C C1

100MM WIDE CONTINOUS


WARNING STRIP F.R.P. (FIBRE
PLATFORM FINISHED EDGE REINFORCED PLASTIC 8MM THK.) 11435
(BOQ. ITEM NO. 14.5.2)

C C1

11435
B PLATFORM

3465
SEC LVL.+19.830

10 10
CONCOURSE 1100 HIGH SS 4500
LVL.+13.650 19051 RAILING AS/DET.

EDGE LINE

3605
EXPANSION JOINT
3605

2095
A A ESCALATOR FROM CONCOURSE LVL.
SEC UP SEC

1100 HIGH MS
RAILING AS/DET.

500
11 11
750 750 750 1000
LW 250 250 LW
LW
ROOF PORTAL GUTTER AS/DET. ROOF PORTAL
B
SEC
PART PLAN CONCOURSE LEVEL
ESCALATOR (ES-02) PART PLAN PLATFORM LEVEL
ESCALATOR (ES-02)

ADJUSTING BOLTE
GAP FILLED WITH MASTIC
BOLLARD

ANGLE

FLOOR PLATE 180 200


FINISHED
FLOOR LEVEL

C C1
11

135
3
2
19051 1
3763 10704 4584 4000 1100 HIGH SS
ROOF PORTAL RAILING AS/DET.
150 THK. 1100 HIGH SS 2095
RAILING AS/DET.
FLOOR
PLATFORM FINISHED 1100 HIGH MS RAILING PLATFORM
1100

1100
LVL.+19.830 UPPER WORKING LVL.+19.830
POINT
GUTTER
11900

CABLE TUBE (Ø 50MM)


DETAIL
EXPANSION JOINT Y
AS PER VENDOR Marks:
1. Steel Plate of 16 mm
2. Rubber sheet of 20 mm
3. Steel Plate of 20 mm
6180

6180
LOWER WORKING
POINT
CONCOURSE CONCOURSE TRUSS
LVL.+13.650
LVL.+13.650

Notes :
1350

Y 1. ALL DIMENSIONS ARE IN MILLIMETERS & LEVELS ARE IN METERS UNLESS OTHERWISE STATED.
2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED.

315
412
3. ALL GRID DIMENSIONS ARE MARKED FROM CENTRE LINE.
6502
4. THIS DRAWING MUST BE READ IN CONJUCTION WITH ALL RELEVANT ARCHITECTURAL
STRUCTURL,PLUMBING, FIRE FIGHTING, ELECTRICAL & TRAFFICE MANAGEMENT DRAWINGS.
SECTION "BB" 5. LOCATION OF COLUMNS TO BE VERIFIED WITH CIVIL/STRUCTURE DRAWINGS BEFORE
SECTION -"AA" EXECUTION.
6. ACTUAL SIZE OF CUTOUT AND OPENING AS PER SEM & M/HAVC DRAWING.
7. MASONRY WORK ON THE EXTERNAL FACE OF THE STATION MAY VARY AS PER
ARCHITECTURAL FEATURES OF THE STATION. THE DETAIL DRAWINGS TO BE SUPPLIED
BY RVNL DURING CONSTRUCTION.
8. FRONT WALL AT ALL SHAFTS NOT TO BE CASTED UNTILL INSTALLATION HAS BEEN DONE.
9. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF RVNL BEFORE EXECUTIION.
10. POSITION OF STUB COLUMNS AS PER ESCALATOR MANUFACTURE'S DETAIL.
11. TENDER DRAWING INDICATE THE EXTENT OF WORK INVOLVED HOWEVER THE ACTUAL
WORK SHALL BE EXCUTED AS PER DETAILED DRAWINGS/SPECIFICATIONS FOR WHICH NO
DETAIL
B ADJUSTMENT FOR PRICE BE ADMISSIBLE & THE PAYMENT SHALL BE AS PER RESPECTIVE
ITEM IN PRICING DOCUMENT.
12. OPENING SIZE MAY VARY DUE TO SITE CONDITION.
13. LIFT SHAFT PIT AND EXCALATOR PIT SIZES ARE AS PER THE INFORMATION PROVIDED BY
GM/ELECT/III KOL-PIU.

THE QUALITY ASSURANCE CORRECTNESS & COMPLETENESS OF


PROOF CHECKING THE DESIGN AND DRAWING AS PER THE DDC CONTRACT IS THE
Rail Vikas Nigam Limited
CONSULTANT (A Government of India Enterprise) RESPONSIBILITY OF THE DDC.

ARCHITECTURE
Dr. B. Manna Dr. R. Ayothiraman Prof. K.G.Sharma Dr. D. R. Sahoo Dr.V.Matsagar Prof. K.G.Sharma R.S. Pandit N.K.Sarkar N. K. Singh H. K. Barjatya D. C. Pandey Amit Tandon Dr. H. R.Yadav Rajesh Prasad S.Dungrakoti

DISCIPLINE
GEO - TECHNICAL & FOUNDATION DESIGN GROUP CIVIL STRUCTURE DESIGN GROUP SE AGM AGM/ Metro GM/ SAT GM/ Arch ED/Elect CPM/Majerhat ED/Design ED/Metro ED/S&T

SYSTRA
DETAILED DESIGN CONSULTANCY SERVICES FOR EIGHT
MVA
ELEVATED METRO STATIONS BETWEEN JOKA(CH.000) TO
MOMINPUR(CH:8755.00) IN JOKA -BBD BAG CORRIDOR OF Scale = 1:75 Dated : 31-01-2019
MKD. ISSUED DATE DESCRIPTION DEALT CHECKED APPROVED KOLKATA METRO RAILWAY LINE
R.K.Gupta A. Chauhan I.Ghosh S.Chatterjee Kshitij Om Prakash N. Kumar S.Ray
Status W Revision A
Proj. mgr E&M Plumbing FA/FF Associate Design Chkd. Reviewed Issued.