Nilai K Di Atas Normal, Mengindikasikan Masuknya Cairan Pendingin Ke Oli. Kemungkinan Terjadi Kerusakan Pada Seal Water Pump,
Cylinder Head Retak/Bengkok Atau Gasket Rusak. Cu, Si And Al High. Kemungkinan Berasal Dari Kontaminasi Part/Assembly Yang
Baru. Unit Masih Dalam Break-In Period. Segera Cari Sumber Masuknya Cairan Pendingin, Periksa Kekurangan Coolant. Periksa
Kerusakan Seal Water Pump, Periksa Kebocoran Pada Cylinder Head Gasket/Seal. Segera Lakukan Perbaikan. Ambil Sample Kembali
Saat Oli Mecapai 100 Jam Untuk Memonitor. Bilas Sistem Pelumasan Untuk Menghilangkan Kontaminan.
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component
Oil Analysis Report Page 1 of 2
ENGINE
J21A-52138-0424
SERIAL NUMBER: 30218000086
EQUIP NUM: DP014
Action Required
UNKNOWN UNKUNKNOWN_UNKNOWN
REPORT COMMENT
THE ANALYSIS PROVIDED ARE INDICATIVE OF CONDITIONS BASED UPON SAMPLE INFORMATION RECEIVED AND THE QUALITY OF SAMPLE SUPPLIED.
RECOMMENDATIONS ARE PROVIDED AS A GUIDE ONLY. ANY DECISION TO REPAIR COMPONENTS IS ENTIRELY AT THE CUSTOMER'S DESCRETION. KINDLY ADVISE
YOU TO CONTACT US PRIOR TO 7 DAYS AFTER REPORT RELEASE SHOULD YOU NEED FURTHER DISCUSSION ABOUT THIS SAMPLE. ----- ANALISA INI BERSIFAT
INDIKASI, BERDASARKAN INFORMASI DARI LABEL & SAMPLE YG DI KIRIMKAN. JIKA ADA KEPUTUSAN PERBAIKAN COMPONENT SEPENUHNYA KEBIJAKAN CUSTOMER.
DISARANKAN AGAR DISKUSI LEBIH LANJUT MENGENAI SAMPLE INI HARUS DILAKUKAN SEBELUM 7 HARI DARI TANGGAL LAPORAN DI TERBITKAN.
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component
Oil Analysis Report Page 2 of 2