOULEVARD #04-100 MARINA SQUARE Scale Drawn Date
SINGAPORE 039594 TEL 63383988 FAX 63379989
Scale 1:20 Rev. Date By Description Dsg'd Chk'd App'd AS SHOWN KEA NOV 2019 CAD File Name: ZN109ARR-DET0021C.dgn A1

You might also like