Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 8

ENVIRONMENTAL ENGINEERING LABORATORY

ECW 568
OPEN-ENDED LAB REPORT

TITLE OF EXPERIMENT: NOISE LEVEL


DATE OF EXPERIMENT: 19 OCTOBER 2022
GROUP : 1
GROUP MEMBERS 1. ALIFQAYOUM AFEEF BIN HISHAM
2. ALISTER ISAAC
3. NUR AHMAD SYAKIRIN BIN SHARIBUDDIN
4. RABIATUL NORAFIZAH BINTI RASLIM
5. SYAFIQAH NABILAH BINTI MOHD FADZLI

LECTURER : TS. SITI NURULHUDA BINTI MOHD IMRAN


LEVEL OF OPENESS : 1

MARKS COMMENTS
INTRODUCTION
BASIC CONCEPTS
METHODOLOGY
RESULTS&ANALYSIS 1 2 3 4 5
DISCUSSION 1 2 3 4 5
CONCLUSION 1 2 3 4 5
ORGANIZATION 1 2 3 4 5

TOTAL MARKS
Data and Analysis
Table 1: Noise reading of location A, B, C and D within 10 minutes at intervals of 30 seconds.

Noise Reading (dB)


Time (seconds) Location A Location B Location C Location D
30 48.2 81.7 84.3 83.5
60 49.2 85.7 79.2 89.1
90 49.3 82 81 89.1
120 49.3 80.4 82 98.6
150 77.4 78.5 84.3 96
180 64.7 71.6 87.6 89.9
210 84.3 76.8 86.4 88.7
240 84.4 86 91 102.2
270 78.9 86 88.4 94.6
300 81.1 82.6 83.3 91.7
330 81.9 78.3 87.7 96.3
360 78.2 78.7 91 97.6
390 85 75.9 90.7 93.8
420 78.7 80.2 95.2 101.9
450 84.5 81.2 89.9 92.6
480 83.6 79.1 85.1 95.1
510 86.1 79.9 78.3 94.5
540 89.4 76.9 81.3 87.2
570 96.2 76.8 84.8 92.8
600 84.4 79.6 78.5 100.4
Table 2: Minimum and Maximum Reading of Location A, B, C, and D.

Noise
Reading in 10 Location Min Max
minutes
A Faculty's Cafeteria 48.2 96.2
B Faculty's PTAR 71.6 86
C College Melati's Front Gate 78.3 95.2
D Dataran Cendiakawan's Bus Stop 83.5 102.2

Using the received data, a graph of noise readings (dB) at Locations A, B, C, and D against
time was created.
Calculation
Conclusion

You might also like