Arrêter SIS
Ecran précédent
Conduite et entretien
3512C Generator Set
Numéro d'imprimé -SEBU9095-00 Date de publication -01/11/2012 Date de mise à jour -03/12/2012
i00847451
Moisture and sediment in the air starting system can cause the following conditions:
• Freezing
When opening the drain valve, wear protective gloves, a protective face
shield, protective clothing, and protective shoes. Pressurized air could
cause debris to be blown and result in personal injury.
1. Open the drain valve that is on the bottom of the air tank. Allow the moisture and sediment
to drain.
3. Check the air supply pressure. The air starting motor requires a minimum of 620 kPa (90
psi) of air pressure to operate properly. The maximum air pressure must not exceed 1550
kPa (225 psi). The normal air pressure will be 758 to 965 kPa (110 to 140 psi).