DDD V4383

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

TOWER WORKS

SITE ID: V4383


SEARCH RING NAME: -
SITE NAME: SUN-KABANKALAN CITY-ORINGAO
AREA: -
PROVINCE: -
TOWN: -
BARANGAY: -

SITE DETAILS

OWNER'S NAME:
INDEX
OWNER CONTACT NUMBER: SITE SPECIFIC DRAWINGS

NO. SHEET NAME SHEET NO.


SITE ACCESS PROCEDURE: -
1 COVER PAGE SV
2 TOWER RETRO DETAILS SV-1
SITE ADDRESS: -
3 TOWER RETRO DETAILS SV-2
4 TOWER RETRO DETAILS SV-3
TECHNOLOGY: 5 TOWER RETRO DETAILS SV-4
6 TOWER RETRO DETAILS SV-5
3 KM (BEACONING PAINTING REQUIRED FOR TOWER)
DISTANCE FORM
NEAREST AIRPORT: 3 KM

EXPOSURE CLASSIFICATION: "C"


"D" (IF DISTANCE FROM COASTLINE 2KM)

HEIGHT ABOVE SEA LEVEL:

WIND SPEED ZONE:

EXPECTED MAXIMUM FLOOD


WATER HEIGHT ABOVE E.G.L:

DESIGNED BY :
OWNER : OWNER'S REPRESENTATIVE : CONTRACTOR : PROJECT NAME : TOWER WORKS SHEET CONTENTS : REVISIONS : SHEET NO.
-
SITE ID : V4383
CIVIL / STRUCTURAL ENGINEER DRAWN BY :
SITE NAME :
ZHANGPENG
SUN-KABANKALAN CITY-ORINGAO
-- CHECKED BY :
PTR NO : PRC NO : LOCATION :
-
DATE ISSUED: TIN NO : LA-CARLOTA-LA CASTELLANA ROAD, LA DATE :
CARLOTA CITY, NEGROS OCCIDENTAL 01/27/21
PLACE ISSUED :
SPLICE SCHEDULE
INNER OUTER
INNER OUTER
LABEL T T BOLTS REMARKS
A. DESIGN CRITERIA (mm) (mm) (mm) (mm)
1. DESIGN STANDARDS : NATIONAL STRUCTURAL CODE OF THE PHILIPPINES SPL-1 880x180 880x170 12 12 16-20Ø SINGLENUT
(7TH EDITION) & TIA/EIA-222-G" STRUCTURAL STANDARD H11
SPL-2 880x180 880x170 12 12 16-20Ø SINGLENUT
FOR STEEL ANTENNA TOWERS & ANTENNA H10
SPL-3 870x150 870x170 12 12 16-16Ø SINGLENUT
SUPPORTING STRUCTURES. D11
2. WIND SPEED : 260Kph SPL-4 870x130 870x150 10 10 16-16Ø SINGLENUT
3. EXPOSURE CLASSIFICATION : C" - OPEN TERRAIN WITH SCATTERED OBSTRUCTIONS H9 TL-12 SPL-5 780x130 780x140 10 10 16-16Ø SINGLENUT
HAVING HEIGHTS LESS THAN 30ft (9.1m). THIS INCLUDES D10 SPL-6 680x120 680x130 8 8 16-16Ø SINGLENUT
FLAT, OPEN COUNTRY, GRASSLANDS AND SHORELINES IN 8 8 SINGLENUT
H8 SPL-7 670x120 670x130 14-16Ø
HURRICANE PRONE REGIONS. SP-11
D9 SPL-8 640x120 640x120 8 8 16-16Ø SINGLENUT
4. CAPABLE ANTENNA LOADING :
SPL-9 600x120 600x110 8 8 16-16Ø SINGLENUT
H7 MAIN DIAGONAL
D8 SPL-10 550x100 550x90 8 8 16-16Ø SINGLENUT
TL-11 SPL-11 540x80 540x90 8 8 12-16Ø SINGLENUT
D7 12-30mmØ ANCHOR BOLTS
H6
TOWER MEMBER SCHEDULE 20mmTHK BASE PLATE
H5 SP-10 MEMBER BOLT STIFFERNER
SECTION
CODE START END PLATE
D6 TL-10 TOWER LEG
MAIN DIAGONAL
SP-9 T1 to T3 L175x175x15 THK SEE SPLICE SCHEDULE -
T4 to T5 L150x150x12 THK SEE SPLICE SCHEDULE -
T6 L140x140x12 THK SEE SPLICE SCHEDULE -
T7 L130x130x11 THK SEE SPLICE SCHEDULE -
TL-9
T8 to T10 L120x120x10 THK SEE SPLICE SCHEDULE - 1000x1000x530HT.
T11 to T12 L90x90x6 THK SEE SPLICE SCHEDULE -
SP-8
BOLT
H4 DIAGONAL GUSSET PLATE
D1 L90x90x6THK 3-16mm 3-16mm 10mm THK
TL-8 MAIN LEG
D5 SP-7 D2 L60x60x6THK 2-16mm 2-16mm 10mm THK
D3 to D11 L70x70x6THK 2-16mm 2-16mm 10mm THK

HORIZONTAL CENTER GUSSET

L45x45x5THK
L60x60x5THK
PLATE
H1 L90x90x6THK 2-16mm 2-16mm 10mm THK
TL-7 H2 L80x80x6THK 2-16mm 2-16mm 10mm THK SPLICE 1
H3 L70x70x6THK 2-16mm 2-16mm 10mm THK
H4 to H5 L80x80x8THK 2-16mm 2-16mm 10mm THK
SP-6 2-16mm 2-16mm 10mm THK MAIN DIAGONAL
H6 to H8 L50x50x5THK
H3 H9 L80x80x6THK 2-16mm 2-16mm 10mm THK
TL-6 H10 to H11 L50x50x5THK 2-16mm 2-16mm 10mm THK
D4
MAIN LEG

BOLTS(SEE SCHD)
SPLICE PLATE & BOLTS
SP-5 (SEE SPLICE SCHD)
TL-5

12-30mmØ ANCHOR BOLTS


50mmTHK BASE PLATE
MAIN DIAGONAL
H2
SP-4
D3 BOLTS (SEE SCHD)
MAIN DIAGONAL
1000x1000x530HT.
5. ALLOWABLE TWIST : 1° MAXIMUM TL-4 MAIN LEG
6. ALLOWABLE SWAY : 1° MAXIMUM
DETAIL C
B. MATERIALS SPECIFICATIONS
1. STEEL PIPES SHALL CONFORM TO ASTM A53 GRADE B WITH Fy= 241MPa.
SP-3
DETAIL C DETAIL D
L80x80x6THK
L80x80x6THK

2. STEEL SHAPES SHALL CONFORM TO ASTM A36 WITH


Fy= 248MPa and Fu= 400MPa. TL-3
3. COMPRESSIVE STRENGTH OF CONCRETE AT 28 DAYS.
D2 DETAIL E DETAIL B
fc'= 21MPa. MAIN LEG
H1
4. REINFORCEMENT/DEFORMED BARS CONFORMING TO
SP-2 MAIN
ASTM A615 WITH Fy= 275MPa. D1 REDANDUNT DIAGONAL
5. ANCHOR BOLTS SHALL CONFORM TO ASTM A307 WITH
Fu= 414MPa.
6. CONNECTION BOLTS SHALL CONFORM TO ASTM A325 WITH BOLTS (SEE SCHD) BOLTS(SEE SCHD)
Fy= 620MPa AND Fu= 827 MPa FOR 12mmØ UP TO 25mmØ BOLT SIZE. TL-2
7. WELDING CONNECTION SHALL CONFORM TO E70xx. BOLTS (SEE SCHD) MAIN HORIZONTAL
4-16mmØ BOLTS
SP-1 MAIN FOR CENTER GUSSET PLATE
DETAIL D HORIZONTAL
TL-1
SEC.HOR
REDUNT

C-BAR
C-BAR 1 150x70x10THK CENTER GUSSET PLATE
C-BAR 2 TO C-BAR 4 10mm THK
150x80x10THK
C-BAR 5 100x50x10THK
TOWER ELEVATION DETAIL B DETAIL E
DESIGNED BY :
OWNER : OWNER'S REPRESENTATIVE : CONTRACTOR : PROJECT NAME : TOWER WORKS SHEET CONTENTS : REVISIONS : SHEET NO.
-
SITE ID : V4383
CIVIL / STRUCTURAL ENGINEER DRAWN BY :
SITE NAME :
ZHANGPENG
SUN-KABANKALAN CITY-ORINGAO
-- CHECKED BY :
PTR NO : PRC NO : LOCATION :
-
DATE ISSUED: TIN NO : LA-CARLOTA-LA CASTELLANA ROAD, LA DATE :
CARLOTA CITY, NEGROS OCCIDENTAL 03/18/21
PLACE ISSUED :
A. GENERAL
RETRO SCHEDULE
1. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS OTHERWISE
SHOWN OR NOTED, MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL CONDITIONS.
PLATE EXISTING ADDITIONAL REPLACE
2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL STEEL, MISC. DIAGONAL SIZE LENGTH QTY.
HORIZONTAL
IRON, PRECAST CONCRETE ETC. SHALL BE SUBMITTED FOR ENGINEERS APPROVAL BEFORE (inch) (mm) (PCS.)
FABRICATION.

3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN, CHECK WITH
MECHANICAL & ELECTRICAL CONTRACTORS FOR CONDUITS, PIPE SLEEVES, ETC. TO BE
EMBEDDED IN CONCRETE.

4. IT SHALL BE CONTRACTORS RESPONSIBILITY TO PROVIDE ADEQUATE SHORING & BRACING OF


THE STRUCTURE FOR ALL LOADS THAT MAYBE IMPOSED DURING CONSTRUCTION.

5. FINISHED FLOOR LINE SHOULD BE ATLEAST 0.3M FROM MAXIMUM SITE FLOOD LEVEL.

6. UNLESS OTHERWISE NOTED ALL EXTERNAL STEEL SHOULD BE HOT DIP GALVANIZED.

B. STRUCTURAL STEEL

STRUCTURAL STEEL - STEEL TO BE USED FOR FABRICATION AND ERECTION OF THIS STRUCTURE
SHALL COMPLY WITH ALL THE PERTINENT PROVISION OF ANSI/AISC 360-16 SPECIFICATION FOR
STRUCTURAL STEEL BUILDINGS 2016 Ed. AND NSCP 2015 7th Ed. Vol 1. BUILDINGS, TOWERS AND
OTHER VERTICAL STRUCTURES.

a. STEEL PIPES

b. STEEL SHAPES
WIDE FLANGE, ANGLES, CHANNELS, PLATES SHALL BE ASTM A36 WITH YIELD
STRENGTH OF 248 MPa AND ULTIMATE STRENGTH OF 400 MPa UNLESS OTHERWISE
INDICATED.

c. BOLTS
ALL BOLTS, NUTS AND WASHERS SHALL CONFORM TO ASTM A307 OR A325 UNLESS
OTHERWISE INDICATED. ANCHOR BOLTS SHALL LIKEWISE BE OF EQUAL STRENGTH
AS A325 BOLTS OF THE SAME SIZE.

d. WELDS
ALL WELDS SHALL BE IN ACCORDANCE WITH AWS STRUCTURAL WELD CODE D1-1
LATEST REVISION FOR SHIELDED METAL ARC WELDING PROCESS, ELECTRODES
E-70 SHALL CONFORM TO AWS AS-1 FOR LATEST EDISTION SUBMERGED ARC
WELDING PROCESS MAYBE USED AT OPTION OF FABRICATOR UPON THE APPROVAL
OF ENGINEER.

ADD'L DIAGONAL
C. QUALITY CONTROL
1. REFER TO SPECIFICATIONS FOR QUALITY CONTROL TESTING REQUIREMENTS.

2. STEEL SHAPES
EVERY BATCH OF STRUCTURAL STEEL SHAPE FOR FABRICATION SHALL HAVE THE
MANUFACTURERS MILL CERTIFICATE SHOWING THEIR CHEMICAL AND PHYSICAL PROPERTIES,
OWNER EXERCISES THE RIGHT TO UNDERTAKE DESTRUCTIVE OR NON-DESTRUCTIVE
TESTING OF SAMPLES FROM MATERIALS USED FOR THE PROJECT.

3. BOLTS EXISTING DIAGONAL


a. MINIMUM EDGE DISTANCE:
THE MINIMUM EDGE DISTANCE OF BOLTS SHALL CONFORM TO THE REQUIREMENTS
OF AISC STEEL CONSTRUCTION MANUAL 14th Ed.

b. MAXIMUM EDGE DISTANCE: ADD'L DIAGONAL


THE MAXIMUM EDGE DISTANCE FROM BOLT CENTER SHALL BE 12 TIMES THICKNESS
OF THE PLATE BUT NOT TO EXCEED 150mm.

c. MINIMUM PITCH:
ON CENTER SPACING OF BOLTS SHALL NOT BE LESS THAN 3 TIMES THE NOMINAL
DIAMETER.

d. ALL BOLT HOLES SHALL BE DRILLED OR PUNCHED TO EXACT LOCATION 1.5mm


GREATER THAN THE BOLT DIAMETER.

D. TOLERANCES
SOME VARIATIONS EXPECTED IN THE FINISH OVERALL DIMENSIONS OF FRAMES SHALL NOT EXCEED
THE ROLLING TOLERANCES FOR CROSS SECTIONAL DIMENSIONS. CAMBER AND SWEEP PERMITTED
UNDER ASTM SPECIFICATIONS A36.

LEGEND:

EXISTING
RETROFIT
TOWER ELEVATION
DESIGNED BY :
OWNER : OWNER'S REPRESENTATIVE : CONTRACTOR : PROJECT NAME : TOWER WORKS SHEET CONTENTS : REVISIONS : SHEET NO.
-
SITE ID : V4383
CIVIL / STRUCTURAL ENGINEER DRAWN BY :
SITE NAME :
ZHANGPENG
SUN-KABANKALAN CITY-ORINGAO
-- CHECKED BY :
PTR NO : PRC NO : LOCATION :
-
DATE ISSUED: TIN NO : LA-CARLOTA-LA CASTELLANA ROAD, LA DATE :
CARLOTA CITY, NEGROS OCCIDENTAL 03/18/21
PLACE ISSUED :
ADD'L 30mmTHK.
BASE PLATE

ADD'L BASE PLATE

ADD'L TOP PLATE

ADD'L 10mmTHK.
BASE PLATE

ADD'L 8-24mmØ
ANCHOR BOLT

26mmØ BOLT HOLE

PLAN VIEW

ASSEMBLY DETAIL
8-24mmØ ANCHOR BOLTS
NOTES FOR RETROFITTING AND REPAIR WORKS:
ADD'L 10mmTHK TOP PLATE
1. ALL RUSTED SURFACE OF TOWER MEMBERS, PLATES AND BOLTS SHALL BE REMOVED OF RUST.
AFTERWARDS APPLY GALVANIZING COATING AND THEN 2 COATS OF EPOXY PRIMER.
ADD'L 30mmTHK BASE PLATE THE TOWER PARTS SHALL FINISHED WITH PAINT OF THE SAME COLOR BASED ON THE EXISTING SCHEME.
2. TEMPORARY SUPPORT SHALL BE INSTALLED PRIOR TO REMOVAL AND REPLACEMENT OF AFFECTED
MEMBER/S.
LEVELING NUT 3. ALL DIMENSION SHOWN ESPECIALLY SPACING OF HOLES FOR CONNECTION BOLTS HAS TO BE VERIFIED
ON SITE TO ENSURE PROPER IMPLEMENTATION IN DRILLING OF BOLT HOLES.
CONCRETTE 4. SHOULD THE RECOMMENDED REMEDIAL MEASURES NOT SUITABLE IN THE ACTUAL IMPLEMENTATION.
POURING THE ENGINEER AT SITE SHOULD CONSULT THE DESIGNER FOR PROPER GUIDANCE OR INSTRUCTION.

USE HIT-RE 500 V3


EPOXY MORTAR FOR MAIN DIAGONAL
1. INSTALL TEMPORARY SUPPORT BRACING FOR THE AFFECTED TOWER MEMBER.
2. INSTALL ADITIONAL DIAGONAL MEMBER TO MAKE A DOUBLE ANGULAR DIAGONAL.
3. TIGHTEN BOLTS AS PER STANDARD TORQUE.
4. DISMANTLE THE TEMPORARY SUPPORT BRACING.

FOR ANCHOR BOLTS & CONCRETE PEDESTAL


1. EXCAVATE AFFECTED SOIL FOR CONCRETE POURING WITH A SPECIFIED DEPTH
2. DRILL HOLES IN THE EXISTING PEDESTAL THEN APPLY SPECIFIED EPOXY MORTAR FOR DOWEL INSTALLATION
3. INSTALL FORMS. THEN INSTALL SPECIFIED REBARS FOR LATERAL TIES
4. USE STEEL BAR TO HOLD STUD BOLT THEN PERFORM CONCRETE POURING.
5. LET THE CAST-IN CONCRETE REACH ITS MAXIMUM COMPRESSIVE STRENGTH WITH A SPECIFIC SETTING TIME. THEN REMOVE FORMS
ADD' BASE PLATE
FOR BASE PLATE:

1. REMOVE EXISTING NUTS FOR THE AFFECTED ANCHOR BOLTS


2. INSTALL PROPOSED RETROFITTING BASEPLATE (SEE RETRO DETAILS)
ELEVATION VIEW 3. TIGHTEN ANCHOR BOLTS AS PER STANDARD TORQUE

A TOWER ELEVATION
S-4 SCALE: 1:250m
DESIGNED BY :
OWNER : OWNER'S REPRESENTATIVE : CONTRACTOR : PROJECT NAME : TOWER WORKS SHEET CONTENTS : REVISIONS : SHEET NO.
-
SITE ID : V4383
CIVIL / STRUCTURAL ENGINEER DRAWN BY :
SITE NAME :
ZHANGPENG
SUN-KABANKALAN CITY-ORINGAO
-- CHECKED BY :
PTR NO : PRC NO : LOCATION :
-
DATE ISSUED: TIN NO : LA-CARLOTA-LA CASTELLANA ROAD, LA DATE :
CARLOTA CITY, NEGROS OCCIDENTAL 03/18/21
PLACE ISSUED :
DESIGNED BY :
OWNER : OWNER'S REPRESENTATIVE : CONTRACTOR : PROJECT NAME : TOWER WORKS SHEET CONTENTS : REVISIONS : SHEET NO.
-
SITE ID : V4383
DRAWN BY :
CIVIL / STRUCTURAL ENGINEER SITE NAME :
ZHANGPENG
SUN-KABANKALAN CITY-ORINGAO
-- CHECKED BY :
PTR NO : PRC NO : LOCATION :
-
DATE ISSUED: TIN NO : LA-CARLOTA-LA CASTELLANA ROAD, LA DATE :
CARLOTA CITY, NEGROS OCCIDENTAL 03/18/21
PLACE ISSUED :

You might also like