Report of Activity - DTD 27.09.2022

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

ABS

Industrial
Verification (India) Pvt. Ltd.
Page 1 of 4
Report no.:
ABSIV/IPE/KILLP/SK/- Project no.: 4941035 Report date: 27.09.2022 Office: Mumbai
005

REPORT OF ACTIVITY
Project: IOCL Paradip Refinery Dates of all related activity: 27.09.2022
Client: Supplier:
Company name: M/s. Kanakbhuvan Industries LLP
Company name: Kanakbhuvan Industries LLP
Addres: Shop number 20, Tulsi building
Shop number 20, Tulsi building 178, 10th Khetwadi back road,
178, 10th Khetwadi back road, Mumbai: 400004.
Mumbai: 400004.
Contact(s): Mr. Vimal Jay
Mobile No. +91 9867346098 Contact:
Office :-
PO/shop/contract: KBI0024 Dt: 24.09.2022
PO/shop/contract or job no:
Subvendor - 1:NIL Subvendor - 2:NIL
Company name: Company name:
Address: Address:
Contact(s): Contact(s):
PO/shop/contract or job no: PO/shop/contract or job no:
Component description(s).: Raw Material Results: Meets requirements
Identification Subject to condition(s) noted
Does not meet requirements
Applicable Specifications / QAP No.: GAIL-STD-IN-DOC-QAP-001 Rev.0

This is to certify that the undersigned did at the request of M/s. Kanakbhuvan Industries LLP attend the Kanakbhuvan
Industries LLP (Office) On 27/09/2022 and subsequent date(s) in order to carry out the scope of services described
below.

1.0 Scope of activity :-


1.1 Raw Materials identified for Offred Qty. of plates as mentioned in Annexure-A
1.2 Visual, Dimension, UT & PMI inspection
1.3 Review MTC for plates
1.4 Review Instrument Calibration Certificates used for Inspection
2.0 Details and results of inspection and test: -

1. 100% Visual inspection were witnessed for surface defects like Pitting, Rusted, Undercut and any
other manufacturing defect etc. and inspected plates are free from any injurious surface defects
and found Satisfactory.
2. Dimensional inspection carried out as per relevant standard i.e. O/D, length etc. and all
dimensions are found within tolerance limits and found acceptable
3. Ultrasonic test is carried out as per UT Procedure for Round Bar and result found within the
Acceptable limits and tolerances.
4. Round Bar inspected PMI as per standards / specification and found within tolerance limit as per
standard requirement
This Report is granted subject to the condition that it is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer or operator of any warranty, express or implied and the liability of ABS Industrial Verification (India) Pvt .Ltd shall be limited to the acts or omissions of its employees, agents
or subcontractors. Under no circumstances whatsoever shall ABS Industrial Verification (India) Pvt. Ltd be liable for any injury or damage to any person or property occurring by
reason of negligent operation or any defect in materials, machinery, equipment or other items other than such defects ascertainable by normally accepted testing standards and only upon
those items actually inspected by ABS Industrial Verification (India) Pvt. Ltd and which are covered by this Report.

2nd & 10th Floor, Lakhani’s Centrium, Plot No. 27,Sector 15, CBD, Belapur (E), Navi MUMBAI- 400 614
Tel: 91-22-27578780/41734173 ; Fax: 91-22-41734174 ; Email: absivmum@bom5.vsnl.net.in

Form IS-2
Reporting, SIZ-102-99-P02 Attachment B – Rev. 1
ABS
Industrial
Verification (India) Pvt. Ltd.
Page 2 of 4
Report no.:
ABSIV/IPE/KILLP/SK/- Project no.: 4941035 Report date: 27.09.2022 Office: Mumbai
005

5. Inspected Bar have been double hard punched " “for identification purpose. For all offered Bar,
samples (01 Sample / Heat / Size) were hard stamped for Lab check testing from NABL Lab and
lab test reports for the same are awaited. (Photo Attached for reference)

6. Reviewed Instrument Calibration Certificates.


.

1.0 Identification of inspection item(s) verified

Annexure-A
Sr No. Item Description / Size P.O Qty Inspected Qty

1 50 mm Round Bar Length 4980 mm 01 01

Measuring and testing equipment’s calibration details

Equipment Type Equipment Identity n° Last Calibration Expiry Date Certificate


Date
Ultrasonic Thickness AJ0439-9130 08/02/2021 21/10/2022 MIMCO/UFD/AJ0439/20
Gauge 20-21
PMI Machine P529 30/11/2021 29/11/2022 ----

2.0 Conclusion & Recommended Actions

Above Inspection/Witnessed activities for offered qty of Samples as mentioned in witnessed report,
were carried out as per QAP & Standard Specification. Results found acceptable. Reviewed
documents found in order.

3.0 Attachments

3.1 MTC
3.2 Instrument Calibration Certificates.
3.3 PMI report & UT test report

Photos:

This Report is granted subject to the condition that it is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer or operator of any warranty, express or implied and the liability of ABS Industrial Verification (India) Pvt .Ltd shall be limited to the acts or omissions of its employees, agents
or subcontractors. Under no circumstances whatsoever shall ABS Industrial Verification (India) Pvt. Ltd be liable for any injury or damage to any person or property occurring by
reason of negligent operation or any defect in materials, machinery, equipment or other items other than such defects ascertainable by normally accepted testing standards and only upon
those items actually inspected by ABS Industrial Verification (India) Pvt. Ltd and which are covered by this Report.

2nd & 10th Floor, Lakhani’s Centrium, Plot No. 27,Sector 15, CBD, Belapur (E), Navi MUMBAI- 400 614
Tel: 91-22-27578780/41734173 ; Fax: 91-22-41734174 ; Email: absivmum@bom5.vsnl.net.in

Form IS-2
Reporting, SIZ-102-99-P02 Attachment B – Rev. 1
ABS
Industrial
Verification (India) Pvt. Ltd.
Page 3 of 4
Report no.:
ABSIV/IPE/KILLP/SK/- Project no.: 4941035 Report date: 27.09.2022 Office: Mumbai
005

Dimension Inspection Dimension Inspection UT inspection

Offred Material Dimension Inspection PMI test inspection

UT inspection
Hard stamp Sample Heart stamp

This Report is granted subject to the condition that it is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer or operator of any warranty, express or implied and the liability of ABS Industrial Verification (India) Pvt .Ltd shall be limited to the acts or omissions of its employees, agents
or subcontractors. Under no circumstances whatsoever shall ABS Industrial Verification (India) Pvt. Ltd be liable for any injury or damage to any person or property occurring by
reason of negligent operation or any defect in materials, machinery, equipment or other items other than such defects ascertainable by normally accepted testing standards and only upon
those items actually inspected by ABS Industrial Verification (India) Pvt. Ltd and which are covered by this Report.

2nd & 10th Floor, Lakhani’s Centrium, Plot No. 27,Sector 15, CBD, Belapur (E), Navi MUMBAI- 400 614
Tel: 91-22-27578780/41734173 ; Fax: 91-22-41734174 ; Email: absivmum@bom5.vsnl.net.in

Form IS-2
Reporting, SIZ-102-99-P02 Attachment B – Rev. 1
ABS
Industrial
Verification (India) Pvt. Ltd.
Page 4 of 4
Report no.:
ABSIV/IPE/KILLP/SK/- Project no.: 4941035 Report date: 27.09.2022 Office: Mumbai
005

27/09/2022

Surveyor: Salman Khan


ABS Industrial Verification (India) Pvt. Ltd.

This Report is granted subject to the condition that it is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer or operator of any warranty, express or implied and the liability of ABS Industrial Verification (India) Pvt .Ltd shall be limited to the acts or omissions of its employees, agents
or subcontractors. Under no circumstances whatsoever shall ABS Industrial Verification (India) Pvt. Ltd be liable for any injury or damage to any person or property occurring by
reason of negligent operation or any defect in materials, machinery, equipment or other items other than such defects ascertainable by normally accepted testing standards and only upon
those items actually inspected by ABS Industrial Verification (India) Pvt. Ltd and which are covered by this Report.

2nd & 10th Floor, Lakhani’s Centrium, Plot No. 27,Sector 15, CBD, Belapur (E), Navi MUMBAI- 400 614
Tel: 91-22-27578780/41734173 ; Fax: 91-22-41734174 ; Email: absivmum@bom5.vsnl.net.in

Form IS-2
Reporting, SIZ-102-99-P02 Attachment B – Rev. 1

You might also like