IXAR-OXY-TOCO-DM-43 Rev. 0
IXAR-OXY-TOCO-DM-43 Rev. 0
IXAR-OXY-TOCO-DM-43 Rev. 0
TABLE OF CONTENTS
Description Page No.
Cover Page 1
Procedure revision status 2
Table of Contents 3
1.0 Purpose 4
2.0 Scope 4
3.0 References 4
4.0 Definitions: 5
5.0 Abbreviations: 5
6.0 Personnel Qualification 5
7.0 Demagnetization Particle Examination Procedure: 6
8.0 Surface Preparation: 6
9.0 Equipment and Consumables 6
10.0 Reason for Demagnetization 7
11.0 Residual Magnetism 7
12.0 Technique/Examination 7
13.0 Acceptance Criteria 8
14.0 Reporting 8
Industrial X-Ray & Allied Radiographers L.L.C.
P.O. Box 3130, P.C.111,CPO, Sultanate of Oman
Tel: +968 22078883, 24541291, Fax:+968 24541281
Email: ixaroman@gmail.com
DEMAGNETIZATION PROCEDURE
Procedure No: IXAR/OXY/TOCO/DM-43 Rev. 0 Page No.: 4 of 8
1.0 Purpose:
All ferromagnetic material will retain some residual magnetism, the strength of which is
dependent on the retentively of the part. Residual magnetism does not affect the
mechanical properties of the part.
A strong residual magnetic field in a part to be welded or electroplated could interfere with
welding or plating process.
The purpose of this procedure is to define the requirement of the demagnetization using AC
electromagnetic yoke for 10” Fuel Gas Line Replacement and CPF Mix Fuel Drum Risk
Reduction#230-231
2.0 Scope:
4.0 Definitions:
Term Definition
Client Occidental Mukhaizna L.L.C.
Contractor The Oman Construction Company L.L.C
A construction contractor is responsible for the day-to-day
oversight of a construction site, management of vendors and
Construction Contractor
trades, and communication of information to involved parties
throughout the course of a project.
Person or entity to whom/which the Contractor subcontracts any
Sub-Contractor
part of the service.
Shall Is to be understood as mandatory.
May be Is to be understood as giving a freedom of choice.
Should Is to be understood as strongly recommended.
5.0 Abbreviations:
The Level III personnel who are qualifying NDT personnel shall pass the ASNT Level III
examination in Basic and MT method which meets the requirements specified in ASNT-SNT-
TC-1A.
Industrial X-Ray & Allied Radiographers L.L.C.
P.O. Box 3130, P.C.111,CPO, Sultanate of Oman
Tel: +968 22078883, 24541291, Fax:+968 24541281
Email: ixaroman@gmail.com
DEMAGNETIZATION PROCEDURE
Procedure No: IXAR/OXY/TOCO/DM-43 Rev. 0 Page No.: 6 of 8
Personnel performing Magnetic particle examination shall have natural or corrected near
distance acuity in at least one eye such that they are capable of reading a minimum of
Jaeger No.1 or equivalent type and size letter at a distance greater than 12”.
And also be capable of distinguishing between colours used during the examination
demonstrated by correctly reading 20 of the 24 plates of Ishihara colour vision test charts.
Demagnetization shall be carried out only after the written procedure is approved by client.
AC Electromagnetic yoke
AC Electromagnetic yoke manufactured by Magnaflux or equivalent shall be used.
Yokes are usually C-shaped which induce a magnetic field between the poles and are used
for local demagnetization.
Many portable yokes have articulated legs that allow the legs to be adjusted to contact
irregular surfaces or two surfaces that join at an angle.
Industrial X-Ray & Allied Radiographers L.L.C.
P.O. Box 3130, P.C.111,CPO, Sultanate of Oman
Tel: +968 22078883, 24541291, Fax:+968 24541281
Email: ixaroman@gmail.com
DEMAGNETIZATION PROCEDURE
Procedure No: IXAR/OXY/TOCO/DM-43 Rev. 0 Page No.: 7 of 8
Gauss Meter
A device that measures magnetic flux density or magnetic induction (a quantity directly related
to magnetic field strength or magnetic force).
The effectiveness of the demagnetizing operation can be indicated by the use of gauss meter.
Residual magnetic field can interfere with electronic equipment such as compass. It can
create a condition known as “arc blow” in the welding process. Arc blow may cause the weld
arc to wonder or filler metal to be repelled from the weld. It can cause abrasive particles to
cling to bearing or faying surfaces and increase wear.
During cleaning operations, chips may adhere to the surface and interfere with subsequent
operations such as painting.
All ferromagnetic materials, after having been magnetized, will retain a residual magnetic field
to some degree. This residual magnetism on the line pipe shall not exceed 20 gauss, as
measured at the pipe ends with Hall Effect gauss meter. Contractor shall ensure that residual
magnetism does not impede welding.
12.0 Technique/Examination:
There are a number of ways of demagnetizing a part, all based on the principle of subjecting
the part to a field continually reversing its direction and at the same time gradually decreasing
in strength to zero (Fig. 1).
The measurement of residual magnetism and demagnetization is done at edge of the pipe or
plate.
Measure and record the residual flux density on the surface to be demagnetized
Place the poles of the AC Yoke on the surface to be demagnetized
Activate it
Moved the pole in a circular pattern
Slowly withdrawn up to 18” from the work piece while the yoke is energized
Repeat the process 3-4 times to demagnetize the part in acceptable limit
Industrial X-Ray & Allied Radiographers L.L.C.
P.O. Box 3130, P.C.111,CPO, Sultanate of Oman
Tel: +968 22078883, 24541291, Fax:+968 24541281
Email: ixaroman@gmail.com
DEMAGNETIZATION PROCEDURE
Procedure No: IXAR/OXY/TOCO/DM-43 Rev. 0 Page No.: 8 of 8
Fig 1: Current and Flux density curves during demagnetization, projected from hysteresis loop
14.0 Reporting:
Report shall be prepared and submitted to the inspection engineer for review and acceptance
as per client format.