National Accreditation Board for Testing and Calibration Laboratories

Testing Laboratory Preview Report

KERALA HIGHWAY RESEARCH


Name of Laboratory INSTITUTE - TESTING Contact Person Mrs. Sreepriya Lal
LABORATORY
Mobile 9048296869 Email qm@khri.org

Username nabl018426 Application Category Renewal of Accreditation


Accreditation Standard ISO/IEC 17025:2017

Instructions
Information & Instructions for completing an Application Form
1. The applicant CAB shall undertake to carry out its testing activities in such a way as to meet the requirement of ISO/IEC 17025: 2017,
NABLspecific criteria (wherever applicable), other relevant requirements of NABL and the regulatory authorities, as applicable at all times.
CABapplying for accreditation as per ISO/IEC 17025: 2017 shall comply with ‘NABL’s Policies for Accreditation as per ISO/IEC 17025:
2017’.
2. Applicant CABs are advised to ensure that the latest versions of NABL documents are available with them and are implemented.
3. The application fee and other necessary charges related to accreditation process is given in NABL document NABL 100 'General Information
Brochure' under NABL Finance and NABL Fee Structure'. NABL 100 is available on NABL website.
4. CABs are advised to familiarize themselves with NABL 100 ‘General Information Brochure’, NABL 216 ‘Procedures for Dealing with
Adverse Decisions’,NABL 131 ‘Terms and Conditions for Obtaining and Maintaining Accreditation’ and NABL 133 ‘NABL Policy
for Use of NABL Symbol / Claim of Accreditationby Accredited Conformity Assessment Bodies & NABL Accredited CAB Combined ILAC
MRA Mark’ before filling up this form.
5. The applicant CAB shall provide photocopy of following appropriate document(s) in support of the legal status claimed:
i. Proprietorship firm (Copy of Bank Passbook/Account Statement of CAB & ID of Proprietor)
ii. Partnership (Copy of Registration under 1932 Act)
iii. Company Act (Copy of Registration under 1956 Act)
iv. Societies Registration Act (Copy of Registration under 1860 Act)
v. Indian Trust Registration Act ( Copy of Registration under 1882 Act)
vi. Government (Copy of Government Notification/ Declaration etc.
6. The applicant CAB shall intimate NABL about any change in the information provided in this application such as scope applied for accreditation,
personnel, and location etc. within 15 days from the date of changes.
7. NABL expects applicant laboratories that are to be accredited to follow the test methods as mentioned in the current National or International
standards and as stipulated by regulatory bodies. Where such methods do not exist, other validated methods are acceptable. In case CAB uses in-
house validated methods the validation data should be submitted along with the application.
8. The applicant CAB shall participate satisfactorily in the Proficiency Testing (PT) program conducted by APLAC or any other national or
international accredited / recognized PT provider. In cases, where formal accredited / recognized PT programmes are not available, the CAB will
either initiate Inter CAB comparison or participate in appropriate ILC programme conducted by accredited / reputed CAB.For participation in PT,
refer NABL document NABL 163.
9. The CAB shall also inform NABL in advance about any reservation with valid reason regarding appointment of Lead Assessor/ Assessor for the
assessment.
10. The applicant CAB shall be given due notice of any intended changes relating to NABL accreditation criteria and will also be given such time, as in
the opinion of NABL is reasonable to carry out the necessary changes to its policies/practices & procedure(s). The CAB shall inform NABL when
such changes have been completed.
11. The application must be filled up carefully to provide required information in such a manner that further correspondence for seeking clarifications are
not required. Particularly the scope of accreditation shall be complete to indicate unambiguously
a. group of products, materials or items tested
b. specific tests
c. test method Specification against which tests are performed or technique used with year of publication
d. range of testing (as applicable)
e. uncertainty of measurement (MU) for each test (wherever applicable) at a confidence probability of 95%
12. The details of CAB locations and the tests which the CAB intends to cover vide NABL accreditation must be listed clearly. The tests those are
performed at site should be clearly identified in the scope of accreditation.

Note: CAB operates from different locations in the same district may apply for NABL accreditation as a single CAB. The details of each location
shall be explicitly mentioned in application form. In events where the CAB operates from differentdistrict, each CAB shall apply separately for
accreditation except those cases where safety or regulatory requirements are there for operation of the CAB. In such cases, the CAB shall provide
the proper justification.

13. The CAB shall offer the NABL or its representative cooperation in:
a. undertaking any check to verify testing capability of the CAB.
b. the CAB shall unambiguously provide names of all authorized signatories who are responsible for authenticity and issue of test certificates and
reports.
c. offering access to relevant areas of the CAB for witnessing the test being performed.
d. examination of all relevant documentation and records.
e. interaction with all relevant personnel.
14. The CAB shall take all necessary actions and discharge all non- conformities raised during the assessment within the stipulated time.The same shall
be verified to the satisfaction of NABL. The final decision on accreditation shall rest with NABL.
15. The proposed personnel for review, report and release of test results shall meet the minimum qualification and experience requirements as
mentioned below:

16. The application shall be kept confidential (until required by law) by NABL and information obtained during the processing of application,
assessment visit and grant of accreditation shall be safeguarded and dealt with impartiality. The procedure for processing of application for
accreditation is given in NABL 100.
I have read the aboveinformation and instructions.

Lab General Details


Details Data Feeded by Lab
KERALA HIGHWAY RESEARCH INSTITUTE - TESTING
Name of the Laboratory
LABORATORY
Type of Laboratory Public
GSTIN 32AAAGK0610D1ZB
Country India
State/Province Kerala
City Thiruvananthapuram
Landline 0471-2418689
Does the laboratary operate from different locations having same
No
legal identity within the city
Are you from SEZ region(Special economic zone) No
Whether any individual or organization has provided consultancy for
Yes
preparing towards NABL Accreditation
Name of Individual/organization with city Vivek Tewari of QMAC MANAGEMENT CONSULTANTS
Whether any adverse action has been initiated/taken by NABL
No
against the laboratory in the past years.
Contact Person for NABL
Name Mrs. Sreepriya Lal
Designation Quality Manager
Mobile No 9048296869
Landline No 0471-2418689
Fax -
Email qm@khri.org
Category of Facility(s) Applied Under the Scope of Accreditation
Permanent Facility Yes
Site Facility Yes
Mobile Facility No
Parent Organisation Details
Name of the Parent Organization Applicable? Yes
Name of Parent Organization Public Works Department, Government of Kerala
Mobile No
Landline No 0471-2325856
Fax No. -
E-mail cedriq.pwd@kerala.gov.in
Legal Identity Details
Legal Identity Name KERALA HIGHWAY RESEARCH INSTITUTE
Legal Identity Type Government Organization
Government Organization Certificate Download
Type of Laboratory by Service Partly Open to Others
Other Accreditations
Internal Audit and Management Review
Start Date of Last Internal Audit 10-11-2021
End Date of Last Internal Audit 12-11-2021
Whether all requirements of ISO/IEC 17025:2017covering all
activities of laboratory have been audited at least once in last one Yes
year
Start Date of Last Management Review 16-11-2021
End Date of Last Management Review 16-11-2021
File Uploads
Organization Chart of laboratory Download
Organization chart indicating relation to its parent organization Download
System Document File Download

Disciplines
Sr No. Discipline Name Group Name
1 Mechanical Buildings Materials
2 Mechanical Soil and Rock
3 Non-destructive Building Materials - Reinforced Concrete Structures

Lab Location Details


Details Data Feeded by Lab
KHRI -CAMPUS, KARYAVATTOM,
Address
THIRUVANANTHAPURAM
District
City Thiruvananthapuram
Pin Code 695581
Contact No 9447341237
Fax No. -
E-mail qm@khri.org

Proposed Scope
Range of
S. Product/Material of Specific Test (±)MU
Test method Testing/Limit of Test Performed at
No test Performed @Value
detection
Discipline: Mechanical Group: Buildings Materials
Aggregate Impact 2.00 % @
1 Coarse Aggregate IS 2386: Part 4: 1963 3 % to 60 % PermanentFacility
Value 24.00 %
0.027 kg/l
2 Coarse Aggregate Bulk Density (Loose) IS 2386: Part 3: 1963 1 kg/l to 3 kg/l @ 1.414 PermanentFacility
kg/l
0.02 kg/l
3 Coarse Aggregate Bulk density (Rodded) IS 2386: Part 3: 1963 1 kg/l to 3 kg/l @ 1.56 PermanentFacility
kg/l
2.973 % @
4 Coarse Aggregate Elongation Index IS 2386: Part 1: 1963 1 % to 60 % PermanentFacility
36.464 %
2.241 % @
5 Coarse Aggregate Flakiness Index IS 2386: Part 1: 1963 1 % to 60 % PermanentFacility
18.240 %
Los Angeles Abrasion 1.88 % @
6 Coarse Aggregate IS 2386: Part 4: 1963 1 % to 60 % PermanentFacility
Test 32.33 %
Sieve Analysis 1 % @ 21
7 Coarse Aggregate IS 2386: Part 1: 1963 0.1 % to 100 % PermanentFacility
(75micron to 80mm) %
0.04@
8 Coarse Aggregate Specific Gravity IS 2386: Part 3: 1963 1to 3 PermanentFacility
2.71
0.15 % @
9 Coarse Aggregate Water Absorption IS 2386: Part 3: 1963 0.1 % to 2 % PermanentFacility
0.50 %
0.03 kg/l
10 Fine Aggregate Bulk Density (Loose) IS 2386: Part 3: 1963 1 kg/l to 3 kg/l @ 1.56 PermanentFacility
kg/l
0.03 kg/l
11 Fine Aggregate Bulk density (Rodded) IS 2386: Part 3: 1963 1 kg/l to 3 kg/l @ 1.78 PermanentFacility
kg/l
Sieve Analysis (75 5 % @ 65
12 Fine Aggregate IS 2386: Part 1: 1963 75 micron to 10 mm PermanentFacility
micron to 10 mm) %
0.08@
13 Fine Aggregate Specific Gravity IS 2386: Part 3: 1963 1to 3 PermanentFacility
2.50
0.30 % @
14 Fine Aggregate Water Absorption IS 2386: Part 3: 1963 0.1 % to 2 % PermanentFacility
1.59 %
100.61
1000 Poise to 6000 Poise @
15 Bitumen Absolute Viscosity IS 1206: Part 2: 1978 PermanentFacility
Poise 3535.87
Poise
0.27 % @
16 Bitumen Binder Content ASTM D 2172: 2017 2 % to 20 % PermanentFacility
3.28 %
4.66 cm @
17 Bitumen Ductility IS 1208: 1978 20 cm to 100 cm PermanentFacility
79.44 cm
4.5
10 divisions to 100
18 Bitumen Penetration IS 1203: 1978 divisions @ PermanentFacility
divisions
40 divisions
30 °C 2 °C @
19 Bitumen Softening Point IS 1205: 1978 PermanentFacility
to 70 °C 54 °C
0.02@
20 Bitumen Specific Gravity IS 1202: 1978 0.98to 1.06 PermanentFacility
1.026
12.000 cSt
Viscosity –
21 Bitumen IS 1206: Part3: 1978 200 cSt to 600 cSt @ 548.558 PermanentFacility
Kinematic
cSt
0.56
2
1 N/mm to 35 N/mm2 @
22 Bricks Compressive Strength IS 3495: Part 1: 2019 PermanentFacility
N/mm2 11.70
N/mm2
23 Bricks Efflorescence IS 3495: Part 3: 2019 Qualitative PermanentFacility
0.44 % @
24 Bricks Water Absorption IS 3495: Part 2: 2019 1 % to 30 % PermanentFacility
10.8 %
2.71 Mpa
25 Paver Block Compressive Strength IS 15658: 2021 10 Mpa to 100 Mpa @ 48.9 PermanentFacility
Mpa
0.39 % @
26 Paver Block Water Absorption IS 15658: 2021 1 % to 30 % PermanentFacility
4.4 %
0.64
2
1 N/mm to 35 N/mm2 @
27 Solid Blocks Compressive Strength IS 2185: Part 1: 2005 PermanentFacility
N/mm2 10.7
N/mm2
0.65 % @
28 Solid Blocks Water Absorption IS 2185: Part 1: 2005 1 % to 30 % PermanentFacility
6.40 %
1.25 MPa
29 Cement Compressive Strength IS 4031: Part 6: 1988 10 MPa to 70 MPa @ 44.5 PermanentFacility
MPa
0.04 gm/cc
30 Cement Density IS 4031: Part 11: 1988 2 gm/cc to 4 gm/cc @ 2.92 PermanentFacility
gm/cc
11.52 min
31 Cement Final Setting Time IS 4031: Part 5: 1988 30 min to 600 min @ 282.0 PermanentFacility
min
0.16 % @
32 Cement Fineness by dry sieving IS 4031: Part 1: 1996 0.5 % to 10 % PermanentFacility
1.8 %
8.98 min @
33 Cement Initial Setting Time IS 4031: Part 5: 1988 30 min to 500 min PermanentFacility
141.0 min
0.32 mm
Soundness (Le-
34 Cement IS 4031: Part 3: 1988 0.1 mm to 10 mm @ 1.50 PermanentFacility
Chatlier Method)
mm
0.74 % @
35 Cement Standard Consistency IS 4031: Part 4: 1988 25 % to 40 % PermanentFacility
30.4 %
2.16
2
5 N/mm to 80 N/mm2 @
36 Concrete Cores Compressive Strength IS 516: Part 4: 2018 PermanentFacility
N/mm2 26.0
N/mm2
1.42 Mpa
IS 516 (Part 1/Sec 1):
37 Concrete Cube Compressive Strength 5 Mpa to 80 Mpa @ 31.0 PermanentFacility
2021
Mpa
Reinforcement Steel 0.74 % @
38 Elongation percent IS 1608: Part 1: 2018 5 % to 40 % PermanentFacility
Bars 18.6 %
0.006 kg/m
Reinforcement Steel
39 Mass Per Meter IS 1786: 2008 0.1 kg/m to 10 kg/m @ 2.41 PermanentFacility
Bars
kg/m
12.96 MPa
Reinforcement Steel Ultimate Tensile
40 IS 1608: Part 1: 2018 100 MPa to 900 MPa @ 653 PermanentFacility
Bars Strength
MPa
10.75 MPa
Reinforcement Steel 100 MPa
41 Yield Stress IS 1608: Part 1: 2018 @ 555 PermanentFacility
Bars to 900 MPa
MPa
Discipline: Mechanical Group: Soil and Rock
1.1 % @
42 Soil CBR (Soaked) IS 2720: Part 16: 1987 0 % to 150 % PermanentFacility
11.3 %
0.9 % @
43 Soil CBR - Unsoaked IS 2720: Part 16: 1987 0 % to 150 % PermanentFacility
13.7 %
Consolidation - IS 2720: Part 15 : 0.013@
44 Soil 0.01to 2.0 PermanentFacility
Compression Index 1986 0.277
Consolidation - Initial IS 2720: Part 15 : 0.01@
45 Soil 0.01to 3.0 PermanentFacility
Void Ratio 1986 0.88
0.45 % @
46 Soil Free Swell Index IS 2720: Part 40: 1977 0 % to 200 % PermanentFacility
10.00 %
Grain Size Analysis- by
2.17 % @
47 Soil Dry Sieving (75 IS 2720: Part 4: 1985 0.1 % to 100 % PermanentFacility
47.07 %
micron- 75mm)
Grain Size Analysis- by
Hydrometer Analysis 2.5 % @
48 Soil IS 2720: Part 4: 1985 0.1 % to 100 % PermanentFacility
(0.2 micron to 75 37.8 %
micron)
Grain Size Analysis- by
4.83 % @
49 Soil Wet Sieving (75 IS 2720: Part 4: 1985 0.1 % to 100 % PermanentFacility
70.82 %
micron to 75mm)
0.08 g/cc
Heavy
50 Soil IS 2720: Part 8: 1983 1 g/cc to 2.9 g/cc @ 1.96 PermanentFacility
Compaction(MDD)
g/cc
Heavy 0.83 % @
51 Soil IS 2720: Part 8: 1983 6 % to 50 % PermanentFacility
Compaction(OMC) 11.60 %
0.07 g/cc
Light
52 Soil IS 2720: Part 7: 1980 1.0 g/cc to 2.9 g/cc @ 1.88 PermanentFacility
Compaction(MDD)
g/cc
Light 0.71 % @
53 Soil IS 2720: Part 7: 1980 6.00 % to 50.00 % PermanentFacility
Compaction(OMC) 13.50 %
Liquid Limit IS 2720: Part 5: 1985
2 % @ 42
54 Soil (Casagrande RA 2020 Clause 3 & 5 % to 200 % PermanentFacility
%
Apparatus) 5: 1985
Liquid Limit - Cone
IS 2720: Part 5: 2 % @ 36
55 Soil Penetrometer 5 % to 100 % PermanentFacility
Clause 4 & 6: 1985 %
Apparatus
0.57 % @
56 Soil Moisture Content IS 2720: Part 2: 1973 0.1 % to 150 % PermanentFacility
18.70 %
0.000560
Permeability - 0.001 cm/s to cm/s @
57 Soil IS 2720: Part 17: 1987 PermanentFacility
Constant Head 0.0000001 cm/s 0.00755
cm/s
0.0004
Permeability - Falling 0.001 cm/s to cm/s @
58 Soil IS 2720: Part 17: 1986 PermanentFacility
Head 0.0000001 cm/s 0.00755
cm/s
2 % @ 31
59 Soil Plastic Limit IS 2720: Part 5: 1985 5 % to 150 % PermanentFacility
%
3 % @ 23
60 Soil Shrinkage Limit IS 2720: Part 6: 1972 5 % to 50 % PermanentFacility
%
0.03@
61 Soil Specific Gravity IS 2720: Part 3: 1980 1.00to 3.00 PermanentFacility
2.61
16.85 KPa
Unconfined
62 Soil IS 2720: Part 10: 1991 5 KPa to 1000 KPa @ 271.96 PermanentFacility
Compressive Strength
KPa
Discipline: Non-destructive Group: Building Materials - Reinforced Concrete Structures
3.15 mm
63 Concrete Structure Carbonation Test BS EN 14630: 2006 1 mm to 75 mm @ 35.36 SiteFacility
mm
2.76 mm
BS 1881 Part 204:
64 Concrete Structure Cover Meter Test 10 mm to 70 mm @ 43.06 SiteFacility
1988
mm
-30.57 mV
Half Cell Potential
65 Concrete Structure ASTM C876: 2015 -100 mV to -700 mV @ -296.6 SiteFacility
difference test
mV
ASTM C805/C805M: 2.81 Q @
66 Concrete Structure Rebound Hammer Test 10 Q to 70 Q SiteFacility
2018 40.74 Q
IS 516: Part 5: Sec 4: 2.72 Q @
67 Concrete Structure Rebound Hammer Test 10 Q to 70 Q SiteFacility
2020 40.10 Q
0.072 km/s
Ultrasonic Pulse IS 516: Part 5/section
68 Concrete Structure 1 km/s to 5 km/s @ 3.440 SiteFacility
Velocity Tests 1: 2018
km/s

Organisation Details
Details Data Feeded by Lab
Discipline: Mechanical
Group:
Employee Type Others
Name Ms.-ASWATHY S S
Designation Technical Supervisor FP
Qualification M.Tech
Specialization Geo-informatics
Experience in Years Related to Present Work 3
Awareness Training programme on ISO 17025:2017 Training on
Relevant Technical Training
mix design of concrete as per IS 10262:2019
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible for Testing of Aggregate and Bitumen
Employee Type Others
Name Ms.-Beena M
Designation Technical Supervisor CSE
Qualification ITI
Specialization Civil
Experience in Years Related to Present Work 3
Relevant Technical Training Awareness training program on ISO17025:2017
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible of Building Material Testing
Employee Type Others
Name Mr.-Mr. LIJIN KUMAR J L
Designation Technical Supervisor FP
Qualification KGCE
Specialization Civil
Experience in Years Related to Present Work 5
Awareness Training programme on ISO 17025:2017, 2 days
Relevant Technical Training
training on Measurement uncertainty calculation
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Testing of bitumin and aggregate samples.
Employee Type Others
Name Mr.-Jinu Mohan M
Designation Technical Supervisor CS
Qualification B.Tech
Specialization Civil Engineering
Experience in Years Related to Present Work 3
Awareness Training programme on ISO 17025:2017.2 days
Relevant Technical Training
Training on Uncertainity Calculation
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible for testing of Building Material
Employee Type Others
Name Ms.-Rasheeda Beevi L
Designation Technical Supervisor SMF
Qualification ITI
Specialization Civil
Experience in Years Related to Present Work 10
Awareness Training programme on ISO 17025:2017, On Job
Relevant Technical Training
Training on testing of Soil -KHRI
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible of Testing of Soil
Employee Type Others
Name Mr.-SAJEEVL P
Designation Technical Supervisor FP
Qualification KGCE
Specialization Civil
Experience in Years Related to Present Work 10
Relevant Technical Training Awareness Training programme on ISO 17025:2017
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible for Testing of Aggregate & Bitumen
Employee Type Others
Name Mr.-Suseel K S
Designation Technical Supervisor CS
Qualification Diploma
Specialization Civil Engineering
Experience in Years Related to Present Work 4
4 days Training on ISO 17025 : 2017, 2 days training on
Relevant Technical Training
Uncertainty Calculation, Training on building material testing
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible of Building Material Testing
Employee Type Others
Name Ms.-Rehana I
Designation Technical Supervisor CS
Qualification Diploma
Specialization Civil Engineering
Experience in Years Related to Present Work 4
4 days Training on ISO 17025 : 2017 , Training on building
Relevant Technical Training
material testing
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible for testing of Building Material
Employee Type Others
Name Ms.-Syama Mohanan M S
Designation Technical Supervisor CS
Qualification Diploma
Specialization Civil Engineering
Experience in Years Related to Present Work 4
4 days Training on ISO 17025 : 2017 , Training on building
Relevant Technical Training
material testing
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible for testing of Building Material
Employee Type Others
Name Ms.-Nisha. K. S.
Designation Technical Supervisor SMF
Qualification B.Tech
Specialization Civil engineering
Experience in Years Related to Present Work 5
Awareness Training on ISO 17025 : 2017 Onjob Training on
Relevant Technical Training
testing of Soil -KHRI, 2 days training on Uncertainty Calculation
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible of Testing of Soil
Employee Type Others
Name Mr.-Shiju. S.
Designation Technical Supervisor SMF
Qualification Diploma
Specialization Civil engineering
Experience in Years Related to Present Work 5
Awareness Training on ISO 17025 : 2017 Onjob Training on
Relevant Technical Training
testing of Soil -KHRI
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible of Testing of Soil
Employee Type Others
Name Ms.-Latha P
Designation Technical Supervisor SMF
Qualification Diploma
Specialization Civil engineering
Experience in Years Related to Present Work 12
4 days Training on ISO 17025 : 2017On Job Training on testing of
Relevant Technical Training
Soil -KHRI
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible of Testing of Soil
Employee Type Others
Name Ms.-Lerrishya K
Designation Technical Supervisor SMF
Qualification ITI
Specialization Civil
Experience in Years Related to Present Work 3
Awareness Training on ISO 17025 : 2017Onjob Training on Soil
Relevant Technical Training
TestingKHRI
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible for Testing of Soil
Employee Type Others
Name Mr.-NIZAR S
Designation Technical Supervisor CS
Qualification B.Tech
Specialization Civil engineering
Experience in Years Related to Present Work 5
Training on ISO 17025Training on mix design of high strength
Relevant Technical Training
concrete -KHRI
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible for Testing of Building Materials and NDT parameters.
Employee Type Others
Name Mr.-SARATH S
Designation Technical Supervisor CS
Qualification Diploma
Specialization Civil engineering
Experience in Years Related to Present Work 5
Training on ISO 17025 Training on mix design of high strength
Relevant Technical Training
concrete -KHRI
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible for Testing of Building Materials
Discipline: Mechanical
Group: Buildings Materials,Soil and Rock
Employee Type Person responsible for management system
Name Ms.-Lekshmi Subhash
Designation Deputy Lab Head SMF
Qualification M.Tech
Specialization Environmental Engineering
Experience in Years Related to Present Work 10
4 days Training on ISO 17025:2017, On Job Training on testing of
Relevant Technical Training soil and building materials at KHRI, 2 days training on Uncertainty
Calculation
Landline No -
Mobile No 9497017459
Email lekshmi.subhash@gmail.com
Is this personnel proposed to report,review and authorization of
Yes
results(Signing of test reports) of CABS's
Specimen Signature Download
Employee Type Person Responsible for Technical Operations
Name Ms.-THULASI J
Designation Technical Manager FP
Qualification B.Tech
Specialization Civil engineering
Experience in Years Related to Present Work 3
Induction Training for Assistant Engineers Awareness Training
Relevant Technical Training programme on ISO 17025:2017, 2 days training on Measurement
uncertainty calculation
Landline No -
Mobile No 9061432858
Email thulasij100@gmail.com
Is this personnel proposed to report,review and authorization of
Yes
results(Signing of test reports) of CABS's
Specimen Signature Download
Employee Type Person responsible for management system
Name Mr.-Sreejith G H
Designation Deputy Lab Head FP
Qualification M. Tech
Specialization Civil Engineering
Experience in Years Related to Present Work 18
IRC certified Quality Management System Lead Auditor - ISO
Relevant Technical Training
9001:2008 certified by British standards Institute
Landline No -
Mobile No 8281774502
Email sreejithgh@yahoo.com
Is this personnel proposed to report,review and authorization of
Yes
results(Signing of test reports) of CABS's
Specimen Signature Download
Discipline: Mechanical
Group: Soil and Rock
Employee Type Person Responsible for Technical Operations
Name Ms.-Raseena A
Designation Technical Manager SMF
Qualification B.Tech
Specialization Civil engineering
Experience in Years Related to Present Work 5
Awareness Training on ISO 17025 : 2017Onjob Training on testing
Relevant Technical Training
of Soil -KHRI
Landline No -
Mobile No 9495992438
Email raseenaaneez@gmail.com
Is this personnel proposed to report,review and authorization of
Yes
results(Signing of test reports) of CABS's
Specimen Signature Download
Discipline: Mechanical,Non-destructive
Group:
Employee Type Others
Name Mrs.-Laji Gomez
Designation Asst. CSC
Qualification Diploma
Specialization Civil engineering
Experience in Years Related to Present Work 9
Relevant Technical Training Awareness training on IS/ISO/IEC 17025:2017
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible for receiving & reviewing Test Sample
Employee Type Others
Name Mrs.-ASWATHY K KAPPIL
Designation Technical Supervisor FP
Qualification Diploma
Specialization Civil engineering
Experience in Years Related to Present Work 5
Awareness Training programme on ISO 17025:2017, Onjob
Relevant Technical Training training on FP material testing, 2 days training on Measurement
uncertainty calculation
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Testing of aggregate and bitumin samples.
Employee Type Chief Executive of the Laboratory
Name Mr.-Thomas John
Qualification M.Tech
Specialization Civil
Experience in Years Related to Present Work 15
Awareness training on IS/ISO/IEC 17025:2017 On Job training on
Relevant Technical Training
mechanical testing of Building Material
Landline No -
Mobile No 7736005545
Email jointdirectorkhri@gmail.com
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Discipline: Mechanical,Non-destructive
Group: Buildings Materials
Employee Type Person Responsible for Technical Operations
Name Mr.-ABHIJITH RAVIKUMAR
Designation Technical Manager FP
Qualification M.Tech
Specialization Environmental engineering
Experience in Years Related to Present Work 4
Awareness Training programme on ISO 17025:2017 Training on
Relevant Technical Training mix design of flexible pavement, 2 days training on Measurement
uncertainty calculation
Landline No -
Mobile No 8281272461
Email ad1.fp.khri@gmail.com
Is this personnel proposed to report,review and authorization of
Yes
results(Signing of test reports) of CABS's
Specimen Signature Download
Discipline: Mechanical,Non-destructive
Group: Building Materials - Reinforced Concrete Structures,Buildings Materials
Employee Type Person responsible for management system
Name Mr.-RAKESH T MENON
Designation Deputy Lab Head CS
Qualification M.Tech
Specialization Structural Engineering
Experience in Years Related to Present Work 10
Awareness Training programme on ISO 17025:2017. 2 days
Relevant Technical Training
Training on Uncertainity Calculation
Landline No -
Mobile No 9895116918
Email rakeshtmenon@gmail.com
Is this personnel proposed to report,review and authorization of
Yes
results(Signing of test reports) of CABS's
Specimen Signature Download
Employee Type Person responsible for management system
Name Ms.-SREEPRIYA LAL
Designation Quality Manager
Qualification M.Tech
Specialization Traffic and Transportation Engineering
Experience in Years Related to Present Work 11
4 days Training on ISO 17025 : 2017 (IA training), 2 days training
on Measurement uncertainty calculation,Training on mix design of
Relevant Technical Training
high strength concrete –KHRITraining on testing of concrete in
structures
Landline No -
Mobile No 9497342824
Email dd.cs.khri@gmail.com
Is this personnel proposed to report,review and authorization of
Yes
results(Signing of test reports) of CABS's
Specimen Signature Download
Employee Type Person Responsible for Technical Operations
Name Mr.-SANKAR V
Designation Technical Manager CS
Qualification M.Tech
Specialization Applied Mechanics
Experience in Years Related to Present Work 5
Awareness Training on ISO 17025 : 2017, Training on mix design
of high strength concrete-KHRI Training on testing of concrete in
Relevant Technical Training
structures, on job training on NDT tests of Reinforcement Concrete
Structure, 2 days training on Measurement uncertainty calculation
Landline No -
Mobile No 9497264741
Email assistantdirectorkhri@gmail.com
Is this personnel proposed to report,review and authorization of
Yes
results(Signing of test reports) of CABS's
Specimen Signature Download
Discipline: Non-destructive
Group:
Employee Type Others
Name Ms.-Krishna Praseeda P
Designation Technical Supervisor NDT
Qualification M Tech
Specialization Hydraulics Engineering
Experience in Years Related to Present Work 3
On job training on NDT tests of Reinforcement Concrete Structure,
Relevant Technical Training
ISO/IEC 17025:2017 awareness training
Is this personnel proposed to report,review and authorization of
No
results(Signing of test reports) of CABS's
Remarks Responsible for NDT parameter Testing
Discipline: Non-destructive
Group: Building Materials - Reinforced Concrete Structures
Employee Type Person responsible for management system
Name Ms.-Sony JSD
Designation Deputy Lab Head
Qualification M Tech
Specialization Civil
Experience in Years Related to Present Work 10
Relevant Technical Training Awareness training programe on ISO 17025:2017
Landline No -
Mobile No 9567280376
Email sonyjsd@gmail.com
Is this personnel proposed to report,review and authorization of
Yes
results(Signing of test reports) of CABS's
Specimen Signature Download
Discipline: Mechanical,Non-destructive
Group: Buildings Materials,Soil and Rock
Employee Type Person Responsible for Technical Operations
Name Mr.-Sravan S
Designation CSE
Qualification B.Tech
Specialization Civil Engineering
Experience in Years Related to Present Work 3
4 days Training on ISO 17025:2017 , Training on building material,
Relevant Technical Training
soil& rock and RCS testing
Landline No -
Mobile No 8075120318
Email ss.saaga96@gmail.com
Is this personnel proposed to report,review and authorization of
Yes
results(Signing of test reports) of CABS's
Specimen Signature Download

Equipment Details
Details Data Feeded by Lab
Discipline: Mechanical
Group: Buildings Materials
Name of Equipment ELECTRONIC WEIGHING BALANCE- 1KG
UID KHRI/FP/B-001
Model ATTW
Serial No 1304926
Year Of Make 2015
Range 5g - 1000 g
Calibration Date 09-03-2022
Calibration Due on 09-03-2023
CalibratedBy External
External/ laboratory name Sophisticated Test and Instrumentation Center(STIC)
Name of Equipment ELECTRONIC WEIGHING BALANCE- 6KG
UID KHRI/FP/B-002
Model ATL
Serial No 1806082
Year Of Make 2018
Range 5g - 6Kg
Calibration Date 09-03-2022
Calibration Due on 09-03-2023
CalibratedBy External
External/ laboratory name Sophisticated Test and Instrumentation Center(STIC)
Name of Equipment ELECTRONIC WEIGHING BOUYANCY BALANCE- 15 KG
UID KHRI/FP/B-003
Model
Serial No 3300
Year Of Make 2015
Range 5g - 15Kg
Calibration Date 09-03-2022
Calibration Due on 09-03-2023
CalibratedBy External
External/ laboratory name Sophisticated Test and Instrumentation Center(STIC)
Name of Equipment ELECTRONIC WEIGHING BALANCE- 30KG
UID KHRI/FP/B-004
Model D 65
Serial No DS 6515489718
Year Of Make 2015
Range 20g - 30Kg
Calibration Date 19-03-2022
Calibration Due on 19-03-2023
CalibratedBy External
External/ laboratory name Sophisticated Test and Instrumentation Center(STIC)
Name of Equipment THICKNESS GAUGE
UID KHRI/FP/TG-001
Model
Serial No 200822 F
Year Of Make 2020
Range 12.5-10 to 63-50
Calibration Date
Calibration Due on
CalibratedBy Inhouse
In-house/traceability Internal Verification with Calibrated Digital Vernier
Name of Equipment LENGTH GAUGE
UID KHRI/FP/TLG-001
Model
Serial No 200817 L
Year Of Make 2020
Range 10-6.3 to 50-40
Calibration Date
Calibration Due on
CalibratedBy Inhouse
In-house/traceability Internal Verification with Calibrated Digital Vernier
Name of Equipment DOUBLE WALLED TYPE WATER BATH
UID KHRI/FP/WB-001
Model
Serial No 19C413
Year Of Make 2019
Range 0-100℃
Calibration Date 20-10-2021
Calibration Due on 20-10-2022
CalibratedBy External
External/ laboratory name Sophisticated Test and Instrumentation Center(STIC)
Name of Equipment SOFTENING APPARATUS
UID KHRI/FP/WB-002
Model
Serial No 181270
Year Of Make 2019
Range 0-100℃
Calibration Date 21-10-2021
Calibration Due on 21-10-2022
CalibratedBy External
External/ laboratory name Sophisticated Test and Instrumentation Center(STIC)
Name of Equipment VISCOSITY APPARUTUS- VISCOSITY BATH(135℃)
UID KHRI/FP/WB-003
Model 410
Serial No 180830
Year Of Make 2018
Range 0-150℃
Calibration Date 20-10-2021
Calibration Due on 20-10-2022
CalibratedBy External
External/ laboratory name Sophisticated Test and Instrumentation Center(STIC)
Name of Equipment VISCOSITY APPARUTUS- VISCOSITY BATH(60℃)
UID KHRI/FP/WB-004
Model 410
Serial No 180829
Year Of Make 2018
Range 0-150℃
Calibration Date 20-10-2021
Calibration Due on 20-10-2022
CalibratedBy External
External/ laboratory name Sophisticated Test and Instrumentation Center(STIC)
Name of Equipment ROLLING THIN FILM OVEN- TEMPERATURE
UID KHRI/FP/HAO-002
Model AIM-9840-S1
Serial No 18028
Year Of Make 2018
Range 80-163 ± 3℃
Calibration Date 20-10-2021
Calibration Due on 20-10-2022
CalibratedBy External
External/ laboratory name Sophisticated Test and Instrumentation Center(STIC)
Name of Equipment PENETROMETER
UID KHRI/FP/L-002
Model
Serial No 2011154
Year Of Make 2020
Range 0-400 mm
Calibration Date 13-12-2021
Calibration Due on 13-12-2022
CalibratedBy External
External/ laboratory name ALFATEK Services
Name of Equipment Digital CTM
UID KHRI/CS/DCTM/01
Model
Serial No 1804316
Year Of Make 2018
Range 0 - 3000kN
Calibration Date 07-09-2021
Calibration Due on 06-09-2022
CalibratedBy External
External/ laboratory name EIE Instruments PVT Ltd
Name of Equipment Hot Air Oven
UID KHRI/CS/HAO/02
Model
Serial No 131
Year Of Make 2020
Range 50ºC - 250ºC
Calibration Date 25-05-2022
Calibration Due on 25-05-2023
CalibratedBy External
External/ laboratory name Alfatek Services
Name of Equipment Electronic weighing balance - 30kg
UID KHRI/CS/EWB/01
Model CTG30
Serial No TT/0809/1447
Year Of Make
Range 10g – 30kg
Calibration Date 08-03-2022
Calibration Due on 08-03-2023
CalibratedBy External
External/ laboratory name STIC
Name of Equipment Electronic weighing balance - 10kg
UID KHRI/CS/EWB/03
Model ATL-TT
Serial No 1802258
Year Of Make
Range 20g – 10kg
Calibration Date 08-03-2022
Calibration Due on 08-03-2023
CalibratedBy External
External/ laboratory name STIC
Name of Equipment Electronic weighing balance-1 kg
UID KHRI/CS/EWB/04
Model ATLJW
Serial No 1304928
Year Of Make
Range 5g – 1kg
Calibration Date 08-03-2022
Calibration Due on 08-03-2023
CalibratedBy External
External/ laboratory name STIC
Name of Equipment Electronic weighing balance - 100g
UID KHRI/CS/EWB/05
Model MX7301A
Serial No 940088
Year Of Make
Range 0 – 100g
Calibration Date 08-03-2022
Calibration Due on 08-03-2023
CalibratedBy External
External/ laboratory name STIC
Name of Equipment Humidity chamber
UID KHRI/CS/HC/01
Model SRL/SC-10A
Serial No SR/195/19-20
Year Of Make 2020
Range Temp (10ºC to 40ºC) Humidity (45% to 95%)
Calibration Date 26-08-2021
Calibration Due on 26-08-2022
CalibratedBy External
External/ laboratory name Unique Calibration solutions
Name of Equipment Automatic mortar mixer
UID KHRI/CS/AMM/01
Model AIM- 412-4
Serial No 191082
Year Of Make 2019
Range 4.75L capacity
Calibration Date 10-12-2021
Calibration Due on 10-12-2022
CalibratedBy External
External/ laboratory name Unique Calibration solutions
Name of Equipment Vibrating machine
UID KHRI/CS/VIBM/01
Model AIM- 418-2
Serial No 133019
Year Of Make
Range
Calibration Date
Calibration Due on
CalibratedBy Inhouse
In-house/traceability Internal verification
Name of Equipment Vicat apparatus
UID KHRI/CS/VICA/01
Model AIM 394
Serial No 192898
Year Of Make
Range
Calibration Date
Calibration Due on
CalibratedBy Inhouse
In-house/traceability Internal verification
Name of Equipment Le-Chatelier mould
UID KHRI/CS/LM/01
Model AIM 400
Serial No
Year Of Make 2019
Range
Calibration Date
Calibration Due on
CalibratedBy Inhouse
In-house/traceability Internal verification
Name of Equipment Temperature and Humidity display unit
UID KHRI/CS/DTHM/01
Model 608-H1
Serial No 5606081
Year Of Make 2020
Temp 0 to 50ºC - Accuracy - 0.1ºCRH - 10 to 95% Accuracy
Range
- 0.1%
Calibration Date 02-12-2021
Calibration Due on 02-11-2022
CalibratedBy External
External/ laboratory name Unique calibration solutions
Name of Equipment 90 micron test seive
UID KHRI/CS/Sieve/02
Model AIM-05325
Serial No 191296
Year Of Make 2020
Range 90microns
Calibration Date 15-11-2021
Calibration Due on 15-11-2022
CalibratedBy External
External/ laboratory name Unique calibration solutions
Name of Equipment Stop Watch
UID KHRI/CS/SW/01
Model Racer/ 396
Serial No 396
Year Of Make
Range 0 to 30min(0.01s) 30minto 24hr(1s)
Calibration Date 02-12-2021
Calibration Due on 02-12-2022
CalibratedBy External
External/ laboratory name Unique calibration solutions
Name of Equipment BITUMEN EXTRACTOR
UID KHRI/FP/BE-001
Model
Serial No 93137
Year Of Make 2010
Range
Calibration Date
Calibration Due on
CalibratedBy Inhouse
In-house/traceability Internal verification
Name of Equipment Vicat apparatus
UID KHRI/CS/VICA/03
Model AIM 394
Serial No 203327
Year Of Make 2019
Range
Calibration Date
Calibration Due on
CalibratedBy Inhouse
In-house/traceability Internal Verification
Name of Equipment Steel scale
UID KHRI/CS/SC/01
Model
Serial No C&S/SC/1
Year Of Make
Range 0 – 1000mm
Calibration Date 03-11-2021
Calibration Due on 03-11-2022
CalibratedBy External
External/ laboratory name STIC
Name of Equipment Digital Vernier Caliper
UID KHRI/CS/DVC/01
Model
Serial No S.N.B19225338
Year Of Make
Range 0 - 150mm
Calibration Date 05-11-2021
Calibration Due on 05-11-2022
CalibratedBy External
External/ laboratory name Shreta Lab Tech
Name of Equipment Le-Chatelier flask
UID KHRI/CS/LF/03
Model AIM 401
Serial No C&S/LF/3
Year Of Make
Range 0 - 24ml
Calibration Date 24-11-2021
Calibration Due on 24-11-2022
CalibratedBy External
External/ laboratory name Unique Testing solutions
DUCTILITY TESTING MACHINE- DIGITAL
Name of Equipment
TEMPERATURE CONTROLLER
UID KHRI/FP/WB-005
Model KW/DH1
Serial No 1802410
Year Of Make
Range 0-100℃
Calibration Date 20-10-2021
Calibration Due on 21-10-2022
CalibratedBy External
External/ laboratory name STIC
Name of Equipment DUCTILITY TESTING MACHINE- STEEL SCALE
UID KHRI/FP/L-001
Model KW/DH1
Serial No 1802410
Year Of Make
Range 0-100 mm
Calibration Date 03-11-2021
Calibration Due on 03-11-2022
CalibratedBy External
External/ laboratory name STIC
Name of Equipment Electronic weighing balance
UID KHRI/CS/EWB/06
Model P1950
Serial No IND/0912004/396
Year Of Make
Range 10 – 100Kg
Calibration Date 25-11-2021
Calibration Due on 25-11-2022
CalibratedBy External
External/ laboratory name Unique Calibration
Name of Equipment Digital Temperature & Humidity Meter
UID KHRI/CS/DTHM/02
Model 971
Serial No 49530775
Year Of Make 2020
Range RH- 5 to 95%Temperature : -20 TO 45ºC
Calibration Date 27-10-2021
Calibration Due on 27-10-2022
CalibratedBy External
External/ laboratory name STIC
Name of Equipment Steel Scale
UID KHRI/CS/SS-01
Model
Serial No
Year Of Make 2020
Range 0-300mm
Calibration Date 03-11-2021
Calibration Due on 03-11-2022
CalibratedBy External
External/ laboratory name STIC
Name of Equipment Digital Vernier Caliper
UID KHRI/CS/DVC-02
Model
Serial No 142900E
Year Of Make
Range 0-300 mm
Calibration Date 01-10-2021
Calibration Due on 01-10-2022
CalibratedBy External
External/ laboratory name Unique Testing solutions
Name of Equipment Le-Chatelier Mould
UID KHRI/CS/LM/02 to 06
Model AIM 400
Serial No
Year Of Make 2019
Range
Calibration Date
Calibration Due on
CalibratedBy Inhouse
In-house/traceability Using Calibrated Vernier Caliper
Name of Equipment Digital CTM
UID KHRI/CS/DCTM/03
Model Controller -50-C10F02/M2000 kN Frame-CT 200
Serial No ControllerSr-No-22000089Frame 2000 kN Sr.No- 20220127
Year Of Make 2022
Range 0 - 2000kN
Calibration Date 05-04-2022
Calibration Due on 05-04-2023
CalibratedBy External
External/ laboratory name FORCE Measurement
Name of Equipment Digital CTM
UID KHRI/CS/DCTM/04
Model Controller -50-C10F02/M 500 kN Frame -C92Z40
Serial No ControllerSr-No-22000089Frame 500 kN Sr.No- 22000090
Year Of Make 2022
Range 0-500 kN
Calibration Date 05-04-2022
Calibration Due on 04-04-2023
CalibratedBy External
External/ laboratory name FORCE Measurement
Name of Equipment UTM
UID KHRI/CS/UTM/01
Model UTE-100
Serial No 5/2000-2651
Year Of Make 2000
Range 20 – 1000kN
Calibration Date 22-06-2022
Calibration Due on 22-06-2023
CalibratedBy External
External/ laboratory name Unique Testing solutions
Name of Equipment Electronic weighing balance - 50 kg
UID KHRI/CS/EWB/07
Model CWS50B
Serial No 20190318 210
Year Of Make 2019
Range 100 gm - 40 kg
Calibration Date 08-03-2022
Calibration Due on 08-03-2023
CalibratedBy External
External/ laboratory name STIC
Name of Equipment Electronic weighing balance - 220 gm
UID KHRI/CS/EWB/08
Model DXR-220
Serial No 215042004
Year Of Make 2021
Range 1 mg- 220 gm
Calibration Date 25-03-2022
Calibration Due on 25-03-2023
CalibratedBy External
External/ laboratory name STIC
Name of Equipment Electronic weighing balance - 20 kg
UID KHRI/CS/EWB/02
Model HV
Serial No 192115
Year Of Make
Range 20 gm - 20 kg
Calibration Date 08-03-2022
Calibration Due on 08-03-2023
CalibratedBy External
External/ laboratory name STIC
Name of Equipment Digital Vernier Caliper
UID KHRI/CS/DVC-03
Model TESA/IP67
Serial No 1G022471
Year Of Make
Range 0-300 mm
Calibration Date 02-12-2021
Calibration Due on 02-12-2022
CalibratedBy External
External/ laboratory name Unique Testing solutions
Name of Equipment Le-Chatelier flask
UID KHRI/CS/LF/04
Model
Serial No V211390
Year Of Make
Range 18 - 24ml
Calibration Date 10-12-2021
Calibration Due on 09-12-2022
CalibratedBy External
External/ laboratory name EIE Instruments Pvt.Ltd.
Name of Equipment Le-Chatelier flask
UID KHRI/CS/LF/05
Model
Serial No V211401
Year Of Make
Range 18 - 24ml
Calibration Date 24-12-2021
Calibration Due on 23-12-2022
CalibratedBy External
External/ laboratory name EIE Instruments Pvt.Ltd.
Name of Equipment 90 micron test sieve
UID KHRI/CS/Sieve/07
Model AIM-05325
Serial No 211431
Year Of Make
Range 90 microns
Calibration Date 25-11-2021
Calibration Due on 25-11-2022
CalibratedBy External
External/ laboratory name Unique calibration solutions
Name of Equipment Digital Water Bath for Soundness test
UID KHRI/CS/WB/03
Model PPI/ZENEX
Serial No 212223108
Year Of Make 2021
Range 20ºC – 100ºC
Calibration Date 05-12-2021
Calibration Due on 04-12-2022
CalibratedBy External
External/ laboratory name EIE Instruments Pvt.Ltd.
Name of Equipment Constant Temp. Water Bath.
UID KHRI/CS/WB/04
Model OMRON/E5CWL
Serial No 211206
Year Of Make 2021
Range 5ºC – 30ºC
Calibration Date 05-12-2021
Calibration Due on 04-12-2022
CalibratedBy External
External/ laboratory name EIE Instruments Pvt.Ltd.
Name of Equipment Water Bath
UID KHRI/CS/WB/02
Model Controller- Fourtech
Serial No
Year Of Make
Range 20ºC – 100ºC
Calibration Date 25-11-2021
Calibration Due on 25-11-2022
CalibratedBy External
External/ laboratory name Unique calibration solutions
Name of Equipment Curing Tank
UID KHRI/CS/CT/01
Model RTD-PT-100
Serial No 7884
Year Of Make
Range 20ºC – 50ºC
Calibration Date 25-11-2021
Calibration Due on 25-11-2022
CalibratedBy External
External/ laboratory name Unique calibration solutions
Name of Equipment HOT AIR OVEN
UID KHRI/FP/HAO-001
Model
Serial No 250915
Year Of Make 2015
Range 0-200℃
Calibration Date 13-12-2021
Calibration Due on 13-12-2022
CalibratedBy External
External/ laboratory name ALFATEK Services
Name of Equipment DIGITAL STOP WATCH
UID KHRI/FP/SW - 001
Model
Serial No DSW-01
Year Of Make
Range
Calibration Date 25-10-2021
Calibration Due on 25-10-2022
CalibratedBy External
External/ laboratory name STIC Cochin
Name of Equipment DIGITAL STOP WATCH
UID KHRI/FP/SW - 002
Model
Serial No DSW-02
Year Of Make
Range
Calibration Date 26-10-2021
Calibration Due on 26-10-2022
CalibratedBy External
External/ laboratory name STIC Cochin
Name of Equipment GLASS THERMOMETER
UID KHRI/FP/Tr -001
Model IP17C
Serial No P701874
Year Of Make
Range
Calibration Date 26-10-2021
Calibration Due on 26-10-2022
CalibratedBy External
External/ laboratory name STIC Cochin
Name of Equipment GLASS THERMOMETER
UID KHRI/FP/Tr - 002
Model
Serial No P501879
Year Of Make
Range
Calibration Date 26-10-2021
Calibration Due on 26-10-2022
CalibratedBy External
External/ laboratory name STIC Cochin
Name of Equipment DIGITAL THERMO HYGROMETER
UID KHRI/FP/HG-01
Model 608-H1
Serial No
Year Of Make
Range -20 to 50 degree
Calibration Date 02-12-2021
Calibration Due on 02-12-2022
CalibratedBy External
External/ laboratory name UNIQUE
Name of Equipment DIGITAL THERMO HYGROMETER
UID KHRI/FP/HG-02
Model 608-H1
Serial No
Year Of Make
Range -20 to 50 degree
Calibration Date 02-12-2021
Calibration Due on 02-12-2022
CalibratedBy External
External/ laboratory name UNIQUE
Name of Equipment BITUMEN EXTRACTOR
UID KHRI/FP/BE-002
Model
Serial No 2011281
Year Of Make 2020
Range 100 - 3600 rpm
Calibration Date 24-11-2021
Calibration Due on 24-11-2022
CalibratedBy External
External/ laboratory name Unique Calibration solutions
Discipline: Mechanical
Group: Soil and Rock
Name of Equipment Proving Ring 50kN
UID KHRI/SM&F/PR-06
Model
Serial No 638
Year Of Make
Range 0-50KN
Calibration Date 09-03-2022
Calibration Due on 08-05-2024
CalibratedBy External
External/ laboratory name DRS Engg&Calibration Services
Name of Equipment Compression Testing Machine for UCS
UID KHRI/SM&F/CTM-01
Model
Serial No 074-1-DG
Year Of Make
Range 0-2.5KN
Calibration Date 20-07-2022
Calibration Due on 20-07-2023
CalibratedBy External
External/ laboratory name Unique Testing solutions
Name of Equipment Displacement Sensor of UCS
UID KHRI/SM&F/DS-01
Model
Serial No
Year Of Make
Range 0-20mm
Calibration Date 20-07-2022
Calibration Due on 20-07-2023
CalibratedBy External
External/ laboratory name Unique Testing solutions
Name of Equipment Electronic Balance
UID KHRI/SM&F/BAL-01
Model
Serial No 8423
Year Of Make
Range 3200g
Calibration Date 10-03-2022
Calibration Due on 10-03-2023
CalibratedBy External
External/ laboratory name STIC Cochin
Name of Equipment Electronic Balance
UID KHRI/SM&F/BAL-02
Model
Serial No 1304927
Year Of Make
Range 5g-1000g
Calibration Date 09-03-2022
Calibration Due on 09-03-2023
CalibratedBy External
External/ laboratory name STIC Cochin
Name of Equipment Electronic Balance Casio
UID KHRI/SM&F/BAL-03
Model
Serial No 1908132
Year Of Make
Range 220g
Calibration Date 09-03-2022
Calibration Due on 09-03-2023
CalibratedBy External
External/ laboratory name STIC Cochin
Name of Equipment Electronic Balance
UID KHRI/SM&F/BAL-04
Model
Serial No 151008002
Year Of Make
Range 3200g
Calibration Date 10-03-2022
Calibration Due on 10-03-2023
CalibratedBy External
External/ laboratory name STIC Cochin
Name of Equipment Electronic Balance
UID KHRI/SM&F/BAL-05
Model
Serial No G8520451462
Year Of Make
Range 15Kg
Calibration Date 10-03-2022
Calibration Due on 10-03-2023
CalibratedBy External
External/ laboratory name STIC Cochin
Name of Equipment Hot Air Oven
UID KHRI/SM&F/HAV-01
Model TESTWEL Instrument
Serial No
Year Of Make
Range
Calibration Date 20-10-2021
Calibration Due on 20-10-2022
CalibratedBy External
External/ laboratory name STIC Cochin
Name of Equipment Proving Ring 25kN
UID KHRI/SM&F/PR-02
Model
Serial No 25kN.12816
Year Of Make
Range 0-25kN
Calibration Date 07-10-2021
Calibration Due on 07-12-2022
CalibratedBy External
External/ laboratory name DVG Laboratories
Name of Equipment Proving Ring 40kN
UID KHRI/SM&F/PR-03
Model Integral Proving Ring
Serial No 66001
Year Of Make
Range
Calibration Date 07-10-2021
Calibration Due on 07-12-2022
CalibratedBy External
External/ laboratory name DVG Laboratories
Name of Equipment Dial Gauge
UID KHRI/SM&F/DG-01
Model
Serial No 14474
Year Of Make
Range 0-25mm
Calibration Date 06-10-2021
Calibration Due on 06-10-2022
CalibratedBy External
External/ laboratory name STIC Cochin
Name of Equipment IS Sieve 20mm
UID KHRI/SM&F/S-01
Model GI Rigid frame perforated
Serial No
Year Of Make
Range 20mm
Calibration Date 24-09-2021
Calibration Due on 24-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment IS Sieve 4.75mm
UID KHRI/SM&F/S-02
Model
Serial No 48302
Year Of Make
Range 4.75mm
Calibration Date 24-09-2021
Calibration Due on 24-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment IS Sieve 2mm
UID KHRI/SM&F/S-03
Model
Serial No
Year Of Make
Range 2mm
Calibration Date 24-09-2021
Calibration Due on 24-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment IS Sieve 1mm
UID KHRI/SM&F/S-04
Model
Serial No
Year Of Make
Range 1mm
Calibration Date 24-09-2021
Calibration Due on 24-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment IS Sieve 600µ
UID KHRI/SM&F/S-05
Model
Serial No
Year Of Make
Range 600µ
Calibration Date 24-09-2021
Calibration Due on 24-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment IS Sieve 425µ
UID KHRI/SM&F/S-06
Model
Serial No
Year Of Make
Range 425µ
Calibration Date 24-09-2021
Calibration Due on 24-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment IS Sieve 212µ
UID KHRI/SM&F/S-07
Model
Serial No
Year Of Make
Range 212µ
Calibration Date 24-09-2021
Calibration Due on 24-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment IS Sieve 150µ
UID KHRI/SM&F/S-08
Model
Serial No
Year Of Make
Range 150µ
Calibration Date 24-09-2021
Calibration Due on 24-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment IS Sieve 75µ
UID KHRI/SM&F/S-09
Model
Serial No
Year Of Make
Range 75µ
Calibration Date 24-09-2021
Calibration Due on 24-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment Measuring Jar 100ml
UID KHRI/SM&F/MJ-01
Model
Serial No
Year Of Make
Range 10-100ml
Calibration Date 23-09-2021
Calibration Due on 23-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment Measuring Jar 100ml
UID KHRI/SM&F/MJ-02
Model
Serial No
Year Of Make
Range 10-100ml
Calibration Date 23-09-2021
Calibration Due on 23-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment Measuring Jar 250ml
UID KHRI/SM&F/MJ-03
Model
Serial No
Year Of Make
Range 10-250ml
Calibration Date 23-09-2021
Calibration Due on 23-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment Measuring Jar 1000ml
UID KHRI/SM&F/MJ-04
Model
Serial No
Year Of Make
Range 100-1000ml
Calibration Date 23-09-2021
Calibration Due on 23-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment Measuring Jar 1000ml
UID KHRI/SM&F/MJ-05
Model
Serial No
Year Of Make
Range 100-1000ml
Calibration Date 23-09-2021
Calibration Due on 23-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment Stop Watch
UID KHRI/SM&F/SW-02
Model
Serial No 12550
Year Of Make
Range 0-24 Hrs
Calibration Date 24-09-2021
Calibration Due on 24-09-2022
CalibratedBy External
External/ laboratory name Neno Technical Services
Name of Equipment Hydrometer
UID KHRI/SM&F/HM-01
Model
Serial No 143
Year Of Make
Range 0.995-1.030
Calibration Date 24-09-2021
Calibration Due on 24-09-2022
CalibratedBy External
External/ laboratory name Lab calibration
Name of Equipment Density Bottle 50ml
UID KHRI/SM&F/DB-01
Model
Serial No
Year Of Make
Range 50ml
Calibration Date 24-09-2021
Calibration Due on 24-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment Density Bottle 50ml
UID KHRI/SM&F/DB-02
Model
Serial No
Year Of Make
Range 50ml
Calibration Date 24-09-2021
Calibration Due on 24-11-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment Density Bottle 50ml
UID KHRI/SM&F/DB-03
Model
Serial No
Year Of Make
Range 50ml
Calibration Date 24-09-2021
Calibration Due on 24-09-2022
CalibratedBy External
External/ laboratory name Unique Testing Lab
Name of Equipment Digital Vernier
UID KHRI/SM&F/DV-01
Model
Serial No
Year Of Make
Range 0 to 300mm
Calibration Date 06-10-2021
Calibration Due on 06-10-2022
CalibratedBy External
External/ laboratory name STIC Cochin
Name of Equipment Hot Air Oven
UID KHRI/SM&F/HAV-02
Model Stericox/STXL0768
Serial No STRX20211109
Year Of Make
Range
Calibration Date 06-02-2021
Calibration Due on 04-02-2022
CalibratedBy External
External/ laboratory name STIC Cochin
Name of Equipment Thermometer (Digital)
UID KHRI/SM&F/TM-02
Model
Serial No DTM-902
Year Of Make
Range -40 to 250 degC
Calibration Date 22-10-2021
Calibration Due on 14-10-2022
CalibratedBy External
External/ laboratory name Unique
Discipline: Non-destructive
Group: Building Materials - Reinforced Concrete Structures
Name of Equipment Ultrasonic Pulse Velocity
UID KHRI/CS/NDT/01
Model Pundit PL200
Serial No UP01-004-0180
Year Of Make 2020
Range 1 to 7930 Microsecond
Calibration Date
Calibration Due on
CalibratedBy Inhouse
In-house/traceability Calibrated before every use, using standard calibration rods
Name of Equipment Half Cell Potential
UID KHRI/CS/NDT/02
Model Profometer Corrosion
Serial No PM10-003-0220
Year Of Make 2020
Range -1000 to + 1000 mV
Calibration Date 22-08-2021
Calibration Due on 22-08-2022
CalibratedBy External
External/ laboratory name Samhita Innovations
Name of Equipment Rebar Locator
UID KHRI/CS/NDT/03
Model Profometer PM650AI
Serial No UP01-008-0442
Year Of Make 2020
Range Upto 185 mm
Calibration Date
Calibration Due on
CalibratedBy Inhouse
In-house/traceability Calibrated before every use using Standard Test Block
Name of Equipment Rebound Hammer
UID KHRI/CS/NDT/04
Model Silver Schmidt PCN
Serial No SH01-011-0218
Year Of Make 2020
Range 10 - 100 MPa
Calibration Date 30-08-2021
Calibration Due on 22-08-2022
CalibratedBy Inhouse
In-house/traceability Calibration before every use using Standard Anvil

Reference Material Details


Details Data Feeded by Lab
Discipline: Mechanical
Group: Buildings Materials
Name of Reference Material/Strain/Culture Viscosity Standard: N 2700000
Source CANNON
Date of Expiry 31/03/2023
Traceability NIST
Name of Reference Material/Strain/Culture Viscosity Standard: J98650
Source CANNON
Date of Expiry 31/10/2022
Traceability NIST
Standard calibration weight set – (Milligram weights and Gram
Name of Reference Material/Strain/Culture weights) F2 class- 1 kg, 2kg, 5 kg, 10kg, 20 kg, F1 class - 1 mg to
500 gm (24 pieces)
Source Aczet, Shiam
Date of Expiry
Traceability NABL
Discipline: Non-destructive
Group: Building Materials - Reinforced Concrete Structures
Name of Reference Material/Strain/Culture Test Block for Cover Meter Test
Source Proceq
Date of Expiry
Traceability Proceq
Name of Reference Material/Strain/Culture Test Anvil of 91+/-2 Q
Source Proceq
Date of Expiry
Traceability Proceq
Name of Reference Material/Strain/Culture UPV calibration block of 100.4 Micro Sec & 25.4 micro sec
Source Proceq
Date of Expiry
Traceability Proceq

Proficiency Testing
Details Data Feeded by Lab
Discipline: Mechanical
Group: Buildings Materials
Type of Participation PT
Product/Material Paver Blocks
Details of Test(s) Water Absorption
Date of Testing 30-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 0.43
Corrective Action Taken NA
Type of Participation PT
Product/Material Paver Blocks
Details of Test(s) Compressive Strength
Date of Testing 30-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 1.09
Corrective Action Taken NA
Type of Participation PT
Product/Material Cement
Details of Test(s) Density
Date of Testing 07-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 0.24
Corrective Action Taken NA
Type of Participation PT
Product/Material Cement
Details of Test(s) Compressive Strength
Date of Testing 07-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 1.26
Corrective Action Taken NA
Type of Participation PT
Product/Material Cement
Details of Test(s) Final Setting Time
Date of Testing 07-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 0.43
Corrective Action Taken NA
Type of Participation PT
Product/Material Cement
Details of Test(s) Initial Setting Time
Date of Testing 07-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 0.00
Corrective Action Taken NA
Type of Participation PT
Product/Material Cement
Details of Test(s) Standard Consistency
Date of Testing 07-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 0.1
Corrective Action Taken
Type of Participation PT
Product/Material
Details of Test(s) Bulk Density
Date of Testing 09-12-2021
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd.
Performance in Terms of Z Score / Any Other Criteria -0.08
Corrective Action Taken NA
Type of Participation PT
Product/Material
Details of Test(s) Sieve Analysis
Date of Testing 26-12-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testing and Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria 0.55
Corrective Action Taken NA
Type of Participation PT
Product/Material Fine Aggregate
Details of Test(s) Sieve Analysis
Date of Testing 26-12-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testing and Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria -0.01
Corrective Action Taken NA
Type of Participation PT
Product/Material Fine Aggregate
Details of Test(s) Sieve Analysis
Date of Testing 08-12-2021
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd.
Performance in Terms of Z Score / Any Other Criteria 0.18
Corrective Action Taken NA
Type of Participation PT
Product/Material Fine Aggregate
Details of Test(s) Water Absorption
Date of Testing 08-12-2021
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd
Performance in Terms of Z Score / Any Other Criteria 0.07
Corrective Action Taken NA
Type of Participation PT
Product/Material Coarse Aggregate
Details of Test(s) Aggregate Impact Value
Date of Testing 03-01-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd
Performance in Terms of Z Score / Any Other Criteria 2.23
Corrective Action Taken NA
Type of Participation PT
Product/Material Coarse Aggregate
Details of Test(s) Los Angeles Abrasion Test
Date of Testing 04-01-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd
Performance in Terms of Z Score / Any Other Criteria 0.70
Corrective Action Taken NA
Type of Participation PT
Product/Material Bitumen
Details of Test(s) Softening Point
Date of Testing 17-05-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd
Performance in Terms of Z Score / Any Other Criteria 0.00
Corrective Action Taken NA
Type of Participation PT
Product/Material Bitumen
Details of Test(s) Penetration
Date of Testing 17-05-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd
Performance in Terms of Z Score / Any Other Criteria -2.46
Corrective Action Taken NA
Type of Participation PT
Product/Material Bitumen
Details of Test(s) Ductility
Date of Testing 17-05-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd
Performance in Terms of Z Score / Any Other Criteria Results awaiting
Corrective Action Taken
Type of Participation PT
Product/Material Bitumen
Details of Test(s) Viscosity – Kinematic
Date of Testing 17-05-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd
Performance in Terms of Z Score / Any Other Criteria -0.83
Corrective Action Taken NA
Type of Participation PT
Product/Material Solid Blocks
Details of Test(s) Compressive Strength
Date of Testing 02-03-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testing and Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria 0.06
Corrective Action Taken NA
Type of Participation PT
Product/Material Solid Blocks
Details of Test(s) Water Absorption
Date of Testing 03-03-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testing and Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria 0.37
Corrective Action Taken NA
Type of Participation PT
Product/Material Concrete Cores
Details of Test(s) Compressive Strength
Date of Testing 25-06-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testing and Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria Result Awaiting
Corrective Action Taken
Type of Participation PT
Product/Material Paver Block
Details of Test(s) Compressive Strength
Date of Testing 27-05-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Bureau Veritas (India )Pvt.Ltd
Performance in Terms of Z Score / Any Other Criteria 0.01
Corrective Action Taken NA
Type of Participation PT
Product/Material Paver Block
Details of Test(s) Water Absorption
Date of Testing 28-05-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Bureau Veritas (India )Pvt.Ltd
Performance in Terms of Z Score / Any Other Criteria 1.06
Corrective Action Taken NA
Type of Participation PT
Product/Material Coarse Aggregate
Details of Test(s) Flakiness Index
Date of Testing 26-12-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testingand Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria 0.65
Corrective Action Taken NA
Type of Participation PT
Product/Material Coarse Aggregate
Details of Test(s) Elongation Index
Date of Testing 26-12-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testingand Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria 0.3
Corrective Action Taken NA
Type of Participation PT
Product/Material Coarse Aggregate
Details of Test(s) Specific Gravity
Date of Testing 26-12-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testingand Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria 0.00
Corrective Action Taken NA
Type of Participation PT
Product/Material Coarse Aggregate
Details of Test(s) Water Absorption
Date of Testing 26-12-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testingand Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria 0.7
Corrective Action Taken NA
Type of Participation PT
Product/Material Coarse Aggregate
Details of Test(s) Sieve Analysis
Date of Testing 26-12-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testingand Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria 0.29
Corrective Action Taken NA
Type of Participation PT
Product/Material Concrete Cubes
Details of Test(s) Compressive Strength
Date of Testing 28-10-2021
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt. Ltd
Performance in Terms of Z Score / Any Other Criteria Results Awaiting
Corrective Action Taken NA
Type of Participation PT
Product/Material Fine Aggregate
Details of Test(s) Sieve Analysis
Date of Testing 08-12-2021
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd.
Performance in Terms of Z Score / Any Other Criteria -1.12
Corrective Action Taken NA
Type of Participation PT
Product/Material Fine Aggregate
Details of Test(s) Sieve Analysis
Date of Testing 08-12-2021
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd.
Performance in Terms of Z Score / Any Other Criteria -0.15
Corrective Action Taken NA
Type of Participation PT
Product/Material Fine Aggregate
Details of Test(s) Specific Gravity
Date of Testing 08-12-2021
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd.
Performance in Terms of Z Score / Any Other Criteria 0.02
Corrective Action Taken
Type of Participation PT
Product/Material Bitumen
Details of Test(s) Specific Gravity
Date of Testing 10-08-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testing and Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria Result awaiting
Corrective Action Taken
Type of Participation PT
Product/Material Bitumen
Details of Test(s) Softening Point
Date of Testing 10-08-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testing and Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria Result awaiting
Corrective Action Taken
Type of Participation PT
Product/Material Bitumen
Details of Test(s) Penetration
Date of Testing 10-08-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testing and Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria Result awaiting
Corrective Action Taken
Type of Participation PT
Product/Material Bitumen
Details of Test(s) Ductility
Date of Testing 10-08-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testing and Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria Result awaiting
Corrective Action Taken
Type of Participation PT
Product/Material Bitumen
Details of Test(s) Absolute Viscosity
Date of Testing 10-08-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testing and Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria Result awaiting
Corrective Action Taken
Type of Participation PT
Product/Material Bitumen
Details of Test(s) Softening Point
Date of Testing 10-08-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testing and Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria Result awaiting
Corrective Action Taken
Discipline: Mechanical
Group: Soil and Rock
Type of Participation PT
Product/Material Soil
Details of Test(s) Shrinkage Limit
Date of Testing 20-12-2021
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd
Performance in Terms of Z Score / Any Other Criteria 1.03
Corrective Action Taken NA
Type of Participation PT
Product/Material Soil
Details of Test(s) Shrinkage Limit
Date of Testing 20-12-2021
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd
Performance in Terms of Z Score / Any Other Criteria 1.03
Corrective Action Taken NA
Type of Participation PT
Product/Material Soil
Details of Test(s) Specific Gravity
Date of Testing 17-12-2021
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd
Performance in Terms of Z Score / Any Other Criteria -1.26
Corrective Action Taken NA
Type of Participation PT
Product/Material Soil
Details of Test(s) Liquid Limit
Date of Testing 17-12-2021
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd
Performance in Terms of Z Score / Any Other Criteria -0.34
Corrective Action Taken NA
Type of Participation PT
Product/Material Soil
Details of Test(s) Plastic Limit
Date of Testing 17-12-2021
Nodal Laboratory/PT Provider (Accreditation Body/Country) Green Economy Initiatives Pvt.Ltd
Performance in Terms of Z Score / Any Other Criteria 0.07
Corrective Action Taken NA
Type of Participation PT
Product/Material
Details of Test(s) Unconfined Compressive Strength
Date of Testing 08-08-2022
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark Material Testing and Research Laboratory Pvt. Ltd.
Performance in Terms of Z Score / Any Other Criteria Result Awaiting
Corrective Action Taken
Type of Participation PT
Product/Material Soil
Details of Test(s) Free Swell Index
Date of Testing 07-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 1.24
Corrective Action Taken NA
Type of Participation PT
Product/Material Soil
Details of Test(s) CBR
Date of Testing 07-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 0
Corrective Action Taken NA
Type of Participation PT
Product/Material Soil
Details of Test(s) Heavy Compaction
Date of Testing 07-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 1.25
Corrective Action Taken NA
Type of Participation PT
Product/Material Soil
Details of Test(s) Heavy Compaction
Date of Testing 07-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 1.53
Corrective Action Taken NA
Type of Participation PT
Product/Material Soil
Details of Test(s) Light Compaction
Date of Testing 07-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 0.33
Corrective Action Taken NA
Type of Participation PT
Product/Material Soil
Details of Test(s) Light Compaction
Date of Testing 07-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 0.32
Corrective Action Taken NA
Type of Participation PT
Product/Material Soil
Details of Test(s) Grain Size Analysis- by Hydrometer Analysis
Date of Testing 07-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 0.03
Corrective Action Taken NA
Type of Participation PT
Product/Material Soil
Details of Test(s) Grain Size Analysis- by Wet Sieving
Date of Testing 07-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 0.47
Corrective Action Taken NA
Type of Participation PT
Product/Material Soil
Details of Test(s) Grain Size Analysis- by Dry Sieving
Date of Testing 07-10-2020
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 0.82
Corrective Action Taken
Discipline: Non-destructive
Group: Building Materials - Reinforced Concrete Structures
Type of Participation PT
Product/Material Concrete Structure
Details of Test(s) Half Cell Potential difference test
Date of Testing 11-01-2021
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 0.91
Corrective Action Taken NA
Type of Participation PT
Product/Material Concrete Structure
Details of Test(s) Ultrasonic Pulse Velocity Tests
Date of Testing 11-01-2021
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 1.00
Corrective Action Taken NA
Type of Participation PT
Product/Material Concrete Structure
Details of Test(s) Rebound Hammer Test
Date of Testing 11-01-2021
Nodal Laboratory/PT Provider (Accreditation Body/Country) Landmark material Testing and Research Laboratory Pvt Ltd
Performance in Terms of Z Score / Any Other Criteria 00
Corrective Action Taken NA
Payment Information
No Data Available

Declaration Report
Terms & Conditions for Obtaining and Maintaining NABL Accreditation

The terms and conditions mentioned in this document is considered as accreditationagreement between NABL and Conformity Assessment Body (CAB).
By accepting theseterms and conditions, it is implied that a CAB as an applicant and after obtainingaccreditation agrees to comply at all times with all
Terms and Conditions for NABLAccreditation. Any violation of this terms and conditions (Accreditation agreement) shallresult in adverse decision as per
NABL 216 ‘Procedures for Dealing with Adverse Decisions’including legal action.
The Conformity Assessment Body {Testing Laboratory/ Calibration Laboratory/ MedicalTesting Laboratory/ Proficiency Testing Provider (PTP)/
Reference Material Producer(RMP)} that are applicant or accredited by NABL shall be required to fulfill the following termsand conditions:

1. The Conformity Assessment Body (CAB) shall carry out its Testing / Calibration / Medical/PTP / RMP activities in such a way as to meet the
requirements of ISO/IEC 17025/ ISO15189/ ISO/IEC 17043/ ISO 17034 whichever is applicable, relevant NABL specific criteria(wherever
applicable) and other policies of NABL
2. CAB shall ensure that the latest versions of NABL documents are available with them andare effectively implemented.
3. CAB shall familiarize themselves with all relevant standards, NABL documents etc.applicable for particular accreditation scheme.
4. The CAB shall have a valid legal identity as given below.
a. Proprietorship(Bank passbook/ Account statement and PAN of the CAB)
b. Limited LiabilityPartnership(Registration certificate under The Limited Liability Partnership Act,2008)
c. Company (Registration certificate under The Companies Act, 1956 or 2013)
d. Societies/ Trust(Registration certificate under Societies Registration Act, 1860/Registration under The Indian Trusts Act,
1882)
e. Government(Gazette or Government Notification or self-Declaration on Letterhead by Head of the organization)
5. It is the responsibility of CAB to abide by the National/ Regional/ State/ Local regulatoryrequirement/ Acts/ Rules/ Legal orders/ Court
Decisions/ Orders issued by Government/Statutory Bodies as applicable and effective from time to time.
6. The CAB shall identify and define various activities which they are involved in, and ensurethat it does not lead to any potential conflict of
interest.
7. The CAB shall have qualified and trained personnel for applied/ accredited scope includingsampling (wherever applicable), person declared by
CAB to NABL who is responsible toreport, review and authorize the results who meet the requirements of relevant NABL specificcriteria
(wherever applicable) for each field / discipline of accreditation.
8. The CAB shall have qualified and trained personnel who is responsible for formulatingopinion and interpretation in the report/ certificate
(wherever applicable).
9. Wherever applicable, the CAB shall follow the test methods as mentioned in the currentNational or International standards and as stipulated by
regulatory bodies. Where suchmethods do not exist, other validated methods are acceptable. In case CAB uses in-housevalidated methods,
the validation data should be submitted along with the application.
10. Applicant CAB shall successfully participate in at least one PT program prior to gainingaccreditation in each discipline applied. Requirements
specified in NABL 163 shall befollowed for PT participation.
11. CAB shall submit the completed application for renewal of accreditation six months prior tothe expiry of accreditation and also agree to
undergo assessment as per the scheduleproposed by NABL to maintain continuity in accreditation cycle. Application submitted afterexpiry of
accreditation will be considered as fresh application.
12. The CAB shall offer cooperation to NABL or its representative in:
a. Undergoing assessments in stipulated time intervals / whenever NABL considered it asrequired.
b. Access to all CAB areas of operations including Mobile/ temporary, site facility,subcontractor premises, wherever relevant and
applicable.
c. Undertaking any check / inspection to verify the capability of the CAB for the applied /accredited scope.
d. Witnessing the activities being performed relevant to accreditation.
e. Assessing the competence of the staff (including staff working in shift operations / at site)during assessment.
f. Access to all relevant information and documentation
g. Access to those documents that provide insight into the level of independence andimpartiality to the CAB from its related bodies, if
applicable.
h. Access to all records pertaining to relevant personnel.
i. Assessing the competence of the persons who are responsible to report, review andauthorize the results,
j. Assessing the competence of the persons who are responsible for opinion andinterpretation,
k. Unannounced visit,
l. Investigating any complaints related to NABL accreditation, against the CAB.
13. During the accreditation period, the CAB shall claim accreditation in only those premises,and scope for which it has been accredited (as stated
in Accreditation Certificate and scopeof Accreditation).
14. Accredited CAB shall adhere to ‘NABL 133’ for the use of NABL symbol, use of NABLAccredited CAB Combined ILAC MRA
Mark as well as any claim of accreditation of the CAB.CAB shall ensure that it fully conforms to the requirements of NABL and ISO/IEC
17025 /ISO 15189 / ISO/IEC 17043 / ISO 17034 for claiming accreditation status while makingreference of its NABL accreditation in
communication media. Actions like suspension, debar,legal action etc. may be taken in case of violation of NABL 133.
15. CAB shall use NABL accredited CAB Combined ILAC MRA Mark only after obtaining writtenpermission from NABL.
16. Accredited CAB shall make it clear in all its contracts with customers that its activities fallingunder accredited scope in no way imply that the
product so tested or equipment calibratedis approved by NABL.
17. The accredited CAB is neither allowed to make misleading / unauthorized statementregarding its accreditation nor refer to accreditation in such
a way so to imply that a product,process, service, management system or person is approved by NABL.
18. The CAB shall pay application fees for accreditation, re-accreditation; expenses towardstravel, boarding & lodging for any kind of assessment
including supplementary visit, on-sitesurveillance, desktop surveillance, re-assessment and annual accreditation fees as shall bedetermined from
time to time, by NABL.
19. The CAB shall inform NABL without delay of significant changes affecting the CAB’sactivities and operations relevant to accreditation,
such as:
a. its legal, commercial, ownership or organizational status,
b. resources and premises,
c. scope of accreditation,
d. sub-contractor addition (RMP), and
e. other such matter that may affect the ability of the CAB to fulfill the requirements of NABLaccreditation including policies, ISO/ IEC
17025 or ISO 15189 or ISO/IEC 17043 or ISO17034 whichever is applicable.
20. The CAB shall inform NABL within 15 days of changes, such as:
a. the organization top management, key personnel including sampler (where applicable),person responsible for report, review and
authorizing the results,
b. main policies, and
c. any change in the Sample Collection Centre/ Facility (ies) to NABL.
21. The CAB shall regularly visit NABL website to keep itself updated with the latest versions ofNABL documents.
22. CAB shall always have a dedicated person responsible for implementation of ManagementSystem.
23. The CAB shall unambiguously declare the name of any individual and organization that hasprovided consultancy for preparing towards NABL
accreditation.
24. Where a CAB subcontracts a substantial or critical part of the accredited activities that workshall be placed with another accredited CAB
only.
25. The accredited CAB shall commit to comply with the changes initiated by NABL in itsaccreditation criteria, policies and procedures. The CAB
shall inform NABL when suchalterations under the agreed time frame have been completed.
26. The CAB shall take all necessary actions and discharge all non- conformities raised duringthe assessment within the stipulated time to avoid any
adverse decisions against it asdetailed in ‘NABL 216’. The same shall be verified to the satisfaction of NABL. The finaldecision on
accreditation shall rest with NABL.
27. CAB shall not use its NABL accreditation in such a manner as to bring NABL into disrepute.
28. CAB shall not claim NABL accreditation after shifting premises, till communication on grantat new premises is done by NABL
29. At any point in the application or initial process, if there is an evidence of fraudulent behaviourand/ or if the CAB has intentionally provided
false information or conceals information, NABLshall reject the application or terminate the assessment process.
30. If an evidence is found of fraudulent behaviour or the CAB intentionally provides falseinformation or conceals information, NABL shall initiate
adverse action as per NABL 216.
31. The accredited CAB upon suspension, withdrawal of accreditation or debar from reapplying(however determined) shall forthwith discontinue
claim of accreditation in any form in alladvertising material and return the accreditation certificates to NABL.
32. CAB shall inform its affected clients of the suspension, scope reduction, withdrawal ofaccreditation or debar from reapplying and the
associated consequences without unduedelay.
33. The accredited CAB can relinquish accreditation by giving notice in writing to NABL bysurrendering the accreditation certificates after clearing
the outstanding amount, if any.
34. The CAB shall inform NABL, if any of the proposed assessor(s) happens to be theirConsultant or associated with the CAB in any other
capacity (personal or professional).
35. NABL absolves itself of any legal or financial liability arising out of activities of any of itsaccredited CAB involving any accidental or
consequential damages to personnel /equipment / products at any time.
36. CAB shall not offer any gifts or any kind of payments in cash or any undue favour to theassessment team members. In case of any violation,
NABL shall suspend the accreditationof the CAB as per NABL 216.
37. The application shall be kept confidential (unless required by law) by NABL and informationobtained during the processing of application,
assessment visit and grant of accreditationshall be safeguarded and dealt with impartiality.
38. CAB shall offer co-operation to NABL assessment team in carrying out unannouncedassessment as a part of continuous monitoring activity by
NABL for its accredited CABs.
39. CAB shall ensure the capability w.r.t. applied scope for accreditation (availability ofresources such as personnel, equipment, CRM, method
validation etc.) before applying toNABL.

By accepting these terms and conditions, it is implied that a CAB as an applicant and afterobtaining accreditation agrees to comply at all times with all
Terms and Conditions forObtaining and Maintaining NABL Accreditation. Any violation of this terms and conditions(arrangement) shall result in adverse
decision as per NABL 216 ‘Procedures for Dealing withAdverse Decisions’ including legal action.

Dispute, if any, arising out of NABL decisions that remain unresolved through mechanismprovided by NABL are subject to the exclusive jurisdiction of
the Courts at New Delhi andnone other.
We declare that
1. We shall comply with the terms and conditions of maintaining accreditation (NABL 131) and will abide by them.
2. We shall fully comply with ISO/IEC 17025:2017 or ISO 15189:2012 or ISO/IEC 17043:2010 or ISO 17034:2016, whichever is relevant for the
accreditation of Conformity Assessment Body.
3. We shall comply with all national, regional and local regulatory requirements for operating a laboratory.
4. We agree to comply with accreditation procedures and pay all costs for pre-assessment, assessment, verification visit (if any), surveillance and
reassessment irrespective of the result.
5. We agree to co-operate with the assessment team appointed by NABL for examination of all relevant documents by them and their visits to those
parts of the laboratory that are part of the scope of accreditation.
6. The information provided herein with reference to the consultancy provided to us and also in respect of any adverse decision, taken by NABL or
by any other Accreditation Body is true to the best of our knowledge and believe and nothing has been concealed.
7. All other information provided in this application is true and nothing has been concealed.
8. For any payment which has not been made in response to the bills raised by NABL, we are liable for adverse action which may be initiated by
NABL as specified in NABL 216.
9. If any information is found to be false or has been concealed wilfully, we are liable for any lawful action which may be initiated by NABL as
deemed fit.
10. For any payment which has not been made in response to the bills raised by NABL, we are liable for adverse action as specified inNABL 216
11. If any information is found to be false or has been concealed wilfully, we are liable for any lawful action as deemed fit.
--------------End Of Report--------------