FIRE PREVENTION DEPARTMENT

GENERAL DIRECTORATE OF CIVIL DEFENCE


MINISTRY OF INTERIOR, STATE OF QATAR

PROJECT DESCRIPTION FIRE AND LIFE SAFETY PROVISIONS OCCUPANT LOAD CALCULATION
(SPECIFY EACH PROVISION FOR EVERY BUILDING)

GENERAL DESCRIPTIONS: THIS SUBMISSION IS RELATED TO THE REVISION OF QCDD APPROVED LIFE SAFETY PLANS OCCUPANT LOAD
FOR THE PROPOSED CENTRAL MARKET (G+M), LABOR ACCOMMODATION (G+1), & SUBSTATION (G) WITH A TOTAL PLOT FIRE FIGHTING SYSTEM FLOOR LEVEL/ SPACE USE
OCCUPANCY/ FLOOR AREA
FACTOR
OCCUPANT LOAD NUMBER OF MEANS OF
AREA OF 57,934.31 SQUARE METERS. USE (SQ. M) (PERSONS) EXITS EGRESS
(SQ. M/PERSON)
AUTOMATIC SPRINKLER SYSTEM COMPONENT/S
NUMBER OF STOREYS: CENTRAL MARKET (G+M), ACCOMMODATION (G+1), SUBSTATION (G) COVERAGE: THROUGHOUT (CENTRAL MARKET) CENTRAL MARKET
PARTIAL PROTECTION; SPECIFY AREAS PROTECTED: ______________________ GROUND FLOOR LEVEL - IDF, MDF, ELECTRICAL ROOMS & PRE-ACTION RM.
INDUSTRIAL
191.00
MAXIMUM
21 17 DOORS
DESCRIPTION OF MODIFICATIONS: N/A (Esp. purpose) PROBABLE
1. SITE DEVELOPMENT PLAN:
A. ADDED NEW SERVICE ENTRANCE/EXIT GATE AT NORTHWEST SIDE.
B. DRIVEWAY WAS CUT AND SERVICE ENTRANCE/EXIT GATE WAS OMITTED. MANUAL FIRE FIGHTING SYSTEM LABOR ACCOMMODATION
APPROVING AUTHORITY
INDUSTRIAL
C. ADDED NEW SERVICE ENTRANCE/EXIT GATE AT SOUTHEAST SIDE. FIRE HOSE REELS GROUND FLOOR LEVEL - NEW FM 200 CABINET
(Esp. purpose)
NA NA NA 2 DOORS
2. CENTRAL MARKET: PORTABLE FIRE EXTINGUISHERS FIRST FLOOR LEVEL - NEW FM 200 CABINET
INDUSTRIAL
NA NA NA 2 STAIRS PS NUMBER : N/2017/0005893
D. ADDED NEW IDF ROOM PROTECTED WITH FM 200 SYSTEM AND 1.0 HOUR FIRE RATED WALLS WITH 45 (Esp. purpose)
N/A
MINUTES FIRE RATED DOOR. CONSULTANT'S ENDORSEMENT
E. ADDED NEW FM 200 AND ELECTRICAL ROOM PROTECTION WAS REDUCED TO 1.0 HOUR FIRE RATED SUB-STATION
WALLS WITH 45 MINUTES FIRE RATED DOOR. OTHER AUTOMATIC SUPPRESSION SYSTEM GROUND FLOOR LEVEL - FM 200 CABINETS FOR LV & MV ROOMS
INDUSTRIAL
NA NA NA 2 DOORS
I, REGALADO M. BAJA AN ARCHITECT WITH UPDA REGISTRATION NO 3402 AS
F. ADDED NEW FM 200 AND ELECTRICAL ROOM PROTECTION WAS REDUCED TO 1.0 HOUR FIRE RATED TYPE AREAS PROTECTED (Esp. purpose) GRADE A, BEING THE CONSULTANT HEREBY CERTIFY THAT THE FIRE SAFETY
WALLS WITH 45 MINUTES FIRE RATED DOOR WATER SPRAY SYSTEM WORKS SHOWN ON THESE PLANS HAS BEEN DESIGNED IN ACCORDANCE WITH
G. ADDED NEW IDF ROOM PROTECTED WITH FM 200 SYSTEM AND 1.0 HOUR FIRE RATED WALLS WITH 45 THE PROVISIONS OF NFPA 101/5000 2015 EDITION, AND OTHER
WATER MIST SYSTEM TOTAL OCCUPANT LOAD 21 RELEVANT/APPLICABLE NFPA CODES AND STANDARDS AND LOCAL FIRE SAFETY
MINUTES FIRE RATED DOOR.
H. ADDED NEW PRE-ACTION ROOM PROTECTED WITH 1.0 HOUR FIRE RATED WALLS. CLEAN AGENT SUPPRESSION SYSTEM M.V. ROOM (SUBSTATION) CODES OR STANDARDS BEING IMPOSED QCD.
I. ADDED NEW FM 200 CABINET FOR ELECTRICAL ROOM & FIRE RATING OF WALLS WAS REDUCED TO 1.0 HOUR FOAM SYSTEM
DRY CHEMICAL SYSTEM FURTHER, I CERTIFY THAT I AM FULLY AWARE AND COMMIT MYSELF RESPONSIBLE
WITH 45 MINUTES FIRE RATED DOOR. TO THIS PROJECT AND ALL THE CONDITIONS PRESCRIBED UNDER THE EXISTING
J. ADDED NEW IDF ROOM PROTECTED WITH FM 200 SYSTEM AND 1.0 HOUR FIRE RATED WALLS. ELECTRICAL WET CHEMICAL SYSTEM LAW NO. 19 OF 2005, THE LAW REGULATING THE PRACTICE OF ENGINEERING
ROOM WAS ALSO PROTECTED WITH FM 200 SYSTEM AND FIRE RATING OF WALLS WAS REDUCED TO 1.0 KITCHEN/ RANGE HOOD EXTINGUISHING SYSTEM (AS PER NFPA 96) PROVISIONS IN THE STATE OF QATAR.
HOUR. OTHER, SPECIFY; ________________________
K. ADDED NEW IDF ROOM PROTECTED WITH FM 200 SYSTEM AND REARRANGED THE LAYOUT INSIDE MEP N/A AFFIXED IS MY SIGNATURE TO ATTEST WITH THE ABOVE UNDERTAKING.
SERVICES ROOM. FIRE RATING OF WALLS AND DOOR IS THE SAME OF PREVIOUS APPROVAL.
L. ADDED NEW MDF ROOM PROTECTED WITH FM 200 SYSTEM AND ENLARGED ELECTRICAL ROOM PROTECTED
WITH FM 200 SYSTEM AND 1.0 HOUR FIRE RATED WALLS AND DOOR.
3. ACCOMMODATION:
FIRE ALARM SYSTEM
M. ADDED NEW FM 200 SYSTEM FOR SERVICE ROOM AT GROUND FLOOR. AUTOMATIC FIRE ALARM SYSTEM Signature of Consultant
N. ADDED FM 200 SYSTEM FOR SERVICE ROOM AT FIRST FLOOR. MANUAL (call points / pull stations)
4. SUBSTATION: SMOKE ALARMS (standalone devices) P.O. Box No. 3973
O. ADDED NEW FM 200 SYSTEM FOR LV ROOM. Tel. No. +97444551188
N/A Fax. No. +97444551144
P. ADDED NEW FM 200 SYSTEM FOR MV ROOM.

BUILDING CLASSIFICATIONS (HABITABLE HEIGHT) : PREVIOUS QCD PLAN APPROVAL REF. NOS.: CONSULTANT'S SIGNATURE
SMOKE CONTROL SYSTEM
UPDA Reg. No. 3402 - Grade : "A" Qatar ID No.: 26560808814
HIGH-RISE BUILDING (28m) N/2016/0008068
FSD-/PS-/N-/M-/R- _________________ SMOKE MANAGEMENT (SHEVS)
MID-RISE BUILDING (>15m - <28m) N/A MECHANICAL NATURAL Validity : 20.12.2018 Validity : 01.07.2018
LOW-RISE BUILDING (<15m) APPLICATION: APPLICATION:
N/A CAR PARKS (Basement >500m² and/or >1 Level) CAR PARKS (Basement >500m² and/or >1 Level)
ENCLOSED PARKING STRUCTURES OPEN PARKING STRUCTURES EGRESS CAPACITY CALCULATION
WAREHOUSE STORAGE AREAS (>1115m²) WAREHOUSE STORAGE AREAS (>1115m²)
BUILDING DATA FACTORY MANUFACTURING AREAS (>1115m²) FACTORY MANUFACTURING AREAS (>1115m²)
810MM MINIMUM DOOR WIDTH
ATRIA ATRIA
MALLS (with floor openings connecting more than 2 levels ) MALLS
OTHERS, SPECIFY: _CENTRAL MARKET_ STAIRWELLS (Smoke Vents: 1.5m² fixed-wall
openings, max. 300mm below slab soffit)
N/A OTHERS, SPECIFY: ____________________
SMOKE CONTAINMENT N/A
ACTIVE SYSTEM (PRESSURIZATION)
HAZARD CLASSIFICATION: ORDINARY HAZARD APPLICATION:
NEW CONSTRUCTION: YES __X__ NO: _____ STAIRWELLS
AS-BUILT YES _____ NO: __X__ SMOKE-STOP LOBBIES
FIRE FIGHTING LOBBIES
REPAIR OF EXISTING: YES _____ NO: __X__ OTHERS, SPECIFY: __________________
RENOVATION OF EXISTING: YES _____ NO: __X__ N/A
MODIFICATION OF EXISTING: YES _____ NO: __X__
RECONSTRUCTION OF EXISTING: YES _____ NO: __X__ EMERGENCY POWER SUPPLY SYSTEM HEAD OF OFFICE SIGNATURE
CHANGE OF OCCUPANCY: YES _____ NO: __X__ DIESEL-ENGINE GENERATOR SET UPDA Reg. No. : 441 - Grade "A" Company Reg. Grade : A
CHANGE OF USE: YES _____ NO: __X__ OTHERS SPECIFY: ___________________
25.04.2019 10-1232-00
N/A DOORS /WINDOWS /OPENING SCHEDULES ( CENTRAL MARKET ) Validity : Qatar ID No. :
INTERIOR FIT-OUTS YES _____ NO: __X__ OWNER / CLIENT
FIRE PROTECTION
ADDITION TO EXISTING: YES _____ NO: __X__ TYPE/ DESIGNATION DESCRIPTION LOCATION
RATING
MULTIPLE OCCUPANCY YES _____ NO: __X__ GAS INSTALLATION
DOOR
- SEPARATED OCCUPANCY YES __X__ NO: _____ LIQUIFIED PETROLEUM GAS (LPG)
SINGLE-LEAF, SEMI SOLID TEAK WOOD PLANE PANELS IDF-1, MDF-1 ROOMS 45 MIN. RATING
D1
- MIXED OCCUPANCY YES _____ NO: __X__ OTHERS SPECIFY: ___________________ DOOR WITH TEAK WOOD FRAME. & ELECTRICAL ROOMS & 1.0 HR. RATING
N/A FIRE-RATED DOUBLE-LEAF SEMI-SOLID TEAK WOOD PLAIN DOOR W/ FIRE
INCIDENTAL USES: YES __X__ NO: _____ D2a RESISTANCE RATED VIEWING GLASS PANEL & PANIC DEVICE ON
MEP SERVICES ROOM
1.0 HR. RATING
& ELECTRICAL ROOM
TEAKWOOD FRAME W/ ARCHITRAVE, ALL PAINTED AS SPECIFIED.
SPECIFY:
SPECIAL STRUCTURE: YES _____ NO: __X__ OTHER FIRE AND LIFE SAFETY PROVISIONS
HISTORIC BUILDING: YES _____ NO: __X__
FIRE FIGHTING AND RESCUE PROVISIONS
FIRE LIFTS / FIRE SERVICE ACCESS ELEVATORS (28m habitable height and/or 9.0m depth of basements)
OTHERS: (Please specify other scope of works) AMBULANCE STRETCHER ACCOMMODATION ELEVATORS (18m habitable height; minimum car size
610mm x 2130mm in horizontal open position)
FIRE FIGHTING LOBBIES (in every fire lift provisions; min. size 6.0m², 2.0m. least side dimensions)
SMOKE-STOP LOBBIES (28m habitable height and/or 9.0m depth of basements;1.8m. least side dimensions)
AREA STATEMENT FIREMAN'S ACCESS PANELS (Bldgs.10m habitable height and in Factory & Storage Bldgs.of any height)
WINDOWS FOR RESCUE (In every room or space >23.2m² that is subject to student occupancy in Educational
P.O. Box : __________ Doha, State of Qatar__________
Occupancies & in every room or space subject to clients occupancy in Day-care Occupancies)

TOTAL PLOT AREA = 57,934.31 Sqm. FIRE ENGINE ACCESS ROADS (4.0m clear width / 4.5m unobstructed vertical clearance) Tel. : __________ Fax. : __________
FIRE ENGINE HARDSTANDING (min. size 6.0m x 15.0m; 45 ton stationary load capacity) E-mail. : __________
FIRE COMMAND CENTER (in high-rise buildings and in any provisions of smoke control and/or emergency
PROJECT TITLE
communication system; min. size 9m²)
OTHERS SPECIFY:______________________________________________________
______________________________________________________

SUBDIVISION OF BUILDING SPACES (SMOKE COMPARTMENTS/FIRE BARRIERS)


EDUCATIONAL OCCUPANCIES (with aggregate floor area of >2800m² and/or 91m building length or width;
smoke partitions:1-hr fire resistance rating)
HEALTHCARE OCCUPANCIES (two smoke compartments in every story used by inpatients for sleeping or LEGENDS AND SYMBOLS
treatment or any use with occupants >50; size limit of one compartment 2100m²; travel distance from any point
to a door in a smoke barrier, 61.0m; smoke barriers: 1-hr fire resistance rating)
AMBULATORY HEALTHCARE OCCUPANCIES (every story into not less than 2 smoke compartments; size
limit of one compartment 2100m², travel distance from any point to a door in a smoke barrier, 61.0m; smoke
barriers: 1-hr fire resistance rating) NEW CENTRAL MARKET
DETENTION AND CORRECTIONAL OCCUPANCIES (two smoke compartments in every story used for
sleeping by residents or other story with occupants >50; max. 200 residents in any smoke compartment; travel AL SAILIYA
distance from any room door required as exit access to a door in a smoke barrier, 46m; travel distance from any

TOTAL 29,278.46 Sqm.


point in a room to a door in a smoke barrier, 61.0m; smoke barriers: shall have structural fire resistance)
RESIDENTIAL OCCUPANCIES: HOTEL, DORMITORY AND APARTMENT BUILDINGS (guest rooms, guest
suite, dormitory rooms or apartment dwelling units, separated from each other by walls and floors constructed as
fire barriers of min.1-hour fire resistance rating or 1/2-hour fire resistance rating in buildings protected
throughout with automatic sprinklers system)
OTHERS SPECIFY: ___________________
BUILDING /TYPE OF CONSTRUCTION Note. Please mark/check the applicable provision (box) and show or demonstrate the provisions on Plans .
LOCATION : AL SAILIYA, QATAR PIN : 55730454

AREA : STREET : PLOT :

DRAWING TITLE
BUILDING/ TYPE OF CONSTRUCTION
REQUIRED SUBMISSION AFTER LIFE SAFETY PLAN APPROVAL
BASED ON THE THE CLASSIFICATION OF OCCUPANCY, HABITABLE HEIGHT & HAZARD CONTENTS,
FIRE FIGHTING (FF)
A MINIMUM TYPE OF CONSTRUCTION SHALL BE TYPE 2 (222) IN ACCORDANCE WITH
NFPA 5000 BUILDING CONSTRUCTION AND SAFETY CODE. FIRE ALARM (FA)
AIR CONDITIONING, VENTILATION AND SMOKE CONTROL SYSTEM
GAS SYSTEM INSTALLATION
N/A

COVER PAGE
(Life Safety)

REV. 1 PROJECT NO : 17027 DRAWING NUMBER

DATE : NOVEMBER 2017 SCALE : NTS BP-00