Professional Documents
Culture Documents
Ariston mtp1912f 81396110201 tb28656 Tech.m
Ariston mtp1912f 81396110201 tb28656 Tech.m
STN - CL - 0612.2 - EN
Indesit Company, Service Department
Autotest, Fault and temperature Allarm of new electronic platform L60 and L70
Title :
cooling products
Product Concerned
New electronic platform L60 and L70 Cooling products (models with main module on
the back of the product and interface module on the dashboard or on the door).
I.E.:BAN3, TAN3, MBL, MTP, MBP, MTL, MBT.
1. AUTOTEST:
2. FAULT:
1 . In case of Led Interface (see Fig.5 and Fig.6) through led ( see TAB1)
F12 Off On On
Fig.6 Ariston Led
F13 On On Off
F14 On Off On
F15 Off On On
F16 Off Off Off
2/8
Title : Autotest, Fault and temperature Allarm of new electronic platform L60 and L70 cooling products
Fault table:
F06 Triac driving defrost - Check the efficiency of the contacts on J6 connector on the board;
heating element short- - Check the ohm-continuity on the wiring connector J6 between pin 3 and 4;
circuit - Check defrosting heater connections and eventual short-circuits on the
connection box in the freezer compartment;
- Replace the heater;
- Replace the board.
F07 No power draw of - Check the efficiency of the contact on J6 connector on the board;
defrost heating element - Check ohm-continuity of the defrosting heater on wiring connector J6, between
pin 3 and 4,verifying that the ohm value displayed is coherent with the one in the
relative table;
-Check the correct connection of the defrosting heater and the drip tray on the
connection box of the freezer compartment;
- Check the correct ohm-value of the defrosting heater on the ends of it;
- Verify that thermal fuses do not open;
- Replace the defrosting heater;
- Replace the board.
4/8
Title : Autotest, Fault and temperature Allarm of new electronic platform L60 and L70 cooling products
F11 Motor fan triac in short -Check efficiency of contacts on PCB connector J6;
circuito (Combi NF models) - Check continuity on pins 1 and 2 of connector J6,
- Check connections fridge fan in the fridge;
- Replace fridge fan;
- Replace PCB
5/8
Title : Autotest, Fault and temperature Allarm of new electronic platform L60 and L70 cooling products
F13 Fridge Fan does not run (Combi - Check the efficiency of the contacts on connector J6 on the board;
NF) -Check ohm-continuity of fridge fan on pins 1 and 2 of connector J6, ensuring
that the value is compatible with the value given in the relevant table;
- Check correct connection of fridge fan;
- Check correct ohm-value of fridge fan;
- Replace fridge fan;
- Replace PCB.
F14 Faulty power PCB - Renew PCB.
F15 Heater multiflow triac in short - Check the efficiency of the contacts on connector J2 on the board;
circuit -Check ohm-continuity on the cable connector on pin 1 and 3 of connector J2 pin
3 e 1 ensuring that the value is compatible with the value given in the relevant
table;
- Check the presence of short circuits on the Multiflow heater inside the fridge;
- Replace Multiflow heater;
- Replace main board.
F16 Freezer fan does not run (static - Check efficinecy of contacts of PCB connector J2;
models) - Check impedance on pins 3 and 1 of connector J2, ensuring that the value is
Multiflow Heater doesn t start compatible with the value given in the relevant table;
(models NO-FROST) - Check correct connection of the fridge fan (Multiflow heater) in the fridge
compartment
- Renew fridge fun unit ( Multiflow heater);
- Renew main PCB.
F17 Vacuum pump unit does not run - Check efficiency of contacts of PCB connector J4;
(Ever fresh models) - Check impedance on pins 1 and 2 of connector J4, ensuring that the value is
AQUA CARE1 electrovalve compatible with the value given in the relevant table;
doesn t start (Aqua Care models) - Renew vacuum pump or Aqua Care1 electrovalve;
- Renew main PCB.
F18 Aqua Care2 electrovalve doesn t - Check the efficiency of contacts of connector J10 on the board;
start - Check the continuity of electrovalve on pins 3 and 4 of connectors J10,
ensuring that the value is compatible with the value given in the relevant table;
- Check the correct connection of AQUA CARE2 electrovalve;
- Check the correct ohm-value of AQUA CARE 2 electrovalve;
- Replace AQUA CARE 2 electrovalve;
- Replace PCB.
F20 Fridge lamp fails to switch on - Check efficiency of contacts of PCB connector J2;
- Check impedance on pins 4 and 6 of connector J2;
- Renew lamps;
- Renew main PCB.
F21 NTC ambient sensor UI - Replace the board.
F22 FRIDGE Air NTC sensor open / - Check the efficiency of the contacts on connector J11 on the board;
short circuit - Check NTC sensor, verifying if the resistance value of the wiring connector
J11, between pin 3 and 4, is coherent with the one in the temperature-resistance
table (warm the sensor touching it, if possible, and check how the resistance
value changes);
- Replace the board.
6/8
Title : Autotest, Fault and temperature Allarm of new electronic platform L60 and L70 cooling products
F23 FRIDGE Evaporator NTC sensor open / - Check the efficiency of the contacts on connector J11 on the board;
short circuit - Check NTC, verifying if the resistance value of the wiring connector
J11, between pin 1 and 2, is coherent with the one in the temperature-
resistance table (warm the sensor touching it, if possible, and check
how the resistance value changes);
- Replace the board;
- Replace the product.
F24 FREEZER Air NTC sensor open / short -Check the efficiency of the contacts on J11 connector on the board;
circuit - Check NTC, verifying if the resistance value of the wiring connector
J11, between pin 5 and 6, is coherent with the one in the temperature-
resistance table (warm the sensor touching it, if possible, and check
how the resistance value changes);
- Replace the board.
F25 FREEZER Evaporator NTC sensor open / - Check the efficiency of the contacts on J11 connector on the board;
short circuit - Check NTC, verifying if the resistance value of the wiring connector
J11, between pin 1 and 2, is coherent with the one in the temperature-
resistance table (warm the sensor touching it, if possible, and check
how the resistance value changes);
- Replace the board.
F26 CCZ Air NTC sensor open / short circuit - Check efficiency of contacts of PCB connector J12;
- Check NTC sensor, ensuring that the impedance value read on pins 3
and 4 of connector J11 is compatible with the values in the
temperature-impedance correlation table (also heat the sensor by
holding it with your hand where possible and check the change in the
impedance value);
- Renew main PCB.
F28 Display PCB does not work - Renew display PCB
F40 ON/OFF button does not work - Renew touch display PCB
F41 I Care button does not work - Renew touch display PCB
F42 Holiday button does not work - Renew touch display PCB
F43 Ice Party button does not work - Renew touch display PCB
F44 Ever Fresh button does not work - Renew touch display PCB
F45 Super Freeze button does not work - Renew touch display PCB
F46 Super Cool button does not work - Renew touch display PCB
F47 Allarm button does not work - Renew touch display PCB
F49 FRIGO + button does not work - Renew touch display PCB
F50 FRIGO - button does not work - Renew touch display PCB
F51 CCZ button does not work - Renew touch display PCB
F52 FREEZER + button does not work - Renew touch display PCB
F53 FREEZER - button does not work - Renew touch display PCB
7/8
Title : Autotest, Fault and temperature Allarm of new electronic platform L60 and L70 cooling products
A1= is activated when freezer temperature is higher than 2°C, or when it varies
from 6°C to 2°C for more than 4 hours.
Food in this case could be used.
A2= is activated when freezer temperature is higher than 8°C, or when the Allarm
A1 has being active for more than 5 days.
Food in this case has to be thrown away.
A1
Super Frigo Led Linea Led Super Freezer Led Super Frigo Led Linea Led Super Freezer Led