Point of ○ Run CPU ● DI120-150

TCD 48 DC Link Low Voltage ( 120-150m/min) Application


Detection ● Speed CPU ○ DI180-420

[Meaning] [Actions to take]

When running is impossible because of DC link charge shortage.


1. Check GP connector in DPP-XXX PCB and VG connector in
DPC-1XX PCB.
[Diagram]
2. Measure the voltage between GX9 and GX17 in
DPP-XXX PCB(Normally,
it should be AC29V. Yet, voltage variation rate is permitted).
2 6 VA-15 VG-15 to ASIC
P15 3. If an error occurs during E/L running,
HIC5 1) Check regeneration initiation voltage(Verify if voltage between
DCP GP-6 8

R24 R25 R26 R27


-
1 GET-E18 7 VA-16 VG-16
9 +
IC1
R23 CH2 and CH3 in DPP-XXX PCB is 7.58).
2) Check DC link condenser(If it is time to replace, replace it).
DCN GP-1
P7 N9 5. Measure power voltage(E/L will operate with 240V or more
R4 R5 DPP-XXX DPC-1XX
power voltage inputted into CP).
6. Verify if regenerative IGBT is in good status.
RCRR c1vd 7. Replace DPP-XXX PCB.
R0 R1
c1st
RCRS c1vd
to IGBT
S0 EMI S1
FILTER c1st

RCRT c1vd
T0 T1

c1st

Check line and condition of


RCRR, RCRS, RCRT