Natural ventilation and air movement has three distinctly different functions:
1. Supply of fresh air
2. Convective cooling
3. Physiological cooling
There is a radical difference in the form of provisions for 1 and 2 and for 3: therefore, the first
two functions will be considered as ‘ventilation’ but the last function is considered separately as
‘air movement’.
Ventilation, i.e. both the supply of fresh air and convective cooling, involves the movement of
air at a relatively slow rate. The motive force can be either thermal or dynamic (wind).
The stack effect relies on thermal forces set up by density difference (caused by temperature
differences) between the indoor and outdoor air. It can occur through an open window (when the
air is still): the warmer and lighter indoor air will flow out at the top and the cooler, denser
outdoor air will flow in at the bottom. The principle is the same as in wind generation.
Special provision can be made for it in the form of ventilating shafts. The higher the shaft, the
larger the cross-sectional area and the greater the temperature difference: the greater the motive
force therefore, the more air will be moved.
The motive force is the stack pressure multiplied by the cross-sectional area (force in Newtons –
area in m²). The stack pressure can be calculated from the equation.
Ps = 0.042 x h x ∆T
where Ps = stack pressure in N/m².
h= height of stack in m
∆T temperature difference in degC
(The constant is N/m³ deg C)
Such shafts are often used for the ventilation of internal, windowless rooms (bathrooms and
toilets) in Europe.
Physiological cooling:
The movement of air past the skin surface accelerates heat dissipation in two ways:
1. Increasing convective heat loss
2. Accelerating evaporation
On the basis of such experimental observations the following factors can be isolated which affect
the indoor air flow (both patterns and velocities):
a) Orientation
b) External features
c) Cross-ventilation
d) Position of openings
e) Size of openings
f) Controls of openings
Orientation:
The greatest pressure on the windward side of a building is generated when the elevation is at
right angles to the wind direction, so it seems to be obvious that the greatest indoor air velocity
will be achieved in this case. A wind incidence of 45 degree would reduce the pressure by 50%.
It has however, been found by Givoni that a wind incidence at 45 degree would increase the
average indoor air velocity and would provide a better distribution of indoor air movement.
This seems to contradict common sense and the findings of others, but it can be explained by the
following phenomenon
The first figure shows the outline of air flows at 90 degree and the second figure at 45 degree, to
a building square in plan. In the second case a greater velocity is created along the windward
faces, therefore the wind shadow will be much broader, the negative pressure (the suction effect)
will be increased and the increased indoor air flow will result.
External features:
Wind shadows created by obstructions upwind, should be avoided in positioning the building on
the site and in positioning the openings in the building.
External features of the building itself can strongly influence the pressure build-up. For example
, if the air flow is at 45 degree to an elevation, a wind-wall at the downwind end or a projecting
wing of an L shaped building can more than double the positive pressure created by upward
projecting eaves. Any extension of the elevational area facing the wind will increase the pressure
build-up. If a gap between two buildings is closed by a solid wall, similar effect will be
produced.
The air velocity between free standing trunks of trees with large crowns can be increased quite
substantially due to similar reasons.
The opposite of the above means will produce a reduction of pressures: if a wing wall or the
projecting wing of an L-shaped building is upwind from the opening considered, the pressure is
reduced or even a negative pressure may be created in front of the window.
Cross-ventilation:
In the absence of an outlet opening or with a full partition there can be no effective air movement
through a building even in case of strong winds. With a windward opening and no outlet, a
pressure similar to that in front of the building will be built up indoors, which can make
conditions even worse, increasing discomfort. In some, oscillating pressure changes, known as
‘buffeting’ can also occur. The latter may also be produced by an opening on the leeward side
only, with no inlet.
Air flow loses much of its kinetic energy each time it is diverted around or over an
obstacle. Several right-angle bends, such as internal walls or furniture within a room can
effectively stop a low velocity air flow.
Position of openings:
Air movement must be ensured through the space mostly used by the occupants: through the
‘living zone’ (up to 2 m high). As the figure shows, if the opening at the inlet side is at a high
level, regardless of the outlet opening position, the air flow will take place near the ceiling and
not in the living zone.
In a two storey building the air flow on the ground floor may be satisfactory but on the upper
floor it may be directed against the ceiling. One possible remedy is an increased roof parapet
wall.
Size of openings:
The largest air velocity will be obtained through a small inlet opening with a large outlet. This is
partly due to the total force acting on a small area, forcing air through the opening at a high
pressure, and partly due to the ‘venturi effect’: in the broadening funnel (the imaginary funnel
connecting the small inlet to the large outlet) the sideways expansion of the air jet further
accelerates the particles.
Control of openings:
Sashes, canopies, louvres and other elements controlling the openings, also influence the indoor
air flow pattern.
Sashes can divert the airflow upwards. Only a casement or reversible pivot sash will channel it
downwards into the living zone.
Louvres and shading devices may also present a problem. The position of blades in a slightly
upward position would still channel the flow into the living zone (upto 20 degrees upwards from
the horizontal).
Screens and nets can substantially reduce the air flow. A cotton net can give a reduction of 70%
in air velocity.
In a rural setting in open country, single story buildings are placed in rows in a grid iron pattern,
stagnant air zones leeward from the first row will overlap the second row. A spacing of six times
the building height is necessary to ensure adequate air movement for second row. Thus the ‘five
times height’ rule for spacing is not quite satisfactory.
In a similar setting, if the buildings are staggered in a checker-board pattern, the flow field is
much more uniform, stagnant air zones are almost eliminated.
Humidity control:
Dehumidification is only possible by mechanical means: without this, in warm-humid climates,
some relief can be provided by air movement. In hot-dry climates humidification of the air may
be necessary, which can be associated with evaporative cooling. In these climates the building is
normally closed to preserve the cooler air retained within the structure of high thermal capacity,
also to exclude sand and dust carried by winds. However, some form of air supply to the building
interior is necessary.
All these functions -
Controlled air supply
Filtering out sand and dust
Evaporative cooling
Humidification
are served by a device used in some parts of Egypt - the wind scoop. The figure illustrates an
example of this. The large intake opening captures air movement above the roofs in densely built
up areas. The water seeping through the porous pottery jars evaporates, some drips down onto
the charcoal placed on a grafting through which air is filtered. The cooled air assists the
downward movement- a reversed stack effect.
This device is very useful for ventilation (the above four functions), but it cannot be expected to
create an air movement strong enough for physiological cooling.
In some parts of India a curtain made of cascas grass is often hung in front of windows on the
windward side. This is wetted by throwing a bucket of water against it from time to time. The
grass is highly absorptive and retains the moisture for a long time. The wind passing through the
loose textured mat curtain is both cooled and humidified.
In recent years the cascas mat is often hung from a perforated water pipe, which keeps it moist
all the time.
Architects in Israel have used a porous honey combed brick grill, with a perforated water pipe at
the top, for a similar pupose. The water pipe may be supplied by an automatic flush-cistern, of
the type used for urinals.