Professional Documents
Culture Documents
Triple W - Shapes
Triple W - Shapes
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Simply Supported Member of Triple W-Shapes Design Based on AISC 13th (AISC 360-05)
ANALYSIS
DETERMINE GOVERNING DESIGN LOADS ON SIGNAL W-SHAPES
Assume conservatively that the perpendiculat W-Shape only supports the H direction bending load, and the torsion load, T, convert to a coupling force on double W-Shapes.
For one of double W-Shapes, W18X65
CHECK COMBINED COMPRESSION AND BENDING CAPACITY OF SINGLE DOUBLE W-SHAPE (AISC 360-05, H1)
P r 8 M rx M ry Pr
, for 0.2
P c 9 M cx M cy Pc
0.67 < 1.0 [Satisfactory]
P r M rx M ry P r 0.2
, for
2 P c M cx M cy Pc
CHECK WEB SHEAR CAPACITY OF SINGLE DOUBLE W-SHAPE (AISC 360-05, G2)
Vnx / Wv = 248.4 / 1.67 = 148.7 kips > Vx = 17.9 kips [Satisfactory]
(cont'd)
CHECK FLANGES SHEAR CAPACITY OF SINGLE DOUBLE W-SHAPE (AISC 360-05, G2)
Vny / Wv = 380.3 / 1.67 = 227.7 kips > Vy = 12.0 kips [Satisfactory]
CHECK COMBINED COMPRESSION AND BENDING CAPACITY OF FITTED STIFF PLATE (AISC 360-05, H1)
P r 8 M rx Pr
, for 0.2
P c 9 M cx Pc
0.74 < 1.0 [Satisfactory]
P r M rx , for P r 0.2
2 P c M cx Pc
ANALYSIS
CHECK LIMITING WIDTH-THICKNESS RATIOS FOR WEB (AISC 365-05 Table B4.1)
hc / tw = 37.56 < lr = 137.27
< lp = 90.55
Compact Web
where E= 29000 ksi
lr = 5.7 (E / Fy)0.5 = 137.27
lp = (hc / hp) (E / Fy)0.5 / (0.54 Mp / My -0.09)2 = 86.51 ,for Af,top ≠ Af,bot
lp = 3.76 (E / Fy)0.5 = 90.55 ,for Af,top = Af,bot
hc = 16.90 in hp = 17.14 in
Mp = 554.2 ft-kips My = 487.5 ft-kips
CHECK LIMITING WIDTH-THICKNESS RATIOS FOR FLANGES (AISC 365-05 Table B4.1)
0.5 bf,top / tf,top = 5.06 < lr = 22.77
< lp = 9.15
Compact Flanges
where lr = 1.0 (kc E / FL)0.5 = 22.77
lp = 0.38 (E / Fy)0.5 = 9.15
kc = Min [0.76 , Max (0.35 , 4 / (h / tw)0.5 )] = 0.63
Sxt = 117 in3 Sxc = 117 in3
FL = 35 ksi, (AISC 360-05 Table note B4.1 & Eq F4-6)
DETERMINE CRITERIA FOR ALLOWABLE FLEXURAL STRENGTH (AISC 365-05 Table F1.1)
Chapter F Sections
Required Conditions F2 F3 F4 F5
Double Symmetric x x
Compact Web x x
x
Noncompact Web
Slender Web Mallowable = Mn / Wb = 311.8 ft-kips
Compact Flanges x ( from following analysis)
Noncompact Flanges
Slender Flanges
Applicable Section ok
E 5.98 ft
L p 1.76 r y
Fy
2
E Jc 0.7 F y S xh 0 E
L r 1.95r ts 1 1 6.76 r ts 18.82 ft
0.7 F y S xh0 E Jc 0.7 F
y
2
C b 2E Jc L b 142.364 ksi
F cr 2
1 0.078
Lb S x h 0 r ts
r ts
M p , for L b L p
Lb L p
M n, F 2 Min C b M p M p 0.7 F y S x
, M p , for L p L b L r
520.7 ft-kips
L
r L p
Min F S
cr x , M p , for L r L b
pf
M p M p 0.7 F y S x , for Noncompact Flanges
rf pf
M n, F 3 618.2 ft-kips
0.9 E k c S x
, for Slender Flanges
2
where l = bf / (2 tf) = 5.06
lpf = lp = 9.15 lrf = lr = 22.77
E 4.50 ft
L p 1.1r t
Fy
2
E J S h
L r 1.95r t 1 1 6.76 F L xc 0 18.87 ft
FL S xc h 0 E J
b fc
rt 2.04 in
1 2
12 h 0 a w h
d 6 h 0d
Mp
, for h c / t w pw
M yc
R pc 1.13675
Min M p M p 1 pw , M p , for h c / t w pw
M yc M yc rw pw M yc
2
C b 2E 1 0.078 J L b
F cr 2 143.076 ksi, (for Iyc / Iy = 0.50 > 0.23, AISC 360-05 F4-5 )
Lb S xc h 0 r t
rt
R pc M yc , for L b L p
Lb L p
M n, F 4.2 Min C b R pc M yc R pc M yc F L S xc , R pc M yc , for L p L b L r
502.3239 ft-kips
L r L p
Min F S
cr xc , R pc M yc , for L r L b
(cont'd)
R pc M yc , for Compact Flanges
pf
R pc M yc R pc M yc F L S xc , for Noncompact Flanges 554.167 ft-kips
M n, F 5.3 rf pf
0.9 E k c S xc
, for Slender Flanges
2
M p
, for h c / t w pw
M yt
R pt 1.13675
Min M p M p 1 pw , M p , for h c / t w pw
M yt M yt rw pw M yt
F y , for L b L p
L b L p
Min C b F y 0.3F y
, F y ,
for L p L b L r
L r L p
45.1678 ksi
F cr , F 5.2
C b 2E
Min 2
, F y , for L r L b
Lb
r
t
Section Left 0.00 S 0.00 S 0.00 S 0.00 S 0.00 S Point 0.17 S 0.33 S 0.50 S 0.67 S 0.83 S Right
Distance 0 0.00 0.00 0.00 0.00 0.00 0.00 5.33 10.67 16.00 21.33 26.67 32.00
d (in) 18 18 18 18 18 18 18 18 18 18 18 18 18
y (in) 9 9 9 9 9 9 9 9 9 9 9 9 9
I (in4) 1068 1068 1068 1068 1068 1068 1068 1068 1068 1068 1068 1068 1068
Wt (plf) 64.6 64.6 64.6 64.6 64.6 64.6 64.6 64.6 64.6 64.6 64.6 64.6 64.6
V (kips) 1.03 1.03 1.03 1.03 1.03 1.03 0.00 -0.69 -0.34 0.00 0.34 0.69 1.03
M (ft-k) 0 0 0 0 0 0 0 5 7 8 7 5 0
(cont'd)
Moments
0
-50
-100
-150
-200
-250
-300
-350
Length
-145.00
-146.00
-147.00
-148.00
-149.00
-150.00
-151.00
Length
5w L 4 0.06415 Pb
L 2 b 2
3/ 2
DL 0.05 in ( L / 7803 )
384 EI EIL (for camber, self Wt included.)
5w L 4 0.06415Pb
L 2b 2
3/ 2
LL 0.00 #DIV/0!
384 EI EIL
w= 1/4 in
wmin = 3/16 in, < w
wmax = 5/16 in, > w
W= 2.0
Vmax = 1.03 kips
Q = Af(d - y - 0.5 tf,top) = 50 in3
vmax = Vmax Q / I = 0.05 kips / in
A= 24 in B
0.6 F EXX 0.707 w A 1832 in. o.c.
v max
USE 1/4 in - 24 in @ 1832 in o.c.
DESIGN STIFFENERS
1. BEARING STIFFENERS ARE REQUIRED AT EACH END SUPPORT. (AISC 360-05, J10.8)
2. CHECK LOCAL WEB YIELDING FOR THE CONCENTRATED LOAD. (AISC 360-05, J10.2)
R=P= 0.00 kips
N= 0 in, bearing length, point.
k = tf,top + w = 1.00 in
W= 1.5
R
, for c d
t w N 5k
0.00 < Fy / W [Satisfactory]
R
, for c d
t w N 2.5 k
(cont'd)
3. CHECK WEB CRIPPLING FOR THE CONCENTRATED LOAD. (AISC 360-05, J10.3)
W= 2.0
1.5
2 N t w EF ywt f , for c 0.5d
0.80t w 13 d
t f tw
Rn / 1 / 125.92 > P [Satisfactory]
1.5
0.40t 2w 13 N t w EF ywt f , for c 0.5d
d t f tw
(Note : If item 2, local web yielding is Satisfactory, this item does not need to be checked.)
4. CHECK SIDESWAY WEB BUCKING FOR THE CONCENTRATED LOAD. (AISC 360-05, J10.4)
dc = d - 2k = 16.40 in
Cr = 960000 ksi
(dc / tw ) / (l / bf) = 2.88
W= 1.76
3 3
C r t wt f 0.4 d c / t w , for d c / t w 1.7
h 2 l / b f l/bf
3
C r t 3wt f
Rn / 1 / 10.4 d c / t w , for 1.7 d c / t w 2.3 0.00 > P [Satisfactory]
h
2 l/b f l/b f
dc / tw
P , for l / 2.3
bf
(Note : If item 2, local web yielding is Satisfactory, this item does not need to be checked.)
tw = 1/4 in , bst = 3 in
R= 1.0 kips
Wc = 1.67 , (AISC 365-05 E1)
Kl/r= 0.75 h / ( I / Aeff)0.5 = 10.6
Cc = 4.71 (E/ Fy)0.5 = 113
2E 2552.83 ksi
Fe
kl / r 2
Fy kl
0.658 F e F y , for Cc
r
R n / c A g / c 116.7 kips, (AISC 360-05 E2)
kl
0.877 F e , for r Cc > R [Satisfactory]
Techincal Reference:
1. AISC: "Steel Construction Manual 13th Edition", American Institute of Steel Construction, 2005.
ROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Plate Girder Design Based on AISC Manual 13th Edition (AISC 360-05)
ANALYSIS
CHECK LIMITING WIDTH-THICKNESS RATIOS FOR WEB (AISC 365-05 Table B4.1)
hc / tw = 43.39 < lr = 137.27
< lp = 90.55
Compact Web
where E= 29000 ksi
lr = 5.7 (E / Fy)0.5 = 137.27
lp = (hc / hp) (E / Fy)0.5 / (0.54 Mp / My -0.09)2 = 40.67 ,for Af,top ≠ Af,bot
lp = 3.76 (E / Fy)0.5 = 90.55 ,for Af,top = Af,bot
hc = 14.97 in hp = 32.30 in
Mp = 554.2 ft-kips My = 487.5 ft-kips
CHECK LIMITING WIDTH-THICKNESS RATIOS FOR FLANGES (AISC 365-05 Table B4.1)
0.5 bf,top / tf,top = 6.23 < lr = 22.03
< lp = 9.15
Compact Flanges
where lr = 1.0 (kc E / FL)0.5 = 22.03
lp = 0.38 (E / Fy)0.5 = 9.15
kc = Min [0.76 , Max (0.35 , 4 / (h / tw)0.5 )] = 0.59
Sxt = 117 in3 Sxc = 117 in3
FL = 35 ksi, (AISC 360-05 Table note B4.1 & Eq F4-6)
DETERMINE CRITERIA FOR ALLOWABLE FLEXURAL STRENGTH (AISC 365-05 Table F1.1)
Chapter F Sections
Required Conditions F2 F3 F4 F5
Double Symmetric x x
Compact Web x x
x
Noncompact Web
Slender Web Mallowable = Mn / Wb = 310.7 ft-kips
Compact Flanges x ( from following analysis)
Noncompact Flanges
Slender Flanges
Applicable Section ok
E 5.98 ft
L p 1.76 r y
Fy
2
E Jc 0.7 F y S xh 0 E
L r 1.95r ts 1 1 6.76 r ts 18.12 ft
0.7 F y S xh0 E Jc 0.7 F
y
2
C b 2E Jc L b 128.666 ksi
F cr 2
1 0.078
Lb S x h 0 r ts
r ts
M p , for L b L p
Lb L p
M n, F 2 Min C b M p M p 0.7 F y S x
, M p , for L p L b L r
518.8 ft-kips
L
r L p
Min F S
cr x , M p , for L r L b
pf
M p M p 0.7 F y S x , for Noncompact Flanges
rf pf
M n, F 3 602.5 ft-kips
0.9 E k c S x
, for Slender Flanges
2
where l = bf / (2 tf) = 6.23
lpf = lp = 9.15 lrf = lr = 22.03
E 4.17 ft
L p 1.1r t
Fy
2
E J S h
L r 1.95r t 1 1 6.76 F L xc 0 17.94 ft
FL S xc h 0 E J
b fc
rt 1.89 in
1 2
12 h 0 a w h
d 6 h 0d
Mp
, for h c / t w pw
M yc
R pc 1.1329
Min M p M p 1 pw , M p , for h c / t w pw
M yc M yc rw pw M yc
2
C b 2E 1 0.078 J L b
F cr 2 126.349 ksi, (for Iyc / Iy = 0.30 > 0.23, AISC 360-05 F4-5 )
Lb S xc h 0 r t
rt
R pc M yc , for L b L p
Lb L p
M n, F 4.2 Min C b R pc M yc R pc M yc F L S xc , R pc M yc , for L p L b L r
493.5636 ft-kips
L r L p
Min F S
cr xc , R pc M yc , for L r L b
(cont'd)
R pc M yc , for Compact Flanges
pf
R pc M yc R pc M yc F L S xc , for Noncompact Flanges 552.289 ft-kips
M n, F 5.3 rf pf
0.9 E k c S xc
, for Slender Flanges
2
M p
, for h c / t w pw
M yt
R pt 1.1329
Min M p M p 1 pw , M p , for h c / t w pw
M yt M yt rw pw M yt
F y , for L b L p
L b L p
Min C b F y 0.3F y
, F y ,
for L p L b L r
L r L p
44.2854 ksi
F cr , F 5.2
C b 2E
Min 2
, F y , for L r L b
Lb
r
t
Section Left 0.00 S 0.00 S 0.00 S 0.00 S 0.00 S Point 0.17 S 0.33 S 0.50 S 0.67 S 0.83 S Right
Distance 0 0.00 0.00 0.00 0.00 0.00 0.00 5.33 10.67 16.00 21.33 26.67 32.00
d (in) 16 16 16 16 16 16 16 16 16 16 16 16 16
y (in) 8 8 8 8 8 8 8 8 8 8 8 8 8
I (in4) 577 577 577 577 577 577 577 577 577 577 577 577 577
Wt (plf) 44.6 44.6 44.6 44.6 44.6 44.6 44.6 44.6 44.6 44.6 44.6 44.6 44.6
V (kips) 0.71 0.71 0.71 0.71 0.71 0.71 0.00 -0.48 -0.24 0.00 0.24 0.48 0.71
M (ft-k) 0 0 0 0 0 0 0 3 5 6 5 3 0
(cont'd)
Moments
-310.656829795621
Length
-97.00
-98.00
-99.00
-100.00
-101.00
Length
5w L 4 0.06415 Pb
L 2 b 2
3/ 2
DL 0.06 in ( L / 6097 )
384 EI EIL (for camber, self Wt included.)
5w L 4 0.06415Pb
L 2b 2
3/ 2
LL 0.00 #DIV/0!
384 EI EIL
w= 1/4 in
wmin = 3/16 in, < w
wmax = 4/16 in, > w
W= 2.0
Vmax = 0.71 kips
Q = Af(d - y - 0.5 tf,top) = 31 in3
vmax = Vmax Q / I = 0.04 kips / in
A= 24 in B
0.6 F EXX 0.707 w A 2328 in. o.c.
v max
USE 1/4 in - 24 in @ 2327.5 in o.c.
DESIGN STIFFENERS
1. BEARING STIFFENERS ARE REQUIRED AT EACH END SUPPORT. (AISC 360-05, J10.8)
2. CHECK LOCAL WEB YIELDING FOR THE CONCENTRATED LOAD. (AISC 360-05, J10.2)
R=P= 0.00 kips
N= 0 in, bearing length, point.
k = tf,top + w = 0.82 in
W= 1.5
R
, for c d
t w N 5k
0.00 < Fy / W [Satisfactory]
R
, for c d
t w N 2.5 k
(cont'd)
3. CHECK WEB CRIPPLING FOR THE CONCENTRATED LOAD. (AISC 360-05, J10.3)
W= 2.0
1.5
2 N t w EF ywt f , for c 0.5d
0.80t w 13 d
t f tw
Rn / 1 / 73.37 > P [Satisfactory]
1.5
0.40t 2w 13 N t w EF ywt f , for c 0.5d
d t f tw
(Note : If item 2, local web yielding is Satisfactory, this item does not need to be checked.)
4. CHECK SIDESWAY WEB BUCKING FOR THE CONCENTRATED LOAD. (AISC 360-05, J10.4)
dc = d - 2k = 14.47 in
Cr = 960000 ksi
(dc / tw ) / (l / bf) = 3.08
W= 1.76
3 3
C r t wt f 0.4 d c / t w , for d c / t w 1.7
h 2 l / b f l/bf
3
C r t 3wt f
Rn / 1 / 10.4 d c / t w , for 1.7 d c / t w 2.3 0.00 > P [Satisfactory]
h
2 l/b f l/b f
dc / tw
P , for l / 2.3
bf
(Note : If item 2, local web yielding is Satisfactory, this item does not need to be checked.)
tw = 1/4 in , bst = 3 in
R= 0.7 kips
Wc = 1.67 , (AISC 365-05 E1)
Kl/r= 0.75 h / ( I / Aeff)0.5 = 8.3
Cc = 4.71 (E/ Fy)0.5 = 113
2E 4137.37 ksi
Fe
kl / r 2
Fy kl
0.658 F e F y , for Cc
r
R n / c A g / c 87.2 kips, (AISC 360-05 E2)
kl
0.877 F e , for r Cc > R [Satisfactory]
Techincal Reference:
1. AISC: "Steel Construction Manual 13th Edition", American Institute of Steel Construction, 2005.
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Rectangular Section Member Design Based on AISC 360-05
ANALYSIS
CHECK BENDING CAPACITY (AISC 360-05, F11)
L bd 0.08E
M p , for 2 F
t y
M n 1 Min 1.52 0.274 L bd F y 0.08 E L bd 1.9 E
Cb 2 E M y , M p , for 2 1.4 ft-kips > Mx
b b t Fy t Fy
L d 1.9 E [Satisfactory]
Min F cr S x , M p , for b2
t Fy
KL E
Q 0.658 F y F e F y , for
Q / 4.71 or F e 0.44QF y
r QF
Pn Ag y
43.7 kips > P
c c KL E
0.877 F e , for r 4.71 QF and F e 0.44QF y [Satisfactory]
y
P r 8 M rx P r 0.2
, for
Pc 9 M cx Pc
0.74 < 1.0 [Satisfactory]
P r M rx , for P r 0.2
2P M Pc
c cx
Where Pr = 12.0 kips Pc = Pn / Wc = 43.7 kips, (AISC 360-05 Chapter E)
Mrx = 0.8 ft-kips Mcx = Mn / Wb = 1.4 ft-kips, (AISC 360-05 Chapter F)