Download as pdf or txt
Download as pdf or txt
You are on page 1of 19

Air System Sizing Summary for Default System

Project Name: Untitled 11/21/2022


Prepared by: Amir 11:09PM

Air System Information


Air System Name Default System Number of zones 1
Equipment Class UNDEF Floor Area 749.0 ft²
Air System Type SZCAV Location Dhahran, Saudi Arabia

Sizing Calculation Information


Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates
Sizing Data Calculated Space CFM Sizing Individual peak space loads

Central Cooling Coil Sizing Data


Total coil load 1.9 Tons Load occurs at Aug 1300
Total coil load 22.8 MBH OA DB / WB 108.4 / 70.2 °F
Sensible coil load 20.0 MBH Entering DB / WB 76.1 / 64.8 °F
Coil CFM at Aug 1300 1084 CFM Leaving DB / WB 59.0 / 57.9 °F
Max block CFM 1084 CFM Coil ADP 57.1 °F
Sum of peak zone CFM 1084 CFM Bypass Factor 0.100
Sensible heat ratio 0.877 Resulting RH 55 %
ft²/Ton 393.7 Design supply temp. 58.0 °F
BTU/(hr-ft²) 30.5 Zone T-stat Check 1 of 1 OK
Water flow @ 10.0 °F rise 4.57 gpm Max zone temperature deviation 0.0 °F

Central Heating Coil Sizing Data


Max coil load 3.9 MBH Load occurs at Des Htg
Coil CFM at Des Htg 1084 CFM BTU/(hr-ft²) 5.2
Max coil CFM 1084 CFM Ent. DB / Lvg DB 70.0 / 73.3 °F
Water flow @ 20.0 °F drop 0.39 gpm

Supply Fan Sizing Data


Actual max CFM 1084 CFM Fan motor BHP 0.00 BHP
Standard CFM 1081 CFM Fan motor kW 0.00 kW
Actual max CFM/ft² 1.45 CFM/ft² Fan static 0.00 in wg

Outdoor Ventilation Air Data


Design airflow CFM 0 CFM CFM/person 0.00 CFM/person
CFM/ft² 0.00 CFM/ft²

Hourly Analysis Program v4.90 Page 1 of 19


Zone Sizing Summary for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

Air System Information


Air System Name Default System Number of zones 1
Equipment Class UNDEF Floor Area 749.0 ft²
Air System Type SZCAV Location Dhahran, Saudi Arabia

Sizing Calculation Information


Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates
Sizing Data Calculated Space CFM Sizing Individual peak space loads

Zone Sizing Data

Maximum Maximum Zone


Cooling Design Minimum Heating Floor
Sensible Airflow Airflow Time of Load Area Zone
Zone Name (MBH) (CFM) (CFM) Peak Load (MBH) (ft²) CFM/ft²
Zone 1 19.7 1084 1084 Jul 1400 3.6 749.0 1.45

Zone Terminal Sizing Data


No Zone Terminal Sizing Data required for this system.

Space Loads and Airflows

Cooling Time Air Heating Floor


Zone Name / Sensible of Flow Load Area Space
Space Name Mult. (MBH) Load (CFM) (MBH) (ft²) CFM/ft²
Zone 1
Bedroom 1 1 3.6 Jul 1300 196 0.7 132.0 1.48
Bedroom 2 1 3.8 Jul 1500 207 0.7 132.0 1.57
kitchen 1 0.8 Jul 1300 45 0.1 36.0 1.26
Living room 1 8.9 Jul 1400 485 1.7 322.0 1.51
Toilet 1 1.0 Jul 1300 55 0.2 50.0 1.09
WIC 1 1 0.9 Jul 1200 52 0.2 42.0 1.23
WIC 2 1 0.8 Jul 1400 44 0.1 35.0 1.27

Hourly Analysis Program v4.90 Page 2 of 19


Ventilation Sizing Summary for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

1. Summary
Ventilation Sizing Method Sum of Space OA Airflows
Design Ventilation Airflow Rate 0 CFM

2. Space Ventilation Analysis Table


Floor Maximum Required Required Required Required Uncorrected
Area Maximum Supply Air Outdoor Air Outdoor Air Outdoor Air Outdoor Air Outdoor Air
Zone Name / Space Name Mult. (ft²) Occupants (CFM) (CFM/person) (CFM/ft²) (CFM) (% of supply) (CFM)
Zone 1
Bedroom 1 1 132.0 2.0 195.8 0.00 0.00 0.0 0.0 0.0
Bedroom 2 1 132.0 2.0 206.7 0.00 0.00 0.0 0.0 0.0
kitchen 1 36.0 1.0 45.5 0.00 0.00 0.0 0.0 0.0
Living room 1 322.0 5.0 485.0 0.00 0.00 0.0 0.0 0.0
Toilet 1 50.0 1.0 54.6 0.00 0.00 0.0 0.0 0.0
WIC 1 1 42.0 1.0 51.6 0.00 0.00 0.0 0.0 0.0
WIC 2 1 35.0 1.0 44.5 0.00 0.00 0.0 0.0 0.0
Totals (incl. Space Multipliers) 1083.6 0.0

Hourly Analysis Program v4.90 Page 3 of 19


Air System Design Load Summary for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

DESIGN COOLING DESIGN HEATING


COOLING DATA AT Aug 1300 HEATING DATA AT DES HTG
COOLING OA DB / WB 108.4 °F / 70.2 °F HEATING OA DB / WB 45.0 °F / 37.8 °F
Sensible Latent Sensible Latent
ZONE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr)
Window & Skylight Solar Loads 27 ft² 1223 - 27 ft² - -
Wall Transmission 1407 ft² 1503 - 1407 ft² 873 -
Roof Transmission 749 ft² 6267 - 749 ft² 2102 -
Window Transmission 27 ft² 467 - 27 ft² 397 -
Skylight Transmission 0 ft² 0 - 0 ft² 0 -
Door Loads 30 ft² 265 - 30 ft² 225 -
Floor Transmission 749 ft² 0 - 749 ft² 0 -
Partitions 1104 ft² 0 - 1104 ft² 0 -
Ceiling 84 ft² 0 - 84 ft² 0 -
Overhead Lighting 1182 W 4032 - 0 0 -
Task Lighting 0W 0 - 0 0 -
Electric Equipment 0W 0 - 0 0 -
People 13 3185 2665 0 0 0
Infiltration - 0 0 - 0 0
Miscellaneous - 0 0 - 0 0
Safety Factor 15% / 5% 2541 133 0% 0 0
>> Total Zone Loads - 19483 2798 - 3596 0
Zone Conditioning - 20029 2798 - 3859 0
Plenum Wall Load 0% 0 - 0 0 -
Plenum Roof Load 0% 0 - 0 0 -
Plenum Lighting Load 0% 0 - 0 0 -
Return Fan Load 1084 CFM 0 - 1084 CFM 0 -
Ventilation Load 0 CFM 0 0 0 CFM 0 0
Supply Fan Load 1084 CFM 0 - 1084 CFM 0 -
Space Fan Coil Fans - 0 - - 0 -
Duct Heat Gain / Loss 0% 0 - 0% 0 -
>> Total System Loads - 20029 2798 - 3859 0
Central Cooling Coil - 20029 2800 - 0 0
Central Heating Coil - 0 - - 3859 -
>> Total Conditioning - 20029 2800 - 3859 0
Key: Positive values are clg loads Positive values are htg loads
Negative values are htg loads Negative values are clg loads

Hourly Analysis Program v4.90 Page 4 of 19


Zone Design Load Summary for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

Zone 1 DESIGN COOLING DESIGN HEATING


COOLING DATA AT Jul 1400 HEATING DATA AT DES HTG
COOLING OA DB / WB 110.3 °F / 70.8 °F HEATING OA DB / WB 45.0 °F / 37.8 °F
OCCUPIED T-STAT 75.0 °F OCCUPIED T-STAT 70.0 °F
Sensible Latent Sensible Latent
ZONE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr)
Window & Skylight Solar Loads 27 ft² 1438 - 27 ft² - -
Wall Transmission 1407 ft² 1602 - 1407 ft² 873 -
Roof Transmission 749 ft² 6129 - 749 ft² 2102 -
Window Transmission 27 ft² 491 - 27 ft² 397 -
Skylight Transmission 0 ft² 0 - 0 ft² 0 -
Door Loads 30 ft² 278 - 30 ft² 225 -
Floor Transmission 749 ft² 0 - 749 ft² 0 -
Partitions 1104 ft² 0 - 1104 ft² 0 -
Ceiling 84 ft² 0 - 84 ft² 0 -
Overhead Lighting 1182 W 4032 - 0 0 -
Task Lighting 0W 0 - 0 0 -
Electric Equipment 0W 0 - 0 0 -
People 13 3185 2665 0 0 0
Infiltration - 0 0 - 0 0
Miscellaneous - 0 0 - 0 0
Safety Factor 15% / 5% 2573 133 0% 0 0
>> Total Zone Loads - 19729 2798 - 3596 0

Hourly Analysis Program v4.90 Page 5 of 19


Space Design Load Summary for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

TABLE 1.1.A. COMPONENT LOADS FOR SPACE '' Bedroom 1 '' IN ZONE '' Zone 1 ''
DESIGN COOLING DESIGN HEATING
COOLING DATA AT Jul 1300 HEATING DATA AT DES HTG
COOLING OA DB / WB 108.4 °F / 70.2 °F HEATING OA DB / WB 45.0 °F / 37.8 °F
OCCUPIED T-STAT 75.0 °F OCCUPIED T-STAT 70.0 °F
Sensible Latent Sensible Latent
SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr)
Window & Skylight Solar Loads 9 ft² 415 - 9 ft² - -
Wall Transmission 267 ft² 258 - 267 ft² 166 -
Roof Transmission 132 ft² 1125 - 132 ft² 370 -
Window Transmission 9 ft² 156 - 9 ft² 132 -
Skylight Transmission 0 ft² 0 - 0 ft² 0 -
Door Loads 0 ft² 0 - 0 ft² 0 -
Floor Transmission 132 ft² 0 - 132 ft² 0 -
Partitions 228 ft² 0 - 228 ft² 0 -
Ceiling 0 ft² 0 - 0 ft² 0 -
Overhead Lighting 198 W 676 - 0 0 -
Task Lighting 0W 0 - 0 0 -
Electric Equipment 0W 0 - 0 0 -
People 2 490 410 0 0 0
Infiltration - 0 0 - 0 0
Miscellaneous - 0 0 - 0 0
Safety Factor 15% / 5% 468 21 0% 0 0
>> Total Zone Loads - 3588 431 - 668 0

TABLE 1.1.B. ENVELOPE LOADS FOR SPACE '' Bedroom 1 '' IN ZONE '' Zone 1 ''
COOLING COOLING HEATING
Area U-Value Shade TRANS SOLAR TRANS
(ft²) (BTU/(hr-ft²-°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr)
E EXPOSURE
WALL 135 0.025 - 137 - 84
WINDOW 1 9 0.588 0.811 156 415 132
N EXPOSURE
WALL 132 0.025 - 121 - 82
H EXPOSURE
ROOF 132 0.112 - 1125 - 370

Hourly Analysis Program v4.90 Page 6 of 19


Space Design Load Summary for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

TABLE 1.2.A. COMPONENT LOADS FOR SPACE '' Bedroom 2 '' IN ZONE '' Zone 1 ''
DESIGN COOLING DESIGN HEATING
COOLING DATA AT Jul 1500 HEATING DATA AT DES HTG
COOLING OA DB / WB 111.0 °F / 71.0 °F HEATING OA DB / WB 45.0 °F / 37.8 °F
OCCUPIED T-STAT 75.0 °F OCCUPIED T-STAT 70.0 °F
Sensible Latent Sensible Latent
SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr)
Window & Skylight Solar Loads 9 ft² 614 - 9 ft² - -
Wall Transmission 267 ft² 359 - 267 ft² 166 -
Roof Transmission 132 ft² 988 - 132 ft² 370 -
Window Transmission 9 ft² 168 - 9 ft² 132 -
Skylight Transmission 0 ft² 0 - 0 ft² 0 -
Door Loads 0 ft² 0 - 0 ft² 0 -
Floor Transmission 132 ft² 0 - 132 ft² 0 -
Partitions 228 ft² 0 - 228 ft² 0 -
Ceiling 0 ft² 0 - 0 ft² 0 -
Overhead Lighting 198 W 676 - 0 0 -
Task Lighting 0W 0 - 0 0 -
Electric Equipment 0W 0 - 0 0 -
People 2 490 410 0 0 0
Infiltration - 0 0 - 0 0
Miscellaneous - 0 0 - 0 0
Safety Factor 15% / 5% 494 21 0% 0 0
>> Total Zone Loads - 3787 431 - 668 0

TABLE 1.2.B. ENVELOPE LOADS FOR SPACE '' Bedroom 2 '' IN ZONE '' Zone 1 ''
COOLING COOLING HEATING
Area U-Value Shade TRANS SOLAR TRANS
(ft²) (BTU/(hr-ft²-°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr)
N EXPOSURE
WALL 132 0.025 - 133 - 82
W EXPOSURE
WALL 135 0.025 - 226 - 84
WINDOW 1 9 0.588 0.811 168 614 132
H EXPOSURE
ROOF 132 0.112 - 988 - 370

Hourly Analysis Program v4.90 Page 7 of 19


Space Design Load Summary for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

TABLE 1.3.A. COMPONENT LOADS FOR SPACE '' kitchen '' IN ZONE '' Zone 1 ''
DESIGN COOLING DESIGN HEATING
COOLING DATA AT Jul 1300 HEATING DATA AT DES HTG
COOLING OA DB / WB 108.4 °F / 70.2 °F HEATING OA DB / WB 45.0 °F / 37.8 °F
OCCUPIED T-STAT 75.0 °F OCCUPIED T-STAT 70.0 °F
Sensible Latent Sensible Latent
SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr)
Window & Skylight Solar Loads 0 ft² 0 - 0 ft² - -
Wall Transmission 48 ft² 49 - 48 ft² 30 -
Roof Transmission 36 ft² 308 - 36 ft² 101 -
Window Transmission 0 ft² 0 - 0 ft² 0 -
Skylight Transmission 0 ft² 0 - 0 ft² 0 -
Door Loads 0 ft² 0 - 0 ft² 0 -
Floor Transmission 36 ft² 0 - 36 ft² 0 -
Partitions 84 ft² 0 - 84 ft² 0 -
Ceiling 0 ft² 0 - 0 ft² 0 -
Overhead Lighting 36 W 123 - 0 0 -
Task Lighting 0W 0 - 0 0 -
Electric Equipment 0W 0 - 0 0 -
People 1 245 205 0 0 0
Infiltration - 0 0 - 0 0
Miscellaneous - 0 0 - 0 0
Safety Factor 15% / 5% 109 10 0% 0 0
>> Total Zone Loads - 834 215 - 131 0

TABLE 1.3.B. ENVELOPE LOADS FOR SPACE '' kitchen '' IN ZONE '' Zone 1 ''
COOLING COOLING HEATING
Area U-Value Shade TRANS SOLAR TRANS
(ft²) (BTU/(hr-ft²-°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr)
E EXPOSURE
WALL 48 0.025 - 49 - 30
H EXPOSURE
ROOF 36 0.112 - 308 - 101

Hourly Analysis Program v4.90 Page 8 of 19


Space Design Load Summary for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

TABLE 1.4.A. COMPONENT LOADS FOR SPACE '' Living room '' IN ZONE '' Zone 1 ''
DESIGN COOLING DESIGN HEATING
COOLING DATA AT Jul 1400 HEATING DATA AT DES HTG
COOLING OA DB / WB 110.3 °F / 70.8 °F HEATING OA DB / WB 45.0 °F / 37.8 °F
OCCUPIED T-STAT 75.0 °F OCCUPIED T-STAT 70.0 °F
Sensible Latent Sensible Latent
SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr)
Window & Skylight Solar Loads 9 ft² 518 - 9 ft² - -
Wall Transmission 633 ft² 716 - 633 ft² 393 -
Roof Transmission 322 ft² 2630 - 322 ft² 904 -
Window Transmission 9 ft² 164 - 9 ft² 132 -
Skylight Transmission 0 ft² 0 - 0 ft² 0 -
Door Loads 30 ft² 278 - 30 ft² 225 -
Floor Transmission 322 ft² 0 - 322 ft² 0 -
Partitions 228 ft² 0 - 228 ft² 0 -
Ceiling 0 ft² 0 - 0 ft² 0 -
Overhead Lighting 644 W 2197 - 0 0 -
Task Lighting 0W 0 - 0 0 -
Electric Equipment 0W 0 - 0 0 -
People 5 1225 1025 0 0 0
Infiltration - 0 0 - 0 0
Miscellaneous - 0 0 - 0 0
Safety Factor 15% / 5% 1159 51 0% 0 0
>> Total Zone Loads - 8887 1076 - 1654 0

TABLE 1.4.B. ENVELOPE LOADS FOR SPACE '' Living room '' IN ZONE '' Zone 1 ''
COOLING COOLING HEATING
Area U-Value Shade TRANS SOLAR TRANS
(ft²) (BTU/(hr-ft²-°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr)
E EXPOSURE
WALL 168 0.025 - 174 - 104
W EXPOSURE
WALL 159 0.025 - 229 - 99
WINDOW 1 9 0.588 0.811 164 518 132
S EXPOSURE
WALL 306 0.025 - 312 - 190
DOOR 30 0.300 - 278 - 225
H EXPOSURE
ROOF 322 0.112 - 2630 - 904

Hourly Analysis Program v4.90 Page 9 of 19


Space Design Load Summary for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

TABLE 1.5.A. COMPONENT LOADS FOR SPACE '' Toilet '' IN ZONE '' Zone 1 ''
DESIGN COOLING DESIGN HEATING
COOLING DATA AT Jul 1300 HEATING DATA AT DES HTG
COOLING OA DB / WB 108.4 °F / 70.2 °F HEATING OA DB / WB 45.0 °F / 37.8 °F
OCCUPIED T-STAT 75.0 °F OCCUPIED T-STAT 70.0 °F
Sensible Latent Sensible Latent
SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr)
Window & Skylight Solar Loads 0 ft² 0 - 0 ft² - -
Wall Transmission 60 ft² 69 - 60 ft² 37 -
Roof Transmission 50 ft² 428 - 50 ft² 140 -
Window Transmission 0 ft² 0 - 0 ft² 0 -
Skylight Transmission 0 ft² 0 - 0 ft² 0 -
Door Loads 0 ft² 0 - 0 ft² 0 -
Floor Transmission 50 ft² 0 - 50 ft² 0 -
Partitions 0 ft² 0 - 0 ft² 0 -
Ceiling 84 ft² 0 - 84 ft² 0 -
Overhead Lighting 38 W 128 - 0 0 -
Task Lighting 0W 0 - 0 0 -
Electric Equipment 0W 0 - 0 0 -
People 1 245 205 0 0 0
Infiltration - 0 0 - 0 0
Miscellaneous - 0 0 - 0 0
Safety Factor 15% / 5% 131 10 0% 0 0
>> Total Zone Loads - 1001 215 - 178 0

TABLE 1.5.B. ENVELOPE LOADS FOR SPACE '' Toilet '' IN ZONE '' Zone 1 ''
COOLING COOLING HEATING
Area U-Value Shade TRANS SOLAR TRANS
(ft²) (BTU/(hr-ft²-°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr)
W EXPOSURE
WALL 60 0.025 - 69 - 37
H EXPOSURE
ROOF 50 0.112 - 428 - 140

Hourly Analysis Program v4.90 Page 10 of 19


Space Design Load Summary for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

TABLE 1.6.A. COMPONENT LOADS FOR SPACE '' WIC 1 '' IN ZONE '' Zone 1 ''
DESIGN COOLING DESIGN HEATING
COOLING DATA AT Jul 1200 HEATING DATA AT DES HTG
COOLING OA DB / WB 105.5 °F / 69.4 °F HEATING OA DB / WB 45.0 °F / 37.8 °F
OCCUPIED T-STAT 75.0 °F OCCUPIED T-STAT 70.0 °F
Sensible Latent Sensible Latent
SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr)
Window & Skylight Solar Loads 0 ft² 0 - 0 ft² - -
Wall Transmission 72 ft² 76 - 72 ft² 45 -
Roof Transmission 42 ft² 357 - 42 ft² 118 -
Window Transmission 0 ft² 0 - 0 ft² 0 -
Skylight Transmission 0 ft² 0 - 0 ft² 0 -
Door Loads 0 ft² 0 - 0 ft² 0 -
Floor Transmission 42 ft² 0 - 42 ft² 0 -
Partitions 168 ft² 0 - 168 ft² 0 -
Ceiling 0 ft² 0 - 0 ft² 0 -
Overhead Lighting 42 W 143 - 0 0 -
Task Lighting 0W 0 - 0 0 -
Electric Equipment 0W 0 - 0 0 -
People 1 245 205 0 0 0
Infiltration - 0 0 - 0 0
Miscellaneous - 0 0 - 0 0
Safety Factor 15% / 5% 123 10 0% 0 0
>> Total Zone Loads - 945 215 - 163 0

TABLE 1.6.B. ENVELOPE LOADS FOR SPACE '' WIC 1 '' IN ZONE '' Zone 1 ''
COOLING COOLING HEATING
Area U-Value Shade TRANS SOLAR TRANS
(ft²) (BTU/(hr-ft²-°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr)
E EXPOSURE
WALL 72 0.025 - 76 - 45
H EXPOSURE
ROOF 42 0.112 - 357 - 118

Hourly Analysis Program v4.90 Page 11 of 19


Space Design Load Summary for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

TABLE 1.7.A. COMPONENT LOADS FOR SPACE '' WIC 2 '' IN ZONE '' Zone 1 ''
DESIGN COOLING DESIGN HEATING
COOLING DATA AT Jul 1400 HEATING DATA AT DES HTG
COOLING OA DB / WB 110.3 °F / 70.8 °F HEATING OA DB / WB 45.0 °F / 37.8 °F
OCCUPIED T-STAT 75.0 °F OCCUPIED T-STAT 70.0 °F
Sensible Latent Sensible Latent
SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr)
Window & Skylight Solar Loads 0 ft² 0 - 0 ft² - -
Wall Transmission 60 ft² 86 - 60 ft² 37 -
Roof Transmission 35 ft² 287 - 35 ft² 98 -
Window Transmission 0 ft² 0 - 0 ft² 0 -
Skylight Transmission 0 ft² 0 - 0 ft² 0 -
Door Loads 0 ft² 0 - 0 ft² 0 -
Floor Transmission 35 ft² 0 - 35 ft² 0 -
Partitions 168 ft² 0 - 168 ft² 0 -
Ceiling 0 ft² 0 - 0 ft² 0 -
Overhead Lighting 26 W 90 - 0 0 -
Task Lighting 0W 0 - 0 0 -
Electric Equipment 0W 0 - 0 0 -
People 1 245 205 0 0 0
Infiltration - 0 0 - 0 0
Miscellaneous - 0 0 - 0 0
Safety Factor 15% / 5% 106 10 0% 0 0
>> Total Zone Loads - 815 215 - 135 0

TABLE 1.7.B. ENVELOPE LOADS FOR SPACE '' WIC 2 '' IN ZONE '' Zone 1 ''
COOLING COOLING HEATING
Area U-Value Shade TRANS SOLAR TRANS
(ft²) (BTU/(hr-ft²-°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr)
W EXPOSURE
WALL 60 0.025 - 86 - 37
H EXPOSURE
ROOF 35 0.112 - 287 - 98

Hourly Analysis Program v4.90 Page 12 of 19


Hourly Air System Design Day Loads for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

DESIGN MONTH: JULY


CENTRAL CENTRAL CENTRAL ZONE
OA SUPPLY COOLING COOLING HEATING PRECOOL PREHEAT TERMINAL TERMINAL HEATING
TEMP AIRFLOW SENSIBLE TOTAL COIL COIL COIL COOLING HEATING UNIT
Hour (°F) (CFM) (MBH) (MBH) (MBH) (MBH) (MBH) (MBH) (MBH) (MBH)
0000 91.4 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0100 90.2 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0200 89.0 1084 15.1 17.9 0.0 0.0 0.0 0.0 0.0 0.0
0300 88.1 1084 14.6 17.4 0.0 0.0 0.0 0.0 0.0 0.0
0400 87.3 1084 13.4 16.2 0.0 0.0 0.0 0.0 0.0 0.0
0500 87.1 1084 13.4 16.1 0.0 0.0 0.0 0.0 0.0 0.0
0600 87.6 1084 14.8 17.6 0.0 0.0 0.0 0.0 0.0 0.0
0700 88.8 1084 15.9 18.7 0.0 0.0 0.0 0.0 0.0 0.0
0800 90.9 1084 17.0 19.8 0.0 0.0 0.0 0.0 0.0 0.0
0900 94.0 1084 17.7 20.5 0.0 0.0 0.0 0.0 0.0 0.0
1000 97.6 1084 17.9 20.7 0.0 0.0 0.0 0.0 0.0 0.0
1100 101.7 1084 19.0 21.8 0.0 0.0 0.0 0.0 0.0 0.0
1200 105.5 1084 19.3 22.1 0.0 0.0 0.0 0.0 0.0 0.0
1300 108.4 1084 19.6 22.4 0.0 0.0 0.0 0.0 0.0 0.0
1400 110.3 1084 19.7 22.6 0.0 0.0 0.0 0.0 0.0 0.0
1500 111.0 1084 19.4 22.2 0.0 0.0 0.0 0.0 0.0 0.0
1600 110.3 1084 18.5 21.3 0.0 0.0 0.0 0.0 0.0 0.0
1700 108.6 1084 17.7 20.5 0.0 0.0 0.0 0.0 0.0 0.0
1800 106.0 1084 15.3 18.1 0.0 0.0 0.0 0.0 0.0 0.0
1900 102.9 1084 14.5 17.3 0.0 0.0 0.0 0.0 0.0 0.0
2000 99.8 1084 14.0 16.8 0.0 0.0 0.0 0.0 0.0 0.0
2100 97.1 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
2200 94.7 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
2300 92.8 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

Hourly Analysis Program v4.90 Page 13 of 19


Hourly Zone Loads for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

ZONE: Zone 1
DESIGN MONTH: JULY
ZONE TERMINAL TERMINAL ZONE
OA ZONE ZONE SENSIBLE ZONE COOLING HEATING HEATING
TEMP TEMP RH AIRFLOW LOAD COND COIL COIL UNIT
Hour (°F) (°F) (%) (CFM) (BTU/hr) (BTU/hr) (BTU/hr) (BTU/hr) (BTU/hr)
0000 91.4 82.8 - 0.0 12578.5 0.0 0.0 0.0 0.0
0100 90.2 82.8 - 0.0 12303.4 0.0 0.0 0.0 0.0
0200 89.0 76.0 64 1083.6 12043.0 15123.4 0.0 0.0 0.0
0300 88.1 75.8 65 1083.6 11804.8 14571.7 0.0 0.0 0.0
0400 87.3 76.1 68 1083.6 11596.3 13409.8 0.0 0.0 0.0
0500 87.1 76.1 68 1083.6 11650.1 13360.8 0.0 0.0 0.0
0600 87.6 75.9 65 1083.6 12800.3 14824.2 0.0 0.0 0.0
0700 88.8 76.0 63 1083.6 14346.7 15891.7 0.0 0.0 0.0
0800 90.9 76.1 60 1083.6 15730.5 16981.9 0.0 0.0 0.0
0900 94.0 76.2 59 1083.6 16902.5 17676.9 0.0 0.0 0.0
1000 97.6 76.5 59 1083.6 17833.4 17946.0 0.0 0.0 0.0
1100 101.7 76.3 57 1083.6 18533.3 18983.7 0.0 0.0 0.0
1200 105.5 76.4 56 1083.6 19109.5 19261.8 0.0 0.0 0.0
1300 108.4 76.4 56 1083.6 19583.6 19629.6 0.0 0.0 0.0
1400 110.3 76.3 55 1083.6 19729.1 19747.5 0.0 0.0 0.0
1500 111.0 76.3 56 1083.6 19430.4 19408.2 0.0 0.0 0.0
1600 110.3 76.3 57 1083.6 18636.1 18545.4 0.0 0.0 0.0
1700 108.6 76.0 59 1083.6 17240.4 17715.0 0.0 0.0 0.0
1800 106.0 76.3 64 1083.6 15567.8 15342.6 0.0 0.0 0.0
1900 102.9 76.3 65 1083.6 14670.1 14502.5 0.0 0.0 0.0
2000 99.8 76.2 66 1083.6 14131.5 14009.2 0.0 0.0 0.0
2100 97.1 82.3 - 0.0 13677.3 0.0 0.0 0.0 0.0
2200 94.7 82.6 - 0.0 13263.0 0.0 0.0 0.0 0.0
2300 92.8 82.7 - 0.0 12894.3 0.0 0.0 0.0 0.0

Hourly Analysis Program v4.90 Page 14 of 19


System Psychrometrics for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

August DESIGN COOLING DAY, 1300

TABLE 1: SYSTEM DATA

Dry-Bulb Specific Sensible Latent


Temp Humidity Airflow CO2 Level Heat Heat
Component Location (°F) (lb/lb) (CFM) (ppm) (BTU/hr) (BTU/hr)
Ventilation Air Inlet 108.4 0.00712 0 400 0 0
Vent - Return Mixing Outlet 76.1 0.01054 1084 3679 - -
Central Cooling Coil Outlet 59.0 0.01000 1084 3679 20029 2800
Central Heating Coil Outlet 59.0 0.01000 1084 3679 0 -
Supply Fan Outlet 59.0 0.01000 1084 3679 0 -
Cold Supply Duct Outlet 59.0 0.01000 1084 3679 - -
Zone Air - 76.1 0.01054 1084 3679 20029 2798
Return Plenum Outlet 76.1 0.01054 1084 3679 0 -

Air Density x Heat Capacity x Conversion Factor: At sea level = 1.080; At site altitude = 1.078 BTU/(hr-CFM-F)
Air Density x Heat of Vaporization x Conversion Factor: At sea level = 4746.6; At site altitude = 4737.2 BTU/(hr-CFM)
Site Altitude = 55.0 ft

TABLE 2: ZONE DATA

Zone Terminal Zone


Sensible Zone Zone Zone CO2 Heating Heating
Load T-stat Cond Temp Airflow Level Coil Unit
Zone Name (BTU/hr) Mode (BTU/hr) (°F) (CFM) (ppm) (BTU/hr) (BTU/hr)
Zone 1 19483 Cooling 20029 76.1 1084 3679 0 0

Hourly Analysis Program v4.90 Page 15 of 19


System Psychrometrics for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

WINTER DESIGN HEATING

TABLE 1: SYSTEM DATA

Dry-Bulb Specific Sensible Latent


Temp Humidity Airflow CO2 Level Heat Heat
Component Location (°F) (lb/lb) (CFM) (ppm) (BTU/hr) (BTU/hr)
Ventilation Air Inlet 45.0 0.00315 0 400 0 0
Vent - Return Mixing Outlet 70.0 0.00000 1084 800 - -
Central Cooling Coil Outlet 70.0 0.00000 1084 800 0 0
Central Heating Coil Outlet 73.3 0.00000 1084 800 3859 -
Supply Fan Outlet 73.3 0.00000 1084 800 0 -
Cold Supply Duct Outlet 73.3 0.00000 1084 800 - -
Zone Air - 70.0 0.00000 1084 800 -3859 0
Return Plenum Outlet 70.0 0.00000 1084 800 0 -

Air Density x Heat Capacity x Conversion Factor: At sea level = 1.080; At site altitude = 1.078 BTU/(hr-CFM-F)
Air Density x Heat of Vaporization x Conversion Factor: At sea level = 4746.6; At site altitude = 4737.2 BTU/(hr-CFM)
Site Altitude = 55.0 ft

TABLE 2: ZONE DATA

Zone Terminal Zone


Sensible Zone Zone Zone CO2 Heating Heating
Load T-stat Cond Temp Airflow Level Coil Unit
Zone Name (BTU/hr) Mode (BTU/hr) (°F) (CFM) (ppm) (BTU/hr) (BTU/hr)
Zone 1 -3596 Deadband -3859 70.0 1084 800 0 0

Hourly Analysis Program v4.90 Page 16 of 19


Hourly Air System Design Day Loads for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

Hourly Analysis Program v4.90 Page 17 of 19


Hourly Zone Design Day Loads for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

Hourly Analysis Program v4.90 Page 18 of 19


Psychrometric Analysis for Default System
Project Name: Untitled 11/21/2022
Prepared by: Amir 11:09PM

Location: Dhahran, Saudi Arabia


Altitude: 55.0 ft.
Data for: August DESIGN COOLING DAY, 1300
0.020
1. Central Cooling Coil Outlet
2. Supply Fan Outlet
3. Room Air
0.018

0.016

Specific Humidity ( lb/lb )


0.014

0.012
3
12
0.010

0.008

0.006

0.004

0.002

0.000
30 40 50 60 70 80 90 100
Temperature ( °F )

Hourly Analysis Program v4.90 Page 19 of 19