5000 - 2021 - 1 - 02 07 202114 57 31 - OPC 25W7Days

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

JK LAKSHMI CEMENT LTD-DURG

MALPURIKHURD - PO: AHIWARA-490036 Dist-DURG


TEST REPORT FOR JK LAKSHMI OPC 43 GRADE

ULR NO.JKLC/DU/QC/OPC/W-25 LICENSE NO-CM/L 5900002305 TC-


PARTY NAME/ADDRESS:
WEEK NO.25 ( 18.06.2021 to 24.06.2021 ) DATE OF ISSUE-02.07.2021
CHEMICAL/PHYSICAL TEST METHOD REQUIRMENT ASPER RESULTS
REQUIRMENTS IS 269:2015 OBTAINED
(Sixth Revision)
CHEMICAL REQUIREMENTS:- 6
(i) Ratio of Percentage of Lime to percentage of Not Greater than 1.02 And 0.83
silica, alumina and iron oxide not less than 0.66

CaO-0.7S03
----------------------------
2.8 Si02 + 1.2 Al2O3 + 0.65 Fe2o3

(ii) Ratio of percentage of alumina to that of Not less than 0.66 1.46
iron oxide Al2O3/Fe2O3
(iii) Insoluble residue, percent by mass IS-4032-4.1 Not more than 5.0 2.16
(iv) Magnesia, percent by mass IS-4032-4.8 Not more than 6.0 4.84
(v) Total sulphur calculated as Sulphuric IS-4032-4.9 Not more than 3.5 2.22
Anhydride (SO3), Percent by mass
(vi) Total loss on ignition IS-4032-4.2 Not more than 5% 2.68
(vii) Chloride, percent by mass IS-4032-4.13 AND - Not more than 0.1 0.010
02/2020
PHYSICAL REQUIREMENTS : 7
(I) FINENESS :
SP:SURFACE IS-4031-PART-II 2018 Not less than 225 M2/Kg 335
(II) SOUNDNESS :
a) Le-chatelier method Expansion (IS 4031)(PART-III) Not more than 10 mm 1.0
2019
b) Auto clave test expansion (IS 4031)(PART-III) Not more than 0.8% 0.21
2019
(III) SETTING TIME
a) Initial Setting time in Minutes (IS-4031)(PART-V) 2019 Not less than 30 166
b) Final Setting time in Minutes (IS-4031)(PART-V) 2019 Not more than 600 225
(IV) COMPRESIVE STRENGTH: (IS-4031)(PART-VI)
2019
72 ± 1 Hours (3 DAYS) Not Less than 23 MPA 31.0
168 ± 2 Hours (7 DAYS) Not lesss than 33 MPA 41.8
672 ± 4 Hours (28 DAYS) Not less than 43 MPa * Not UNDER TESTING
more than 58 MPA
NC % 28.75
REMARKS: The Test results complies with the requirements of IS 269:2015 for OPC 43 GRADE all Chemical and
Physical Requirements. All the test carried out at 27±2°C temp. & humidity min. 65%.
Protocol:IS:4032 and IS:4031.

Note:Results reported above are the average test results of all samples testing during relevent week.

CERTIFIED Reviewed by Authorised Signatory


9001:2015 Emp Name - Saurabh Sharma Emp Name - SUMIT GANGULY
14001:2015 Emp code - 00150105 Emp code - 00150283
45001:2018
50001:2018
JKLC/QC/FIN/03