Strength Data Attributes
Perfusion (cm3/min)
125
Pullout Comparison 1 • Tactile feedback during transition from 4.5mm HEALIX Ti Torque Capability 1 100
120 cancellous to cortical threads confirms 24
75 128.3
anchor engagement and security 50
100
Pullout Force [lbf]
10
Soft Foam Soft Foam
8 • HEALIX Ti is engineered to engage denser
bone than Arthrex’s Corkscrew FT 1 Hard Foam Hard Foam
6 12
Difference before the force to
4 insert reaches the force of failure
• Increased number of threads provides Suture Bridge
2 4 improved bone contact, purchase & bite
0
5.5mm HEALIX Ti 5.5mm Corkscrew FT*
Suture Abrasion Resistance1
5.5mm HEALIX Ti Torque Capability3
30 1346 Cycles 5.5mm HEALIX Ti
Driver/Anchor Hex Strip Failure - 25.00
25 1171 Cycles 4.5mm HEALIX Ti
Trocar Tip Strength 1
Driver/Anchor Hex Strip - 22.80
300
250
15 169 Cycles FASTIN®RC
200
150 10 21.34 22.00 0 200 400 600 800 1000 1200 1400 1600
Suture Abrasion in Number of Suture Cycles to Break
100
5
50 242 126 82 • Efficient trocar tip designs allows quick &
easy anchor insertion without the need to 5.19 5.14 • ORTHOCORD® Suture now with the
0 0
5.5mm HEALIX Ti 4.5mm HEALIX Ti FASTIN® RC pre-awl, or request additional instruments NEW blue striped 3rd suture
5.5mm HEALIX Ti 5.5mm Corkscrew FT*
- 55 lbs of tensile strength3
- 45% less stiff than Fiberwire**
Mark H. Getelman, M.D. Introduction - For rotator cuff repairs, there are cases where double row techniques can be beneficial, however, the majority of
Triple-Loaded HEALIX Ti Techniques ™ Co-Director Sports Medicine Fellowship
Southern California Orthopedic Institute
cases can be managed well with single row repairs. Several prospective randomized studies have documented equivalent
outcomes with either single or double row repairs4,5,6. In the following, we present different suture options for single row repair.
Technique I Single-Row Rotator Cuff Repair with HEALIX Ti Triple Loaded Anchor Technique III Pyramid Stitch with HEALIX Ti Triple Loaded Anchor
Blue Striped
Blue Blue
Purple
Purple
Blue Striped
through the RC using either a shuttle to the healing site (Crimson Duvet). medial mattress (pass 2,4) and the blue striped medial limb
technique with DePuy Mitek IDEAL™ passed at the apex (most medial) of the triangle as pass 3.
Suture Graspers or an EXPRESSEW® II
device. The three limbs are equidistantly
spaced apart. Once all sutures are passed
they are sequentially tied using a locking
sliding knot and then follow up with three
alternating half hitches.
The blue striped ORTHOCORD is then tied over the top of The second most lateral mattress (purple ORTHOCORD) is lastly
Blue Striped
Blue Purple
Blue Striped
3 the medial mattress as a simple stitch. 4 tied over the top of the simple stitch completing the repair. A
microfracture is then performed laterally on the tuberosity to
stimulate blood flow to the surface (Crimson Duvet).
Blue
Purple
The two blue striped ORTHOCORD® suture A wide lateral horizontal mattress is cre- The two simple stitches are then tied over
1 limbs are passed through the RC as a hori-
zontal mattress with the medial limbs of
2 ated with passes 1 and 4 and the mattress
stitch is then tied first.
3 the mattress stitch. A microfracture is
then performed laterally on the tuberosity
the blue and purple passed more medially to stimulate blood flow to the surface
and between the mattress. Simply, pass 1 is (Crimson Duvet). m mm m
posterior lateral and is the blue striped. 4.5m i 5.5 6.5m
Ti IX
T Ti
Next, pass 2 and 3(purple & blue) are made IX AL IX
as simple passes using more medial limbs AL HE AL
HE HE
closer to the tissue. Pass 4 is blue striped
and that is anterior lateral.
Pascal Boileau M.D.
3
CUFFLOK Surgical Technique
™ Department of Orthopaedic Surgery, Hôpital de L’Archet, Ordering Information
University of Nice, Nice, France
TM
sutures are tensioned deploy anchor. and probe final repair. 222207 5.5mm HEALIX PEEK 3-Suture w/ ORTHOCORD IDEAL™ Suture Shuttle with CHIA™
222219 6.5mm HEALIX PEEK 3-Suture w/ ORTHOCORD 251001 IDEAL Suture Shuttle, 25º Left
251002 IDEAL Suture Shuttle, 25º Right
HEALIX Instruments (For use with HEALIX BR & HEALIX PEEK) 251003 IDEAL Suture Shuttle, 45º Left
222223 HEALIX Awl™ 251004 IDEAL Suture Shuttle, 45º Right
222226 4.5mm HEALIX Cortical Awl/Tap™ 251005 IDEAL Suture Shuttle, 90º Up
222251 5.5mm HEALIX Cortical Awl/Tap 251006 IDEAL Suture Shuttle, Straight Hook
222272 4.5mm HEALIX Full Awl/Tap 251007 IDEAL Suture Shuttle, Straight Crescent
222224 5.5mm HEALIX Full Awl/Tap
222225 6.5mm HEALIX Full Awl/Tap CHIA PERCPASSER™
214101 CHIA PERCPASSER Suture Passer
ROTATOR CUFF R E PA I R S Y S T E M S
*Corkscrew FT is a trademark of Arthrex Inc. Naples FL 5. Grasso A., Milano G., Salvatore M., Falcone G., Deriu L.,
**Fiberwire is a registered trademark of Arthrex, Inc. Naples FL Fabbriciani C., Single-row versus double-row arthroscopic
1. Data on File at DePuy Mitek, Inc. rotator cuff repair: a prospective randomized clinical study.
2. Compared with Arthrex Corkscrew FT Anchor. Arthroscopy. 25(1):4-12, 2009 Jan.
3. Professor Pascal Boileau M.D. et al, The Mattress-Tension-Band (MTB) 6. Franceschi F., Ruzzini L., Longo UG., Martina FM., Zobel BB.,
Technique: A Knotless Double-Row Arthroscopic Rotator Cuff Repair, Shoulder Maffulli N., Denaro V. Equivalent clinical results of arthroscopic
mm II Concepts 2008 Arthroscopy & Arthroplasty, pp 245, 2008 May. single-row and double-row suture anchor repair for rotator
5.5 EW K 4. Burks RT., Crim J., Brown N., Fink B. Greis PE. A prospective randomized cuff tears: a randomized controlled trial. American Journal of
Ti SS LO clinical trial comparing arthroscopic single- and double-row rotator cuff repair: Sports Medicine. 35(8):1254-60, 2007 Aug.
A LIX PR
E SA magnetic resonance imaging and early clinical evaluation. American Journal 7. Castagna A., Garofalo R., Conti M., Borroni M., Snyder SJ.
HE EX V ER of Sports Medicine. 37(4):674-82, 2009 Apr. Arthroscopic rotator cuff repair using a triple-loaded suture
anchor and a modified Mason-Allen technique (Alex stitch).
Arthroscopy. 23(4):440.e1-4, 2007 Apr.