Professional Documents
Culture Documents
Stock Compressor V375 - 50 HZ With Control Panel
Stock Compressor V375 - 50 HZ With Control Panel
Page: 1
MacGregor Germany Tel: +49-4122/711-0 Geschaeftsfuehrer/ Amtsgericht Pinneberg:
Fax: +49-4122/711-104 Managing Director: HRA 0499 EL
GmbH & Co. KG
info@hatlapa.de Rainer Twisterling Verwaltungsgesellschaft: HRB 1560
Tornescher Weg 5-7
www.macgregor.com UST.ID-Nr DE 134527127
25436 Uetersen / Germany
Standard Compressor Features:
• 1st and 2nd Stage Unloading - Automatic via 1st + 2nd Stage solenoid valves
plus manual drain valve
• Flexible Water Hoses (inlet and outlet) - Supplied Loose with threaded
connections
• Condensate Drain Hoses (1st and 2nd stage) - Supplied Loose with Threaded
Connections
Page: 2
MacGregor Germany Tel: +49-4122/711-0 Geschaeftsfuehrer/ Amtsgericht Pinneberg:
Fax: +49-4122/711-104 Managing Director: HRA 0499 EL
GmbH & Co. KG
info@hatlapa.de Rainer Twisterling Verwaltungsgesellschaft: HRB 1560
Tornescher Weg 5-7
www.macgregor.com UST.ID-Nr DE 134527127
25436 Uetersen / Germany
Prime Mover:
• Motor Power 75 kW
• Earthing stud
• Lifting eye
• IP 55 Motor Enclosure
Page: 3
MacGregor Germany Tel: +49-4122/711-0 Geschaeftsfuehrer/ Amtsgericht Pinneberg:
Fax: +49-4122/711-104 Managing Director: HRA 0499 EL
GmbH & Co. KG
info@hatlapa.de Rainer Twisterling Verwaltungsgesellschaft: HRB 1560
Tornescher Weg 5-7
www.macgregor.com UST.ID-Nr DE 134527127
25436 Uetersen / Germany
Typical General Arrangement
Drawings
Page: 4
MacGregor Germany Tel: +49-4122/711-0 Geschaeftsfuehrer/ Amtsgericht Pinneberg:
Fax: +49-4122/711-104 Managing Director: HRA 0499 EL
GmbH & Co. KG
info@hatlapa.de Rainer Twisterling Verwaltungsgesellschaft: HRB 1560
Tornescher Weg 5-7
www.macgregor.com UST.ID-Nr DE 134527127
25436 Uetersen / Germany
~1860
1st stage air 2nd stage air
Inter & final stage Gauge panel pressure gauge; P1 pressure gauge; P2
2nd stage air separation incorporated Compressor
safety valve; SV2 in a common body terminal box; TB
559 ~1193
~185 Terminal box 150 Motor terminal box ~689 ~504
1st stage air
safety valve; SV1
Cooling water
1st stage solenoid/ inlet connection
unloading drain valve; tapped G1 1/4 BSP
tapped G1/2 BSP; Y1
Water sight
~1056
Combined oil glass; FI
Direction
filler/dipstick
Terminal
Air delivery
of rotation
~271
box
200
~710
Water inlet
~485
~368
~311
~276
~321
68
5
64 Water Cooling water outlet 272
2nd stage manual connection
outlet connection drain valve tapped G1 1/4 BSP Water inlet
on 1st stage cylinder ~436 499
2nd stage solenoid/ Magnetic lubricating
116 Water inlet unloading drain valve; Oil level switch; F13 Water outlet Drains oil drain plug
~289 tapped G3/8 BSP; Y2
~439
Auxiliary view showing holding down fastener
745 positions and anti-vibration mount orientation
for machines running at 1500/1800 rpm
1130
Suction filter/ Water jacket safety valve; SV5 Access guard for Lifting eyes to be used together 960
silencer barring over compressor for lifting complete unit
Cooler box
required for servicing
distance 18
required
380
for servicing
26
872
228
182
Motor air inlet
1
R9
380
34
Terminal box
112
Air delivery
338
368
required for servicing
820 min. distance