Professional Documents
Culture Documents
NX1100 MSDS
NX1100 MSDS
NX1100 MSDS
fact sheet
Spectrus* NX1100
non-oxidising microbiological control agent
• Effective on a wide spectrum of bacteria, fungi oxidising biocides.
Spectrus NX1100 is applied as a
and algae
disinfectant, fungicide and/or slimicide for
• Controls biofilm formation
commercial and industrial recirculating cooling
water systems. Spectrus NX1100 is EPA registered
• Easy to feed liquid
for use as a disinfectant, fungicide and/or slimicide
• Non-foaming
for commercial and industrial recirculating cooling
• Effective over a wide pH range water systems and industrial once through cooling
water systems. It also controls bacterial, fungal and
description and use algal slimes in air washers and, food and beverage
and industrial process pasteurisers, and influent
Spectrus NX1100 is a proprietary, water based blend of water systems.
non-oxidising biocides which is used to control
microbial populations in open evaporative cooling
treatment and feeding requirements
systems. Spectrus NX1100 is particularly effective
against aerobic bacteria.
Proper treatment levels and frequency of addition of
Spectrus NX1100 depend on many factors, such as
Control of microbial populations in cooling systems is
system cleanliness, microbial species, nutrient
essential in order to prevent biofouling. Biofouling in
concentration, system half-life, and conditions
heat exchangers and cooling tower fill reduces heat
particular to a given installation. The product should
transfer efficiency leading to higher energy costs.
be used in accordance with control procedures that
Biofouling can also damage equipment through
SUEZ establishes for a specific application.
microbiologically influenced corrosion (MIC) and force
unscheduled shutdowns, or extended turnarounds, Equipment recommendations are available upon
resulting in lost production.
request.
E-PFcSpectrusNX1100_EN.docx Nov-05
storage and handling safety precautions
Store Spectrus NX1100 at moderate temperatures and A Material Safety Data Sheet containing detailed
protect from freezing. If frozen, thaw completely and information about this product is available on
mix thoroughly prior to use. request.
Page 2 E-PFcSpectrusNX1100_EN.docx
Version : 2.4
Date of preparation : 26 September 2018
Previous date : 15 July 2016
Emergency telephone
001-803-017-9114 (Indonesia)
+1 703-527-3887 (US)
2. Hazards identification
GHS classification
Physical hazards Corrosive to metals Category 1
Health hazards Acute toxicity, oral Category 4
Acute toxicity, inhalation Category 4
Skin corrosion/irritation Category 1
Serious eye damage/eye irritation Category 1
Sensitization, skin Category 1
Specific target organ toxicity, single exposure Category 1
Specific target organ toxicity, single exposure Category 3 respiratory tract irritation
Environmental hazards Hazardous to the aquatic environment, Category 2
long-term hazard
Label elements
Pictogram
5. Fire-fighting measures
Extinguishing media Water fog. Foam. Dry chemical powder. Carbon dioxide (CO2).
Extinguishing media to avoid Do not use water jet as an extinguisher, as this will spread the fire.
Specific hazards During fire, gases hazardous to health may be formed.
Special fire fighting Use standard firefighting procedures and consider the hazards of other involved materials.
procedures
Protection of fire-fighters Move containers from fire area if you can do so without risk.
Specific methods Use standard firefighting procedures and consider the hazards of other involved materials.
Large Spills: Stop the flow of material, if this is without risk. Dike the spilled material, where this is
possible. Absorb spillage to prevent material damage. Use a non-combustible material like
vermiculite, sand or earth to soak up the product and place into a container for later disposal.
Following product recovery, flush area with water.
Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to
remove residual contamination.
Never return spills to original containers for re-use. For waste disposal, see section 13 of the SDS.
Hygiene measures Keep away from food and drink. Always observe good personal hygiene measures, such as
washing after handling the material and before eating, drinking, and/or smoking. Routinely wash
work clothing and protective equipment to remove contaminants. Contaminated work clothing
should not be allowed out of the workplace.
- COD (mgO2/g) 77