Capacity:- 400 Nm3/hr

Electrical Load:- 77 KW
LOG SHEET OF EXO GAS PLANT
SL. NO SPECIFICATION P.V S.V
1 VOLTAGE
2 COOLING WATER Pr. (Kg/Cm2) 1.5
3 AIR BLOWER FLOW (Nm3/Hr.) 400
4 AIR BLOWER Pr. (Kg/Cm2) 0.2
5 LPG Pr. BEFORE REGULATOR (MMWC) 1
6 LPG FLOW (Nm3/Hr.) 18.4
7 LPG Pr. AFTER REGULATOR (MMWC) 2300
8 COMBUSTION CHAMBER BOTTOM TEMP (*C) 50
9 COMBUSTION CHAMBER TOP TEMP (*C) 55
10 WATER SCRUBBER TOP TEMP(*C) 40
11 SUCTION POT Pr. (MMWC) 1400
12 GAS BLOWER DISCHARGE Pr (Kg/Cm2) 0.3
13 CHILLING UNIT TEMP. UNIT-I (*C) 7
14 CHILLING UNIT SUCTION Pr. UNIT-I (Kg/Cm2)
15 CHILLING UNIT DISCHARGE Pr. UNIT-I (Kg/Cm2)
16 CHILLING UNIT TEMP. UNIT-II (*C) 7
17 CHILLING UNIT SUCTION Pr. UNIT-II (Kg/Cm2)
18 CHILLING UNIT DISCHARGE Pr. UNIT-II (Kg/Cm2)
19 DE OXO TOWER TEMP. (De oxo TIC) 70
20 TWIN POINT TIC TEMP. (Gas dryer heater) 190
21 GAS DRYER Pr. TOWER-I (Kg/Cm2) 0.2
22 GAS DRYER Pr. TOWER-II (Kg/Cm2)
23 GAS DRYER TOP TEMP. TOWER-I (*C) 55
24 GAS TEMP BOTTOM TEMP. TOWER-I (*C) 40
25 GAS DRYER TOP TEMP. TOWER-II (*C) 160
26 GAS TEMP BOTTOM TEMP. TOWER-II (*C) 120
27 RATIO 19
28 O2 PPM. 5
29 H2 (%) 9.9
30 DEW POIN (-) *C. 50