INTRODUCTION
This chapter provides a description of the electrical power system on Citation Mustang
aircraft (Figure 2-1). The DC system consists of storage, generation, distribution, and
system monitoring. Provision is also made for a limited supply of power during emer-
gency conditions in flight and connection of a ground power unit (GPU) while on the
ground.
GENERAL
Direct current provides the principal electri- bus. This arrangement allows either genera-
cal power for the Citation Mustang. Normal tor to power the entire system or, working in
aircraft system voltage is 28.5 VDC. Two gen- parallel, to share the system load.
erators are the primary power sources (one
generator is capable of supplying all standard The battery and emergency buses normally
requirements). Secondary sources (battery or tie to the main system, but they may isolate to
external power) may also be used. only the battery or external power sources.
When the aircraft is on the ground, an exter-
Normal distribution of DC power is via a left nal DC power unit may supply electrical power
and right feed bus connected by a crossfeed to all buses.
510OM-00 2-1
2-2
BATTERY BUS E
EXT PWR BATT M
RELAY T TEMP BATT E
BATT
A AMPS R
SENSOR G
DISC
EMER BUS RELAY P
BATTERY W
RELAY
R
EXT PWR
CONNECTOR AFT J-BOX
C CIRCUIT BREAKERS
AVN EMER B
START SSR LEFT START
RELAY RELAY B BATT
L R U V VOLTS
S
S S
T L AVN EMERG INTERIOR BUS T
BATT
A POWER A
R INT R
L STARTER- T RELAY DISC T R STARTER-
GENERATOR MASTER GENERATOR
# INTERIOR #
1 SSR 1
L NORM R
S L ELE EMERG S
T R ELE EMERG T
A L GEN R GEN A
R L RELAY RELAY R R
T L AVIONICS R AVIONICS #1 R AVIONICS #2 T
L GEN S S R GEN
VOLTS V # H H # V VOLTS
2 U R L U 2
N BOOST L AVN R AVN R AVN BOOST N
T SSR SSR #1 SSR #2 SSR SSR T
B B R AVN EMERG
U U
LEGEND
L SSR #1 BUS BAR R SSR #1 BUS BAR
S S
BATTERY POWER
L DC R DC
AMPS A 200 200 R SSR #2 BUS BAR A AMPS
A MP A MP
GROUND
50 AMP 100 AMP
FLAPS L FEED BUS #1 CROSSFEED BUS R FEED BUS #1
A/C COMP
L ELE #1 L ELE #2 R ELE #2 R ELE #1
50 AMP 100 AMP BATT O’TEMP
HYD PUMP W/S DEICE
100 AMP L FEED BUS #2 R FEED BUS #2 GEN OFF L–R
W/S DEICE STBY INST BATT TEMP FAIL
STANDBY
INST OFF AFT JBOX CB L-R
SWITCH
CITATION MUSTANG OPERATING MANUAL
STANDBY
BATTERY
PACK
L CB R CB
PANEL PANEL
510OM-00
CITATION MUSTANG OPERATING MANUAL
510OM-00 2-3
CITATION MUSTANG OPERATING MANUAL
NORM
2-4 510OM-00
CITATION MUSTANG OPERATING MANUAL
During normal operation, the generators share Before connecting a GPU, ensure that the volt-
loads equally (within ±10% of the total load) via age of the GPU is regulated to 28–29 volts the
the crossfeed bus. Each starter-generator is reg- amperage output between 800 and 1,100 amps.
ulated by its own generator control unit (GCU). When using external power for prolonged
ground operation (over 30 minutes), discon-
Generator power routes from the crossfeed bus nect the battery to preclude overheating the bat-
through the battery relay (when it is closed) to tery. Do not use the battery disconnect switch.
the battery bus. This provides power to charge
the battery, and during generator operation pow- CAUTION
ers the items on the battery bus.
Some GPUs do not have reverse-cur-
Normally (with the battery switch set to rent protection. If the GPU is pow-
e r e d o ff w h i l e c o n n e c t e d t o t h e
BATT), generator power routes from the cross- aircraft, the battery may be rapidly
feed bus through the emergency relay to power discharged and/or damaged. Always
the cockpit emergency buses and through the disconnect the GPU from the air-
battery relay to power the emergency bus in craft when not in use.
the J-box. The battery and emergency relays
are operated with the battery switch.
Connecting the external power source ener-
gizes the external power relay, which con-
GROUND POWER UNIT nects the external power source to the battery
A GPU can be connected to the aircraft DC sys- bus. Setting the battery switch to the BATT po-
tem through a receptacle in the fuselage below sition energizes the battery relay, which allows
the right engine nacelle (Figure 2-4). External the connection of external (or battery) power
power is routed through the external power from the battery bus to the emergency buses,
relay to the battery bus. The battery charges and through the crossfeed bus to the left and
from the GPU, regardless of the battery switch right feed buses.
position.
When either the left or right generator power
A GPU providing a maximum voltage of 29 relay closes, the external power relay deen-
VDC may be used. The left and right start ergizes to remove external power from the
controllers monitor GPU voltage and open the battery bus. This prevents the aircraft gener-
external power relay to disconnect the GPU ators and the GPU from simultaneously ap-
plying power to the aircraft buses.
510OM-00 2-5
CITATION MUSTANG OPERATING MANUAL
CAUTION
If the battery is charged using the
GPU, it must be monitored. Current
from most GPUs is not regulated and
a battery overheat may occur.
DISTRIBUTION
DC power is distributed throughout the aircraft
though several buses (see Figure 2-1) via the
main junction box (aft J-box) and cockpit
buses (behind CB panels).
2-6 510OM-00
CITATION MUSTANG OPERATING MANUAL
510OM-00 2-7
CITATION MUSTANG OPERATING MANUAL
2-8 510OM-00
CITATION MUSTANG OPERATING MANUAL
generator output is within 0.5 volts of nor- cal overload. A list of the protected buses and
mal system voltage (28.5 VDC). components is provided below:
• Left feed bus No. 1—200 amps
When the GCU senses an internal feeder fault
(short circuit) or an overvoltage, the respective • Right feed bus No. 1—200 amps
side generator and field relays open. These re-
• Air-conditioner compressor—100 amps
lays also open when the ENGINE FIRE switch-
light is selected. • Windshield heat (left)—100 amps
• Windshield heat (right)—100 amps
A reverse current (10% of total load) or under-
voltage opens only the generator relay, remov- • Flaps—50 amps
ing the generator from the system but leaving
• Hydraulic powerpack—50 amps
the field relay closed.
• HF radio (optional)—50 amps
The GCU utilizes software and solid-state cir-
cuitry to perform the following operations:
Solid-State Relays
• Control voltage regulation
Solid-state relays (SSRs) serve as a combi-
• Load sharing nation circuit breaker and relay for numerous
• Overvoltage/overexcitation protection components. SSRs are individually controlled
by cockpit system switches or, in some in-
• Automatic generator line contactor stances, by remotely mounted printed circuit
control boards (PCBs).
• Reverse current protection
SSRs are installed in either a 25- or 10-amp size;
• Overload protection however, they are resistor-adjustable for lower
• Overspeed protection amperage trip points. The following buses and
components are SSR-protected and controlled:
• Open ground protection
• Left avionics bus
• Open shunt protection
• Right avionics bus (No. 1)
• Open point of regulation (POR) protection
• Right avionics bus (No. 2)
• Starter cutoff
• Left avionics emergency bus
• Field weakening
• Master interior bus
• Ground fault protection
• Cockpit fan
510OM-00 2-9
CITATION MUSTANG OPERATING MANUAL
NOTE
The battery switch on the DC
POWER subpanel must be in the
Figure 2-7. Battery, Generator, and BATT position for the battery dis-
Ignition Switches connect switch to operate.
2-10 510OM-00
CITATION MUSTANG OPERATING MANUAL
510OM-00 2-11
CITATION MUSTANG OPERATING MANUAL
10 VOLTS Display
1040 PPH 950 5
0
13 °C The left and right generator VOLTS displays
CAS 0 -1 are on the upper-left area of the DC window
GEN OFF L-R 1400 -400 (Figure 2-9). Each VOLTS display indicates
BATT O’TEMP 1330 DEST ELV 8K2
BATT TEMP FAIL 0.8 DIFF PSI
voltage at its respective generator. In rever-
AFT JBOX CB L-R sionary mode, only the digits are displayed.
AFT JBOX LMT L-R 0 5 10
TRIM
AILERON
KANY
RUDDER
FLAPS
UP
TO/APR
LAND
Dual generator failure is annunciated with a Figure 2-9. Electric Display (Normal)
red GEN OFF L-R message and flashing red
MASTER WARNING lights.
AMPS Display
AFT JBOX CB L-R The left and right generator AMPS displays are
An amber AFT JBOX CB L-R message indi- on the upper-right area of the DC window
cates the left or right start circuit breaker on (Figure 2-9). Each display indicates current
the aft J-box has popped. The circuit breaker flow from its respective generator to its re-
cannot be reset from the cockpit. Maintenance spective DC feed bus. During normal opera-
is required. tion, the indication should be parallel within
±10% of total load. Amperage between the
AFT JBOX LMT L-R starter-generator and the battery bus is not re-
An amber AFT JBOX LMT L-R message indi- flected on the AMPS displays. In reversion-
cates failure of a 200-amp current limiter. ary mode, only the digits are displayed.
BATTERY–VOLTS Display
EICAS Display Window
The BATTERY–VOLTS display is a digital
The DC window of the EICAS display provides display on the bottom-center area of the DC
dual generator indications (left and right) for window. The display indicates voltage on the
both voltage (VOLTS) and current (AMPS), battery bus.
and also BATTERY voltage and current.
2-12 510OM-00
CITATION MUSTANG OPERATING MANUAL
510OM-00 2-13
CITATION MUSTANG OPERATING MANUAL
STARTING (ASSISTED BY
EXTERNAL POWER UNIT)
A GPU can be used for engine starts. Check for
voltage regulation to a maximum of 29 VDC
and 800/1,100 amps.
EMERGENCY/
ABNORMAL
For specific information on emergency/abnor-
mal procedures, refer to the appropriate ab-
breviated checklists or the FAA-approved AFM.
2-14 510OM-00