Cal Bearing Without Weight PHT

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 38

Calibration of the Weighing Bearing

using the Handheld PHT


-- without check weights --
this presentation is a standard procedure to calibrate
the weighing bearing for rotor feeders
the shown parameters and calibration figures are examples only
and may be slightly different for each individual plant

for actual parameters please refer to the corresponding


backup files and data sheets
the weighing bearing is NOT available for the coal feeder DRW
the weighing bearing is used for e.g. slow turning feeders
to control the infeed of the rotor
in this way fluctuations of the rotor load may be avoided
the weighing bearing can also be calibrated with check weights
since this weighing device will only control the load in the feeder
small deviations will not influence the accuracy of the feeding system

for calibration with check weights refer to the corresponding presentation


ATTENTION

due to a better overview of a full page display instead of a one line display
it is recommended to use a Laptop and Hyper Terminal
to carry out this calibration
2 additional load cells are installed
between the bearing on the infeed side
and the suspension
to carry out a calibration the following preconditions are required

> feeder must be completely empty

> feeder must not be running

> slide gate between Rotor and silo must be completely closed

> equipment must be in manual or local mode


Pfister Handheld PHT

PHT = Pfister Handheld Terminal


link the PHT to the CSC controller or to the LCB

LCB = Local Control Box

PHT connection at the


CSC controller X17
PHT connection at the
LCB
Pfister-Terminal
899.430.63.00
when the PHT is connected wait until
Vers. 1.2
Ctrl Y > Connect
Ctrl Y > Connect
is being displayed then press key Ctrl
Y to establish communication
if the PHT is connected to the LCB
HAUPTMENU CPI1 press key arrow down until
3 CPI -> Server
Operational 3 CPI -> Server
is being displayed

then press key Enter


to get into the CSC menu

if the PHT is connected to the CSC


skip this page
CSC MAIN MENU
the PHT now will show one of the main
menu lines
X xxxxxx
if not press Ctrl A to get there
CSC MAIN MENU press key arrow down until
7 Configuration
7 Configuration
is being displayed

press key Enter


CONFIGURATION
18.10.2005 11:32
the PHT now will show
1 Syst-Parameter 1 Syst-Parameter

press key Enter


SYSTEM SETTINGS
Entry free
the PHT now will show
<. . . . . . . . . . . . . no Entry free

press key Enter


SYSTEM SETTINGS
Entry free
press key arrow down
<. . . . . . . . . . . . . yes to change to yes

press key Enter


CONFIGURATION
18.10.2005 12:45 press key 0 to go up one directory
1 Syst-Parameter

1 Syst-Parameter
is being displayed now
CONFIGURATION
press key arrow down until
18.10.2005 12:45 A Feeding meas.
A Feeding meas.
is being displayed

press key Enter


MEAS. PARAMET. FM
scroll down with key arrow down
to check if all parameters are still
>> Calibrate
unchanged
MEAS. PARAMET. FM
nom Feedload for nom Feedload in kg and ...
00116,0 kg
MEAS. PARAMET. FM
nom Feedload
... nom Feedload in mV
02,28 mV check the actual data sheet
nom Feedload in kg and mV
when line
MEAS. PARAMET. FM >> Calibrate
>> Calibrate is being displayed again
press key Enter
MC4 amplificat.
+ 063 kg this line indicates the
< . . . . . . . . . . . U 25 current load of the scale
+ 063 kg
MC4 amplificat. check if this parameter is still unchanged
< . . . . . . . . . . . U25

press key arrow down


+ 063 kg
MC4 stage dead 1 check if this parameter is still unchanged
<...........0%

press key arrow down


+ 063 kg New calibration
New calibration
Keys -> Cr,1,C> is being displayed now

press keys Enter 1 Enter


to clear the memory
+ 553 kg
after clearing the memory the
New calibration load indication will show
Keys -> Cr,1,C>
an unrated figure
+ 553 kg
press key arrow down until
Deadload setting Deadload setting
Keys -> Cr,2,C>
is being displayed

press keys Enter 2 Enter


to set the scale to zero
+ 000 kg
Deadload setting
load indication now will show
Keys -> Cr,2,C> + 000 kg
+ 000 kg
press key arrow down until
Calib.-setpoint Calib.-setpoint
000000,0 kg
is being displayed
+ 000 kg
input
Calib.-setpoint 00000,0 kg in Calib.-setpoint
000000,0 kg
see next page
if the input of Calib.-setpoint is 000000,0 kg
+ 000 kg a theoretical calibration is being carried out
Calib.-setpoint
000000,0 kg WITHOUT check weights by using
the parameters
nom Feedload kg and nom Feedload mV
+ 000 kg
press key arrow down
Calibrate Calibrate
Keys -> Cr,3,C>
is being displayed
+ 000 kg
Calibrate press keys Enter 3 Enter
Keys -> Cr,3,C>
to carry out the calibration
+ 000 kg
Calibrate exit this menu by pressing key
Keys -> Cr,3,C>
Ctrl A
CALIBRATION OF THE WEIGHING BEARING
DONE

2008 March 9th

You might also like